| 1 | Providing and fixing partition up to ceiling height consisting of G.I. frame and required board, including providing and fixing of frame work made of special section power pressed/ roll form G.I. sheet with zinc coating of 120 gms/ sqm (both side inclusive), consisting of floor and ceiling channel 50mm wide having equal flanges of 32 mm and 0.50 mm thick, fixed to the floor and ceiling at the spacing of 610 mm centre to centre with dash fastener of 12.5 mm dia meter 50 mm length or suitable anchor fastener or metal screws with nylon plugs and the studs 48 mm wide having one flange of 34 mm and other flange 36 mm and 0.50 mm thick fixed vertically within flanges of floor and ceiling channel and placed at a spacing of 610 mm centre to centre by 6 mm dia bolts and nuts, including fixing of studs along both ends of partition fixed flush to wall with suitable anchor fastener or metal screws with nylon plugs at spacing of 450 mm centre to centre, and fixing of boards to both side of frame work by 25 mm long dry wall screws on studs, floor and ceiling channels at the spacing of 300 mm centre to centre. The boards are to be fixed to the frame work with joints staggered to avoid through cracks, Galvanised M.S. fixing channel of 99 mm width (0.9 mm thick having two flanges of 9.5 mm each with zinc coating of 120 gms/sqm(both side inclusive)) to be provided at the horizontal joints of two boards, fixed to the studs using metal to metal flat head screws, including jointing and finishing to a flush finish with recommended jointing compound, jointing tape, angle beads at corners (25 mm x 25 mm x 0.5 mm), joint finisher and two coats of primer suitable for board as per manufacture's specification and direction of engineer in charge all complete |
| 2 | 75 mm overall thickness partition with 12.5 mm thick double skin fire rated Glass Reinforced Gypsum (GRG) plaster board conforming to IS: 2095: (part 3) : 1996 (Board with BIS certification marks).Including 50mm, (48 kg/cum) thick glass wool insulation of Owen Cronies or UP Twiga make, glasswool to be wrapped with RP tissue, binding & bracing. From raw floor to the bottom of ceiling (Rate to be including plastic emulsion paint till the bottom of false ceiling) Cement Board Partition also included. (Frame of full height partition must be able to sustain the load of cement board also) |
| 3 | Providing and laying Brick work with common burnt clay F.P.S (non Modular) bricks of class designation 7.5 in foundation & plinth |
| 4 | x) Half brick masonry with common burnt clay F.P.S.(non modular) brick of class designation 7.5 in Cement mortar 1:4 (1 cement:4 coarse sand in superstructure ABOVE PLINTH level & UP TO FLOOR V LEVEL |
| 5 | Providing and laying cement plaster on surfaces with fine sand including curing etc. |
| 6 | i) 12 mm cement plaster of mix 1:4 (1 cement: 4 fine sand) |
| 7 | iii) 15mm Cement plaster of mix 1:4 (1 cement: 4 fine sand) on rough side of half or single brick wall |
| 8 | Workstations cabinet T33Providing and placing modular storage cabinet made up of of 19 mm thk. B.W.P plywood with counter Top made of 2 X 19 mm B.W.P plywood with 1mm laminate on outer side and 0.72 mm laminate in the inner side including all Sides Edge Banding / steem beach (as decided by EIC) including all the necessary accessories and 100 mm skirting . Complete in all respect.(Please Note mode of measurement of said furniture will be according to LXH of the cabinet ) |
| 9 | 2500x600x900mm (Please Note mode of measurement of said furniture will be according to LXH of the cabinet) |
| 10 | Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length |
| 11 | ii) Sal wood |
| 12 | Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length |
| 13 | i) 35mm thick including ISI marked Stainless Steel butt hinges with necessary screws. |
| 14 | Providing & fixing chromium plated brass night latch including necessary screws etc. complete (Best make of approved quality). |
| 15 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixed with rawl plugs and screws or with fixing clips, or with expansion hold fasteners including necessary filling up of gaps at junctions,at top, bottom & sides with with required EPDM rubber/neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/panelling, C.P. brass/stainless steel screws including fixing all complete as per drawing & the directions of Engineer-in-charge. (Cost of glazing or panels to be paid for separately) |
| 16 | iii) For shutters of doors, windows & ventilators with Powder coated aluminium sections including providing fixing hinges/ pivots & making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 17 | Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge. (Cost of aluminium snap beading shall be paid in basic item): |
| 18 | iii) With float glass panes of 8.0 mm thickness (weight not less than 20kg/sqm) |
| 19 | Providing & fixing aluminium handles ISI marked anodised (anodic coating not less than grade AC10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete : |
| 20 | i) 125 mm |
| 21 | Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade with 2 or more coats |
| 22 | Providing and applying plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete |
| 23 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface : |
