| 1 | Dismantling floor, hearth or wall tiling including cement mortar bedding(but not backing) and disposal of debris complete all as specified and as directed. |
| 2 | M&L for providing screed bed or bedding layer, 15 mm thick, in cement mortar 1:6 for laying floor finishes complete all as specified and as directed. |
| 3 | M&L, rendering, 10 mm thick, in cement mortar 1:4, on wall surafaces, as backing coat to tiles complete all as specified and as directed. |
| 4 | M&L, Non skid ceramic coloured plain tiles,300 x 300 x 7mm thick, conforming to Group B-IIA of IS-13712, first quality, laid in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 5 | M&L, Glazed ceramic tiles, 300 x 450 x 7mm thick, glossy finish, conforming to Group B-III of IS-13712, first quality, of approved colour, laid on vertical surfaces such as skirting or dado etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and as directed. |
| 6 | M&L for, Viritified Ceramic tiles, 10 mm thick (square/ rectangular) polished, light shade, area of each tile not exceeding 0.36 Sq.m, laid in floors with neat cement slurry including pointing in white cement with pigment to match the shade of tiles, complete all as specified and as directed. |
| 7 | M&L for, Viritified Ceramic tiles, 10 mm thick (square/ rectangular) polished, light shade, area of each tile not exceeding 0.36 Sq.m, laid on vertical surfaces such as skirting, dados and risers to steps etc laid over and jointed in neat cement paste of honey like consistancy and pointed in white or coloured cement to match the shade of tiles, complete all as specified and as directed. |
| 8 | Taking down cement plaster on brick walls & concrete surfaces & the like including raking out joints, hacking for key, scrubbing down with water etc., any description, including removal of rubbish outside MoD land ,complete all as specified and as directed. |
| 9 | M&L, rendering 12 mm thick cement plaster in cement mortar (1:6) on fair faces of brick works or concrete surfaces , finished even and smooth without using extra cement , complete all as specified and as directed. |
| 10 | M&L, rendering 5 mm thick on RCC ceiling surfaces in cement mortar 1:3 and finished even and smooth without using extra cement , complete all as specified and as directed. |
| 11 | M&L, rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4, finished even and smooth without using extra cement, complete all as specified and as directed. |
| 12 | M&L for preparation of new plastered wall surfaces and applying two coats of cement base paint, complete all as specified and as directed. |
| 13 | M&L for preparation of new surfaces of ceiling,chajja etc, including brooming down or steel wire brushing; scrapping down smoke soot, moulds, moss and efflorescent salts and trading oil and greasy spots etc. and applying three coats of white wash, complete all as specified and as directed. |
| 14 | M&L for preparation of new plastered or un plastered wall surfaces of any description and applying two coats of oil bound distemper over a coat of Chalk whitening complete all as specified and as directed. |
| 15 | S&F, in repair, 600 X 450 mm beveled edge mirror or selected quality glass mounted on 6 mm thick AC building board or commertial plywood with aluminium frame around and fixed to wooden plugs with chromium plated screws and cup washers, complete all as specified and as directed. |
| 16 | Supply & fix in repairs , stainless steel Plate Rack of best quality, made out of 0.80 mm thick stainless steel sheet , of size 90 cm x 60 cm x 25 cm with all internal fittings of appoved make complete all as specified and as directed. |
| 17 | S&F in repair 20 mm bore ,CPVC medium grade , with all fittings (like Elbow , Tee, Socket, Gi pipe connecter, nipples, tank adaptor etc) and fixed complete to walls and ceilings or laid in floors or concealed, complete all as specified and as directed. |
| 18 | S&F, Stop valve/ Angle valve 15 mm dia, Chromium plated brass, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair , complete all as specified and as directed. |
| 19 | S&F, Stop valve/ Angle valve 15 mm dia, PTMT, screwed down high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions and fixed in repair , complete all as specified and as directed. |
| 20 | S&F, Pillar taps, 15 mm bore Chromium plated brass, fancy type, with capstan heads, screwed down high pressure, with or without lettered Hot or Cold with long screwed shanks and fly nuts, screwed for iron pipe fixed as in repair, complete all as specified and as directed. |
| 21 | S&F, Bib taps, Chromium plated brass, 15 mm bore dia, screwed for iron pipe and fixed as in repair, complete all as specified and directed by Engineer-in-Charge. |
