| 1 | Taking down U/S aluminium/copper point wiring (light, fan, socket or power ) complete including fittings and fixtures such as switches, ceiling roses, pendants, regulators, sockets, light fittings etc removing materials for taking credit (credit for above items should be made as per conditions seperately) and making good the disturbed complete all as specified and directed. |
| 2 | Taking down U/S submain wiring Aluminium/ copper of any size/core/type including earth continuity condutor on teak wood or conduit and removing the materialss/debris from site and making good the disturbed surfaces of wall etc to match with the original existing finish all as directed. |
| 3 | Taking down unserviceable existing TPN DB/ DB SPN 8/10/12 way Mccb DB of any capacity and size and removing from site and making good the disturbed surface of wall etc complete all as specified and as directed. |
| 4 | M/L Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 1.5 sqmm PVC unsheathed copper conductor as earth conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches,sockets etc concealed on wall complete all as specified and directed. |
| 5 | One light point controlled by one switch |
| 6 | One fan/ exhaust fan point controlled by one switch and regulator |
| 7 | One 3 pin socket, 5 Amps on the same board, with cables 1.5 sq. mm size |
| 8 | One 3 pin socket outlet, 5 Amps, independent, with cables 1.5 sq. mm size |
| 9 | One light point controlled by two 2-way switches, with cables 1.5 sqmm. |
| 10 | One call bell controlled by one push button on the same board with other switches or independent with cables 1.5 sqmm |
| 11 | M/L Point wiring complete with 1100volt grade PVC insulated unsheathed multistranded 2.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC casing and capping medium grade of size 25/20 mm, etc fixed on wall/ceiling including provision of 2.5 sqmm PVC unsheathed copper conductor as earth conductor and connected to earth dolly, including provision of pressed steel terminal box with 3mm thick plastic laminated sheet top cover for housing switches,sockets etc concealed on wall complete all as specified and directed. |
| 12 | S&F in repair Switch piano, flush type single pole, one way 5/6 Amp |
| 13 | S&F in repair switch piano SP two way 5/6A 230 V complete all as specified and directed by Engineer in charge. |
| 14 | Supply and fix in repair Socket outlet 2 in 1, 3 pin, 5/6A single pole ,230 V complete all as specified and directed by Engineer in charge. |
| 15 | S&F in repair Switch socket combination 2 in 1, 5A 3 Pin and 5A 2 pin combined flush type, 230 V ,complete all as specified and directed by Engineer in charge. |
| 16 | S&F in repair switch piano flush button type single pole 15/16 Amps. 230 V complete all as specified and directed by Engineer in charge. |
| 17 | Supply and fix in repair socket outlet flush type 2 in 1, 3 pin 5 and 15/16 Amp single pole ,230 V complete all as specified and directed by Engineer in charge. |
| 18 | S&F in repair Switch socket combination 5 in 1, 5A /15A combined flush type, 230 V ,complete all as specified and directed by Engineer in charge. |
| 19 | S&F in repair Bell push piano 5 Amp, 230 volts, 50 HZ ,AC all as specified and directed. |
| 20 | S/F in repair deluxe stepped type electronic fan regulator flush type on the phenolic laminated sheet complete all as specified and as directed, Make:- Anchor/Havells/Legrand/Scheinder |
| 21 | Supply and fix in repair hylam sheets 3mm thick including cutting for mounting of switches / sockets suitable for sunken box of any sizes upto 12''x10'' as per existing site. :- Make :-As per sample. |
| 22 | Supply and fix in repair pressed steel sunk box 3mm thick including cutting of walls removing old box and making the surface good matching the existing, size upto 12\\"x0\\", as per existing site. Make :-As per sample. |
| 23 | S&F in repair switch piano modular type single pole 5/6 Amps one way all as specified and directed. Make: As per site |
| 24 | S&F in repair modular switch socket combination 3 pin, 5/6 Amps universal all as specified and directed. Make: As per site |
| 25 | S&F in repair modular switch socket outlet multipurpose 3 pin,16 Amps and 2 pin 5/6 Amp controlled by one swtich 3 module all as specified and directed. Make: As per site |
