| 1 | Scooping & taking out sludge, sludge and foreign materials from manhole, septic tank, soak wells of any description and depth including removing and refixing of accessories and appliances required for safe disposal of sludge, sludge and foreign materials either by carrying the same in covered van/trolley outside defence land and disposed off at such place which is not determinated to public health complete all as specified and directed.Note: Depth shall be measured for payment after balling out water and the rate quoted demmede to be inclusive of cost required for balling out water. |
| 2 | Cleaning of mantholes not exc. 1.5 Mtr deep including desludging and dewatering either by mechanical pump or manually and taking out solids semi solids, well flushing with water, removing to a distance upto 250 Mtr and depositing in ditches. including necessary excavation and earth work in soft/lose soil for making ditches over after the sludge are deposited spreading and levelling of excavated soil in the ditches over the sludge and removing surplus soil to a distance exc. 50 Mtr and sprinkling bleaching powder (including supply of bleaching powder) in a periphery of one metre around manhole complete all as specified and directed. |
| 3 | All as per srl item No. 2 above but depth exc. 1.5 Mtr and not exc. 3.00 Mtr complete all as specified and directed. |
| 4 | Cleaning and rodding the blocked sewage line of 150mm bore dia to any depth till the smooth flow of sewage line is restored including plugging of manholes temporarily as and when required and washing down complete sewage line with water including removing sludge and foreign materials from manholes in line and refixing manhole covers and rodding complete all as specified and directed. |
| 5 | All as per item No. 4 above but 200mm bore dia complete all as specified and directed. |
| 6 | All as per item No. 4 above but 300mm bore dia complete all as specified and directed. |
| 7 | Taking down grating and cleaning blocked Nahani trap/floor trap/gully traps of any size by rodding or vacumme pump and refixing grating after clearing of blockage complete all as specified and directed. |
| 8 | Cleaning blocked water closet of any description by rodding or vacumme pump complete all as specified and directed. |
| 9 | Excavation in trenches not exc 1.5 Mtr wide and not exc 1.5 Mtr in depth for foundations, manholes etc and getting out in hard/dense soil complete all as specified and directed. |
| 10 | Excavation in trenches not exc 1.5 Mtr wide and exceeding 1.5 Mtr depth but not exc 3.00 Mtr depth for foundations, manholes etc and getting out in in soft/disintegrated rock complete all as specified and directed. |
| 11 | Returning, filling in, including spreading, levelling watering and well ramming in layers not exc 25cm in soil complete all as specified and directed. |
| 12 | Removing the excavated materials (soil) to a distance n, exceeding 50 Mtr and depositing where directed at a level not exc 1.5 Mtr above the starting point complete all as specified and directed. |
| 13 | M&L for 150mm bore dia RCC pipes class NP-2 with socketed ends laid and jointed complete with rubber ring joints of complete all as specified and directed.Note: Laying of sewage line in running sewage water & temporary diversion/plugged of existing sewage line & bailing of sewage water is the responsibility of contractor and the rate quoted shall deemed to be included in the item including Demolition and breaking up RCC drain pipes 150mm bore dia set in cement mortar and removing debris from the site complete all as specified and directed. |
| 14 | All as per item No. 13 above but 200mm bore dia complete all as specified and directed. |
| 15 | All as per item No. 13 above but 300mm bore dia complete all as specified and directed. |
| 16 | M&L for Cement Concrete bed to drain pipes, 1:4:8, type D-2 using 20mm graded stone aggregate including forming cradles; in for 150mm bore dia pipe complete all as specified and directed. |
| 17 | All as per item No 16 above but for 200mm bore dia pipe complete all as specified and directed. |
| 18 | All as per item No 16 above but for 300mm bore dia RM pipe complete all as specified and directed. |
| 19 | Cutting into existing manholes for connecting new drains of 150mm bore dia making good to pipe and rendering, cutting out existing benching for and forming branch channel (1/2 round or 3/4 Section) in cement concrete 1:2:4 type B-1 smooth finished, and reforming benching as required complete all as specified and directed. |
| 20 | Demolition of cement concrete (reinforced) in any description complete all as specified and directed. |
| 21 | M&L for providing precast cement concrete 1:2:4 type B-1 using 20mm graded stone aggregate as in cover slabs for manholes/drains etc set in CM 1.4 complete all as specified and directed. |
| 22 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking. bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 23 | M&L for precast cement concrete block masonry exceeding 10cm in width witth solid blocks of PCC (1:5.8) grade D-5 and set in in CM 16 including dismantling of old brickwork or stone/boulder/PCC block masonry built in cement mortar complete all as specified and directed. |
| 24 | M&L for PCC 1:2:4 type B-1 using 20 mm graded stone aggregate as in cills, steps, bands, plinth courses, string courses, lacing courses, coping kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles etc complete all as specified and directed. |
| 25 | Rendering 15mm thick in cement mortar on fair faces of brick/concrete surfaces finished surfaces even and smooth using extra cement complete all as specified and directed. |
| 26 | S&F in repairs 75mm bore dia PVC floor trap with SS grating including jointing with solvent cementof complete all as specified and directed. |
