| 1 | Interior Acoustic |
| 2 | Providing and fixing false ceiling of 12.5 mm thick decorative boards of fibrous plaster of Paris including frame work of galvanized iron for suspended false ceiling which includes galvanized iron perimeter channels of size 27 mm & 0.5 mm thick having one flange of 20 mm and another of 30 mm along with perimeter of the ceiling, fixing in brick wall / partition with the help of rawal plugs and screws, suspending galvanized iron intermediate channels of size 45 mm and 0.9 mm thick with two flanges of 15 mm each from the soffit at 1200 mm centers with steel galvanized iron hanger of width 25 mm x 0.5 mm fasteners, ceiling section of 0.5 mm thickness having curved wedge of 51.5 mm and two flanges of 26 mm each with lips of 10.5 mm fixed to the intermediate channel with the help of connecting clips and in direction perpendicular to the intermediate channel at 450 mm centers, 12.5 mm dry walls screws at 230 mm centers; fixing screws mechanically either with screw driver or drilling machine with suitable attachment etc. including scaffolding if necessary for all architectural work like moldings', cornices, coves, domes, cups as per detailed drawings etc. complete As directed by Architect / Engineer in charge. |
| 3 | Providing & Fixing of Armstrong OR equivalent Mineral Fiber Acoustical System with Fine Fissured (Bevelled Tegular) Edge, 15mm Exposed Grid. The tiles should have Humidity Resistance (RH) of 99%,NRC 0.6, Light Reflectance ≥85%, Thermal Conductivity k = 0.052 - 0.057 w/m K, Colour White, Fire Performance UK Class 0 / Class 1 (BS 476 pt - 6 &7) in module size of 600 x 600 x 16mm , with Recycled content of 31 %. The tile shall be Fixed on existing GI grid Work On wall /ceiling Complete et. As per Engineer In Charge/Architect |
| 4 | Providing & laying / fixing Glasswool of 32 Kg/m3 density, 50mm thk. Wrap in non woven 70gsm fabric. Owens Corning ,or twiga insul, or equivalent etc complete As directed by Architect |
| 5 | Providing and applying 2 coats of Acrylic Emulsion paint of approved colour and shade to ceiling after thoroughly sand papering surfaces to remove dust, dirt etc. and repairing dents, cracks, holes with POP to achieve level surface and finishing with one coat of primer, putty and two coats of paint including cost of material, labour, etc. all complete as directed by the Architect / Engineer in charge. Rate applicable for all heights and levels, surfaces and textures. Engineer in charges' approval required after each coat. Tenderer to submit sample to the Engineer in charges for approval. |
| 6 | Providing and applying 2 coats of Royal Emulsion Paint of approved colour and shade to internal walls after thoroughly sand papering surfaces to remove dust, dirt etc. and repairing dents, cracks, holes with POP to achieve level surface and finishing with one coat of primer, putty and two coats of paint including cost of material, labour, etc. all complete as directed by the Engineer in charge. Rate applicable for all heights and levels, surfaces and textures. Engineer in charges' approval required after each coat. Tenderer to submit sample to the Engineer in charges for approval. |
| 7 | Providing and applying 2 coats of primer on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required. all complete as directed by the Architect / Engineer in charge. Rate applicable for all heights and levels, surfaces and textures. Engineer in charges' approval required after each coat. Tenderer to submit sample to the Engineer in charges for approval. |
| 8 | Stage wall paneling/auditorium side wall paneling - Providing & Fixing Ecophon panel - A- Akutex FT (or equivalent) 1200x600 board wall panel 40 mm thk with angural square edge, demountable panel with approved fabric wrapped around in concealed gripper system. Pannel manufactured from high density glass wool and recycled content of minimum 70% covered with glass tissue on one side the glass wool core of the tiles should be tasted and classified as non combustible according to PERN ISO 1182. The system should have sound absorption NRC value of 0.9 (according to EN ISO 11654) the tile should withstand a permenent ambient RH upto 95% at 30 degree C without sagging wraping or delamination (ISO 4611) Ecophon board screwed to G.I frame with screws @ 200 c/c Frame - G.I frame fabricated with sal wood spacers ai 610 c/c vertically & @ 1220mm c/c horizontally as per profile of paneling in dwg 50x37.5x0.5 floor & ceiling channels at top and bottom edges 50x37.5x0.5xc channels section at 1220 c/c vertically 80x26x0.5 ceiling section at 400 c/c horizontally complete as per manufacturesrs specifications including 50mm thk 32 kg/m3 density glasswool in between GI frame wrapped in nonwoven fabric (70gsm) etc complete all as per detailed drawing and instructions from archtiect. Rate applicable for all heights and levels, surfaces and textures. |
