| 1 | Taking out vegetation / water weeds and floating materials from the oxidation ponds of size 124mx46m (approx) and depositing the same to a distance not exceeding 50m over and including Surface dressing on the embankment of oxidation pond not exceeding 15cm deep in soft/ loose soil, by trimming and removing vegetation bushes/ small trees and depositing the same to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5 metres above the starting point, complete all as specified and as directed. |
| 2 | All as per item No 01 here-in-before but Oxidation pond of size 84mX31m (Approx), complete all as specified and as directed. |
| 3 | M&L for opening of blockage of IWC/ EWC/ Urinal by mechanical means for removing blocked wastes/silt and mud, including removal from site and washing down thoroughly for free flowing upto 1st manhole and finally clean the washroom/toilet by clean water to the users satisfaction, complete all as specified and as directed. |
| 4 | M&L for opening of blockage of Gully trap, nahani trap, floor traps in bathroom & kitchen by Mechanical means for removing blocked wastes/silt and mud, including removal from site and washing down thoroughly for free flowing upto 1st manhole and finally celan the kitchen/bathroom and plinth protection around Gully trap by clean water to the users satisfaction, complete all as specified and as directed. |
| 5 | M&L for Cleaning of septic tanks/sewage sumps /blocked manholes etc by blocking temporarily the inlet line with appropriate wooden plugs and bailing/pumping out water in liquid/semi liquid states and scraping out sludge, organic matter/inorganic matter, soft/semi solid material using the mechanical cleaning devices in compliance of section 5 and protective gear and saftey devices in compliance of section 4 of \\"The Prohibition of Employment as Manual Scavengers and their Rehabilitation Act 2013\\" and removing Sludge to a distance n exc 50 mtr away from starting point and depositing in pits not exc 10 sqm on plan and n exc 1.5 m in depth, returning filling in of pit after soaking of water including sprinkling of bleaching powder over the trenches and incl necessary exc and earth work in soft/loose soil , complete all as specified and as directed. |
| 6 | M&L for Cleaning of 100 mm bore sewage line from Manhole to Manhole with mechanical cleaning devices in compliance of section 5 and protective gear and saftey devices in compliance of section 4 of \\"The Prohibition of Employment as Manual Scavengers and their Rehabilitation Act 2013\\" to clear the sludge/blocking etc logged in side the sewage line and well flushing with water to drain the loose sludge etc inside the sewage line from manhole to manhole including removing and re-fixing the manhole cover, complete all as specified and as directed. |
| 7 | M&L for Cleaning of 150 mm bore sewage line from Manhole to Manhole with mechanical cleaning devices in compliance of section 5 and protective gear and saftey devices in compliance of section 4 of \\"The Prohibition of Employment as Manual Scavengers and their Rehabilitation Act 2013\\" to clear the sludge/blocking etc logged in side the sewage line and well flushing with water to drain the loose sludge etc inside the sewage line from manhole to manhole including removing and re-fixing the manhole cover, complete all as specified and as directed. |
| 8 | M&L for Cleaning of 200 mm bore sewage line from Manhole to Manhole with mechanical cleaning devices in compliance of section 5 and protective gear and saftey devices in compliance of section 4 of \\"The Prohibition of Employment as Manual Scavengers and their Rehabilitation Act 2013\\" to clear the sludge/blocking etc logged in side the sewage line and well flushing with water to drain the loose sludge etc inside the sewage line from manhole to manhole including removing and re-fixing the manhole cover, complete all as specified and as directed. |
| 9 | Excavation in trenches not exc 1.5 m in deep and n exc 1.5 m wide for laying of drain pipes, pipe line, fdn for manhole like n exc 10 sqm plan and n exc 1.5 m in depth or as in sooft/loose soil getting out, complete all as specified and as directed. |
| 10 | Returning filling in including spreading, levelling,watering and well ramming in layers not exc 25 mm in soft/loose soil, complete all as specified and as directed. |
| 11 | Removal of surplus soil to a distance n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point, complete all as specified and as directed. |
