| 1 | Taking down old unserviceable LT Panel and Supply, fixing, connecting and commissioning of LT panel, factory made (CPRI approved), Indoor/outdoor type (kiosk), floor mounted, compartment type, dust and vermin proof (IP-55 protection) suitable for 415 volts grade, 3 phase, 4wire 50Hz AC supply with 400 Amp aluminium bus bar TPN, colour coded & sleeved, fabricated out of 3.15 mm thick mild steel CRCA sheet mounted on 50mmx50mmx6mm angle iron frame and welded to 75cm long 50mmx50mmx6mm size angle iron legs (04 Nos), front & rear openable, with front hinged double door inclusive locking arrangement with provision of all incoming/outgoing cable entries alongwith suitable size double compression type cable glands and adopter boxes for incoming and outgoing cable & spray painting with two coats of first quality super enameled grey paint over and including a coat of red oxide primer, including anti-corrosive treatment (7 tank), legs grouted in floor in PCC (1:2:4) bed block of size 30cmx30cmx60cm, complete all as specified and directed, comprising the following :- (a) MCCB 250 Amp, 4 pole, 415 Volt, 50Hz, AC, with rupturing capacity 25 KA with adjustable thermal and fixed magnatic release (I/C) - 01 No. (b) MCCB 160 Amp, 4 pole, 415 Volt, 50Hz, AC, with rupturing capacity 25 KA with adjustable thermal and fixed magnatic release (O/G) - 02 No.(b) MCCB 100 Amp, 4 pole, 415 Volt, 50Hz, AC, with rupturing capacity 16 KA with adjustable thermal and fixed magnatic release (O/G) - 02 No.(c) On Load Change Over Switch I-O-II , 320 Amp, 4 Pole, 415 Volt, 50 Hz - 01No.(d) Pre-wired Digital meter with voltmeter, ammeter, slector switch, CTs and LED Indication Lights- 01 Set.(e) Bus bar chamber with electrolytic grade aluminum strip with heat shrink cable sleeves with colour code supported on epoxy resin based insulator 4 strips of suitable length for current rating 400 A. |
| 2 | S&F cable end joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size 150 to 240 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed |
| 3 | S&F cable end joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size 70 to 120 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed |
| 4 | S&F cable end joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size upto 70 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed |
| 5 | S&F cable Straight Through joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size 150 to 240 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed |
| 6 | S&F cable Straight Through joint joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size 70 to 120 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed |
| 7 | S&F cable Straight Through joint joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size upto 70 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed |
| 8 | Supply and fixing LT Cable route indicator made up of cast iron and marked with LT and mounted on flat iron/angle iron of suitable sixe round writing LT Cable with back side welded flat iron including PCC block 30 x 30 x 20 cm complete all as directed and specified. |
| 9 | Taking out old unserviceable LT UG PVC/ XLPE cable of any size 1100 v laid in trenches/on poles through GI protection pipe NOTE: Excavattion and earthwork shall be measuured and paid for separately under respective items. |
| 10 | Supply & laying of UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 150 Sqmm 3.5 core laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. NOTE: Excavation and earth work shall be measuured and paid for separately under respective items . |
| 11 | All as per item no 10 here-in-beforee but size 120 Sqmm 3.5 core . |
| 12 | All as per item no 10 here-in-beforee but size 95 Sqmm 3.5 core . |
| 13 | All as per item no 10 here-in-beforee but size 70 Sqmm 3.5 core. |
| 14 | All as per item no 10 here-in-beforee but size 35 Sqmm 3.5 core. |
| 15 | All as per item no 10 here-in-beforee but size 25 Sqmm 4 core. |
| 16 | All as per item no 10 here-in-beforee but size 25 Sqmm 2 core. |
| 17 | All as per item no 10 here-in-beforee but size 16 Sqmm 2 core. |
| 18 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge. |
| 19 | Material and labour for sand cushioning below and around cable in trenches with rever sand all as specified & directed. |
| 20 | M&L for un-reinforced precast concrete cable cover, class LV, type 1, flat of size 250 x 150 x 40 mm for cable protection complete all as specified and as directed. |
| 21 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed. |
| 22 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 23 | Material & labour for cutting existing road/Hard Rock/ PCC hard Standing/ pavement/ drain for taking out / laying of undergroung water pipe/ cable passing through suitable size of GI Pipe line and including necessary earth work and making good to match with the existing surface with PCC work in type B2 (1:2:4) cement mortar with 40mm graded aggregate complete all as specified and as directed. |
| 24 | Mild steel galvanized tubes light grade ISI marked 80 mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe, compllete all as specified and as directed. |
| 25 | Mild steel galvanized tubes light grade ISI marked 50mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe, compllete all as specified and as directed. Please Enable Macros to View BoQ information |
| 26 | Mild steel galvanized tubes light grade ISI marked 50mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe, compllete all as specified and as directed. Please Enable Macros to View BoQ information |