| 27 | Material and labour for Non skid coloured ceramic tiles of size 300mm x 300mm x 10mm thick (Square/rectangular) over & including 15mm thick screed bed in CM (1:6) in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match the tiles including dismantling of tiles complete all as spceified and directed. |
| 28 | M&L for Glazed ceramic tiles 300x450x7 mm thick including 10 mm rendering CM 1:4 in vertical surface set and jointed in neat cement slurry and painted in white or colour cement to match and including dismantling floor heath or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as spceified and directed. |
| 29 | S&F 15 mm dia steel water Gi tube medium grade with all fittings/connections & MS clamps/clips and necessary screwing as reqd and fixed with or without concealed to walls & surface of roof slab including taking down the existing pipe of any type complete all as specified and directed. |
| 30 | S&F in repair vitreous China, squatting pan, Orissa Pattern, size 580 x 440 mm white, with integral foot rests (excluding flushing cistern and flush pipe) with PTMT trap of suitable size (Por S type) including connection to trap and to flushing pipe, anti syphonic pipe etc complete including provision of cement concrets bedding & making good to floor complete all as specified and directed including taking out old one. |
| 31 | S&F in repair Vitreous China wash down water closet pan (pedestal pattern), white with Por Strap with and including plastic water closet seat cover, jet spray, connection to trap, flushing pipe & anti-syphonage pipe etc including necessary materials for fittings & making good to floor complete all as specified and directed. |
| 32 | S&F in repairs 10 Ltr capacity PVC valveless syphonic action type flushing cistern low level white, with inlet, ball valve, float and handle including PVC flush pipe and brackets complete fixed in wall and floor to trap of WC as reqd complete all as specified and directed. |
| 33 | S&F in repairs vitreous china wash hand basin, white, flat back of size 550mm x 400mm with & including a pair of pre-painted cast iron brackets embedded in PCC 1:3.6 type C1 blocks of size 10x7.5x15cm, 32 mm dia PVC waste pipe and 32mm bore PTMT waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead coment & other end fixed, (excluding tap, waste chain & plug), complete all as specified and directed. |
| 34 | S&F in repair 15 mm bib tap (fancy type), cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 35 | S&F in repair 15 mm angle cock (fancy type), cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed. |
| 36 | S&F brass chromium plated shower roses of size 125mm with or without swivel joints, any size, including shower arm 15mm size, 195mm long bend of 45degree with flange of CP fixing to steel pipe or union complete all as specified and directed. |
| 37 | S&F 15 mm dia PVC connections, 450 mm long with PTMT nuts of suitable size at two end complete all as specified and directed. |
| 38 | S&F in repair chromimum plated 15mm bore pillar taps with capstan head (but fancy type) screwed down high pressure with or without lettered Hot or cold with long screwed shank and fly nuts screwed for iron pipe and fixed complete all as specified and directed. |
| 39 | S&F in repair Brass CP mixer for mixing hot & cold water screwed down for iron pipe and fixed complete all as specified and directed. |
| 40 | S&F 110mm bore dia PVC (SWR) pipes single socheted in any length with rubber ring joints fixed to wall or laid in floors/in trenches including demolition of pipes complete all as specified and directed. |
| 41 | S&F 75mm bore dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall or laid in floors/in trenches including demolition of pipescomplete all as specified and directed. |
| 42 | S&F 110mm bore dia PVC (SWR) bends plain any radius complete all as specified and directed. |
| 43 | S&F 75mm bore dia PVC (SWR) bends plain any radius complete all as specified and directed. |
| 44 | Demolition of cement concrete in ground floors and paving n exc 15cm (below or above ground) and inclusive of removal of debris out side defence land complete all as specified and directed. |
| 45 | M&L for Cement concrete type D2 1:4:8 (using 40mm graded stone aggregates) in foundations, filling and mass concrete & sub base of flooring complete all as specified and directed. |
| 46 | M&L for rubber moulded glossy chequered cement concrete tiles 30cm x 30cm x 20mm thick, sel, jointed and pointed in neat cement slurry with grey cement and no pigments in floors over and including 20mm thick screed bed in cement mortar 1:6 complete all as specified and directed. |
| 47 | M&L for Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks lawms, drive ways or light traffic parking etc. of required strength, thickness & size/shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra complete all as specified and directed. |
| 48 | M&L for 100mm thick PCC 1:2:4 type B1 (using 20mm graded coarse stone aggregates) as in hard standing/road crossing area of sewage line complete all as specified and directed.Note: (a) Day to day maintenance and petty repair of sewage line (complaints pretaining to safaiwala) by attending daily complaints lodged by the users through IVRS/mobile/sms/or email and manual registratering of complaints at B/R complaint cell of AGE B&R-il on all working days (except sunday, National holidays and closed holidays) by deploying safaiwala daily complete all as specified and directed. (a) Each complaint shall be completed within 24 hours(b) If safaiwala not attended complaint within time frame mentioned above 50% shall be deducted job completed by him. (c) The contractor will be responsible to maintain daily job completed by the safaiwala deputed by him in the sub work and obtained signature of VC complaint cell/Engr-in-Charge daily at 1700 hours on all working days. Please Enable Macros to View BoQ information |