| 1 | Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed . |
| 2 | M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed . |
| 3 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed |
| 4 | M&L for rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. |
| 5 | M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed . |
| 6 | M&L for two coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 3mm thick wall care compound of altek/birla putty for exterior/interior on old scraped wall/ceiling surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed .Note : Colour and make as approved by Engr-in-Charge. |
| 7 | M & L for preparation of old wall surfaces by removal of existing treatment and apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed . |
| 8 | M & L for preparation of old surfaces by removal of existing treatment and apply one coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed . |
| 9 | M&L for providing and laying cement mortar near ground level factory made kerb stone of M-25 grade cement concrete inposition to the required line, level and curvature, jointed with cement mortar 1:3, including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed . |
| 10 | M & L for preparation of old stone, concrete surfaces of any description over 10 CM width or girth and applying one coat of plastic emulsion paint (Weather Coat) on old footpath/colour tiles/ kerb stone etc (colour and pattren as per approved by EIC ) complete all as specified and directed. |
| 11 | Removing/cleaning of silt, mud,etc under culvert and in the drain of any width and length in soft/loose soil including depositing of removed material from site at a distance exc 500 m and n exc 1.5 KM deposited where complete all as specified and directed . |
| 12 | M&L for PCC 1:2:4 type B0 (using 12.5 mm graded stone aggregate) as in coping/benching and all other similar works including necessary formwork complete all as specified and directed . |
| 13 | S&F in repair precast factory made polycrete (SFRC) medium duty perforated drain cover 75-100 mm thick rectangle in shape upto 01 sqm area each with hole for drain complete all as specified and directed . |
| 14 | Demolition of reinforced cement concrete of any descrption and in any position not otherwise specifically provided for complete all as specified and directed. |
| 15 | M&L for providing precast cement concrete (1:2:4 type B-1 with using 20mm graded stone agg) as in landings, cover slabs (for manholes etc). Chulah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces and set in cement mortar 1:4 complete all as specified and directed. |
| 16 | M & L mild steel TMT bars 8 mm & above dia cut to length bent to shape required incl cracking bending spirally, hooking and binding with & incl MS wire 0.9 mm dia etc complete all as specified and directed. |
| 17 | Dismantling of fencing post or strut (wood, steel or RCC) any section, posts embeded in concrete, brick work, masonery etc, including taking out embeded portion in concrete, and making good disturbed ground complete all as specified and directed. |
| 18 | Dismantling of barbed wire any type complete all as specified and directed. |
| 19 | Dismantling of concertina coil of any size any description fixed on posts or angle of any kind all as in fencing complete all as specified and directed. |
| 20 | S&F MS work as in post and strutt and fencing, drilled and countersunk for balusters running bars for doors balusters,noising to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts,posts and struts in fencing including cutting tops to shape as directed drilling hoes nothcing for wire etc flat iron fillets ( for securing wire mesh ) including all necessary drilling bolting or riveting etc. and similar work conforming to Fe - 290 Gde E - 165 as specified and directed. |
| 21 | S&F for plates (Plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attchment confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed. |
| 22 | M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm girth or width and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer complete all as specified and directed . |
| 23 | S&F in repair two strand galvanised steel barbed wire 2.24mm dia barbed with 2mm dia bars @ 75mm spaciang and fixed to any type started rails strained bolts incl securing or tying at closing with and provn of galvanised mild steel wire staples or steel pins, complete all as specified and directed . |
| 24 | S&F for 900/600 mm dia concentrina spiral coil fencing with punched tape and 6 m max openable length, on wall with angle iron Y shaped with 9 horizontal RBT reinforced barbed wire studied with GI staples and GI clips to retain horizontal incl necessary bolts or GI barbed wire tied to angle iron, all complete as per direction of EIC, with reinforced barbed wire tape (RBT)/spring core (2.5 mm thick) wire of tensile strength of 165 kg/sqmm with tape (0.52mm thick) and weight 43.47 gm/m complete all as specified and directed . |
| 25 | M&L in applying two coats of synthetic enamel paint over a coat of red oxide primer to new steel and iron surfaces over 10cm in width or girth including preparation of surfaces complete all as specified and directed . |
| 26 | M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm complete all as specified and directed . |
| 27 | S&F in repair 1.25mm thick Steel rolling shutters, gear operated type with bevel gear box and crank handle, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type incl taking down rolling shutters complete all as specified and directed . |
| 28 | S&F Safety lever locks mild steel with 4 levers incl ball bearing for rolling shutters complete all as sspecified and directed. |
| 29 | M & L for precast cement concrete loveres and jallies, 25mm thick, type B0 1:2:4 (12.5 mm graded), set in CM 1:4, including all mouldings complete all as specified and directed. |
| 30 | S & F for mild steel framed work as in grill, guard bars etc with ends of bars/FI shoulders and or riveted or forged in to spikes, framed guard bars, barred iron doors, ladders, frame work of watertanks and and similar works confirming to Fe 410-0 or Fe 310-0 complete all as specified and directed. |
