| 1 | Excavation in trenches not exceeding 1.5m wide and n. exc. 1.5m in depth for foundation etc or for shafts, wells, cesspits, manholes pier holes etc not exceeding 10 sqm on plan and n. exc. 1.5m in depth in soft/loose of soil etc complete all as specified and directed |
| 2 | Excavating over areas, n exc 1.5 m deep and getting out 1 in any type of soil etc complete all as specified and directed |
| 3 | Excavating over areas, exc 1.5 m but n.exc 3.0 mtr deep and getting out 1 in any type of soil etc complete all as specified and directed |
| 4 | Returning, filing in, excavated soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified and directed. |
| 5 | Removal of excavated materials to a distance n. exc. 50 m and depositing where directed at a level n. exc. 1.5 m above the starting point complete all as specified and directed |
| 6 | Demolition and breaking up drain pipe (salt glazed stone ware, AC or reinforced concrete) set in cement mortor for 150 mm internal dia of pipe complete all as specified and directed. |
| 7 | Demolition and breaking up drain pipe (salt glazed stone ware, AC or reinforced concrete) set in cement mortor for 200 mm internal dia of pipe complete all as specified and directed. |
| 8 | M&L for 100mm thick PCC 1:3:6 type C2 using 40mm graded stone aggregate as in sub-bases, sub-floors,flors and pavings complete all as specified and directed. |
| 9 | M&L for PCC 1:4:8 type D2 using 40mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed. |
| 10 | M&L for Broken bricks/brick bats Hardcore of guage exc 63mm but n exc. 100 mm, deposited, spread and levelled in layers complete all as specified and directed. |
| 11 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 110 mm bore of pipe etc complete all as specified and directed. |
| 12 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls of 110 mm bore of pipe etc complete all as specified and directed. |
| 13 | M&L for PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors of 75 mm bore of pipe etc complete all as specified and directed |
| 14 | S&F PVC (SWR) bends ISI marked any radius of 110 mm bore with access door complete all as specified and directed. |
| 15 | S&F PVC (SWR) bends ISI marked any radius of 75 mm bore with access door complete all as specified and directed. |
| 16 | S&F PVC (SWR) junction single, (single T) with acess door equal or un equal of 110 mm bore of pipe complete all as specified and directed |
| 17 | S&F PVC (SWR) vent cowl of 110 mm bore of pipe complete all as specified and directed |
| 18 | M&L for DWC HDPE pipes Class SN-8 laid in trenches of 150 mm internal diameter of pipe and jointed as specified complete all as specified and directed.Make Finolex or equivalent |
| 19 | M&L for DWC HDPE pipes Class SN-8 laid in trenches of 200 mm internal diameter of pipe and jointed as specified complete all as specified and directed. |
| 20 | Cutting into existing manholes for connecting new drains, making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-l smooth finished, and reforming benching as required of dia of pipe 100 mm to 200 mm complete all as specified and directed |
| 21 | Demolition of brick work or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc complete all as specified and directed. |
| 22 | M&L Brick work using old size bricks with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in cement mortar 1:6 complete as in manhole/septic tank and other similar works. |
| 23 | M&L Brick work using old size with sub class ‘B’ bricks in one brick thick honey comb walling, built in cement mortar 1:4 complete all as specified and directed. |
| 24 | Taking down cement plaster any description on brick or stone walls etc including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed. |
| 25 | M&L for rendering on fair faces of brick work or concrete surface of wall 15mm thick in CM 1:6 and to be finished even and smooth with using extra cement complete all as specified and directed |
| 26 | M&L for PCC 1:2:4, type B-1 using 20 mm graded stone aggregate as in coping, benching, bed block, lintel band, plinth courses, drains and channels etc and similar work including necessary form work complete all as specified and directed. |
| 27 | M&L Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred / stopped ends etc complete all as specified and directed. |
| 28 | M&L for Precast cement concrete 1:2:4 type B1 using 20 mm graded stone aggregate as in landings, cover slab (for manholes etc) and similar work including necessary form work and set in CM 1:4 complete all as specified and directed. Note :- Reinforcement shall be measured and paid separately. |
| 29 | M&L for Mild Steel TMT bar 10 mm dia and over cut to length bent to shape required incl cranking, bending spirally for hooping for columns hooking ends and binding with & including Mild Steel wire (annealed) not less than 0.9mm dia complete. |
| 30 | M&L for RCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in slab supported on wall, canopies and in shelves and similar work complete all as specified and directed. |
| 31 | Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200 mm thick (horizontal or sloping) for rough finished flat surface of concrete complete all as specified and directed |
| 32 | Formwork to edges of concrete flats and similar works exc. 5 cm & not exc. 10 cm wide with rough finished surfaces etc. |
