| 1 | Periodical maintenance and inspection/checking of following size /capacity of DG sets and ensuring smooth functioning of DG sets and replacements of unsv parts of DG sets of following capacities : - Note:- Spare parts required shall be measured and paid separately . |
| 2 | 200 KVA DG SET |
| 3 | 160 KVA DG SET |
| 4 | 125 KVA DG SET |
| 5 | 75 KVA DG SET |
| 6 | 35/40 KVA DG SET |
| 7 | 30 KVA DG SET |
| 8 | Supply and fixing in Replacement bypass filter element with O ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for the following capacities of DG Sets :- |
| 9 | 200 KVA DG SET |
| 10 | 160 KVA DG SET |
| 11 | 125 KVA DG SET |
| 12 | 75 KVA DG SET |
| 13 | 35/40 KVA DG SET |
| 14 | 30 KVA DG SET |
| 15 | Supply and fixing in Replacement luberication oil filter element with 'O' ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for following capacities of DG Sets :- |
| 16 | 200 KVA DG SET |
| 17 | 160 KVA DG SET |
| 18 | 125 KVA DG SET |
| 19 | 75 KVA DG SET |
| 20 | 35/40 KVA DG SET |
| 21 | 30 KVA DG SET |
| 22 | Supply and fixing in Replacement Air filter element inner and outer as required filter element at site with 'O' ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for following capacities of DG Sets :- |
| 23 | 200 KVA DG SET |
| 24 | 160 KVA DG SET |
| 25 | 125 KVA DG SET |
| 26 | 75 KVA DG SET |
| 27 | 35/40 KVA DG SET |
| 28 | 30 KVA DG SET |
| 29 | Supply and fixing in Replacement fuel filter element with 'O' ring of Kirloskar /Crompton greeves/Mahindra DG Sets as required at site as per make and model for following capacities of DG Sets :- |
| 30 | 200 KVA DG SET |
| 31 | 160 KVA DG SET |
| 32 | 125 KVA DG SET |
| 33 | 75 KVA DG SET |
| 34 | 35/40 KVA DG SET |
| 35 | 30 KVA DG SET |
| 36 | Supply and fixing in Replacement of Fan belt of Kirloskar /Crompton greeves/Mahindra DG Sets as per given sample for10 KVA to 75 KVA DG Sets. |
| 37 | Supply and fixing in Replacement of Fan belt of Kirloskar /Crompton greeves/Mahindra DG Sets as per given sample for125 KVA to 200 KVA DG Sets. |
| 38 | Taking of FIP from the Engine and Calibration of FIP (Fuel Injection Pump) 30 to 160 KVA DG Set Make : Ashok Leyland /Kirloskar / Cummins/Crompton Greaves Jyoti at admissible pressure including minor spares etc testing and refitting all as specified and directed. |
| 39 | Taking of FIP from the Engine and Calibration of FIP (Fuel Injection Pump) 200 KVA DG Set Make : Ashok Leyland /Kirloskar / Cummins/Crompton Greaves Jyoti at admissible pressure including minor spares etc testing and refitting all as specified and directed. |
| 40 | Supply and fixing in Replacement distilled water to be filled in batteries ,complete all as specified and directed by Engineer-in-charge. |
| 41 | Supply and fixing in Replacement ignition switch with key in repair for DG sets of any capacities, complete all as specified and directed by Engineer-in-charge. |
| 42 | Material & Labour for replacement of battery cable of size 40 sqmm PVC insulated multi stranded copper conductor single core cable with necessary lugs, complete all as specified and directed by Engineer-in-charge. |
| 43 | Supply and filling in Replacement top up coolent for DG set radiator |
| 44 | Supply and fixing in Replacement Water temperature gauge for 200 KVA DG set complete all as specified and as directed. |
| 45 | Supply and fixing in Replacement Water temperature gauge for 160 KVA DG set complete all as specified and as directed. |
| 46 | Supply and fixing in Replacement Water temperature gauge for 125 KVA DG set complete all as specified and as directed. |
| 47 | Supply and fixing in Replacement oil pressure gauge assembly for 35/40 KVA DG set complete all as specified and as directed. |
| 48 | Supply and fixing in Replacement cable for Techno meter for 35/40 KVA DG set complete all as specified and as directed. |
| 49 | Supply and fixing in Replacement Techno meter assembly for 160/200 KVA DG set complete all as specified and as directed. |
| 50 | Supply and fixing in Replacement flexible braided hydraulic hose 5/8\\" dia x 600 mm length including suitable check nuts & washers, complete all as specified and directed by Engineer-in-charge. |