| 31 | S & F for Expanded metal, exc 4 kg weight per square meter, cut to length, bent to shape required and tying with and including annealed mild steel wire not less than 0.9mm dia or fixing with galvanised steel stables supplid and fixed complete to wood or steel members complete all as specified and directed. |
| 32 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and as directed. |
| 33 | M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm agg. ) as in plinth protection / path/ any paved area complete all as specified and directed. |
| 34 | Dismantling of existing roof treatment of any description/thickness including dismantling of water proofing plaster etc complete all as specified and directed . |
| 35 | M&L for PCC 1:2:4, type B-0, using 12.5mm graded stone aggregate coping, benching, roof padding as levelling course complete all as specified and directed . |
| 36 | M&L for 15 mm thick cement plastering in CM 1:4 on brick/concrete surfaces of roof and parapet, mixed with water proofing compound, finished even and smooth without using extra cement (Including 4 Story building) complete all as specified and directed . Note :- Water proofing compound shall be measured & paid separately. |
| 37 | Supply only liquid water proofing compound complete all as specified and directed . |
| 38 | Cleaning top surfaces by brooming, wire brushing, removing grass, raking out joints to receive plaster and removing debris, grass etc outside the defence land complete all as specified and directed . Note :- 1. Plaster shall be measured and separately under appropriate item of Sch ‘A’. 2.Rate of this item is inclusive of diconnect fitment at water tank or solar heater etc and refixing in the same position after compeleting of roof treatment. |
| 39 | M&L for applying 3.00mm thick APP based polymer membrane over 85/25 industrial bituminous coat @ 1.2 Kg/Sqm over bituminous primer @ 0.30 Ltr/Sqm on newly plastered clean and dry roof surface. Top surface shall be finished with bituminous base Aluminium paint, all joint shall be Sealed by torch application complete all as specified and directed .Note:-(a) Contractor has to provide labour for attending the complaints/ performing the work, as required during any time of the contract period .(b) Contractor has to perform work at scattered location and on different time line in the station during the contract period.(c) The rate is inclusive of work done upto to 4 storey building.(d) The contractor has to make good of disturbed surfaces and remove the taking down materials/ debirs from defence area. The rate of taking down, bringing the vehicle and removing the debris is inclusive of quoted rartes. |
| 40 | Removing daberies/excavated material to a distance exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed . |
| 41 | M&L for Washed stone grit plaster on exterior walls in two layers, under layer 12mm cement plaster 1:4 (1 cement: 4 coarse sand) furrowing the under layer with scratching tool, applying cement slurry on the under layer @ 3kg of cement per square metre, top layer 15mm cement plaster 1:1/2:2 (1 White cement: 1/2 coarse sand: 2 stone chipping 10mm nominal size) in panels with groove all around as per approved pattern including scrubbing and washing, the top layer with brushes and water to expose the stone chippings complete all as specified and directed .Note : Payment for providing grooves shall be made separately. |
| 42 | M&L for forming groove of uniform size 15mm wide and 15mm deep in the top layer of washed stone grit plaster as per approved pattern using wooden battens, nailed to the under layer including removal of wooden battens, repair to the edges of panels and finishing the groove complete all as specified and directed . |
| 43 | M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base complete all as specified and directed . |
| 44 | M&L for 60 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment,(M-35) grade any clours as approved by EIC /GE complete all as specified and directed |
| 45 | M&L for 80 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment ,(M-40) grade any clours as approved by EIC /GE complete all as specified and directed |
| 46 | M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed . |
| 47 | M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed . |
| 48 | M&L for 25 mm thick PCC type B-0, 1:2:4 (using 12.5 mm graded stone aggregate) as in laying of floor/sub base finishes complete all as specified and directed . |
| 49 | M & L for PCC 1:2:4 Type B-2 (using 40mm graded stone aggregate) as in flooring incl finishing the cement concrete surface even and smooth with using extra cement , rubbish off the primises and incl demolition complete all as specified and directed . |
| 50 | Dismantling floor, stone, hearth or wall tiling including cement mortar bedding but not backing, removing serviceable tiles to store and rubbish off the premises complete all as specified and directed . |
| 51 | M&L for Glazed ceramic coloured tiles in vertical surface 350 x250x 7 mm/ 450x 350x7 mm thick set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of the Tiles, complete all as specified and directed . |
| 52 | M&L for 15mm thick screed bed in cement mortar 1:4 Laid and Jointed in Neat Cement Slurry for under floor tiles etc complete all as specified and directed . |
| 53 | Dismantling wrought iron or mild steel work of any description not otherwise provided for, complete all as specified and directed . |
| 54 | S&F Welded steel wire fabric supplied and fixed, complete to wood or steel menbers not exc 4.00 kg per sqm, complete all as specified and directed . |
| 55 | S&F in repairs for 4 mm thick polycarbonate sheet of any colour as in fencing/roof covering/cladding to wall fixed with coach screws and washers over Aluminium cover Strip 40x3mm and rubber washer in each joint including dismantling existing sheet complete all as specified and directed . Please Enable Macros to View BoQ information |