| 1 | SITC of IP-42 and general construction confirming to IS:8623 : 1993, wall/ free standing floor mounted dust and vermin proof compartmentalised cubical panel as specifications and Other parameters required as per point (a) ,(b), (c),(d), (e), (f), (g), (h) as below:-(a)Thickness of CRCA sheet shall be 2.0 mm, cable alley compartments having concealed hinged type doors with key type lock with / without detachable extension type structure. Removable 3 mm. thick sheet steel gland plates with appropriate size of knockouts for cables shall be provided(b)complete panel shall undergo a process of degreasing, Water rinsing, Activation, derusting, pickling in acid bath, phosphatising & shall be subjected to nine tank process and then Powder coated with approved shade of minimum 70 microns on both side of panel. The panel having PE foam/ Neoprene rubber gasket of not less than 3mm thickness ,required hardware , concealed hinged door with key type locking arrangement for equipment/switchgear earthed with 2.5 sq.mm braided copper wire.[c) Interconnection between bus bar and switchgears /cable shall be rigidly supported and made out by flexible copper wires (up to 63 amp ) and by solid bus bar (>63 amp ) . control wiring will be carried out with 1.5 Sq.mm, Earth wire with 2.5 Sq.mm and CT with 2.5 sq.mm flexible copper wire only. All joints / interconnections of copper bus bar shall be dully tinned . Clearance between main bus bar and risers / metal parts shall be at least 10 mm additional to width of bus bar Bus bar is insulated by Heat Shrinkable sleeves . Earth and Neutral bus bar shall be half of the size of phase bus bar. ( Cost of Bus bar / Flexible wire for Interconnection between Main busbar and Switchgear is to be Paid Extra )(d)Wiring between components within switchgear and Incoming / outgoing cable shall be done through the terminal block only. Direct connection shall not be permitted. Each terminal block shall be one piece moulded, barrier type, 650 volt grade, complete with washers, heads, studs with two nuts and identification strips and shall have adequate continuous current rating. For tap-offs, adjacent terminals with shorting strips shall be used. 10% Spare terminal blocks shall be provided. Wire identification on marking strip shall correspond to the designation of the wiring diagrams. All wire terminals on the equipment shall also be marked with designation corresponding to those of the wiring diagram. (e)All wiring shall be enclosed in plastic channels and neatly bunched and closed in metering chamber, Wiring between terminals of various devices shall be ‘point to point’ (no wire splitting or tee connections) with wires neatly trucked along the back of the panels, adequately supported to prevent sagging.(f)Floor mounted panel shall be mounted on Base frame of ISMC channel size 100 x 50 x 5 mm ( to be paid Extra )(g) Tests: The insulation resistance (with 1000 V Megger) and High voltage Power frequency test (by a |
| 2 | SITC of Decorative Ornamental pole with Single arm bracket. Total height of the pole with Single arm Bracket shall be 8000 mm nominal above the ground. The pole is made out of Combination of grooved and plain mild steel tube with cast aluminium pedestal. in three steps as shown in attached drawing. Casted embellishments are fitted with the help of grub screws. Dia and length of the bottom tubular section is 140mm x 4mm thick and 3000mm respectively which shall pass through the casted pedestal and welded with the baseplate and dia of grooved portion shall be reduced to 133mm. Dia and length of the middle section is 114mm x 3.6mmthick and 2700mm respectively. Dia and length of the top section is 89mm x 3.6mm thick and 1300mm respectively. Height of the pedestal shall be 715mm and dimensions of the base plate shall be 335mmx16mm thick. One Nos of morpankh embellishments made of cast aluminium shall be fitted on the upper section of the pole as shown in the attached drawing. A built in service window is provided to accommodate a 6 amp SP MCB and 32 amp heavy duty LILO connector for mains connections in the bottom part of the pole. The different sections of the pole are joined together by means of Welded joints. The decorative bracket is made out of mild steel, cast aluminium. The mild steel & cast aluminium part are joined together & are fabricated to get the desired design as per attached drawing. The dia of vertical and horizontal section of bracket shall be 76mmx3mm thick and 42mmx2.9mmthick respectively. A morpankh embellishment shall be fixed on the top of the bracket with two Nos of spot light to lit the morpankh embellishment. The decorative bracket should have the arrangement to fix the required luminaire. The bracket should have the arrangement suitable to be fitted on the required pole. The dimensions of the pole and bracket should be as per attached drawing. The Decorative Pole and Single arm bracket Shall be machined and Polished properly to give it a smooth Surface. The Decorative pole with Single arm bracket is duly pretreated by shotblasting process and painted in U.V. ray resistant P.U. coating in approved color shade. The Coating should have a minimum DFT of 90 microns and should pass a minimum of 300 Salt spray hours as per IS or ASTM testing methods. Decorative pole with single arm bracket shall be installed at desired location on existing foundation of the pole by making cement concrete foundation of 1:1.5:3( 1 cement: 1.5 course sand: 3 graded stone aggregate 40mm nominal size) with the help of anchor bolts and 38mm G.I sleeve as required. Weight of decorative pole and decorative single arm should be 165 kg and 5.5 kg respectively. Weight tolerance limit of pole & arm is +/-5%.Make:-Philips/Orient/Ligman/Neri/K-Lite/Pyrotech/Lustre/Surya/Bajaj |
