| 1 | DGSET |
| 2 | Carrying out Servicing of DG set up to 50 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 mins on load. Checking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping up with Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attendingbreakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge. (Non Comprehensive) as per specification No. GEN-SER-AMCCarrying out Servicing of 36.000 2,398.00 Job 86,328.00DG set up to 50 kVAwith/without AMF Panel of anymake to ensure smoothrunning of DG set for 30 minson load. Checking forabnormal sound and leakages,Carry out visual inspection ofall moving parts, oil levels, oilfilters, fuel filters, air filtersand clean them properly,rectify the minor leakages ifany. Inspect alternator, statorand rotor for normal speed &proper frequency, Examinebattery charging withmonitoring system andrecording voltages, checkingbattery cells gravity andtopping up with Distilledwater, Checking V belts withnecessary adjustment,Checking and retightening ofnut bolts including couplingbolts of engine and alternator,Checking & cleaning ofradiator and leakage testingChecking of radiator & fuelsupply hose pipes, Checkingof AVR, excitation diodes, itsconnections confirming properoutput voltage. Checking &resetting of valve tappets,Cleaning of DG set internallyusing blower, cleaningradiator, Attendingbreakdowns as and whenrequired during One monthperiod or during VIP visitwithin 2 hours of intimationand Submit the servicingreport to engineer in charge.(Non Comprehensive) as perspecification No.GEN-SER-AMC |
| 3 | Carrying out Servicing of DG set from 62.5 kVA to 200 kVA with/without AMF Panel of any make to ensure smooth running of DG set for 30 minsChecking for abnormal sound and leakages, Carry out visual inspection of all moving parts, oil levels, oil filters, fuel filters, air filters and clean them properly, rectify the minor leakages if any. Inspect alternator, stator and rotor for normal speed & proper frequency, Examine battery charging with monitoring system and recording voltages, checking battery cells gravity and topping upwith Distilled water, Checking V belts with necessary adjustment, Checking and retightening of nut bolts including coupling bolts of engine and alternator, Checking & cleaning of radiator and leakage testing Checking of radiator & fuel supply hose pipes, Checking of AVR, excitation diodes, its connections confirming proper output voltage. Checking & resetting of valve tappets, Cleaning of DG set internally using blower, cleaning radiator, Attending breakdowns as and when required during One month period or during VIP visit within 2 hours of intimation and Submit the servicing report to engineer in charge. (Non Comprehensive) as per specification No. GEN-SER-AMC |
| 4 | Supplying and erecting V-Belt of all types and lengths, adjust tension as per requirements from generators manufactured suitable for DG Set up to 200 KVA |
| 5 | Supplying and erecting V Belt of all types and lengths, adjust tension as per requirement from generators manufacturer suitable for DG set from 125 KVA to 250 KVA |
| 6 | Supplying and erecting lub oil filter element along with sealing rings, gasket, etc. complete suitable for DG set up to 160 KVA |
| 7 | Supplying and erecting Fuel filter along with sealing rings, gasket, primary filter and water separators etc, complete suitable for DG Setup to 160 KVA |
| 8 | Supplying and erecting Air cleaner/ Air Filter element suitable for DG Set up to 63 KVA |
| 9 | Supplying and erecting Air cleaner/ Air filter element suitable for DG set from 100 KVA to 160 KVA |
| 10 | Supplying and erecting Air cleaner/ Air Filter element suitable for DG Set up to 63 KVA |
| 11 | Supply and refelling new lubricating oil 15 W/40 Grade for E/A set |
| 12 | Supply and refilling glycol based 50//50 with operating range from 118°C to -37°C |
| 13 | Supplying and erecting V/150Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete |
| 14 | Supplying and erecting V/180Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complete |
| 15 | Operation and maintenance of 160KVA DG set in 3 shift at IT Tower Building, Parsodi Nagpur as & whenever required including checking and maintaining all the parameters like power supplyto IT units in this building registering MSEDCL power failure complaints and getting required solution, maintaining electrical installation ,pumping machinery as and whenever required. |
| 16 | Providing & erecting 3 Pole MCCB, 415V, up to 100A, rated short-circuit breaking capacity 25 kA (Ics=100% of Icu), adjustable thermal (overload) setting and fixed magnetic setting with provided leads, provision for installation of shunt/UV/tripalarm contact. MCCB with phase barriers on both sides, insulation withstand capacity 800V, no line load bias in provided enclosure/panel as per specification no. SW-MCCB |
| 17 | Providing & erecting 3 Pole MCCB 415V, 250A, rated short-circuit breaking capacity 36 kA (Ics=100% of Icu) adjustable thermal (overload)setting and adjustable magnetic setting withprovided leads, provision for installation of shunt/UV/trip alarm contact. MCCB should have phase barriers both sides, with insulationwithstand capacity 800V, no line-load bias in provided enclosure/panel as per specification no. SW-MCCB Please Enable Macros to View BoQ information |