| 51 | Supply and fixing in Replacement RPM metre with cable (0-3000 RPM),, complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply and filling in Replacement lube oil 20 W - 40 for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling, complete all as specified and directed by Engineer-in-charge.Make : Castrol/Power Supreme |
| 53 | Supply and filling in Replacement lube oil SAE 15 W - 40 for Top up and filling up the oil in the sump after completely flushing the old oil out of the tank and cleaning of the tank for fresh filling, complete all as specified and directed by Engineer-in-charge.Make : Castrol/Power Supreme |
| 54 | Supply and fixing in Replacement battery terminal heavy duty as per sample made of brass with bolts and washers all as required at site,, complete all as specified and directed by Engineer-in-Charge. |
| 55 | Supply and fixing in Replacement complete 12 V 180 AMPH maintenance free battery and initial charging complete including inbuilt charger including required electrolyte /distilled water etc and fixing as required at site to the concerned DG Set, complete all as specified and directed by Engineer-in-charge. |
| 56 | Supply and fixing in Replacement of self starter assembly for DG set of 40 KVA 12 volts DC including, complete fixing and testing, complete all as specified and directed by Engineer-in-charge.Make:-Lucas-TVS |
| 57 | Supply and fixing in Replacement of self starter assembly for DG set of 160 KVA 12 volts DC including, complete fixing and testing, complete all as specified and directed by Engineer-in-charge.Make:-Lucas-TVS |
| 58 | Supply and fixing in Replacement of self starter assembly for DG set of 200 KVA , 24 volts DC including, complete fixing and testing, complete all as specified and directed by Engineer-in-charge.Make:-Lucas-TVS |
| 59 | Supply and fixing in Replacement PLC system for DG sets of 35/40 KVA capacities , complete all as specified as directed by Engineer-in-charge. |
| 60 | Supply and fixing in Replacement PLC system for DG sets of 160 KVA capacities , complete all as specified as directed by Engineer-in-charge. |
| 61 | Supply and fixing in Replacement PLC system for DG sets of 200 KVA capacities , complete all as specified as directed by Engineer-in-charge. |
| 62 | Taking out the radiator assembly from DG Set of capacity 40 KVA to 160 KVA for cleaning/servicing and cleaning the radiator externally/internally and reinstallation after carrying out the job work:- |
| 63 | Externel Cleaning :- Removel of light deposits by using low pressure hot stream jet with addition of detergent and incase stuuborn deposits experienced the radiator to be immersed in a heated Alkali degreasent solution for 30 minutes and then washing off with hot water hose complete all as specified and directed |
| 64 | Internel Cleaning:-Internel cleaning be done by prepration of solution of inhivited acid solvent with fresh water and circulation of acid solution in radiator for severel times descaling the acid solution by adding 700 gm of soda with 20 ltrs boiling water .Refining be done after pressure check complete all as specified and directed. |
| 65 | Supply and fixing in Replacement of turbo charger Suitable for 30 KVA to 160 KVA, complete all as specified as directed by Engineer-in-charge. Make:- Holest or equivalent as approved. |
| 66 | Supply and fixing in Replacement of turbo charger,Suitable for 200 KVA complete all as specified as directed by Engineer-in-charge.Make:- Holest or equivalent as approved. |
| 67 | Taking out the radiator assembly from DG Set of capacity 200 KVA for cleaning/servicing and cleaning the radiator externally/internally and reinstallation after carrying out the job work:- |
| 68 | (a) Externel Cleaning :- Removel of light deposits by using low pressure hot stream jet with addition of detergent and incase stuuborn deposits experienced the radiator to be immersed in a heated Alkali degreasent solution for 30 minutes and then washing off with hot water hose complete all as specified and directed |
