| 1 | Taking down cement plaster on brick or stone walls etc including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 2 | Demolition of brick work or stone/boulders masonary, built in cement mortor including all quoins, arches pillars, etc but excluding ashlar facing dressed stone work and precast concrete articles complete all as specified and directed. |
| 3 | Dismantling posts or struts ( wood, steel or RCC) embedded in concrete, brick work etc, any section and any length including taking out embedded portion and making good disturbed ground complete all as specified and directed by Engineer-in-Charge. Note :- Dismantling of existing galvanised iron steel barbed wire/ chain link fencing shall be measured and paid for separately. |
| 4 | Dismalting chain link fencing of any description fixed to any type of fencing posts complete all as specified and directed by Engineer-in-charge. |
| 5 | Excavating in post holes (or similar holes) each not exc 0.50 cum in soft / loose soil, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25cm, watering, and removing surplus soil to a distance n.exc 50 m and making good surface complete all as specified and directed by Engineer-in-charge. |
| 6 | Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) and removing rubbish off premises complete all as specified and directed. |
| 7 | Demolition of stone slabs and tiles of any description or thickness in floors, aprons etc, laid, bedded, jointed and pointed in any mortar complete all as specified and directed by Engineer-in-charge. |
| 8 | Dismantling AC / fibre sheet any description as in roofs etc including ridges complete all as specified and directed by Engineer-in-charge. |
| 9 | Demolition of cement concrete (unreinforced) in ground floors and pavings not exceeding 15 cm thick above or below ground level complete all as specified and directed. |
| 10 | Demolition of cement concrete (reinforced) of any description and in any position not otherwise specifically provided for reinforcement cut as required to facilitate demolition) complete all as specified and directed by Engineer-in-charge. |
| 11 | M&L for Brick work with sub class ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-charge. |
| 12 | All as per Srl item No 11.00 here-in-before but except brick.Note : Old serviceable brick retrieved from serial item No 2.00 of BOQ here-in-before shall be used under this item. |
| 13 | M&L for brick work with sub class ‘B’ old size burnt bricks in brick-on-edge walls (Less than 1/2 brick thick) built in CM (1:4) complete all as specified and directed. |
| 14 | M&L for glazed ceramic tiles (coloured) 450mm x 300mm x 7mm thick on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick rendering in cement & sand mortar (1:4) including necesary cutting as per site requirment complete all as specified and directed by Engineer-in-charge. |
| 15 | M&L for 18-20 mm thick Granite (of any type) work (table rubbed and polished) for Shelves (veneering to wall) including 15mm thick plaster in cement mortar (1:3) and pointing with white cement (1:2) using marble dust with admixture of pigment to match with shade of granite complete all as specified and as directed. |
| 16 | M&L for 40mm thick (measured solid) precast cement concrete louvers and jallies type B-0 mix (1:2:4) (using 12.5mm graded stone aggregates) including all mouldings but excluding frame set in CM (1:4) complete all as specified and directed. |
| 17 | M&L for rendering 15mm thick on fair faces of brick work/internal faces in man holes in CM 1:4 mixed with water proofing compound @ 200ml by weight of cement per 50 kg including finishing the surface even and smooth without using extra cement all as specified.Note : Supply of WPC shall be measured and paid separately. |
| 18 | Supply only liquid water proofing compound ISI marked complete all as specified and directed by Engineer-in-charge |
| 19 | S&F 70-80mm thick factory made precast RCC manhole / drain covers including frame made up of 40x40x6mm angle, of any size & shape (Squre /rectangular /circuler), heavy duty, out side, fixed at site etc complete all as specified and as directed. |
| 20 | M&L for reinforced cement concrete (nominal mix) (1:2:4) type B1, using 20mm graded stone aggregate for slab supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and other similar works complete all as specified and directed and directed. |
| 21 | Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping) for rough finished of flat surface complete all as specified and directed. |
| 22 | M&L for TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 23 | S&F MS screw bolt 05 to 10mm dia, length of bolt not exceeding 50mm long machine made with hexagonal or square head at one end and screwed the other or serewed both ends, each screwed end fitted with washer and one hexagonal or square nut complete all as specified and directed by Engineer-in-Charge. |
| 24 | M & L for PCC (1:3:6) typeC-2 using 40mm graded stone aggregate as in foundation for post & struts & mass concrete including necessary form work and fair finishing complete all as specified and directed by Engineer-in-charge. |
| 25 | Fixing only mild steel galvanized chain link fencing any mesh, size and type to any type of standards, rails, straining bolts etc. including provision of binding wire complete all as specified and directed by Engineer-in-charge.Note :- Supply only chain link fencing shall be measured and paid for separately under respective item of BOQ. |
| 26 | Supply only mild steel galvanized chain link fencing of any mesh, size and type complete all as specified and directed by Engineer-in-charge.Note:- (i) Flat iron, round bars, nut bolts and washer shall be measured and paid for separately. (ii)The payment shall be made to the contractor for actual weight ascertain by the BOO as odered by GE. |
| 27 | M&L for mild steel work as in posts and struts in fencing including drilling bolting or riveting etc. wind tie for roof including cutting topes to shape as directed, drilling holes, notching for wire etc, flat iron (for securing wire mesh) conforming to Fe-290 Gde E-165, complete all as specified and directed by Engineer-in-Charge. |
