| 1 | Vector network analyser 10MHz to 40GHz with dual-port base hardware configuration and Time domain analysis feature (having all the required hardware and pre-loaded software to carry out Material Characterization) | Vector network analyser 10MHz to 40GHz with dual-port base hardware configuration and Time domain analysis feature (having all the required hardware and pre-loaded software to carry out Material Characterization) |
| 2 | Material measurement software suite for free space measurement method, Transmission line measurement method and Thin film sheet measurement method with Hardware key | Material measurement software suite for free space measurement method, Transmission line measurement method and Thin film sheet measurement method with Hardware key |
| 3 | Spot focusing antenna setup, one set each (Qty 2 No’s) for C band, X band, Ku band, K Band, Ka band with Dielectrics lens and standards for calibration (as per scope of work). | Spot focusing antenna setup, one set each (Qty 2 No’s) for C band, X band, Ku band, K Band, Ka band with Dielectrics lens and standards for calibration (as per scope of work). |
| 4 | Waveguide Transmission line measurement setup along with standards for calibration, frequency range: 2.6 to 40GHz. (as per scope of work). | Waveguide Transmission line measurement setup along with standards for calibration, frequency range: 2.6 to 40GHz. (as per scope of work). |
| 5 | Thin film Sheet measurement setup along with standards for calibration, frequency range: 800MHz to 40GHz. (as per scope of work). | Thin film Sheet measurement setup along with standards for calibration, frequency range: 800MHz to 40GHz. (as per scope of work). |
| 6 | Data controller computer for acquisition and analysis | Data controller computer for acquisition and analysis |
| 7 | Antenna Lab setup as per sow, aluminium rack for placing all the equipments & test bench fixtures. | Antenna Lab setup as per sow, aluminium rack for placing all the equipments & test bench fixtures. |
| 8 | 3 & 5 meter RF Cable Assembly with K type Male to Male Connectors for 40GHz - 4 Nos each. | 3 & 5 meter RF Cable Assembly with K type Male to Male Connectors for 40GHz - 4 Nos each. |
| 9 | ECal module 10MHz to 40GHz, 2-port, 2.4mm adapters, male and female connectors with Torque wrench -1 each | ECal module 10MHz to 40GHz, 2-port, 2.4mm adapters, male and female connectors with Torque wrench -1 each |
| 10 | Adapters: 1. 2.4 mm Female to K Type Female Adapter - 4Nos2. 3.5 mm female to Type N Male Adapter - 4 Nos 3. 3.5mm (f) to N-type (m) – 2 Nos 4. 2.4mm (f) to 2.92mm (f) – 2 Nos | Adapters: 1. 2.4 mm Female to K Type Female Adapter - 4Nos2. 3.5 mm female to Type N Male Adapter - 4 Nos 3. 3.5mm (f) to N-type (m) – 2 Nos 4. 2.4mm (f) to 2.92mm (f) – 2 Nos |
| 11 | Test port cables, 3ft. 2.4mm (m-f) - 2nosCoaxial to Waveguide Adapter, 2.4 mm female to WR-28, 26.5 to 40 GHz-2nosCoaxial to Waveguide Adapter, 3.5 mm female to WR-42, 18 to 26.5 GHz-2nos | Test port cables, 3ft. 2.4mm (m-f) - 2nosCoaxial to Waveguide Adapter, 2.4 mm female to WR-28, 26.5 to 40 GHz-2nosCoaxial to Waveguide Adapter, 3.5 mm female to WR-42, 18 to 26.5 GHz-2nos |
| 12 | Waveguide to Type-N (f) Adapter, X-Band, 12.4 GHz-2nos, Waveguide to APC-7 Adapter, P-Band, 18 GHz-2nos | Waveguide to Type-N (f) Adapter, X-Band, 12.4 GHz-2nos, Waveguide to APC-7 Adapter, P-Band, 18 GHz-2nos |
| 13 | Sample materials (S glass, E glass, RT Duriod, Quartz, FR4), minimum 6×6 inch and 8×8 inch. | Sample materials (S glass, E glass, RT Duriod, Quartz, FR4), minimum 6×6 inch and 8×8 inch. |
| 14 | Calibration certificates with test data | Calibration certificates with test data |