| 12 | M&L for 150 mm internal dia DWCPE (Double wall corrugated) ISI marked (IS 16098) Non pressure pipe for use in underground drainage and sewarage system single socketed with elastomaric sealing ring joints, laid in trenches and jointed and tested with & Including demoliton of old SGSW/RCC/CI pipe, complete all as specified and as directed |
| 13 | M&L for PCC type C2 (1:3:6) for concrete bed to drain pipes for 150 mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed |
| 14 | M&L for 300 mm internal dia DWCPE (Double wall corrugated) ISI marked (IS 16098) Non pressure pipe for use in underground drainage and sewarage system single socketed with elastomaric sealing ring joints, laid in trenches and jointed and tested with & Including demoliton of old SGSW/RCC/CI pipe, complete all as specified and as directed |
| 15 | M&L for 200 mm internal dia DWCPE (Double wall corrugated) ISI marked (IS 16098) Non pressure pipe for use in underground drainage and sewarage system single socketed with elastomaric sealing ring joints, laid in trenches and jointed and tested with & Including demoliton of old SGSW/RCC/CI pipe, complete all as specified and as directed |
| 16 | M&L for PCC type C2 (1:3:6) for concrete bed to drain pipes for 300 mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested , complete all as specified and as directed |
| 17 | M&L for PCC type C2 (1:3:6) for concrete bed to drain pipes for 200 mm internal dia including packing under, and haunching against the sides of pipes after they are laid and tested, complete all as specified and as directed |
| 18 | M&L for brick work with sub class \\"B\\" bricks straight or curved on plan exceeding 6m mean radius with old size bricks locally available built in cement mortar 1:4 as in Manhole etc complete including demolition of old brick work built in cement mortar, complete all as specified and as directed |
| 19 | M&L for rendering 10 mm thick on fair faces of brick work in CM 1:4 by using water proofing compound as per manufacture instruction by weight of cement finishing the surfaces even and smooth with out using extra cement, complete all as specified and as directed.Note: WPC will be measured and paid under item No 21 here-in-after. |
| 20 | M&L for rendering 15 mm thick on other than fair faces of brick work in CM 1:6 finishing the surface fair and even even and smooth without using extra cement , complete all as specified and as directed. |
| 21 | Supply only integral water proofing compound ISI Marked, complete all as specified and as directed. |
| 22 | M&L for Precast reinforced cement concrete in cover slabs for manhole, Culverts, Septic tank & soak pit slabs and Connected Works type B1 (1:2:4) set in CM 1:4 using 20 mm Graded stone aggregate including necessary form work and demolition of existing RCC of any description and in any position , , complete all as specified and as directed.Note: Reinforcement shall be measured and paid under item No 23 here-in-after. |
| 23 | M&L for TMT bars 5 mm dia and over upto and including 10 mm dia cut to length bent to shape as required incl cranking and binding with and incl MS wire (anealed) not less than 0.90 mm dia as in reinforcement , complete all as specified and as directed. |
| 24 | M&L for PCC type D-2 (1:4:8 ) using 40 mm graded stone aggregate for Foundation and Mass Concrete , complete all as specified and as directed. |
| 25 | M&L for PCC Type B1 (1:2:4) using 20mm graded stone aggregate as in coping & hounching for manhole, complete all as specified and as directed. |
| 26 | M&L for PCC type C-2 1:3:6 (using 40 mm graded stone aggregate) as in surface channels, drains including demolition of old PCC complete all as specified and directed. |
| 27 | M&L for Cement concrete in sunken portion Type E2 (1:5:10) (using 40mm graded aggregate) complete including demolition of PCC in sunken portion (unreinforced) of any description and in any position , complete all as specified and as directed. |
| 28 | S&F in repair's vitreous china squatting pan of orissa pattern size 580 mm x 440mm white back inlet and including provision of PCC ,100mm dia Vitreous china 'P' trap with long arm etc and removal of debris, complete all as specified and as directed. |