| 33 | Taking down or Demolition and breaking up drain pipes 150 mm (Salt glazed ware, AC or Reinforced concrete) set in cement mortar including fittings complete. |
| 34 | S & F of Vitreous China wash down water closet pan (pedestal pattern), white (excluding flushing cistern and flush pipe) complete all as specified and directed |
| 35 | S&F in repair PVC flushing cistern syphonic action type, 10 liters capacity, low level white with inlet ball valve, float and handle including bracket including PVC flush pipe, 32mm dia as fixed in repairs complete all as specified and directed. |
| 36 | S & F of vitreous China ‘Orissa’ pattern, size 580 x 440 mm white including trap with integral foot rests Water closet (Squatt pattern) complete incl provision of lime concrete bedding as in repair. |
| 37 | M&L for Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises |
| 38 | S & F Glazed ceramic coloured tiles in vertical surfaces 450 x 300 x 7mm thick set and jointed in neat cement slurry and pointed in coloured cement to match incl 10 mm thick rendeing in CM 1:4 complete all as specified and directed |
| 39 | M&L for non skid colourerd ceramic tiles coloured 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exc 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in coloured cement to match over 15 mm thick screed bed in cement mortar 1:6 complete all as specified and directed |
| 40 | M & L for PVC (SWR) as in repair floor trap, plain with grating including jointing with solvent cement of 75 mm dia outlet. |
| 41 | M & L for PVC (SWR) as in repair multi floor trap with SS grating including jointing with solvent cement of 75 mm dia outlet. |
| 42 | M & L for PVC (SWR) as in repair gully trap 125/110 mm, setting and jointing with solvent cement |
| 43 | M & L for soft closing closing seat cover white, including chromium plated or aluminised hanging device complete. |
| 44 | S&F PVC connections 15mm size with PTMT nuts of length 450 mm all as specified and as directed. |
| 45 | Clearing & removal of blockage, of any type in WC, bathroom, kitchen incl floor/nahani traps, soil waste/vent pipes gully trap upto 1st manhole, in any situation by way of cleaning / desludging and removing foreign materials to a distance up to 50 metres to the entire satisfaction |
| 46 | Clearing & removal of all blockage in sewage line of any dia of sewer lines, manholes of any section and any depth, in any situation by way of cleaning / desludging foreign materials as well as blockage of sewage line in between successive manholes manunally/mechanically including desludging of manhole /sewage line where required and odered by Engineer-in-charge and keeping sewer line functional, upto final drop/outlet into septic tank /central sewage system terminating in other joining zone/ area or into sewage wells complete all as specified. Note for item No 15 & 16:-(a) Contractor shall detail his supervisor to office of AGE B/R II daily by 9.00 AM who will report to concerned JE B/R /Engineer-in-Charge to receive all complaints of entire area under this contract.(b) Contractor shall provide service providers (sweepers) as per the complaints list given alongwith all requisite tools, equipments, including safely measures for attending complaint and ensure completion report by 5.00 PM same day. (c) Please note that all the complaints relating to sewage line shall be attended within same day (within 12 hour). In case of blockage in sewage line could not be detected/completed same day and concerned JE / Engineer-in-Charge is satisfied to the efforts applied but the same shall be attended and all blockage must be cleared by 24 hours (next day by 5.00 PM) without fails. (d) In case any complaint pertaining to clearing of blockage in sewage line is not removed /cleared within 24 hours (next day 5.00 PM). A penalty @ Rs. 50/- per complaint shall affected from contractor payments. |
| 47 | Mechanically pumping out sewage liquid / rainwater from septic tank/soak wells/manholes/drains of any size and depth and removal the same to distance n.exc 50 m outside of the building perimeter including using of any type of T&P required etc for dewatering of water complete all as directed. |
| 48 | Taking out and removal of sludge from septic tank/manholes of any size and depth and burying the sludge in pits of suitable depth and top of pit shall be covered with earth layer of 30 cm duly compacted out side the building perimeter upto a distance of 50 metres including excavation of pits, removal of surplus soil excluding dewatering of water complete all as specified and as directed. Note:- Dewatering of water or mud will be measured and paid separately, only sludge will be measured and paid under this item. |
| 49 | Cleaning of toilet/Urinals at office annexex of GE Gaya with chemicals (Harpic etc) and water complete all as specifed and directed |
| 50 | Supplying and laying of CPVC pipes 25 mm outer dia SDR 11 including fittings on walls/ceiling or laying in floors incl chase cutting complete all as specified and directed |
| 51 | S & F Supplying and laying of CPVC pipes 20 mm outer dia SDR 11 & Plain CPVC SDR 11 fittings on walls/ ceiling or laying in floors complete all as specified and directed Supply and laying river bed fine sand in trenches/ ducts 15 cm under cable and 8 cm above the cable for cushioning / protection to cable including spreading, levelling and get thick 18cm after hand punning complete all as specified and directed at site. Please Enable Macros to View BoQ information |