| 1 | Demolition/Dismantling of Brickwork or stone/ boulder masonry, built in cement mortar incl all quoins, arches, pillars, etc, complete all as specified and directed . |
| 2 | M&L for Brickwork with subclass 'B' bricks (old size bricks), straight or curved on plan exc 6m mean radius, built in CM 1:6 complete all as specified and directed . |
| 3 | Taking down cement plaster of any description on concrete surfaces such as soffit of RCC slab, chajjas and brick walls, Ceiing etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed . |
| 4 | M&L for rendering in foul position (Shaft Area),15mm thick in CM 1:4 on of brick work or concrete surface finish ever and smooth (w/o using extra cement) incl WPC as per user manual complete all as specified and directed. |
| 5 | M&L for preparation of new plaster surface & apply two coats of cement based paint over a coat alkali primer resistance incl one layer of 3mm thick wall care compound of altek/birla putty on old scraped surfaces or new plasterd surfaces and obtain smooth finish using sand paper complete all as spd and directed. |
| 6 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15cm thickness (below or above ground level) including floor finishes/tiling work and disposal of debris complete all as specified and as directed. |
| 7 | M & L for 50 mm thick PCC 1:3:6 type C-2 (using 40 mm graded stone agg. ) as in plinth protection / path/ any paved area complete all as specified and directed. |
| 8 | M&L 75mm thick PCC type D-2, 1:4:8 (using 40mm graded aggregate) as in sub base all as specified and directed. |
| 9 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658 -2006 of 60mm thickness, with grey cement, pigment incl 25mm thick sand filling complete all as specified and directed. |
| 10 | M&L for 80 mm thick machine cut precast concrete inter locking paver block with grey cement and pigment ,(M-40) grade any clours as approved by EIC /GE complete all as specified and directed |
| 11 | M & L for sand filling under floors or in foundation including watering and consolidation complete all as specified and directed . |
| 12 | M & L for chequered tiles of size 300 x 300 x 25 mm thick (colour and glazed approved by EIC) with grey cement and pigments laid over 15 mm thick screed bed in CM 1:6 bedded and jointed in neat cement slurry, incl dismantling complete all as specified and directed. |
| 13 | Cleaning /removal of blockage 150 mm bore SWG pipes of depth not exc 1.50 mtr with mechnical process incl removing RCC man hole covers and refixing the same as before complete all as specified and directed . |
| 14 | Cleaning /removal of blockage 300 mm bore SWG pipes of depth exc 1.50 mtr but not exc 3.00 mtr with mechnical process incl removing RCC man hole covers of any size, and refixing the same as before complete all as specified and directed . |
| 15 | Dewatering/desilting of existing manholes of any size depth and removing of all solid/semi-solid matter of silt residue both organic or inorganic in nature (mechanical system or using suction pump where ever required up to any depth )and incl removing RCC manhole Covers and refixing the same after making the manhole fully functional, complete all as specified and directed . |
| 16 | Dewatering/desilting for the septic tank of any capacity exc1.50 m and n.exc 4.5 m deep solid/semi-solid matter of silt residue both organic or inorganic in nature ( mechanical system or using suction pump where ever required up to any depth by working under foul conditions and disposal of the same in out of MoD area, complete all as specified and directed .Note for Item : The Septic tank shall be measured more than one time as per requirment and directed by Egnr-in-Charge. |
| 17 | Excavation in trenches n exc 1.5m wide and n exc 1.5m deep and getting out in soft or loose soil for shafts, wells,drains, manholes etc n exc 10Sqm on plan for sewage line & foundation etc complete all as specified and directed . |
| 18 | All as per item No 17 but exceeding 1.5 M depth and not exceeding 3 M for shafts, wells,drains, manholes etc., and getting out in Soft/ Loose soil. |
| 19 | Demolition and breaking up drain pipes 100mm dia ( Salt Glazed ware, AC or reinforced concrete) set in cement mortar including PCC bed and haunching and removal of debris outside the MD land complete all as specified and directed . |
| 20 | Demoltion and breaking up existing sewag(SWR/ AC pipes and the like, 150mm bore set in cement mortar and removing demolished material to a distance exc 50m and n exc 100m complete all as specified and directed . |
| 21 | S&F 110 mm PVC (SWR ) , pipes single socketd , in any length with rubber ring joints , laid in trenches or in floor complete all as specified and directed . |
| 22 | S & F for sail glazed stoneware, 150 mm bore drain pipes laid and jointed complete all as specified and directed . |
| 23 | M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 100 mm bore complete all as specified and directed . |
| 24 | M & L for PCC 1:3:6 type C2 (using 40 mm graded granite stone aggregate) in concrete bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested for pipes of 150 mm bore complete all as specified and directed . |