| 24 | Supply and Fixing of Discrete LED (Light Emitting Diode) Tube lights of 18 Watt, having IP65 protection class with Pressure Die Cast Aluminium housing & with Polycarbonate diffuser of approved make or equivalent as per direction of Engineer in charge. The LED shall be operating under voltage range of 140-270V with power factor more than 0.9. CCT(Correlated Colour temperature) shall be 5700 Kelvin (5665 K +/- 355 K), CRI (Colour rendering index) not less than 65. LED efficacy should be minimum 100 lumens/watt. The driver shall be of constant volt & constant current type with internal surge protection. Each lot of Fittings shall have serial numbers and accompany LM79 / IS 16106 test reports and reference/batch nos of LEDs and fittings for verification at site. The supply of LED lighting shall be covered by a warranty of at least 72 months from the date of supply of the lighting and the LED light fitting shall be complete in all respects including LED, LED Driver, Electronic circuitory, Luminarie etc. |
| 25 | CABLING AND ALLIED WORKS - ARMOURED CABLES Supply & laying of XLPE insulated PVC sheathed aluminium/copper conductor, 1.1 kV grade armoured cable conforming to IS:7098, as per approved make in ground/ trench/surface/pipe, etc. whereever required as per direction of Engineer In-charge. Note: The rate of Installation should be inclusive of Cable clamps, tags Saddles, Consumables etc. Trays/pipes, trenches, fabricated tray supports etc will be covered & paid in Separate Items |
| 26 | iv) 3 Core x 2.5 sq. mm Copper Cable FRLS |
| 27 | Godrej Make File Compactor for Room Size 2.6X3.9 m (Drive Type Optimizer)- Overall Dimensions of TD2 Twin Drive Unit 4 bay(U/C + Fittings + Cover) shall be 2400mm(W)x800mm(D)x2047mm(H). The Construction shall be rigid knock down made out of 0.8 thick CRCA steel conforming to IS : 513 . Each body shall have a main unit plus add on units (1,2,3,4,5) . Finish shall be Epoxy polyester powder coated thickness of 40 microns . Shelf construction shall be made from CRCA steel 0.8 mm thick IS :513 .Uniformly distributed load capacity of 100 Kg . Undercarriage shall have construction in welded frame made of HR sheet 3 mm thick conforming to IS : 3062. The Movements shall be Drive Type configuration : In case of D2,D3 & D4 movement of units is achieved mechanically through a PU Drive Wheel and Sprocket -Chain-Tensioner arrangement mounted rigidly onto body size. For D4 each movable undercarriage shall be provided with 4 rollers on the shaft for driving ,4 antifriction ball bearing for rolling. The roller assembly comprises of a die-cast step wheel, 2 deep-groove ball bearings and a MS shaft. The step wheel is made of cast steel and is fitted onto the MS shaft using a feather key. The two ball bearings are then fastened on either side of the step wheel using circlips. This entire roller assembly is then snap-fitted into a wheel housing. The wheel housing is fixed in the Uchannel of the understructure using machine screws. This wheel-housing is made of engineering plastic material made by injection-molding process. The entire roller assembly is designed to withstand the maximum loads of the body. Fittings shall be centralized locking arrangement through locking stiffener mounted onto back of single last unit so that it gets locked on channels when all the units are brought together. The Recess handle lock is of Godrej make & placed at suitable height .The ‘sprocket-chain’ arrangement is covered by a 1 mm thk. CRCA sheet Drive Unit Cover with dimensions 1302mm x 398mm x 87mm and is fixed onto the side of the body. The PU handwheel is rigidly fixed at suitable height on side of the body & projects out of cover by another 99.0 mm. Fixed unit (SD) does not have the Drive Unit Cover. When the last unit is twin movable, hinged doors as accessories are provided for the end bodies, so in this case locking stiffener is mounted onto drive unit cover; and with tile fascia option, it will be mounted in the recess of vertical trim. Each Drive Type units shall have Locking Knob near the drive wheel for manual locking of individual units when a person is using those units. Knob shall be rotated to unlock position when units are to be moved. End stoppers shall be provided to prevent derailment.The nuts & bolts are galvanized / blackodized / Zn Plated. Also total no. of loading levels per understructure shall be 48 for TD4. Label holder - It is an aluminium extrusion of length 396mm for LD/SD and 796mm for TD, fitted on to front cover of body. The Paper is 300GSM matt milky white sticker paper, to be inserted into the aluminium extrusion. The length of paper is 394mm for LD/SD and 794mm for TD. Over that a transparent plastic of corresponding length of 150-300 micron polythene is to be inserted.TD units are designed with tie rod assembly options as well. it acts as a substitute to the back panels (only in twin body) if the customer chooses to not have back panels. The assembly consists of 2 tie rods, 4 fixing brackets and 2 turnbuckles. The tie rods are fixed in a shape of ‘X’ between two opposite shelves. The tie rods are made of 4mm diameter rods of MS while the fixing brackets are made of 2mm thk. CRCA Steel conforming to IS: 513 Gr.D. This assembly is available for both heights – 1980H and 2361H. |
| 28 | Parts of Drive Type Optimizer. (a) Optz SD2 2400mm 2047mm SW-01 no. (b) Optz LD2 2400mm 2047mm SW -01no. (C ) Optz TD2 2400mm 2047mm SW WOP -02 nos. (d) Optz D2 CHNL 800mm -01 no. (e ) Optz D2 CHNL 2400mm- 01 no Please Enable Macros to View BoQ information |