| 69 | (b) Internel Cleaning:-Internel cleaning be done by prepration of solution of inhivited acid solvent with fresh water and circulation of acid solution in radiator for severel times descaling the acid solution by adding 700 gm of soda with 20 ltrs boiling water .Refining be done after pressure check complete all as specified and directed. |
| 70 | Inspection/checking of AMF panel of DG set of capacity 40 KVA to 125 KVA installed at various installations of any make and shape and rectify the defects, replacement of unserviceable part as required at site and cleaning of AMF panel as detecting during inspection or pointed out by users/department and carry out maintenance , complete all as specified as directed by Engineer-in-charge. Note:- Spare parts required shall be measured and paid separately . |
| 71 | Inspection/checking of AMF panel of DG set of capacity 160 KVA to 200 KVA installed at various installations of any make and shape and rectify the defects, replacement of unserviceable part as required at site and cleaning of AMF panel as detecting during inspection or pointed out by users/department and carry out maintenance , complete all as specified as directed by Engineer-in-charge. Note:- Spare parts required shall be measured and paid separately . |
| 72 | Supply and fixing in Replacement engine start relay 12 volt DC suitable for AMF panels Complete all as specified as directed by Engr-in-Charge Make:- Eagle Man/PIC |
| 73 | Supply and fixing in Replacement frequency meter 45 to 55 HZ AC 415 volt of size Sqmm suitable for AMF panels complete all as specified as directed by Engineer-in-Charge. Make:- AE/Premier. |
| 74 | Supply and fixing in Replacement selector switch for volt/ampere metre 415 volt four stage suitable for AMF panels Complete all as specified as directed by Engr-in-ChargeMake:- L&T/CONCORD/KAYCEE/C&S |
| 75 | Supply and fixing in Replacement cranking relay 12/24 volts DC 8/11 stage suitable for AMF panels complete all as specified as directed by Engineer-in-Charge.Make:- Eagle Man or equivalent as approved |
| 76 | Supply and fixing in Replacement indicator lamp assembly LED type with red/green/blue for phases R,Y,B suitable for AMF panels complete all as specified as directed by Engineer-in-Charge. |
| 77 | Supply and fixing of battery12 V, 150 AH complete all as specified and directed. Make :- Exide Xpress / Mico or equivalent. |
| 78 | Supply and fixing of battery12 V, 100 AH complete all as specified and directed. Make :- Exide Xpress / Mico or equivalent. |
| 79 | M/L for Repairs to out door LT panel including taking down for repair as follows :-( a ) Supply and fixing of MS sheet 16 SWG( 1.6 mm ) and fabrication of back side cover of LT panel including cutting to required size and shape fixing in position by bending, welding all as required for proper functioning of LT panel shutters including two coats of coats of synthetic enamel paint over a coat of red oxide.(b ) Supply and fixing of hinges , tee type stove enamelled black medium weight , cold rolled and mild steel 30 mm size and fixed door shutters ( c ) Supply and fixing of locking arrangement with MS sliding door bolts hasp and suitable for use with pad lock of size 200 mm( d ) Mild steel work conforming to Fe-410-0 or Fe-310-0 as in angle iron frame work , cut to size including bending and welding angles as necessary and re -fixing of MS sheet of panel including a shop coat of red oxide prime |
| 80 | Dismantling of self starter and remove of defected parts and replace suitable for DG set of 35 to 160 KVA and fixing the same including testing.(Defective spares part to be paid seprately) |
| 81 | Supply only Solenoid Switch |
| 82 | Supply only Armature |
| 83 | Supply only Field coil copper |
| 84 | Supply only Carbon Brush |
| 85 | S&F fuel pipe from filter to FIP with benzo bolt as per sample suitable for DG sets upto 110 KVA complete all as specified and directed. Make:- Kirloskar, Mico |
| 86 | S&F self Starter 12V as per sample suitable for DG set 12v operated. Make:- Kirloskar, Locus. |
