| 1 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 2 | M&L for rendering 15 mm thick cement plaster in CM 1:6 on brick Work or concrete surfaces including finished even and smooth without using extra cement complete all as specified and directed. |
| 3 | M&L for rendering 15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. |
| 4 | M&L for rendering 10mm thick in CM 1:3 over concrete surface as on ceiling, chhajja, shelves etc to match with existing surfaces finish even and smooth w/o using extra cement complete all as specified and directed. . |
| 5 | M&L for 15mm thick ready mix plaster CM (1:6) on brick/concrete/stone wall surfaces including finishing the surfaces fair and even (without using extra cement) and smooth as per manufacture direction complete all as specified and directed. |
| 6 | M&L for 10 mm thick ready mix plaster CM (1:3) on brick/concrete/stone wall surfaces including finishing the surfaces fair and even (without using extra cement) and smooth as per manufacture direction complete all as specified and directed. |
| 7 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on wall over one coat of primer incl one layer of 1mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 8 | M & L for preparation of new plastered surface and applying two coats of oil emulsion distemper on ceiling over one coat of primer incl one layer of 1mm thick wall care putty on new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 9 | M&L for preparation of new treated plastered on wall surfaces and applying two coats of weather proof exterior emulsion (water based) paint of dark or light colours/shade on walls (shade as approved by GE) over applying plaster of paris putty of 1 mm thickness over plastered surface to prepare the surface even and smooth exterior/interior on wall surface complete all as specified and directed. |
| 10 | M&L for one coat of Acrylic smooth exterior emulsion paint over one coat of acrlic primer incl one layer of 1 mm thick wall care compound of altek/birla putty for exterior/interior on old scraped wall/ceiling surfaces and obtain smooth finish using sand paper complete all as specified and directed. Note : Colour and make as approved by Engr-in-Charge. |
| 11 | M&L for preparation of old surfaces by removal of existing treatment and applying two coats of oil emulsion distemper over a coat of primer on surface of walls incl one layer of 1mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as specified and directed. |
| 12 | M&L for preparation of old surfaces by removal of existing treatment and applying two coats of distemper oil emulsion on ceiling over one coat of primer incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as spd and directed. |
| 13 | M&L for preparation of old surfaces by removal of existing treatmen and applying one coats of oil emulsion distemper over a coat of primer on surface of walls incl one layer of 3mm thick wall care putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as spd and directed. |
| 14 | M&L for preparation of old surfaces by removal of existing treatment and applying one coats of distemper oil emulsion on ceiling over one coat of primer incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as spd and directed. |
| 15 | M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth exc 10cm complete all as specified and directed. |
| 16 | M & L for one coat of synthetic enamel paint on steel surface including preparation of old steel surface width or girth n. exc 10cm complete all as specified and directed. |
| 17 | M&L for one coats of synthetic enamel paint on wooden surfaces of any description over 10cm width or girth including preparation of old surfaces complete all as specified and directed. |
| 18 | M&L for Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and complete all as specified and directed. |
| 19 | M&L for 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, complete all as specified and directed. |
| 20 | M&L for non skid ceramic coloiured tiles 7 to 8 mm thick (square/rectangular ) area of each tile exc 0.11 Sqm but not exc 0.16 Sqm as in floor of shade & designed as approved by GE,set and jointed in neat cement slurry and pointed with white cement with colour pigment to match the colour of tiles,15 mm thick rendering in bedding layer or screed bed in cement mortar (1:6) in floors incl dismantling tiles etc complete all as specified and directed. |
| 21 | M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 bed,complete all as specified and directed. |
| 22 | M& L for Glazed ceramic jointless coloured group of size 300/350mmx450/600mm, thickness not less than 6mm as in vertical surfaces such as skirting/dado etc., set and jointed in neat cement slurry and pointed with white cement and pigment to match, laid over and including 10mm thick plastering in cement mortar 1:4, incl dismantling tiles etc complete all as specified and directed.Note : shade & design as approved by EIC/GE . |
| 23 | M&L for Vitrified tiles light shade 10 mm thick (square/ rectangular) polished, area of each tiles exc 0.42 sqm and n exc 1 sqm , in floors, dado , skirting etc. set and jointed in neat cement slurry over 15 mm thick screed bed or bedding layer in CM 1:4 for laying floor finishes and pointed in white or coloured cement to match and incl dismantling tiles etc complete all as specified and directed. |
| 24 | M & L for viterous china squating pan of (Orrissa Pattern) size 580x440 mm white with 'P' or 'S' trap front or back inlet and integral foot rest (excluding flushing cisteern and flush pipe) fixed in repair including lime concrete bedding as required set complete all as specified and directed. |
| 25 | S&F for Vitreous China wash down water closet pan (pedestal pattern) with trap, white (excluding fixing bolts, flushing cistern and flush pipe) incl connection to drain and flushing pipe in repairs complete all as specified and directed. |
| 26 | S&F of PVC flushing cistem low level white with all accessories of 10 ltrs capacity incl flushing pipe, brackets and taking down of old CI/PVC flushing cistern in repairs complete all as specified and directed. |
| 27 | Taking up or down 15 mm dia bore steel tubing and connection including cleaning for refixing or removed to store complete all as specified and directed. |
| 28 | S&F for GI tubing 15mm bore medium grde with all fittings and fixed complete to wall and ceiling or laid in floors etc incl cutting chases in brick wall pinning in making good in CM 1:3 to facings where required complete all as specified and directed. |
| 29 | S&F GI tubing 15 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. |
| 30 | Taking up or down steel tubing and connection including cleaning for refixing or removed to store, 20 mm dia bore complete all as specified and directed.. |
| 31 | S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. Please Enable Macros to View BoQ information |
| 32 | S&F GI tubing 20 mm bore medium grade medium grde with all fittings and fixed complete to wall and ceiling or laid in floors complete all as specified and directed. Please Enable Macros to View BoQ information |