| 25 | S & F in repair for precast factry made reinforced cement concrete Manhole cover (Ist quality) including grove and hook arrangement for lifting and placing in position and sides covered by MS sheet medium duty of 60mm thick (size of the cover will be itimated by the Engineer-in-Charge) complete all as specified and as directed. |
| 26 | Returning, filling in soil including spreading, levelling, watering and well ramming in layers n.exc. 25cm complete all as specified and directed . |
| 27 | M&L for Plain cement concrete (1:2:4) Type B-1, (using 20mm graded crushed stone aggregate), as in copings, kneelers , apex stones,bed plates, including weathering ,slightly rounded /benching or chamfered angles and throating , complete all as specified and directed .Note: Rates include for use of formwork. |
| 28 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 100mm dia pipe complete all as specified and directed . |
| 29 | Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 round section) in cement concrete 1:2:4 type B1, smooth finished and reforming benching as required, 150mm dia pipe complete all as specified and directed . |
| 30 | M&L for cement concrete 1:3:6 type C2 (using 20 mm graded stone aggregate) as in surface channels, drains and bed of manhole complete all as specified and directed . |
| 31 | S&F for 100mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc incl taking down old pipe complete all as specified and directed . |
| 32 | S&F for 75mm bore Cast iron soil, waste and vent pipes, in any length with or without ears, with cement joints, fixed to walls etc complete incl taking down old pipe complete all as specified and directed . |
| 33 | S&F for 100mm bore CI bends fitted with oval access doors (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed |
| 34 | S&F 75mm bore CI bends fitted with oval access doors (any radius), diminishing pieces or tapers (larger bore measured) complete all as specified and directed . |
| 35 | S&F for 100mm branch pieces/T section fitted with oval access doors, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches/ Tee etc complete all as specified and directed . |
| 36 | S&F for 75mm branch pieces/T secction fitted with oval access doors, single (equal or unequal), ordinary or inverted (spigot or socket type) or with parallel branches/ Tee etc complete all as specified and directed . |
| 37 | S& F for 75 Cast Iron Cowl complete all as specified and directed . |
| 38 | S& F for 100 Cast Iron Cowl complete all as specified and directed . |
| 39 | S&F for 75mm dia cast iron socket (double collars) including jointing to pipe complete all as specified and directed |
| 40 | S&F for 100 mm dia cast iron socket (double collars) including jointing to pipe complete all as specified and directed |
| 41 | S&F for 110mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length \\"medium grade \\" with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed |
| 42 | S&F for 110mm bore PVC bends/junction any radius complete all as specified and directed. . |
| 43 | S&F for 110mm bore PVC bends/junction with access door any radius complete all as specified and directed. |
| 44 | S&F for 75mm dia PVC (SWR) multi floor trap, plain with grating including jointing with solvent cement complete all as specified and directed. . |
| 45 | S&F for 75 mm bore PVC pipes single socketed Pressure rating @4Kg/Sq cm length \\"medium grade \\" with rubber ring joint, fixed to walls with dash ture nut and bolt at every 2 mtrs length complete , incl taking up/down old pipe with all fittings complete all as specified and directed |
| 46 | S&F for 75 mm bore PVC bends/junction any radius complete all as specified and directed |
| 47 | Demolition of reinforced cement concrete in roofs, floors (other than ground floors), beams, chajjas, fascias, fins and similar works complete all as specified and directed |
| 48 | M&L for reinforced cement concrete 1:2:4 type B-1 (using 20mm graded stone aggregate) as in landings, cover slabs ( for manholes etc.), shelves and similar articles with plain faces including necessary form work, set in cement mortar 1:6 complete all as specified and directed. Note : Reinforcement shall be measured and paid for separately under respective item of schedule 'A'/BOQ. |
| 49 | S&F TMT MS bar 10 mm dia & over, cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and directed |
| 50 | S&F TMT MS bar 6 to 8 mm dia , cut to length, bent to shape required, including cranking, bending, spirally for hooping for columns, hooking ends and binding with and including MS wire ( annealed) not less than 0.9 mm dia complete all as specified and directed |
| 51 | M&L for RCC Nominal mix(1:2:4) type B0 using 12.5mm graded stone aggregate as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and as directed. |
| 52 | M&L for use and waste of form work Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thickto bottom and sides of slab, for rough finished flat surface of concrete complete all as specified and directed |
| 53 | Removing daberies/excavated material to a distance exceeding 1.5KM but not exceeding 5 KM and depositing where directed at a level n. exc 1.50 m above the starting point complete all as specified and directed |