| 87 | Routine maintenance of DG set of capacity 30 KVA to 200 KVA by carrying out the test check for belt tensioin,adjustment of valve clearance with clearance gap o 0.4 mm for both inlet and exhaust valve and adjustment of tapped with filer gauge,replacement of changing gear and Flywheel and oil,cleaning of injector/Nozzles and spray check,servicing of self starter by replacement of carbon bushes,Terminal wires including cleaning with vaccum cleaner to wipe out unwanted materials/dust from alternator and other minor repairs/servicing of Emgine complete all as specified and directed by Engineer-in-Charge. ( Make of engine Kirloskar/Greaves). |
| 88 | Supply and Fixing in Replacement Alternator AVR for following capacities of DG Sets :Make- National/Kirloskar /Crompton greeves |
| 89 | 30 KVA To 75 KVA DG SET |
| 90 | 100 KVA To 200 KVA DG SET |
| 91 | Supply and fixing in Repalcement of on line Fuel Solenoid Switch 12 V DC |
| 92 | Supply and fixing in Repalcement of on line Fuel Solenoid Switch 24 V DC |
| 93 | Supply and fixing in Repalcement of Off line Fuel Solenoid Switch 12 V DC |
| 94 | Supply and fixing in Repalcement of Off line Fuel Solenoid Switch 24 V DC |
| 95 | Supply and fixing Procom Controller 6 Module 12 Volt & 24 Volt DC Complete all as specified and directed by Engineer-in-Charge. Make:- Procom/GE/STANDARD |
| 96 | Supply and fixing in Repalcement of Relay Card 2 plush 3 suitable for 12 V DC Complete all as specified and directed by Engineer-in-Charge |
| 97 | Supply and fixing in Repalcement of Relay Card 2 plush 3 suitable for 24 V DC Complete all as specified and directed by Engineer-in-Charge |
| 98 | Supply and fixing Battery Charger in AMF Panel Capacity 12 v 10 Amps with SMPS base Complete all as specified and directed by Engineer-in-Charge |
| 99 | Supply and fixing Battery Charger in AMF Panel Capacity 24 v 10 Amps with SMPS base Complete all as specified and directed by Engineer-in-Charge |
| 100 | Supply and Fixing in replacement Control Cable 6 Core 2.5 Sqmm Complete all as specified and directed by Engineer-in-Charge |
| 101 | Supply and fixing in replacement 12\\" Fuel Pipe 8mm Bore pressure 8 Kg /Cm Squire |
| 102 | Supply and fixing in replacement 24\\" Fuel Pipe 8mm Bore pressure 8 Kg Cm Squire |
| 103 | Supply and fixing in replacement 36\\" Fuel Pipe 8mm Bore pressure 8 Kg Cm Squire |
| 104 | Supply and fixing in replacement 48\\" Fuel Pipe 8mm Bore pressure 8 Kg Cm Squire |
| 105 | Supply and fixing in replacement 72\\" Fuel Pipe 8mm Bore pressure 8 Kg Cm Squire |
| 106 | Checking of earthing resistence of 450 Nos Earthing and E-N voltage quarterly with caliberated earth tester meter and multimeter including recharging of earthing with chemical, maintaining the earth testing record, rectification of earthing related fault complete all as specified and directed by the Engineer-in-Charge. NOTE:- (a) Testing record and rectification of earthing shall be signed by user and JE (E/M) and verified by Engineer in charge. (b) Measurement of three month shall be treated as one Job. (c) Chemical required for recharging of earthing shall be measured and paid separately. |
| 107 | Supply only of potassium Nitrate (commercial name kalmi shora) in the earthing chambers for improvement of the existing earthing resistence complete all as specified and directed by the Engineer-in-Charge. |
| 108 | M&L in repairs for earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m deep below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth lead wire 4mm dia by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with PCC frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc. complete including taking out existing earthing all as specified and directed. Note: -(i) Item includes the cost of 7.5 metre GI pipe for protection of earth lead. (ii) Item includes the cost of 7.5 metre GI earth lead. |