| 26 | S&F in repair Bell push 6 Amp, flush type, modular 230 volts, 50 HZ ,AC supply 01 module all as specified and directed. Make: as per site |
| 27 | S&F in repair modular stepped type electronic fan regulator 2 Modular 120 W complete all as specified and as directed, Make: As per site |
| 28 | S & F in repairs white modular cover plate with frame upto 12 module all as specified and directed. |
| 29 | S & F in repair modular metal flush box upto12 module all as specified and directed. |
| 30 | S&F in repair Ding dong Bell, AC, 230 volts, single pole 50 HZ AC supplyall as specified and directed. |
| 31 | S&F in repair ceiling rose three terminal 230 volt 50 HZ AC, with back plate supply all as specified and directed. |
| 32 | S & F in repairs LED batten tube light fitting type 1x 20 watt indoor type complete including all accesories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed |
| 33 | S & F in repairs Integrated LED batten tube light fitting type 1x 18 watt indoor type complete with all accesories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed |
| 34 | S & F in repairs LED light fitting mirror type with high out put diffuser 2 feet , 10 watt 220 v AC including with all accesories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed |
| 35 | Supply and fix in repair LED bulb of 9 Watt. |
| 36 | Supply and fixing in repair LED luminaire 600 mm x 600 mm, 36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete |
| 37 | Supply and fix in repair MCB DB,Double door single pole and neutral with suitable rated busbar double door, 8 way 230 volt 50 HZ AC Supply complete all as specified and directed. |
| 38 | S&F in repair MCB SP 06 to 32 Amp 230 volts,50Hz,Breaking Capacity 10 KA Matching to the existing location complete all as specified and directed |
| 39 | Supply and fixing in repair 32 AMP rating 240V, 10KA 'C' curve miniature circuit breaker (MCB) SPN and current carrying capacity in the MCB DB complete with connection testing and commissioning |
| 40 | Supply and fix in repair MCB DB, TPN with suitable rated busbar double door, 4 way 415 volt 50 HZ AC Supply complete all as specified and directed. |
| 41 | Supply and fixing in repair Isolator TPN 63 Amps 415 volts complete all as specified and directed by Engineer-in-Charge |
| 42 | Supply and fix in repair MCCB 4 Pole 63 Amp with breaking capacity 16 KA, 415 volt 50 HZ AC supply complete all as specified and directed. |
| 43 | Supply and fix in repair MCCB 4 Pole 250 Amp with breaking capacity 36 KA, 415 volt 50 HZ AC supply complete all as specified and directed. |
| 44 | M & L for submain wiring complete with 1100volt grade PVC insulated unsheathed multistranded cable with 1100volt grade PVC insulated unsheathed multistranded 02 run of 1.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC Casing & caping in Ivory/Grey/white/Black colour medium grade etc fixed on wall/ceiling including provision of 01 run of 1.5 sqmm PVC unsheathed copper conductor and Connected to earth dolly complete all as specified and as directed. Note :- 02 run of 1.5 sqmm and 01 run of 1.5 sqm including 01 run of PVC Casing & caping will be measured as one length.complete all as specified and directed. |
| 45 | M & L for submain wiring complete with 1100volt grade PVC insulated unsheathed multistranded cable with 1100volt grade PVC insulated unsheathed multistranded 02 run of 2.5 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC Casing & caping in Ivory/Grey/white/Black colour medium grade etc fixed on wall/ceiling including provision of 01 run of 2.5 sqmm PVC unsheathed copper conductor and Connected to earth dolly complete all as specified and as directed. Note :- 02 run of 2.5 sqmm and 01 run of 2.5 sqm including 01 run of PVC Casing & caping will be measured as one length.complete all as specified and directed. |
| 46 | M & L for submain wiring complete with 1100volt grade PVC insulated unsheathed multistranded cable with 1100volt grade PVC insulated unsheathed multistranded 02 run of 04 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC Casing & caping/ concealed conduit (as per requirement and direction of Eng-in-charge) in Ivory/Grey/white/Black colour medium grade etc fixed on wall/ceiling including provision of 01 run of 4 sqmm PVC unsheathed copper conductor and Connected to earth dolly complete all as specified and as directed. Note :- 02 run of 04 sqmm and 01 run of 4 sqm including 01 run of PVC Casing & caping will be measured as one length.complete all as specified and directed. |
