| 1 | Demolition of brickwork or stone/boulder masonry built in cement mortar including all quoins, arches, pillars etc., but excluding ashlar facing, dressed stone work and precast concrete articles, including dismantling/segrgating serviceable bricks and stacked properly for re-use ,complete all as specified & directed by GE. |
| 2 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for. |
| 3 | Taking down cement plaster/wall tiles including backing etc from brick/stone walls / concrete surfaces including raking out joints, hacking for key , scrubbing down with water etc complete all as specified and directed by GE. |
| 4 | M & L for Brick work with old size bricks straight or curved on plan exceeding 6 m mean radius with old size bricks built in cement mortar 1 : 4 complete all as specified and directed by GE. |
| 5 | M & L for Brickwork with sub-class ‘B’ bricks (old size), straight or curved on plan exc. 6m in mean radius, built in cement mortar 1:4 but except brick i.e. using serviceable bricks obtained from Srl item No. 5 here-in-before, complete all as specified & directed by GE. |
| 6 | Extra for forming fair finished drain or drain channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred stopped ends etc complete all as specified and directed by GE. |
| 7 | M&L Rendering 15 mm thick on fair face of brick work or concrete surface in CM 1:4, finished even and smooth without using extra cement. |
| 8 | M&L for angle section fixed independently w/o connecting plate as in swan neck fencing of Fe-410-w(gde E-250A all as specified & directed by GE. |
| 9 | M&L for framed work such as grills, gratings etc with end of bars shouldered or riveted or forged into spikes, framed guard bars confirming to Fe-290, Gde-E-165. |
| 10 | M&L PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregate as in coping or fixing of angle iron horn, bed plates benching etc slightly rounded or chamferred angles and throating including necessary form work, complte all as specified and directed by GE. |
| 11 | Dismantling of galvanised barbed wire /concentria coil of any description or in any position complete and removing from site all as specified and as directed by GE. |
| 12 | Dismantling cast iron work of any descriptions all as specified & directed by GE. |
| 13 | S&F Galvanised 2 strand steel barbed wire 2.24mm dia, barbed with 2.00 mm dia barbs at 75mm spacing, straining and fixing to any standard rails and straining bolts incl securing or typing at crossing with and provisions of galvanised mild steel wire stapples or steel pins etc all as specified and directed by GE. |
| 14 | M & L for Barbed razor tape concertina coil SG hot galvanised spring tensile wire as approved by GE, dia of coil when stretched 450mm having minimum number of circles 10 Per RM, minimum number of clips 15/RM, complete all as specified & directed by GE. |
| 15 | M&L for preparation of new or previously untreated steel or iron surfaces of any description, over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red-oxide primer. |
| 16 | M&L for preparing of Old painted surfaces of steel or iron surfaces of any description, over 10 cm width or girth and applying one coat of synthetic enamel paint. |
| 17 | M & L for preparation of new plaster surface and applying two coats of weather proof exterior emulsion paint of anti fungal nature on walls complete all as specified and directed by GE.Note : The work will be carried out upto tripple storey builing the rate of scafolding is included for this item also. |
| 18 | M&L for preparation of newly plastered surfaces or concrete surfaces of wall and applying two coat of cement based paint over a coat of primer. |
| 19 | Supply only integral water proofing compound all as specified & directed by GE. |
| 20 | Excavating in post holes (or similar holes) in soft/loose soil each n exc 0.5 cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface or any type of soils. |
| 21 | M&L PCC 1:3:6 type B-2 using 40mm graded stone aggregate as in columns, pillars, boundary pillars and posts (including caps and bases) complete, all as specified and directed by GE. |
| 22 | S&F ISA 65 X 65X 8 mm as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., conforming to Fe 410-0 or Fe 310-0 complete all as specified & directed by GE. |
| 23 | S&F, Mild steel screw bolts 12mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, length of bolt n exc 10cm dia of shank 16 to 20 mm complete all as specified & directed by GE. |
| 24 | Dismantling fencing wire mesh any type complete all as specified & directed by GE. |
| 25 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire |
| 26 | Supply only Chain link MS galvanised mild steel of mesh 100 x100mm size ,10 gauge complete all as specified and directed by GE. |
| 27 | M&L for 75 mm thick cement concrete type C-2, 1:3:6 (40mm graded agg) as in Sub-base to floor finishes complete all as specified & directed by GE. |
| 28 | M&L 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour design and pattern as in footpart, park lawns , drive ways or light traffic parking etc, of required strength , thickness and size/shape made by table vitratory method using PU mould, laid in required colour and pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibrator compaction by using plater vibrator compaction by using plater vibrator , filling the joints with sand and cutting paver blocks as per required size and pattern , finishing and sweeping and sweeping sand. |
| 29 | M & L for Factory made precast designer paver tiles (Dura Stone) of different colour and shape of size 300x300x20mm laid and jointed with grey cement slurry with pigment to match the colour of tile, . compressive strength not less than 250 kg/Sqm including 15mm thick screed bed in cement mortar 1:4, complete all as specified & directed complete all as specified and directed by GE. |
| 30 | M & L for 100mm thick PCC 1:4:8, nominal mix, type D2, using 40mm graded crushed stone aggregate as in pavement, hard standing, path etc, surface finished even and fair, laid in alternate bays including form work,without using extra cement, complete all as specified & directed by GE. |
| 31 | M & L for Complete removal of existing treatment of wall surfaces and applying two coats of cement based paint complete all as specified & directed by GE. Please Enable Macros to View BoQ information |