| 109 | Material & labour in repairs for earthing complete with copper earth plate electrode 60cm x 60cm x 3.15 mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5m below normal ground level, connected to and including earth lead of copper strip 20 mm X 3 mm by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I connected to earthing test point all as specified or indicated including testing on completion and excavation and earth work in any type of strata, PCC 1:3:6 type C1 in chamber, precast RCC cover 50mm thick in cement concrete 1:2:4 type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4 Kg/Sqm) with cast iron frame, funnel with wire mesh, 20mm bore GI pipe medium grade watering pipe, lugs, 40mm bore GI pipe medium grade protection pipe up to 7.5m complete all as specified and directed by the Engineer-in-Charge NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. Copper strip beyond 7.5 Metre shall be measured and paid for separately. |
| 110 | Material & labour in repairs earthing complete with galvanised steel earth electrode 60cmx60cmx6mm buried directly in ground vertically to depth not less than 2.25m below normal ground level with top edge of the earth plate at a depth not less than 1.5m below ground level connected to and including GI earth strip 32mm x 6 mm, by means of nuts, bolts, check nuts and washer etc, made of GI and connected to test point and earth dolly all as shown in electrical plate No. 3 SSR Part-I 2009 and specified or indicated including excavation and earthwork in any type of soil PCC (1:3:6) Type C1 in chamber, precast RCC 50 mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM (Weight not less than 4.00 Kg/Square metre) with cast iron frame, funnel with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. NOTE :- The rate of above Item includes the cost of earth lead and GI protection pipe up to 7.5 Metres. GI strip beyond 7.5 Metre shall be measured and paid for separately. |
| 111 | Material & labour in repairs for bore earthing 150 mm dia buried by vertical boring machine, depth 50 mtr below ground level using earth electrode 50mm dia GI pipe medium grade duly drilled hole of 12mm dia, 15cm C/C on both side of the pipe including lowering in bore well upto the depth of 49mtr and one metre above the ground level. The pipe electrode should be filled around commercial salt, charcoal dust, copper sulphate and magnisium phosphate of 30 cm layer each upto the full length of pipe. The bore well should have 12 metre of length 150mm dia MS pipe 4.8mm wall thickness for protection of bore well. Welding of GI strip 50x6 mm on earth electrode GI pipe 50mm dia upto the 10 metre below ground level and 25 metre from the bore well to test point gun metal and PCC foundation sorrounding the bore well 60x60x30 cm complete all as specified and directed. Note :- If GI strip required more than 35 metres , than length exceeding 35 metres shall be measured and paid separately. |
| 112 | Material & labour in replacement test point terminal block made of gun metal or phosphorus bronze size 75mm x 75mm x 25mm drilled and screwed including 3 Nos. 8mm dia 25mm long hexagonal head screw as required with all accessories complete all as specified and directed by the Engineer-in-Charge. |
| 113 | Material & labour in replacement copper strip 20mmx3.15mm complete with, protection sleeves, saddles, seperator and fixing screws at surrounding inside and outside the building complete all as specified and directed by the Engineer-in-Charge. |
| 114 | Material & labour in replacement galvanised steel strip 32mmx6mm complete with, protection sleeves, saddles, seperator and fixing screws at surrounding inside and outside the building complete all as specified and directed by the Engineer-in-Charge. |
| 115 | Material & labour in replacement galvanised steel strip 25mmx3.15mm complete with, protection sleeves, saddles, seperator and fixing screws at surrounding inside and outside the bldg complete all as specified and directed by the Engineer-in-Charge. |
| 116 | Material & labour in replacement 35 sqmm multistranded flexible copper conductor (heavy duty) single core includng suitable lugs/GI nut, bolts and mounting accessoreis complete all as specified and directed by the Engineer-in-Charge.The mounting clamp should be of non conductive metarial used in earthing. |
| 117 | Supply & fixing in replacement of Seperator U type, made of porcelain, used for mounting Earth strip, with all nut bolts and connecting accessories complete all as specified and directed by the Engineer-in-Charge. |