| 47 | M & L for submain wiring complete with 1100volt grade PVC insulated unsheathed multistranded cable with 1100volt grade PVC insulated unsheathed multistranded 02 run of 06 sqmm copper conductor cable confirming to IS 694 FRLS drawn through and including rigid PVC Casing & caping in Ivory/Grey/white/Black colour medium grade etc fixed on wall/ceiling including provision of 01 run of 6.0 sqmm PVC unsheathed copper conductor and Connected to earth dolly complete all as specified and as directed. Note :- 02 run of 06 sqmm and 01 run of 6.0 sqm including 01 run of PVC Casing & caping will be measured as one length.complete all as specified and directed. |
| 48 | S & F in repairs PVC Casing & Caping double lock type of as required width (not less than 20/25 mm in width) ISI marked medium grade white colour with all accessories of same grade fixed on wall/ceiling etc. complete all as specified and as directed. (Rate inclusive of taking down old casing caping and fixing existing wiring in new casing caping) |
| 49 | M & L for Earthing complete with Galvanised earth plate electrode 600 x 600 x 6 mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5 mtr below normal ground level connected to galvanised earth wire 4 mm dia by mean of nuts/bolts, check nuts and washers of brass as shown in electrical plate No. 3 of SSR part-I including necessary excavation and earth work, GI Pipe 15 mm bore light grade for watering with Funnel, wire mesh and protection to earth lead shall be provided with GI pipe light grade 15 mm dia up to 7.5 mtr from the earth plate electrode and refilling of soil including adequate quantity of charcoal dust and common salt etc & earth work in any strata, PCC pit chamber in cement mortar 1:3:6 type C-2 with 40 mm thick Precast RCC cover slab 1:2:4 type B with 8 mm dia TMT bar and handle with lifting hooks including testing any type complete all as specified and directed by Engineer-in-Charge including demolish existing earth pit taking out old materials. |
| 50 | Note:- If the desire earth resistance is not obtained the earthing will be redone at no extra cost |
| 51 | M & L for Earthing complete with GI earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) filled with common salt and charcoal and connected to GI earth strip 25 x 4 mm thick by means of GI nuts, bolts, & washers as shown in electrical plate No. 3 of SSR Part-I and Connected to earthing test point all as specified and including necessary PCC earth pit chamber of 1:3:6 and chamber cover of 50mm thick PCC 1:2:4 with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe light grade of 20mm dia including funnel and protection to earth lead shall be provided with GI pipe light grade 40 mm dia unto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC work complete all as specified and directed by Engr-in-charge including demolish existing earth pit taking out old materials.Note:If the desire earth resistance is not obtained the earthing will be redone at no extra cost |
| 52 | Supply and fixing in repairs Earth continuity conductor or main earthing lead of GI earth strip 25 x 4 mm thick by means of nuts, bolts & washers fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required, All as per directed by Eng-in-Charge. Note: Rate inclusive of necessary welding,nut,boults, Washers & Clamp for connections |
| 53 | Checking and attending electrical complaints such as loose connection,hanging tubelights, short circuit, burnt terminal or no supply, including replacement of damaged wire up to 1.5 meters and minor consumables like screws, nuts, bolts, and cable ties, complete as required and directed by the Engineer-in-Charge. Note: rate inclusive of small items like screws, nuts, bolts, and cable ties, wire up to 1.5 meters, etcNote: Contractor should note before quoting that All items from 1 to 46 may be executed at different locations against daily complaints by user in any number of quantity as per direction of Eng-in-charge. Please Enable Macros to View BoQ information |