| 54 | Taking down chowkats or frame with shutters (without taking off shuttters from frames) size exc 1.5 Sqm but not exc 4 sqm each each and removing from site and making good disturbed surfaces as per existing specifications complete all as specified and as directed. |
| 55 | Taking down chowkats or frame with shutters (without taking off shuttters from frames) size n .exc 1.5 Sqm and removing from site and making good disturbed surfaces as per existing specifications complete all as specified and as directed. |
| 56 | Supply and fixing in repairs Harrison rails 20 mm dia mild steel chromium plated curtain rail fixing with brackets stops complete all as specified and directed. |
| 57 | Dismantling wall and ceiling boards (fibre, pulp, insulation etc) any thickness, including cover fillets and grid frame work complete all as specified and directed |
| 58 | S&F for 5mm thick Plain colour PVC wall lining consisting of PVC sheet inclusive of Solvant Cement and fixing at site on PVC frame all as Specified and as directed |
| 59 | S&F 35x5mm PVC Fillet PVC Sheet fixed for wall panelling all as specified and as directed |
| 60 | M & L anodised aluminium snap grid frame work of size 605 x605mm for false ceiling including hanger 6mm dia GI (upto 1200mm length) adjusting level fixed to roof slab by means of ceiling cleats made out of GI flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5 mm dia 40mm long complete all as specified and directed |
| 61 | M&L for 8 mm thick Exposed metal frame ceiling with calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre for fixing in 600 mm x 600mm grid complete all as specified and directed. |
| 62 | Supply and fixing powder coated aluminium door shutters, aluminium section weighting 0.55 Kg/ RM including necessary jointing cleats, glazing clips, rubber neoprene packing, handles 2 Nos in each door, hinges, powder coated aluminium snap beading screws etc complete all as specified and as directed. |
| 63 | Supply and fixing for powder coated aluminium window and ventilator shutters with aluminium grill, side hund type without sash bars aluminium section weighing 0.55Kg/RM including necessary hointing cleats, glazing clips, rubber packing anodised aluminium snap beading, screws anodised aluminium fitting such as peg stay 150mm long (01no) hinges type B21, 100mm long (02 Nos) suitable handle (01 No) complete all as specified and directed |
| 64 | Taking down of aluminium partition including glass and particle board etc complete all as specified and directed. |
| 65 | Supply and fixing for powder coated aluminium partition fixed type/with out sash bars aluminium section weighing 0.55kg/RM incl necessary jointing cleats, glazing clips rubber packing aluminium snap beading, screw etc complete all as specified and directed. |
| 66 | Supply and fixing powder coated aluminium frame for doors, windows ventilators with one or more rebates including jointing cleat for fixing etc complete all as specified and as directed. |
| 67 | Supply and fixing ordinary quality sheet glass 5mm thick in panels of aluminium door and window etc fixed with aluminium clip and rubber beading all as specified n exc 0.5 sqm complete all as specified and directed. |
| 68 | Supply and fixing ordinary quality sheet glass 5mm thick in panels of aluminium door and window etc fixed with aluminium clip and rubber beading all as specified exc 0.5 sqm complete all as specified and directed. |
| 69 | Material and labour for 9mm thick Prelaminated particle, board, exterior grade, prelaminated both side with both side decorative choice laminations fixed with screws/beading to timber/aluminium frame work complete all as specified and directed. |
| 70 | Supply and fixing in repair aluminium (die cast) body door closer hydraulically regulated designation No.3 universal type suitable for aluminium door shutters of width 851 to 1000mm and of weight between 61 to 80Kg complete all as specified and directed. |
| 71 | Supply and fixing for double action floor spring hydraulically regulated made ou of minium 1.25mm thick aluminium allooy sheet foundation box, main body with stainless steel cover governing pivot made of brass, other parts made of MS heavy duty and fixed complete all as specified and directed. |
| 72 | Material and labour for 12mm thick Prelaminated particle, board, exterior grade, prelaminated one side with decorative choice laminations & other side balancing white lamination, fixed with screws to timber frame work and fixed in repairs complete all as specified and directed. |
| 73 | S&F in repair 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n.exc 0.5 sq.m in each pane complete all as specified and directed. |
| 74 | S&F in repair 4 mm thick sheet glass ordinary quality and glazing with oil putty in square exc 0.5 sq.m in each pane complete all as specified and directed. |
| 75 | S&F in repair Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed with stainless steel wire staples complete all as specified and directed. |
| 76 | Note :- Contractor shall be bounded to carryout repair / maint upto G+3 storey building and the rate shall be deemed including scafolding / double scafolding, safety equipments and misc accessories. Please Enable Macros to View BoQ information |