Tender For Deposit-Govt . Ayurveda Dispensary , Peruvanthanam -Inverter Supply-Supply And Installation Of Inverter System-General Electrical Work
Tender Value
Ref. Documents
Estimated cost
Bid Submission
28 May 2026
0 days left
EMD
2045
Bank guarantee accepted
Document Fee
850
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Peruvanthanam → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Tender for Deposit-Govt . Ayurveda Dispensary , Peruvanthanam -Inverter Supply-Supply And Installation Of Inverter System-General Electrical Work
BOQ
| Sl. No. | Item Description |
| 1 | Providing inverter @ayurvedha hospital paloorkavu peruvanthanam |
| 2 | 1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire |
| 3 | 1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 4 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 5 | 2.12.1:Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 6 | 2.14.1:Supplying and fixing following rating, double pole, (single phase and neutral),240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 7 | 2.3.2:Supplying and fixing following way, single pole and neutral, sheet steel, MCBdistribution board, 240 volts, on surface/ recess, complete with tinned copperbus bar, neutral bus bar, earth bar, din bar, interconnections, powder paintedincluding earthing etc. as required. (But without MCB/RCCB/Isolator)8 way, Double door |
| 8 | 1.32:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required. |
| 9 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top |
| 10 | 5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required. |
| 11 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 12 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 13 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 14 | OD283033/2025-2026:Supply, conveyance, installation, testing and commissioning of 2 KVA sine inverter working by 24 Volt DC supply with battery charging unit with indications ,input voltage 150-270V AC supply , Output voltage 230V +/-3%, 50 Hz +/- 1% and Short circuit,over/under voltage,surge & spike protections including giving connection etc (EXIDE/LIVEGUARD or equalent ) with supply and fixing of 2 Nos 12V 105 AH fully charged Lead acid Tubular Battery with terminal leads for the existing 2 KVA inverter unit (EXIDE or equivalent) including battery and inverter cabinet |
| 15 | OD214877/2025-2026:Supply and fixing for extending the connection from the existing distribution board to the new Inverter /ups distribution board |
| 16 | OD237495/2025-2026:Supply of Distilled lead acid battery water ( 5 litre / bottle) |
| 17 | OD214182/2025-2026:Painting letters or figures of the 2.50 cm, 4 cm or 5 cm height sizes with enamel paint as identification mark to SB, DB, panel board etc as required<br Please Enable Macros to View BoQ information |
AI Tender Summary
Tender Timeline
May 21, 2026
11:30 IST
Tender Published
Tender notice published.
CompletedMay 28, 2026
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedMay 30, 2026
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender