| 1 | Excavating in post holes in hard/dence soil (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm complete all as specified and directed. |
| 2 | M & L for PCC 1:2:4 type B-1 (using 20 mm graded agg) for fixing of post etc complete all as specified and directed. |
| 3 | M&L for Steel work in tubular square/rectangular hollow pipes in post, frame etc. complete using ERW or induction butt welded tubes complete all as specified and directed. |
| 4 | M&L for 0.63 mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc. as required complete all as specified and directed. |
| 5 | M&L for preparing new or previously untreated steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 6 | M&L for preparation and writing letters or figures (block, Roman, Italic or Indian) n.exc 30 CM height of synthetic enamel paint on steel surface over coat of ACE as matching with existing pattern complete all as specified & directed |
| 7 | Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165 complete all as specified and directed. |
| 8 | S & F hard drawn steel wire fabric cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia complete all as specified. |
| 9 | S&F Pre- painted galvatume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified |
| 10 | S &F 15 mm GI yellow corrosion resistant gas pipe including necessary fittings ,connecting of cylinder to store complete all as specified and directed |
| 11 | S &F of 4 inch dia gas line pressure guage complete all as specified and directed |
| 12 | M &L PCC Type- C-2 1:3:6 as in walls or retaining walls, any thickness, size or shape including pilasters, buttresses columns, pillars boundary pillars and posts (including caps and bases) complete all as specified and directed. |
| 13 | M & L cutting holes into or through or brick walls built in cement mortar superficial area exc 150 Sqcm and N exc 400 sqcm depth upto 30 cm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required complete all as specified and as directed. |
| 14 | M&L for hardcore broken stone of gauge n.exc 63mm deposited, spread, levelled in layers n.exc 15mm thick, watered and rammed to surface complete all as specified and directed. |
| 15 | M & L for 100mm thick cement concrete type B-1 1:2:4 using 20 mm graded aggregate complete all as specified and as directed by the Engineer-in-Charge |
| 16 | M& L for 100 mm thick Sand filling for placing cylinders complete all as specified and directed. |
| 17 | Taking down cement or cement lime plaster, any description, on brick or stone walls, etc including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and directed. |
| 18 | M&L Rendering 15mm thick Cement plaster 1:4 on fair faces of brick work or concrete sur faces finished even and smooth (without using extra lime or cement) complete all as specified and directed. |
| 19 | Preparation of new plastered surfaces of walls Material & Labour for applying Two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed. |
| 20 | M&L Rendering 10 mm thick Cement plaster 1:6 on fair faces of brick work or concrete sur faces rendering is to be finished even and smooth (without using extra lime or cement) complete all as specified and directed. |
| 21 | M&L Preparation of new plastered surfaces of walls and applying two coat of OBD white or tinted on walls over a coat of chalk whiting on plastered surfaces ,preparatory to distempering complete all as specified and as directed. |
| 22 | M&L preparing old decorated plastered or unplastered surfaces of walls and applying one coat of distemper oil emulsion, white or tinted complete all as specified and directed |
| 23 | M&L preparing old decorated plastered or unplastered surfaces of walls and applying one coat of cement base paint complete all as specified Please Enable Macros to View BoQ information |
| 24 | M&L preparing old decorated plastered or unplastered surfaces of walls and applying one coat of cement base paint complete all as specified Please Enable Macros to View BoQ information |