| 22 | S&F, Bib tap standard of PTMT ,15mm bore dia of any colour high pressure screwed for iron pipe and fixed as in repair (minimum weight 90gms) complete all as specified and as directed. |
| 23 | S&F, Chromium plated brass shower rose 125 mm bore of rim with swivel joint fixed as in repairs , complete all as specified and as directed. |
| 24 | S&F, Wash basins, vitreous china, white, flat back of size 550x400 mm including brackets and cutting for and pinning in ends of brackets or erecting stand 32 mm dia waste fittings, brass, chromium plated with long screwed shanks and fly nuts and including new brackets fixed as in repair , complete all as specified and as directed. |
| 25 | S&F Vitreous china squatting pan Orissa pattern size 580x440 mm white with integral foot rest (exclusive flusing cistern& flush pipe) including cast iron 'P' or 'S' trap of 100 mm bore pipe fixed in PCC 1:2:4 type B-2 and necessary lime concrete, fixed as in repairs, including making good the surface to match with existing floor finish fixed as in repair complete all as specified and as directed. |
| 26 | S&F in repairs vitreous china water closet Padestal pattern (white) excluding fixing bolts, flushing cistern and flush pipe and including EWC Sheet cover complete all as specified and as directed. |
| 27 | S&F, PVC valveless , syphonic action type flushing cisterns 10 ltrs capacity , low level , white, with inlet ball valves , float and handle including brackets and pvc flush pipe 32 mm dia for low level fixed in repair , complete all as specified and as directed. |
| 28 | S&F, PVC connection of PTMT ,non corrosive with nuts and washers on both ends, 450 mm long suitable for 15 mm bore fixed in repair , complete all as specified and as directed. |
| 29 | S&F in repair ,15 mm bore, Brass CP mixer for wall for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and as directed. |
| 30 | S&F in repair ,Vitreous china bowl urinal flat back, size 465X355X265 mm white (minimum), with grating and union for discharge pipe(excluding flushing cistern,flush pipe),but including waste pipe, complete all as specified and directed. |
| 31 | S&F in repair, Sheet glass shelf assembly consisting of 5.5 mm thick sheet glass shelf 12 cm wide with chromium plated bracket guard and railing 60 cm long, complete all as specified and as directed. |
| 32 | S&F in repairs CP Health Faucet with 1 mtr metalic Expandable tube & hook complete all as specified and as directed. |
| 33 | Dismantling existing water storage tanks exc 250 litres but n.exc 500 litres capacity by disconnecting existing water connection and removal from site , complete all as specified and as directed. |
| 34 | S&F, Rotational moulded PVC, double layered, water storage tanks tripple layered of capacity 500 litre (cylindrical vertical with closed top), ISI Marked, hoisted and fixed in position, with & including all fittings such as GI tank nipple etc. but excluding ball valve , complete all as specified and as directed. |
| 35 | S&F PVC waste pipe, 32mm bore, 750mm long for basin, fixed in repair, complete all as specified and as directed. |
| 36 | Demolition of tiles/ Interlocking tiles laid bedded and pointed in any mortar of any description or thickness in floors, aprons, etc complete all as specified and as directed. |
| 37 | M&L Chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick, set jointed and pointed in neat cement slurry with grey cement and pigment over and including 15 mm thick screed bed in CM 1:6 complete all as specified and as directed. |
| 38 | M&L for PCC 1:2:4 type B1 using 20 mm graded stone aggregate as in side of path / benching / coved fillets etc rounded or chamfered on edges complete all as specified and as directed. |
| 39 | M & L for Machine pressed precast concrete interlocking paver block any shape and size with grey cement and coloured pigment confirming to IS 15658-2006 of 80 mm thickness, M-40 Grade over 25mm thick coarse sand complete all as specified and as directed. |
| 40 | M&L for Sand filling under floors or in foundation including watering and consolidating complete all as specified and as directed. |
| 41 | Cleaning of pipe drains by jet mechine 100mm internal dia drain pipe upto 1.50 m in depth and removal of sludge/silt/liquid/mud and sand (in foul position) etc out side the MOD land including testing of drains by filling the pipes with water complete all as specified and as directed. |
| 42 | All as per item No 41 above but exceeding 1m and not exceeding 2m in depth . |
| 43 | Cleaning of manhole by mechanical scrappers exceeding 0.5 m and not exceeding 2 m depth and removal of sludge silt/liquid/mud/sand/water etc in foul position to out side the MOD land complete all as specified and directed.(manholes can be repeated) |
