| 1 | Earth work in excavation by mechanical means (Hydraulicexcavator )/ manual means over areas (exceeding 30cm indepth. 1.5m in width as well as 10 sqm on plan) includingdisposal of excavated earth, lead upto 50m and lift upto 1.5 m, disposed earth to be levelled and neatly dressed : All kindsof soil |
| 2 | Providing and laying in position cement concrete includingcuring, compaction etc. complete in specified grade excludingthe cost of centering and shuttering - All work up to plinthlevel M10 grade Nominal Mix1: 3: 6 (1 cement : 3 coarse sand : 6 graded stone aggregate20mm nominal size). |
| 3 | Providing and fabricating reinforcement for R.C.C. workincluding straightening, cutting, bending, placing in positionand binding (including cost of binding wire) all complete up tofloor five level. Thermo-mechanically Treated bars (Conforming of relevent IScode) |
| 4 | Providing and laying in position specified grade of cementconcrete for RCC structural elements upto floor five levelincluding curing, compaction, finishing with rendering incement sand mortar 1:3 (1 cement: 3 coarse sand) and makinggood the joints and cost of plastizers( if required) excludingthe cost of centering, shuttering and reinforcement for Beams,suspended floors, roofs, griders having slopes up to 15º,landings, balconies, shelves, chajjas, lintels, bands, plainwindows sills, staircases and spiral staircases etc.M20 grade Nominal Mix / Design Mix |
| 5 | Centering & shuttering with plywood or steel sheets includingstrutting, propping bracing both ways with steel props andremoval of formwork for upto floor five level for :Suspended floors, roofs, landings, staircases, balconies,girders, cantilevers, bands, coping bed plates, anchor blocks,sills, chhajjas, lintel, beam, plinth beam etc. |
| 6 | Providing and laying APP (Atactic Polypropylene Polymer)modified prefabricated five layer 3mm thick water proofingmembrane, black finished reinforced with glass fibre mattconsisting of a coat of bitumen primer for bitumen membrane@ 0.40 Itr/sq.mt. by the same membrane manufacture ofdensity at 25°C, 0.87-0.89 kg/ltr and viscosity 70-160 cps.Over the primer coat the layer of membrane shall be laid usingButane Torch and sealing all joints etc., and preparing thesurface complete. The vital physical and chemical parametersof the membrane shall be as under Joint strength inlongitudinal and transverse direction at 23°C as650/450N/5cm. Tear strength in longitudinal and transversedirection as 300/250N. Softening point of membrane not lessthan 150°C. Cold flexibility shall be upto -2°C when tested inaccordance with ASTM, D-5147. The laying of membraneshall be got done through the authorized applicator of themanufacturer of membrane.3 mm thick |
| 7 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC)pipes (IS 15778 : 2007 code) having thermal stability for hot& cold water supply including all CPVC plain & brassthreaded fittings i/c fixing the pipe with clamps at 1 metrespacing. This includes jointing of pipes & fittings with onestep CPVC solvent cement and testing of joints complete asper direction of Engineer in Charge. (Internal work Exposedon wall) 25 mm nominal size |
| 8 | P&F rigid PVC Pipe (IS:4985 mark) class II/ (4 Kg. /Cm2 . ) approved quality /make including joining the pipe with solvent cement rubber ring and lubricant 110 mm dia |
| 9 | P&F rigid PVC pipe fittings (IS: 4985 mark) of approvedquality /make including joining the pipe with solvent cementrubber ring and lubricant:Coupler (socket) 110mm dia |
| 10 | Bend 45, 110mm dia |
| 11 | Structural steel work in single section fixed with or withoutconnecting plate including cutting, hoisting ( height upto 10m), fixing in position and applying a priming coat of approvedsteel primer all complete |
| 12 | Brick masonry with F.P.S. bricks of class designation 75 infoundation and plinth with bricks Cement mortar 1 : 6 (1 cement : 6 coarse sand) |
| 13 | SITC of Monoblock motor pump set ISI marked (IS:9079-2002) with TEFC motor, motor should be IE2 class as per IEC 60034-2-1: 2007, IEC 60034-30: 2008, & IS12615:2011. with Stainless steel Impellor, Stainless steel shaft, Mechanical seal, Single/Three phase ( 240 -440 V ) permanent split capacitor type (PSC), fitted with thermaloverload protection, Including cost of hardware etc on existingplatform complete. Pump shall have following HP Rating, phase,Head, minimum Discharge respectively complete in all respect.OEM shall have submit NABL / CPRI / ERDA accrediated lab type test certificate before execution. All as per pre approved byEngineer in charge. For additional technical parameters ofproducts/ work , refer Annexure \\"A\\" attached with this BSR 1.5 HP, 1-Ø, (6-24)Mtr, (400-80) LPM |
| 14 | P & F G.I. Pipes (External Work) with G.I. fittings excluding union(IS : 1239 Mark) including trenching & refilling earth etc.100mm dia nominal bore 'A' Class Please Enable Macros to View BoQ information |