| 28 | S&F mild steel round bars 10mm dia, cut to length, bent to shape as in tie bar fixed to chain link fencing including necessary welding where required as per site requirement & other similar works conforming to Fe-290 (Gde E-165) complete all as specified and directed by Engineer-in-charge. |
| 29 | S&F in repair galvanized 2 strand, steel barbed wire 2.24mm dia, barbed with 2mm dia barbs at 75mm spacing and straining and fixing to any type of standard rails, straining bolts, including securing or tying at crossing with and provision of galvanized mild steel wire, staples or steel pins etc complete all as specified and directed by Engineer-in-charge.Note :- Each line of horizontal / vertical / diagonal wire to be measured for the purpose of payment. |
| 30 | Taking down mild steel gate of size area exc 10 sqm but not exc 30 sqm each, straightening, bent up steel sheet and refixing the same in the same opening by grouting pintel hinges in PCC 1:2:4, greasing etc complete all as specified and directed by Engineer-in-charge.Note : Necessary mild steel angle iron work, mild steel plates work, pintel hinges etc if required shall be measured and paid seperately under resepective item of BOQ. |
| 31 | S&F mild steel framed work such as grills, gratings, etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, cooler stand 12mm sq guard bar, framework of water tanks and similar works of quality Fe 290 (Gde E-165) etc complete all as specified and directed by Engineer-in-charge. |
| 32 | M&L for preparation of old painted concrete surfaces of any description, not otherwise described ,over 10 cm width or girth and painting one coat with synthetic enamel complete all as specified and directed. |
| 33 | S&F PVC (SWR) 110 mm bore pipes single socketed in any length with rubber ring joints fixed to wall complete including taking down old unserviceable PVC pipe with fittings complete all as specified and directed. |
| 34 | M&L preparation new or previously untreated steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over and including one coat of red oxide zinc chrome primer complete all as specified and directed by Engineer-in-Charge. |
| 35 | M&L for preparation of old steel surfaces of any description or girth over 10 cm width or girth and applying one coat of synthetic enamel paint, complete all as specified and directed. |
| 36 | M&L for complete removal of existing treatment and preparation of old surfaces of walls and applying two coats of cement based paint on walls etc complete all as specified and as directed. |
| 37 | M&L 75 mm thick Cement concrete type D-2, (1:4:8) using 40 mm graded stone aggregate as in sub base complete all as specified and directed. |
| 38 | M&L for sand filling under floors or in foundation complete all as specified and directed. |
| 39 | M&L for Machine pressed precast conctete interlocking paver block with grey cement & pigment any shape and size conforming to IS 15658-2006 of 60 mm thickness, M-35 Grade complete all as specified and directed. |
| 40 | M&L for Machine pressed precast conctete interlocking paver block with grey cement & pigment any shape and size conforming to IS 15658-2006 of 80 mm thickness, M-40 Grade complete all as specified and directed. |
| 41 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar (1:3) including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5mm), including making drainage opening wherever required complete all as specified and directed. |
| 42 | M&L for pre-polished chequered tiles (any colour) of size 30cm x 30cm x 25mm thick, with gray cement & pigment set, jointed and pointed in neat cement slurry in floors laid over and including 20mm screed bedding in cement mortar (1:4) complete all as specified and directed. |
| 43 | M&L for vitrified paving tiles (any colour) of size 30cm x 30cm x 10mm thick, with gray cement & pigment set, jointed and pointed in neat cement slurry in floors laid over and including 15mm screed bedding in cement mortar (1:4) complete all as specified and directed. |
| 44 | S&F green PVC fibre sheet of 2mm thick fixed with coach screw and washer in roof/ wall complete all as specified and directed. |
| 45 | M&L for preparartion of new plastered surfaces of walls and applying two coats cement base paint on walls complete all as specified and directed. |
| 46 | M&L for preparation of new plastered and unplastered surfaces of wall and applying two coats of exterior Acrylic emulsion paint dark shed over and including one coat of primer as per manufacturer instruction complete all as specified & directed by Engineer-in-Charge. |
| 47 | M&L for preparation of old painted surface of any discpription and applying one coat of exterior emulsion paint of Dark Shade, complete all as specified and directed. |
| 48 | M&L for cement concrete 1:2:4, type B-1 (using 20mm graded stone aggregate) as in lintels upto 1.5 metre clear span, cills, steps, siesmic and other similar bands, plinth courses, string courses, lacing courses, coping, parapets and railing upto 60cm height, copings bed block,roof kerbs or mud stops, kerb stone, kneelers, apex stones, bed plates, surface channels and drains, benching, water troughs and the like including weathering, slightly rounded or chamfered angles and throatings etc.including necessary form work complete all as specified and directed by Engineer-in-Charge. |
| 49 | M&L for cement concrete (1:3:6) type C1 using 20 mm graded crushed stone aggregate as in surface channels and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified and directed by Engineer-in-charge.Note : Forming fair finished channel for drain using extra cement shall be measured and paid for separately. |
| 50 | Extra for forming fair finished drain or channel 45 cm inner girth in cement concrete, using extra cement including forms, moulds, mitred/stopped ends etc. complete all as specified and directed by Engineer-in-charge. |
| 51 | Raking out cement joints to brick work in walls or bricks on edge in floors, surfaces channels, roofs etc. complete all as specified and directed. |
| 52 | M&L for keyed pointing in cement mortar 1:3 to brick wall complete all as specified and directed. Please Enable Macros to View BoQ information |