| 1 | Safe carriage of following material from store center PVVNL to site of work with loading and unloading at both ends. |
| 2 | 13 Mtr./11 Mtr./9 Mtr./8.5 Mtr Long PCC Pole. |
| 3 | 11/0.4 KV T/F 25/63/100 KVA |
| 4 | 11/0.4 KV T/F 250 KVA |
| 5 | ACSR Weasel Conductor. |
| 6 | LT ABC Cable (3x120+1x95+1x16), (3x95+1x50+1x16) and (3x50+1x35+1x16) Sq.mm |
| 7 | L.T. XLPE cable of size (1x120),(1x240) and (1x400)sqmm and LT PVC Cable Size 3.5x150/70mm |
| 8 | 11 KV Disc Insulator with fitting/11 KV Pin insulator. |
| 9 | 11 KV fuse Set/D.O. Fuse set/11 KV TPMO |
| 10 | Earthing set complete/Stay Rod set Complete. |
| 11 | 3 Phase Distribution Box. |
| 12 | Erection/Fixing & laying/Installation of following materials as per RESPO manual and as per direction to Supervising Engineer (complete in all respect). Work includes the cost of labour, T&P by providing nut, bolt, Stone pad, G.I. Pipe 6\\" dia and all other acessaries/material for proper completion of work. |
| 13 | For 11 KV Line, Double Pole structure with 13/11/9/8.5 Mtr. long PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole). Erection of support (pole) complete work by fixing of D.P. Clamps and all other accessories. The work includes fabrication work and fixing of cross bracing sets, cutting holes complete work as per RESPO Norms. |
| 14 | For LT/11 KV Line, Single Pole structure with 13/11/9/8.5 Mtr. long PCC Poles :- Excavation of foundation pit in size of 75x45 cm. having depth of 1/6th of the full length of the support (pole). Erection of support (pole) complete work by fixing of all other accessories. The work includes fabrication work and fixing of cross bracing sets, cutting holes complete work as per RESPO Norms. |
| 15 | Grouting of Poles Single line support :- Grouting of support in CC 1:4:6 (cement, sand and 40 mm. brick ballast) Grouting will be done in the block of size 45cm x 45cm x 1/6th of full length of the support upto ground level as per RESPO Norms. |
| 16 | Fixing and Grouting of stay rods (20x1800mm.) including all works of excavation, cement concrete in size of (0.60x0.60x0.30)M in the ratio of 1:4:6 (cement, sand and 40 mm. brick ballast) including back filling of soil and proper ramming etc.Fixing, tightening and nozelling of stay wire with stay rod and stay insulators with the pole of required tension by providing stay clamps, nuts, bolts etc. |
| 17 | Earthing of support with MS Earth Rod of (20x2500)mm. long including excavation of pit and driving MS Rod 3.0M apart from support and 0.5M below the ground level and connecting below the earth electrodes with the help of G.I. Wire No.6 SWG tightening with nuts and bolts. |
| 18 | Mounting and fixing of 25/63/100 KVA transformer on double pole including making proper connections and earthing by MS eathing rod. |
| 19 | Construction of plinth for 250 KVA Transformer of size 5’x5’x4’ above the ground lable and 1 feet below the ground. At the bottom there shall be CC pad of brick ballast of size 5x5’x3” thick in ratio 1:3:6 [Cement, sand and brick ballast]. The first class brick wall work shall be 9” thick in ratio 1:4 [Cement and sand]. The hollow portion among the wall shall be filled up with the brick ballast. On the top of the wall of plint there shall be RCC work in ratio 1:3:6 [Cement, Sand and grit stone] by using 12 mm dai MS bar at distance of 9’’. There shall be plastering all over the plinth 12 mm thick in ratio 1:4 [Cement and sand] above the ground level. Proper watering and curing of the plinth shall be carried out as per direction of supervising engineer. |
| 20 | Fencing of 250 KVA T/Fs as Fabrication of 50x50x6 mm size MS Angle frame of size 3000x2400mm with 450 mm long angle for grouting the frame and fixing of 2\\"x1.5\\", 10 SWG welded wire mesh with MS strip of 24x5mm size all round the frame and drilling 9 mm holes insides of frames at as distance of 300mm for jointing of frame with the help of boslts and nuts including cost of material. The width of panal may vary as per site conditions Grouting and fixing of angle iron frames in ratio 1:2:4 (cement, coarse sand and stone ballast ) in the pocket of 150x150x150mm all round the plinth and bolting of frames with 25x8 mm size bolts and nuts. Making main gate in front of the plinth of size 3000x2400 mm by making two leaves of size 3000x1200mm size and grouting the same in ratio and method mentioned at item (b) above fixing with hinges with dandlas for locking system. Painting of entire wire mesh angle iron etc. with Bus Green super enamelled pain in two coats on the primer two coats of Red oxide. |
| 21 | Installation of 250 KVA T/F on newly constructed plinth in proper alignment and direction & making HT/LT connection. providing \\"L\\" type alminium bus bar and suitable size alminium lugs |
| 22 | Water Level earthing of 250 kva(Neutral and body) T/F. Water level earthing work minimum 60 feet or upto water level whichever in higher. Complete work by providing G.I. Strip G.I pipe and all other materials, labour and T&P. |
| 23 | Chemical earthing of distribution T/F 250 kva by digging boring by inserting earth electrode and chemical. It's connecting by G.I strip from earth electrode to body of T/F and neutral including |
| 24 | Fixing of 11 KV fuse set. |
| 25 | Fixing of Distribution Box 3 Phase making all consumer cable connection. |
| 26 | Laying, sagging, stringing and binding of ACSR/Dog/Rabbit/weasel conductor with all other accessories on pole as per respo norms. |
| 27 | Laying, sagging, stringing and binding of ABC cable of size (3x120+1x95+1x16), (3x95+1x50+1x16) and (3x50+1x35+1x16) with all other accessories on pole as per respo norms. |
| 28 | Laying of LT XLPE cable of size (1x120) and (1x400)sqmm and LT PVC Cable Size 3.5x150/70mm with making connections as per norms. |
| 29 | Providing and fixing of Al. lugs for 25 Kva T/F. |
| 30 | Providing and fixing of Al. lugs for 250 Kva T/F. |
| 31 | Providing and fixing copper L-Piece 50x225x10mm. |
| 32 | Providing and fixing of L.T. clamp with Nut and bolt, I and J Hook, Dead and clamp, Distribution clamp. |
| 33 | Providing and fixing of Stonepad of size 300x300x75 |
| 34 | Providing and fixing Barbered wire. |
| 35 | Provide and fitting of MS Dropper Channel/Top Channel |
| 36 | Provide and fitting of MS T-off channel/MS angle |
| 37 | Providing and fixing of Number Plate and Danger Board with Nut and Bolts. |
| 38 | Providing and fixing of LT fuse set protection unit for 25/63/100 KVA T/F with SMC BOX by providing all type material as per respo norms. |
| 39 | Providing and fixing of Tailless unit for 250 KVA T/F by providing all type material as per respo norms. |
| 40 | Safe carriage of following material from site to PVVNL store centre work with loading and unloading at both ends. |
| 41 | 10 KVA Transformer. |
| 42 | 16 KVA Transformer. |
| 43 | 100 KVA Transformer. |
| 44 | 160 KVA Transformer. Please Enable Macros to View BoQ information |