| 1 | Demolition of Cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level), complete all as specified and as directed. |
| 2 | Dismantling of stone slabs and tiles of any description or thickness in floors,aprons etc., complete all as specified and as directed. |
| 3 | Dismantling of stone slabs and tiles laid dry or laid dry and pointed of any description or thickness in floors,aprons etc., complete all as specified and as directed. |
| 4 | M & L for Walling of squared rubble,regular coursed, well bonded,bedded and solidly hearted masonary built in CM 1:6 including hammer dressing and Demolition of brickwork or stone/ boulder masonry all as specified and directed. |
| 5 | All as per Item No 4.00 here-in-above, but except material , complete all as specified and directed. |
| 6 | M&L for raised pointing to rubble or polygonal rubble, uncoursed or brought up to coarse with CM 1:3 |
| 7 | Material and labour for Pre-cast cement concrete block masonry with solid blocks, exc. 10 cm in width Type C1 1:3:6 (20 mm graded aggregate ) and setting in mortar CM 1:6, complete. Including Demolition of brickwork or stone/ boulder masonry |
| 8 | M&L for concrete 1:4:8 type D-2 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete including Demolition of Cement Concrete (unreinforced) of any description and in any position all as specified and directed. |
| 9 | Material and Labour for PCC (1:2:4) type B1 using 20 mm graded stone aggregate as in coping, mud stops, benching, water tank platform etc.on roof, chajja weathering, slightly rounded or chamfered angles and throating etc. including necessary form work and Demolition of Cement Concrete (unreinforced) of any description complete as directed. |
| 10 | M & L for Rendering 15mm thick cement mortar in 1:4 on fair faces of brick work or concrete surfaces even and smoothe without using extra cement.including taking down of old existing plaster of any description |
| 11 | M & L for Rendering 15mm thick cement mortar in 1:4 on fair faces of brick work or concrete surfaces even and smoothe without using extra cement. |
| 12 | M&L for preparation of new surface/undecorated surfaces of walls and applying two coats of Cement Base Paint of approved tint over a coat of priming on plastered and other surfaces with alkali resistant priming paint complete all as specified |
| 13 | S&F for Steel work in tubular trusses,post,purlin,rafter including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 grade St.-240, including dismantling of old steel structure of ant nature |
| 14 | S&F Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachment confirming to Fe 410-W (Gde E-250) quality A,complete all as specified and directed including dismantling of old steel structure of ant nature |
| 15 | M & L for framed work such as grill, gratings, etc with ends of bars shoulderedand /or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work corn-conforming to Fe.290. Gde -E-165, complete all as specified and directed. including dismantling of old steel structure of ant nature |
| 16 | M & L for Providing precast cement concrete type B1 1:2:4 (20mm graded aggregate) set in CM 1:4 in cover slabs (for man holes etc.) and similar articles with plain faces all as specified and as directed.including diemolition of old concrete of any description and thickness |
| 17 | M & L for Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specified. |
| 18 | M&L for providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed. |
| 19 | M&L for 75 mm thick cement concrete 1:4:8, type D-2 (40mm graded aggregate) as in floors,hardstanding complete all specified and directed. |
| 20 | Providing and laying 60mm thick factory made chamfered edge cement concrete paverblock of M-35 grade with approved colour, design & pattern as in footparth, parks,lawns, drive ways or light traffic parking etc., of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern as per IS -15658 over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand andcutting of paver blocks as per required size and pattern, finishing and sweeping extrasand; |
| 21 | Fixing only for precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness M-35 grade with grey cement and pigment. |
| 22 | M&Lfor Rubber Moulded glossy finish precast chequered cement concrete tiles 30cmx30cmx25mm thick,including 20 mm thick screed in cm(1:4),set,jointed in neat cement slurry in floors with grey pigment cement and pigments. |
| 23 | M&L for 300x300x10mm/ 400x400x10 mm thick non skid parking floor glosy finish paver tiles with grey cement and pigment over and including 20 mm thick screed in cm(1:4), set joinet and pointed in neat cement slurry in floors concrete all as specified and directed. |
| 24 | M&L Preparing new steel surfaces of any description, over 10cm in width/girth, applying two coats of synthethic enamel paint over one coat of red oxide primer. |
| 25 | S&F Pre-laminated galvalume aluminium zinc coating GI based corrugated steel sheet 0.5mm thick of an colour having tensile strength of 550 Mpa as in roof covering in any curvature, fixed with self tapping screws as specified.including dismantling of old existing sheet of any thickness and nature |
| 26 | S& F Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley, gutters etc. complete all as specified and directed.including dismantling of old existing sheet of any thickness and nature |
| 27 | S&F of 2mm Fibre glass reinforced translucent corrugated sheeting with two corrugations side lap fixed with coach screw and washer in roof, wall etc.including dismantling of old existing sheet of any thickness and nature |
| 28 | M & L for Jaisalmer stone for wall cladding (of any type) 35-55 mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of stone , exc .0.06 sqm but not exc 0.11 sqm ,including cutting and polishing types in wall including 20 mm thick CM 1:4 for laying Jaisalmer stone and including dismantling of old existing stones complete all as specified and direction by the Engineer-in-Charge. |
| 29 | Material & Labour for 35mm thick precast cement concrete louvres and jallies type C-0 (1:3:6) using 12.5mm graded stone aggregate (measured solid), in cluding all mouldings and frame set in cement mortar 1:4.and dismantling of old existing louvers and jallies of any thickness and size. |
| 30 | M&L for Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips |
| 31 | M&L for Mild steel TMT bars but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders |
| 32 | M&L for Formwork for flat finished surfaces to sides of concrete foundations, footings, bases of columns, raft and raft beams,sides and soffits (if any) of foundation and plinth beams;and similar work; vertical or to batter all as specified and directed. |
| 33 | M&L for M-25 Cement concrete Foundations, includingrafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, under-reamed piles and mass concrete all as specified and directed.including diemolition of old concrete of any description and thickness |
| 34 | S& F in repair for stainless steel letters (any from A to Z ) 300 to 600 mm height, 50-125 mm width and 25 to 40 mm depth made of 0.79 mm thick (22 Gauge) stainless steel 304 grade with seemless welding rubbed polished (Golden/silver/Rose gold ) and edges made smooth with necessary fixing devices like SS screws or as per manufacturs instruction to fixed on ACP sheet, wall or stone complete all as specified and directed by Engr-in-charge. |
| 35 | Supply & Fixed in repair aluminium composite panel not less than 3.0 mm thick and including covered both side by encapsulated lens type retro reflective sheet (grade 3 M type II diamond grade of make 3M/dark eye/ SNI) of any base,with and all as directed by Engr-In-charge. |
| 36 | M&L for preparation of existing treated surfaces of external walls/RCC surfaces/soffits of chajjas/roof projection/cantilivers/balcony etc including cornices and applying two coat of cement base paint @ 5sq.m/kg/1 coat over a one coat of of external primer by using following brands of cement base paint complete all as specified & as directed by engr-in-charge. |
| 37 | M&L for preparing existing treated surfaces of external walls/RCC surfaces/soffits of chajjas/roof projection/cantilivers/balcony etc including cornices and applying one coat of cement base paint @ 5sq.m/kg/1 coat by using following brands of cement base paint complete including necessary scaffolding all as specified & as directed by engr-in-charge. Please Enable Macros to View BoQ information |