| 1 | Dismantling roofing including ridges, hips, valleys and gutters etc., and stacking the material within 50 metres lead of: Asbestos cement sheet |
| 2 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces,excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 3 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : ) Ridges plain (500 - 600mm) |
| 4 | Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking outjoints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge. With cement mortar 1:4 (1 cement : 4 fine sand) |
| 5 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. |
| 6 | Dismantling and stacking within 50 metres lead, fencing posts or struts including all earth work and dismantling of concrete etc. in base of: 15.34.1 T’ or ‘L’ iron or pipe |
| 7 | Dismantling barbed wire or flexible wire rope in fencing including making rolls and stacking within 50 metres lead. |
| 8 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 9 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : 15.12.2 Of area beyond 3 sq. metres |
| 10 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. 2.8.1 All kinds of soil. |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns Upto GL |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, piers, abutments, pillars, posts and struts Above GL |
| 13 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size) |
| 14 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.l. Thermo-Mechanically Treated bars of grade Fe-500 D or more |
| 15 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.l. Thermo-Mechanically Treated bars of grade Fe-500 D or more |
| 16 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 17 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 5.2.2 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 18 | Providing and laying cement concrete in retaining walls, return walls, walls (any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor,etc., up to floor five level, excluding the cost of centering, shuttering and finishing: 1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) |
| 19 | 12 mm cement plaster of mix : 1:4 (1 cement: 4 fine sand) |
| 20 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Gate Total Compalete with Hold fast, aldrop, etc .( 35.00 kg /sqm) |
| 21 | Filling available excavated earth (excluding rock) in trenches, plinth sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, leadup to 50 m and lift upto 1.5 m. |
| 22 | RCC Precast Pre-Stressed Compound Wall RCC Precast Pre-Stressed Plank - 1830mm X305mmX50mm (6ft x 1ft x 2Inch) Plank with 3 No bars of 3mm HTS Steel and M-25Grade of Concrete UsedRCC Precast Pre-Stressed Column -2745mm150mmx150mmX(9ft x 6Inch x 6Inch) Column with 7 No bars of 3 mm HTS Steel and M-25 Grade of Concrete Used for 2134mm(7ft) height precast wall above NGL Cement Concrete M 25 Foundation :450mmX450MMX610MM(1.5ft x 1.5ft x 2ft).This item is included loading, unloading, transportation, Foundation Excavation ,foundation concrete material and Installation/Erection as per direction of Engineer - in- charge. |
| 23 | Applying priming coat: 13.50.3 With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 24 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : 13.62.1 Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture |
| 25 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :13.99.1 One or more coats on old work |
| 26 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratchesetc. Complete |
| 27 | Finishing walls with acrylic smooth exterior paint with silicone additives of required shape: New work (Two or more Coat applied @ 1.67 lit/10 sqm over and including priming coat of exterior primer [email protected] lit/ 10 sqm |
| 28 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. Nominal concrete 1:4:8 or leaner mix (i/c equivalent design mix) |
| 29 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.11.3.1 40 mm thick with 20 mm nominal size stone aggregate |
| 30 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easilyGlazed Vitrified tiles Matt/Antiskid finish of size11.41A.3.1 Size of Tile 600 x 600 mm |
| 31 | Dismantling W.C. Pan of all sizes including disposal of dismantled materials including malba all complete as per directions of Engineer-in-Charge |
| 32 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 33 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. 18.7.2, 20 mm nominal outer dia Pipes metre. |
| 34 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. 15 mm nominal bore |
| 35 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a single 15 mm C.P. brass pillar tap each |
| 36 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete Flexible pipe 32 mm dia |
| 37 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. 9.165.1 125 mm |
| 38 | Providing and fixing ISi marked oxidised M.S. door latches conforming to IS:5930 with screws etc. complete :9.65.1 300x20x6 mm |
| 39 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameterRemark- This pipe is used as soil pipe to connect office building toilet & Bathroom to septic tank |
| 40 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion. Bend 87.5°110 mm bend |
| 41 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with piano type switch, phenolic laminated sheet, suitable size MS box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required 1.1.1 Group A |
| 42 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. asrequired. 5/6 amps switch |
| 43 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. asrequired 3 pin 5/6 A socket outlet |
| 44 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. asrequired. 15/16 A switch |
| 45 | Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. asrequired. 6 pin 15/16 A socket outlet |
| 46 | Supplying and fixing following way, single pole and neutral ,sheet teel,MCB distribution board,240 V,on surface /recess,complete with tinned copper bus bar,neutral bus bar,earth bar,din bar,interconnections ,powder painted including earthing etc.as required.(But without MCB/RCCB/Isolator)2.3.1 6 way ,Double door |
| 47 | Supplying and fixing 5A to 32 Arating,240/415 V,10 kA,\\"C\\" Curve, miniature circuit breaker for inductive load of following poles in the exisring MCB DB complete with connections,testing and commissioning etc. as required.2.10.3 Double Pole |
| 48 | Supplying and fixing 5A to 32 Arating,240/415 V,10 kA,\\"C\\" Curve, miniature circuit breaker for inductive load of following poles in the exisring MCB DB complete with connections,testing and commissioning etc. as required.2.10.1 Single Pole |
| 49 | Supplying and fixing following rating,double pole,(single phase and neutral),240 V,residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections,testing and commissioning etc.as required2.14.3 63A |
| 50 | Wiring for light/power plug with 2x4 sq.mm FRLS PVC insulated copper conductor single core cable in surface /recessed medium class conduit along with 1 No. 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as required |
| 51 | Wiring for circuit/submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed medium class PVC conduit as required.1.14.3 2x4 sq.mm+1x4 sq.mm earth wire |
| 52 | Earthing with G.I. earth pipe 4.5 Meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 53 | Supplying and laying 6 SWG G.I. wire at 0.50 Meter below ground level for conductor earth electrode, including connection/ termination with GI thimble etc. as required. Please Enable Macros to View BoQ information |