| 29 | M&L for Rendering 10mm thick in CM 1:4 using water proofing compound @ 3% by weight of cement finished even and smooth without using extra cement and curved adqutely and after drying apply two coats of epoxy resin of Fosroc or equivalent both on floor and walls of sunken poriton and tested , complete all as specified and as directed.Note: WPC will be measured and paid under item No 21 here-in-before. |
| 30 | S&F in repair's 75 mm dia PVC (SWR) floor traps, plain with grating including jointing with solvent cement, complete all as specified and as directed. |
| 31 | S&F 110 mm dia PVC (SWR) pipes single socketed ,in any length with rubber ring joints, jointed with solvent, fixed to walls etc including taking down old sewage pipes/rainwater pipes with fittings, complete all as specified and as directed. |
| 32 | S&F 75 mm dia PVC (SWR) pipes single socketed ,in any length with rubber ring joints jointed with solvent, fixed to walls etc including taking down old Sewage pipes/rainwater pipes and fittings, complete all as specified and as directed. |
| 33 | S&F 110 mm dia PVC (SWR)junction single (Single T) equal or unequal with access door, complete all as specified and as directed. |
| 34 | S&F 110mm dia PVC (SWR) bends any radius with access door, complete all as specified and as directed. |
| 35 | S&F 110x75mm PVC (SWR) Reducer, Complete all as specified and as directed. |
| 36 | S&F 75 mm dia PVC (SWR) bend with ovel access door, complete all as specified and as directed. |
| 37 | S&F for 75 mm dia PVC (SWR) junction (Single T) equal or unequal with access door complete all as specified and directed. |
| 38 | S&F PVC (SWR) Vent Cowl 75mm dia , complete all as specified and as directed. |
| 39 | M&L for mild steel work such as band, clamps, for rainwater, ventilating pipes, including bolts, if required: hooks (stay), heavy, for large gates; hook and pintle hinges: large hasps and staples; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters; knee piece inserts; two way and three way straps, plate washers and similar small articles, straps, ties etc. and similar works, fabrication for steel sections conforming to Fe-290 (Grade E-165) including necessary welding, bending cold or hot, drilling holes for bolts in any shape or size as indicated, complete all as specified and as directed. |
| 40 | S&F in repair's plastic water closet seat cover, white, with mild steel chromium plated hinging device, complete all as specified and as directed. |
| 41 | S&F 100 mm dia Cast iron soil, waste and vent Spun pipes in any length with or without ears, with cement joints, laid in trenches or in floors etc. including taking down old sewage pipes/rainwater pipes with fittings, complete all as specified and as directed. |
| 42 | S&F 100 mm dia cast iron Bends (any radius), diminishing pieces or tapers (larger bore measured), complete all as specified and as directed. |
| 43 | S&F in repair's PVC valveless syphonic action type Flushing cistern, 10 ltrs capacity with & including PVC Connection 15x450mm long, Flush pipe long/short, & fixing brackets on walls etc., complete all as specified and as directed. |
| 44 | S&F in repair's 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kg/cm2 including all fittnigs fixed to wall or floor with clamps for collecting waste form WHB and sinks, complete all as specified and as directed. |
| 45 | S&F in repair's vitreous china wash down water closet pan (EWC), (Pedestal Pattern) white with & including pvc white color Seat cover fixed with Mild Steel CP hinging device, complete all as specified and as directed. |
| 46 | M&L for Vitreous China urinals, bowl type (back or corner wall type), complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement; fixing automatic flushing cistern with brackets, flush pipe, grating and Union for discharge pipe,urinal spreader fixing with 15 mm pipe min wt 60 gms,32 mm PTMT waste coupling suitable for urinals wt (32-45)gms, complete all as specified and as directed. |
| 47 | S&F in repair's Health Faucet CP brass with 1m long Stainless steel connection pipe and fixed to stop cock/ angle cock, complete all as specified and as directed. |
| 48 | S&F in repair's Grating doom 100 mm dia PTMT with/without waste hole, complete all as specified and as directed. |
| 49 | S&F in repair's 15mm dia stop valve/ angle valve, chromium plated , cast copper alloy, screwed down, high pressure, with capstan head, screwed for iron pipes or brass ferrule, complete all as specified and as directed. |
| 50 | S&F in repair's PVC flush pipe 32mm dia, high density for high or low level flushing cistern, complete all as specified and as directed. |