| 118 | Dismantling of old unserviceable PCC earthing chamber, and material & labour for construction of PCC chamber made out of PCC 1:2: 4 type B1 using 20mm graded crushed stone aggregate and cover shall be 40mm thick RCC Pit cover made of precast cement concrete cover slab type B-1 (PCC 1:2:4) using 20 mm graded crushed stone aggregate , reinforced with mild steel XPM weighing not less than 4 kg/ Sqm, including necessary form work & surfaces of PCC chamber shall be finished smooth without using extra cement, exposed surfaces shall be given three coats of white wash complete, minimum dimention of PCC Chamber shall not be less than as specified & shown on Plate No 3 of SSR Part I (2009) complete all as specified and directed by the Engineer in Charge. Note : The rate quoted for this item also includes necessary excavation and earth work, disposal of surplus soil/material to a distance not exc. 50 metres complete. |
| 119 | Material and labour for replacement of 20 to 25mm thick kota stone earth pit cover of size 2 feet x 2 feet complete all as specified and directed by Engineer-in-charge. |
| 120 | Material & labour for replacement of single rod chemical earthing, (comprising of one copper rod, chemical earthing), copper electrode of wall thickness minimum 2mm not less than 3 mtrs length not less than 75mm outter dia, fixing of copper earth electrode by drilling/boring 175mm dia hole, 5.00 mtr deep in any type of strata, placing electrode in hole, return filling excavated soil by mixing min 20 kg GEL per bore and 75 kg soil resistivity improvement (SRIP) compound as per manufacturer instruction, including PCC foundation sorrounding pit of size 60x60x30 cm complete all as specifed and directed by engineer-in-charge. |
| 121 | Material & labour in replacement of PVC/rubber pipe/sleeve of dia upto 50 mm for protection of earth strip and insulation purpose complete all as specified and directed by the Engineer-in-Charge. |
| 122 | Supply and fixing in replacement of single pointed air termination aluminium rod 12 mm dia 300 mm long complete all as specified and directed by the Engineer-in-Charge. |
| 123 | Supply & fixing in replacement of 40 mm bore GI tubing medium grade as earth strip protection complete all as specified and as directed. |
| 124 | Supply and fixing in replacement of aluminium strip of size 25 mm x 3.15 mm with saddles and fixing screws etc for roof conductors above ground complete all as specified and directed by the Engineer-in-Charge. |
| 125 | Material and labour for PCC block of size 150 mm x 150 mm x 300 mm, made out of PCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) for fixing/ mounting of running earthing conductor including CM 1:6 complete all as specified and directed by the Engineer-in-Charge. |
| 126 | Supply & fixing in replacement of 15 mm bore GI tubing medium grade laid in trenches or fixed on walls or under floors including necessary fittings complete all as specified and as directed. |
| 127 | S&F in replacement of Gun-metal, globe or gate valves, with iron wheel head, screwed both ends for iron pipe and fixed including fittings 15 mm (1/2”) dia complete all as specified and as directed. |
| 128 | S&F in replacement of self closing bib tap of cast iron or malleable cast iron, Galvanised, screwed for iron pipe and fixed 15mm as specified and directed. |
| 129 | M&L for cutting of existing steel tubing for alteration or additions of size 15 mm including necessary fittings complete all as specified and as directed. |
| 130 | S&F in replacement for installation of earth notice plate of size 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures i.e. pit number, connected to, tested date, ohmic value as per direction by EIC fixed beside earthing pit with GI stand of approved size complete all as specified and as directed by EIC. |
| 131 | M&L for brazing of earthing strip of any size using identical material brazing rods with the help of burner/ welding machine as required at site all as specified and directed by EIC. Please Enable Macros to View BoQ information |