| 3 | SITC of Decorative Ornamental pole with Dual arm bracket. Total height of the pole with Dual arm Bracket shall be 8000 mm nominal above the ground. The pole is made out of Combination of grooved and plain mild steel tube with cast aluminium pedestal. in three steps as shown in attached drawing. Cast Aluminium embellishments are fitted with the help of grub screws. Dia and length of the bottom tubular section is 140mm x 4mm thick and 3000mm respectively which shall pass through the casted pedestal and welded with the baseplate and dia of grooved portion shall be reduced to 133mm. Dia and length of the middle section is 114mm x 3.6mmthick and 2700mm respectively. Dia and length of the top section is 89mm x 3.6mm thick and 1300mm respectively. Height of the pedestal shall be 715mm and dimensions of the base plate shall be 335mmx16mm thick. One Nos of morpankh embellishments made of cast aluminium shall be fitted on the upper section of the pole as shown in the attached drawing. A built in service window is provided to accommodate a 6 amp SP MCB and 32 amp heavy duty LILO connector for mains connections in the bottom part of the pole. The different sections of the pole are joined together by means of Welded joints. The decorative bracket is made out of mild steel, cast aluminium. The mild steel & cast aluminium part are joined together & are fabricated to get the desired design as per attached drawing. The dia of vertical and horizontal section of bracket shall be 76mmx3mm thick and 42mmx2.9mmthick respectively. A morpankh embellishment shall be fixed on the top of the bracket with two Nos of spot light to lit the morpankh embellishment. The decorative bracket should have the arrangement to fix the required luminaire. The bracket should have the arrangement suitable to be fitted on the required pole. The dimensions of the pole and bracket should be as per attached drawing. The Decorative Pole and Dual arm bracket Shall be machined and Polished properly to give it a smooth Surface. The Decorative pole with Dual arm bracket is duly pretreated by shotblasting process and painted in U.V. ray resistant P.U. coating in approved color shade. The Coating should have a minimum DFT of 90 microns and should pass a minimum of 300 Salt spray hours as per IS or ASTM testing methods. Decorative pole with double arm bracket shall be installed at desired location on existing foundation of the pole by making cement concrete foundation of 1:1.5:3( 1 cement: 1.5 course sand: 3 graded stone aggregate 40mm nominal size) with the help of anchor bolts and 38mm G.I sleeve as required. Weight of decorative pole and decorative double arm should be 165 kg and 5.5 kg x 2 nos arm respectively. Weight tolerance limit of pole & arm is +/-5%.Make:-Philips/Orient/Ligman/Neri/K-Lite/Pyrotech/Lustre/Surya/Bajaj |
| 4 | SITC of Decorative Ornamental pole with Tripple arm bracket. Total height of the pole with Three arm Bracket shall be 8000 mm nominal above the ground. The pole is made out of Combination of grooved and plain mild steel tube with cast aluminium pedestal. in three steps as shown in attached drawing. Cast aluminium embellishments are fitted with the help of grub screws. Dia and length of the bottom tubular section is 140mm x 4mm thick and 3000mm respectively which shall pass through the casted pedestal and welded with the baseplate and dia of grooved portion shall be reduced to 133mm. Dia and length of the middle section is 114mm x 3.6mmthick and 2700mm respectively. Dia and length of the top section is 89mm x 3.6mm thick and 1300mm respectively. Height of the pedestal shall be 715mm and dimensions of the base plate shall be 335mmx16mm thick. One Nos of morpankh embellishments made of cast aluminium shall be fitted on the upper section of the pole as shown in the attached drawing. A built in service window is provided to accommodate a 6 amp SP MCB and 32 amp heavy duty LILO connector for mains connections in the bottom part of the pole. The different sections of the pole are joined together by means of Welded joints. The decorative bracket is made out of mild steel, cast aluminium. The mild steel & cast aluminium part are joined together & are fabricated to get the desired design as per attached drawing. The dia of vertical and horizontal section of bracket shall be 76mmx3mm thick and 42mmx2.9mmthick respectively. A morpankh embellishment shall be fixed on the top of the bracket with two Nos of spot light to lit the morpankh embellishment. The decorative bracket should have the arrangement to fix the required luminaire. The bracket should have the arrangement suitable to be fitted on the required pole. The dimensions of the pole and bracket should be as per attached drawing. The Decorative Pole and Three arm bracket Shall be machined and Polished properly to give it a smooth Surface. The Decorative pole with Three arm bracket is duly pretreated by shotblasting process and painted in U.V. ray resistant P.U. coating in approved color shade. The Coating should have a minimum DFT of 90 microns and should pass a minimum of 300 Salt spray hours as per IS or ASTM testing methods. Decorative pole with triple arm bracket shall be installed at desired location on existing foundation of the pole by making cement concrete foundation of 1:1.5:3( 1 cement: 1.5 course sand: 3 graded stone aggregate 40mm nominal size) with the help of anchor bolts and 38mm G.I sleeve as required. Weight of decorative pole and decorative triple arm should be 165 kg and 5.5 kg x 3 nos arm respectively. Weight tolerance limit of pole & arm is +/-5%.Make:-Philips/Orient/Ligman/Neri/K-Lite/Pyrotech/Lustre/Surya/Bajaj |
