| 1 | [20.76.17]Design, Supply and erection of transformer of standard make Required 25 KVA 11/0.433 KVA rating outdoor type 11 KVA V.C.B, panel, G.O. switch, H. Pole , H.T metering panel, APFC panel, battery charges, 11 KVA substation, entire cable network from G.O. switch to H.T metering equipment and from H.T metering to Transformer. From transformer to main to L.T, panel earthling, safety equipment, fenced enclosure for transformer, and any other contingent thereto complete in all respect as per PWD B&R / DHBVN approved make and directions of Engineer-in-charge as per respective capacity. 17. 1000 KVA ON LOAD TAP CHANGER [Through Rate] |
| 2 | [24.1.10]EARTHING AND LIGHTENING ARRESTOR 10. Providing and fixing 25 mm x 5mm copper strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 3 | [24.1.3]EARTHING AND LIGHTENING ARRESTOR 3. Earthing with G.I. earth plate 600 mmx 600 mm x 6 mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) complete as required. [Through Rate] |
| 4 | [24.1.4]EARTHING AND LIGHTENING ARRESTOR 4. Earthing with tinned copper earth plate 600mmx600mmx3mm thick including accessories and providing masonry enclosures with cover plate having locking arrangement and watering pipe etc. (but without charcoal or coke and salt) etc. complete as required. [Through Rate] |
| 5 | [24.1.5]EARTHING AND LIGHTENING ARRESTOR 5. Extra for charcoal or coke and salt for G.I. plate or copper plate earth electrode. [Through Rate] |
| 6 | [24.1.7]EARTHING AND LIGHTENING ARRESTOR 7. Supplying and laying 25mm x 3 mm G.I. strip in 40 mm dia,GI pipe as/from earth electrode including soldering etc. as required. [Through Rate] |
| 7 | [24.1.8]EARTHING AND LIGHTENING ARRESTOR 8. Providing and fixing 25 mm x 3mm G.I. strip on surface or in recess for connections etc. as required with all labour and material. [Through Rate] |
| 8 | [24.1.9]EARTHING AND LIGHTENING ARRESTOR 9. Providing and fixing 25 mm x5 mm copper strip in 40 mm dia G.I. pipe from earth electrode as required. [Through Rate] |
| 9 | [24.14.94]LT CABLES (Aluminium Conductor, Armoured and Unarmoured) PROVIDING& ERECTION/ LAYING OF PVC/ XLPE INSULATED UNDERGROUND ALUMINIUM CONDUCTOR UNDERGROUND CABLE ONSURFACE/ EXISTING CABLE TRAY COMPLETE IN ALL RESPECT WITH NECESSARY CONNECTION UPTO THE ENTIRE SATISFACTION OF ENGINEER IN CHARGE OF THE WORK 94. 300 Sq mm 3.5 core (Arm.) [Through Rate] |
| 10 | [24.16.4]HT CABLES (Aluminium Conductor, Armoured and Unarmoured) Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 4. Providing and erection/ laying of XLPE (E) 11 KV HT Aluminium Conductor Armoured Cable ISI Mark Laid in Existing Pipe/Trenches/Surface with all labour and material required to complete the job in all respect upto the entire satisfaction of the Engineer-In-Charge of the Works 95 Sq mm 3 core [Through Rate] |
| 11 | [24.2.7.7]LT CABLE 7.7. Supply and erection of suitable compression type brass cable glands for underground Cable :- 300 sqmm to 400 sqmm Cable 3 to 3½ Core [Through Rate] |
| 12 | [24.2.8.11]LT CABLE 8.11. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work. 150 sqmm [Through Rate] |
| 13 | [24.2.8.14]LT CABLE 8.14. Supply and erection of aluminium lugs heavy duty including crimping etc. up to the entire satisfaction of the Engineer-in-charge of the work.300 sqmm [Through Rate] |
| 14 | [24.3.4.1]HT CABLE 4.1. Supplying and making outdoor cable end termination with heat shrinkable jointing kit complete with all accessories including lugs suitable for following size of 3 core, XLPE aluminium conductor cable of 11 KV grade as required :70 to 120 sqmm [Through Rate] |
| 15 | [24.5.2.7]MISCELLANEOUS ITEMS 2.7. S/E mark double walled corrugated (DWC) HDPE, pipe 10 Kg/Cm2 ,laid 0.75 Metre below ground level including digging and refilling of earth including cost of suitable size socket/coupler for HDPE pipe including the cost of labour and material required to complete the job in all respect up to the entire satisfaction of Engineer in charge of the work. DWC/HDPE pipe 180/150 mm outer dia/ inner dia [Through Rate] |
| 16 | (N.S-2) installation, testing and commissioning of existing 500kva D/TF with allied materials and all Labour complete the job in all respect up to the entire satisfaction of the Engineer-in-charge of the work . As per HSR PH-117 Crane charges and Shifting, charge |
| 17 | (NS-1) Supply, installation, testing and commissioning of ACB 1600 amp. 4 pole 50 KA EDO with TS6E Trip unit having LCD Display for current and voltage metering and last 10 trip history microprocessor based with L.S.I.G. protection electrical draw out type complete with under voltage trip and shunt-trip, pre trip alarm and individual fault indicating LED:s Conforming to IS/IES 60947-2 and Make:-LandT/ /Schneider/Siemens in existing panel. ACB and ICS =ICU =ICW 100% for 1 Second. Suitable for operation on 400/440 volts 3 phase, 4 wire 50Hz AC supply with 4 Nos or 6 Nos.. (NC plus NO) auxiliary contacts and comprising of Dismantling of ACB800 Amp. 4P 50 KA existing Panel. Modification of existing LT panel (CT change and suitable size new CT installed) and Upgradation of copper bus bar as suitable with 1600amp. Connected with old bus bar 4 mtr Please Enable Macros to View BoQ information |