| 9 | Fabric Panels on Side Walls-Providing & Fixing in position, Acoustical Paneling made from 50mm acoustical fabric panels [on G. I. Frame of ceiling channels as per manufacturer's specifications, pervaded with 48 Kg /CUM glass wool 50 mm thick with first layer of nonwoven acoustically transparent fabric and second layer of acoustically transparent fabric of approved colour including cost of required Cut-Outs, as per Architectural & Acoustical Design & Instructions & Complete in all aspects as per details & directed by Architect / Engineer- In-Charge including loading and unloading charges, Rate applicable for all heights and levels, surfaces and textures. |
| 10 | Providing/fixing 4mm thk veneer wall paneling with hard wood frame of 50mmX50mm @610mm c/c both ways & stated directions as per drawing. Frame shall be covered with 12mm thk. BWP Grade ply with 4mm thk veneer, including all necessary Polishing & finishes as apporved by Architect. including 50mm thk 32 kg/m3 density glasswool in between frame wrapped in non woven fabric (70 gms). Anti-termite treatment to internal surface of frame & ply by aldrex, complete as directed by architect. |
| 11 | Providing & fixing of Synthetic washable carpet of 1000 gsm loop pile woolen / nylon carpet with 6mm thk underly to be fixed property using correct adhesive for fixing of carpet as per manufacture specifications all as per desing shade & make of apporved by Architect & Consultant Make - NexGen / equivalent |
| 12 | Providing & pasting Vinyl wall paper on POP / plywood surface including necessary surface preparation & adhesive etc complete All as approved & directed by Architect |
| 13 | Providing and applying plaster with Gypsum Plaster in 6-8 mm thickness to previously plaster surface in all position including preparing the surface scaffolding etc. complete. As directed by Engineer in Charge. |
| 14 | Providing & Fixing 125 mm thk Acoustical fire rated door for Auditorium, shutter finished with 4mm thk veneer on both sides Frame:Door shall be made in saalwood frame in 75 x 37.5mm frame all round as shown & 50 x 37.5mm intermediate frame 600mm c/c vertically. Frame shall have both sides 12mm thk fire rated ply finish with 4mm thk Veneer including 3 coats of melamine polish on veneer surface complete with machine sanding etc . Glass wool of 50mm thk, 48kg/m3 density shall be kept in between wooden frame. Door shutter to have two rebates having thin felt lining for making air tight door and drop seal at bottom of shutter. Fixing 1 layer of 2.5mm thk Tecsound insulation and 1 layer of 12.5mm thk plain Gypsum board in between two frames complete. Work will be carried out as per drg & instruction of Acoustic consultant / Site Engineer Incharge / Architect. Size of door as per site conditions (including frame) SHUTTER: The shutter shall have double rebates on vertical and top edges with provision for EPDM doorseal fixing in one rebate and intumescent smoke stop strip fixing in second rebate. INTUMESCENT STRIP- 1no per shutter,proprietary shielded intumescent smoke stop strip in one rebate on three edges except the bottom. SILICON DOORSEALS - 1no per shutter in 1 rebate on 3 edges except the bottom as approved, HINGES - 100x150x6 Brass Hinges as approved 4nos per shutter. HANDLES - Stainless Steel handle as per design approved, 2 nos per shutter,stainless steel (304 grade)hairline finish,40mm diameter,750 mm long on pull side of the Auditorium doors, 1 number per shutter. DOOR CLOSER – a) IR – LCN - 3133 Concealed heavy-duty door closer, 1 no per shutter., hold open type door closer or equivalent. AUTOMATIC DOOR BOTTOM – HAGER Automatic door bottom 740 ‘S’ as per the requirement. 1no per shutter at the bottom edge.2 Nos per door. Panic Device - Dorma PHA 2000 Push Type Panic Bar for Double Rebated Door or equivalent. 1) On active leaf: PHA 2105- Single point locking, modular, for fire and smoke doors with a door width up to 1300mm, with security anti thrust latch and dogging device. Steel latch, steel latch keep with spacer.2) On inactive leaf: PHB 2202 – Top and bottom lock combination, for fire & smoke check doors, with security anti thrust latch. Steel latch, steel top latch keep with spacer plates, steel bottom latch keep.3) PHB 2203:- Connecting rod set with cover for door heights up to 2270 mm steel latch keep with spacer plates for double doors (without trim) 4) Key with lever handle for Panic Device Model: 3905. Work will be carried out as per drg & instruction of acoustic consultant /Site Engineer In charge /Architect. Including transportation and all taxes and excluding GST. Specification as directed. |