| 5 | SITC of Decorative Led street light. Luminaire shall be made of Spun Aluminium and Cast Aluminium & shall have Ingress protection of IP66 for optical compartment and Impact Resistance of IK 08 or more. The Led Luminaire shall be in 110 w LED. A Transparent polycarbonate Diffuser shall be fitted in the Led Luminaire. The Dia and height of the Luminaire shall be 675mm x 710mm respectively. A Decorative Crown made of cast aluminium is fitted on the top of Luminaire. Integrated suitable BIS approved LED Driver shall be fitted inside the Led Luminaire having efficiency >85% power factor shall be > 0.95, THD |
| 6 | Add Extra in item no. 11.1 to 11.4 for Laying Charges for cable through Vermeer machine by making pit at regular interval and repairing the pit after laying of cable with PCC/ Bitumin as required. |
| 7 | 16.0 Sq. mm 4 core |
| 8 | Add Extra for Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade direct in ground including excavation of trench of size 75 cm (Depth) x 35 cm(Width) , with procedure as per following points:- (a) Make a river sand bed of height 125 mm along the trench, (b) Lay the cable in the middle of the trench, (c) Provide river sand bed of height 125 mm on top of the cable, (d) Lay the protective Common burnt clay F.P.S. Bricks of Class designation 75 / Sand stone slabs of 50 mm thickness and 225 mm wide just above the sand bed vertically across the cable ( Approx. 9 no. Bricks per Mtr.), (e) Backfill the excavated soil leaving 300 mm from the Ground level, (f)Lay the Cable warning tape and again back-fill the remaining portion of the trench upto the ground level and compacting the earth |
| 9 | Add Extra in Item no.11.5 if Excavation done in Hard Rock / CC road / TAR Road and making Good the same |
| 10 | P / L of Double wall corrugated HDPE pipe confirming to IS : 16205 P-24, Stiffness Class 750 N, Externally corrugated and having smooth surface inside with HDPE Coupler, Elbow, Tee at required Depth below the ground for laying cable of following Nominal Outer dia. MFR Test report from NABL accrediated is to be submitted.(Excavation of Earth & Back filling with compaction is to be Paid Extra)All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 50 mm |
| 11 | Supplying and making end termination with heavy aluminium lugs ( Pin / ring type ) confirming to IS 8309 -1993 & IS 8337-1976 duly crimped with crimping tool, PVC tape etc of following size.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 16.0 Sq.mm |
| 12 | Supply & Laying following size earth strip in horizontal or vertical run in surface by means of Earth strip DMC Insulator including riveting/ soldering/ welding, Jointing shall be done by overlapping and with 2 set of Brass (for Cu strip) / GI (for GI Strip) nut bolt & spring washer spaced at 50cm making connection etc. as required.All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . 20mm x 3mm G.I. ( Hot Dipped ) Strip |
| 13 | Providing and Laying RCC Foundation for Octagonal / Conical Street Light poles, High mast Poles as per Drawing attach at Table P-4 with Following Procedure & All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . Pole Foundation for Octagonal pole from 7 Mtr. To 9 Mtr. |
| 14 | Supply and installation of spike of M.S. rod 20mm dia 3.0mtr. long for earthing of (tower/pole) drive into earth by mechanical means sturcture connection the spike with cross arm top hamper PCC pole, lattics tower to earth etc. complete as per technical specification of DISCOM. |
| 15 | Supplying and drawing FR PVC insulated & unsheathed flexible copper conductor as per PWD specification for electrical Works with ISI marked (IS:694) and as per IS 8130 : 2013 of 1.1 kV grade . Wire should be made from 99.90 % purity copper, class 5 stranding in acc. to IS:8130/IEC 60228 for lower watt loss , oxygen free for less chances of oxidization, insulation PVC type A/C/D , flame retardant as per IS 10810-53, better amperage rating as per IS:3961 part 5, in existing surface or recessed PVC/ MS conduit/casing capping making connections with Copper Lugs of suitable size, Ferrules,testing etc. as required. OEM Must have its own in house NABL lab setup for all testing facilities for wires. For additional technical parameters of product / work refer Annexure 'A' attached with this BSR 2 x 1.5 sq.mm |
| 16 | Four pole MCB (With B/C curve tripping Characteristics) 50/63 A rating |
| 17 | 4 pole Power contactors with following AC 1 Rating 40 Amp |
| 18 | Providing & Fixing of mechanical / digital time switch having following day / week programme and minimum 100 hours reserve and AC1 rating of 16-20 amperes including making connection, programming conforming to IEC 60730-1 and 60730-2-7 etc. as required. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure \\"A\\" attached with this BSR . One day & week reserve (digital type ) Please Enable Macros to View BoQ information |