| 44 | Dewatering/desilting of septic tanks,soak wells etc cleaning of all sludge,silt residue of both organic and inorganice nature by mechnical scrappers etc and disposal of the same out side the defence land incl dumping the material to any depth complete all as specified and directed. (septic tank can be repeated) |
| 45 | Supply only integral water proofing compound conforming to IS-2645-1975 complete all as specified and as directed. |
| 46 | Demolition of brick work built in cement mortar including all quoins, arches , pillars etc but excluding precast concrete articles, complete all as specified and as directed. |
| 47 | M & L, Brick work with sub class 'B' bricks , straight or curved on plan not exc 6 m mean radius built in cement mortar 1:6, complete all as specified and as directed. |
| 48 | Demolition of cement concrete unreinforced in groundfloors and pavings not exc 15cm thickness below or above ground level etc complete all as specified and as directed. |
| 49 | M&L 100 mm thick PCC 1:4:8 type D-2 (using 40mm grade stone aggregate) as in Sub floors,Sub bases ,flooring etc complete all as specified and as directed. |
| 50 | M&L cement concrete 75 mm thick type C-2 1:3:6 ( 40 mm graded stone agg ) as in plinth protection etc complete all as specified and as directed. |
| 51 | M&L, Plain cement concrete 1:2:4 type B-1(20mm graded stone aggregate) 55 mm thick as flooring finished even & smooth without using extra cement , complete all as specified and as directed. |
| 52 | Demolition & breaking up drain pipes (salt glazed stone ware, AC or reinforced concrete) set in cement mortar, internal dia of pipe 100 mm complete all as specified and as directed. |
| 53 | All as per item No 52 above but bore of pipe 150 mm. |
| 54 | S&F 110 mm PVC (SWR ) , pipes single socketd , in any length with rubber ring joints , laid in trenches or in floor complete all as specified and as directed. |
| 55 | S & F RCC Class NP 3, 150 mm bore pipes laid and jointed complete with collars complete all as specified and as directed. |
| 56 | M&L concrete bed to 100 mm bore drain pipes in cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregates including packing under and haunching against the sides of pipes after they are laid and tested complete all as specified and directed by Engineer-in-Charge |
| 57 | All as per item No 56 above but bore of pipe 150 mm. |
| 58 | Excavation in trenches not exceeding 1.50m wide and not exceeding 1.50 m in depth for manholes & sewage lines and getting out in soft/loose soil complete all as specified and directed by Engineer-in-Charge |
| 59 | Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm complete all as specified and as directed. |
| 60 | Removing excavated materials to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed. |
| 61 | M&L PCC 1:2:4 type B2 as in surface channels and drains & benching of manholes and finishing even and smooth with out using extra cement complete all as specified and as directed. |
| 62 | M&L for providing cement concrete 1:2:4, type B1, using 20 mm graded stone aggregates as in coping complete all as specified and as directed. |
| 63 | Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required, Internal dia of pipe 150mm complete all as specified and as directed. |
| 64 | Cutting into existing manholes for connecting new drains, making good to pipes and rendering, cutting out existing benching for & forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required, Internal dia of pipe 100mm complete all as specified and as directed. |
| 65 | S& F in repair 15 mm bore Ball PTMT valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repair and complete all as specified and as directed. |
| 66 | S&F in repair 20 mm bore Ball PTMT valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed in repair and complete all as specified and as directed. |
| 67 | Demolition of reinforced cement Concrete of any description and in any position not otherwise specifically provided as in cover slab for manholes etc complete all as specified and as directed. |
| 68 | M&L for pre-cast reinforcement cement concrete (1:2:4) Type B-1, using 20 mm graded stone aggregate as in cover slab for manholes etc.and set in cm 1:6, inclding form work complete all as specified and as directed. |
| 69 | M&L for Mild steel TMT bars 6 to 8 mm dia., and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with dips icl, anchoring and welding at places as directed quilety conforming to IS complete all as specified and as directed. |
| 70 | Taking up or down 15 mm bore steel tubing with connections or fittings from wall, ceiling and floor etc., including cutting/chasing in wall/floor and removal from site, complete all as specified and as directed. Please Enable Macros to View BoQ information |