| 15 | Stage Floor - Providing & fixing in position Stage flooring using 30 mm thick (100-125mm W, 1200-1500mm L) Teak wood planks on 18 mm BWP grade ply screwed to hard wood frame of 50 x 50 mm wooden sections at 610mm c to c both ways on stage surface, as per Architectural, Acoustical Design & Instructions & Complete in all aspects. As directed by Architect / Engineer- In- Charge, include transport loading and unloading charges |
| 16 | Providing & applying Wax polishing for stage including all required surface preparation in approved shade etc complete As directed by Architect |
| 17 | Providing & applying Wax / Melamine polishing for existing paneling including all required surface preparation in approved shade etc complete As directed by Architect |
| 18 | Box type EXIT Singaes (Red color LED) without battery backup as per approved samples and as directed by architect |
| 19 | LECTURN providing & Fixing podium table in 19mm thk BWP grade ply with 4mm vineer facing as shown in dwg. Table shall have 300x300x10 mm square toughened glass fixed on studs, in front side of tale with logo as per client. Table shall include one reading lamp with 12 mm thk soft board finished with fabric as approved and reading light point as indicated in the drawing all surfaces shall be finished with 4mm thk venner and 3 coats of melamine polish size:-750x600x1200mm X2nos |
| 20 | Providing making & supplying mixer table 1800mmx750mmx700mm size in 19 mm thk BWP grade ply with 1 mm thk laminate finish and with 75x37.5mm footrest in salwood as per drawing. Table shall be made in 19 mm thk BWP grade ply with sides & top along with front and draw finished in laminate, finished Table top shall have necessry cut out for audio mixer approved and instruction on site including s.s handles locks and necessary hardware like sliding channels etc. internal surface shall be finished with two coats of french polish size |
| 21 | SITC of high performance mass loaded Sound Barrier for quiter enviornment, vinyl sound barrier mat 2 - 2.5 mm thk thermoplastic polymer compound, materrial free from asphalt. Density 2000kg/cum, wt 5kg/sqm, tensile strength MC/CD>1.8 MPa.Make - Techsound / Tikidan / Equivalent |
| 22 | Providing and fixing in position hard wood for re strenthening for existing partion and paneling work, stage, balcony facia as required. |
| 23 | Providing and fixing double scaffolding system (cup lock type) on the exterior side of building/structure, including additional rows of scaffolding in stepped manner as per requirement of site, made with 40mm dia M.S. tube, placed 1.5 metre centre to centre, horizontal & vertical tubes joint with cup & lock system with M.S. Tubes, M.S. tube challis, M.S. clamps and staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for execution of work of cleaning and/ or pointing and/ or applying chemical and removing it thereafter. The scaffolding system shall be stiffened with bracings, runners, connecting with the building etc, wherever required, if feasible, for inspection of work at required locations with essential safety features for the workmen etc., complete as per directions and approval of Engineer-in-charge. Note:- (1) The elevational area of the scaffolding shall be measured for payment purpose. (2) The payment will be made once only for execution of all items for such works. |
| 24 | Dismantling of wall paneling including frame work, glasswool etc, stacking the materials as directed with all leads, lifts & disposal as required etc. complete As directed by Architect In Charge |
| 25 | Removing of existing Single/Double doors with framework and all accessories/hardware without damaging the same and surroundings by carefully chasing adjoining wal. The rate to include stacking the same, at site (may be reused for any areas) and / or in the ground floor premises including all labour, tools etc complete for all locations and levels as directed and instructed by site in charge. Please Enable Macros to View BoQ information |