| 51 | S&F in repair's 32mm dia X 1000mm PVC waste pipe for WHB including PTMT waste coupling, complete all as specified and as directed. |
| 52 | S&F in repair's PVC connection 15x450mm long, complete all as specified and as directed. |
| 53 | S&F in repair's 15mm dia pipe, GI medium grade tubing with all fitting and fixed to wall ceiling or laid in floors , complete all as specified and as directed. |
| 54 | M&L for Non Skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement over and including 15mm thick screed bed or bedding layer in CM 1:6 and dismantling of old floor tiles, rubbish off primeses to match, complete all as specified and as directed. |
| 55 | Refixing of 10 Ltr Capcity PVC flushing cistern after necessary repair work including connection to IWC/EWC and pvc connection, complete all as specified and as directed. |
| 56 | M&L for cutting into existing manholes for connecting new SGSW pipes of dia 100mm, making good to pipe and rendering, cutting out existing benching for the and forming bracnch channel in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required, complete all as specified and as directed. |
| 57 | M&L for cutting into existing manholes for connecting new SGSW pipes of dia 150mm, making good to pipe and rendering, cutting out existing benching for the and forming bracnch channel in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required, complete all as specified and as directed. |
| 58 | M&L for cutting into existing manholes for connecting new SGSW pipes of dia 200mm, making good to pipe and rendering, cutting out existing benching for the and forming bracnch channel in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required, complete all as specified and as directed. |
| 59 | M&L for Collecting and taking out soil/Silt and mud deposited from drains, channels and culvert beds & removing to a distance n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point, complete all as specified and as directed. |
| 60 | M&L for preparation of newly plastered or priviously un-treated wall or concrete surfaces and applying two coats of cement base paint over a coat of Priming plastered with alkali resistant priming paint, complete all as specified and as directed. |
| 61 | Bailing out waste water from septic tank/sludge/chamber/sokage well up to top of sludge/broken media using sewage pump/by manual and disposal of the same to a distance not exceeding 50m away from the starting point and disposing in pits not exceeding 10 sqm on plan and not exceeding 1.5 m in depth,return filling in of pit after soaking of waste water,including sprinkling of bleaching powder over the area of tranches and including necessary excavation and earth work on soft/loose soil, complete all as directed by Engineer-in-charge. |
| 62 | M&L for preperation and make good unserviceable gully trap (0.7 m x 0.57 m ) or available any size, with rendering 10 mm thick plaster in CM(1:4) on fare face of brick work,concrete surfaces finished even and fair without using extra cement and outher necessary materials required,etc., complete all as specified and as directed. |
| 63 | M&L for 100mm thick plain cement concrete (1:4:8) type D2 using 40mm graded stone aggregates as in path, hard standing, complete all as specified and as directed. |
| 64 | M&L for sand cushoning under interlocking tiles, complete all as specified and as directed. |
| 65 | M&L for machine pressed precast concrete interlocking paver blocks of any shape and size confroming to IS15658-2006 of 60mm thickness with grey cement and pigment , complete all as specified and as directed. |
| 66 | M&L for Chequered cement concrete tiles 20cm x 20cm x 25mm thick, set, jointed and pointed in neat cement slurry in floors with grey cement and no pigment over and including Screed Bed or Bedding Layer 15 mm thick in Cement Mortar 1:6 for laying Floor Finishes/Tiles, complete all as specified and as directed |
| 67 | Dismantling of stone slab and tiles of any description or thickness in floors, approns etc. laid bedded and pointed in any mortar, complete all as specified and as directed. |
| 68 | S&F in repair's 32 mm dia waste coupling, brass chromium plated for WHB, etc with long screwed shanks and fly nuts, complete all as specified and as directed. |
| 69 | S&F in repair's 50 mm dia waste coupling, brass chromium plated for kitchen sink, etc with long screwed shanks and fly nuts, complete all as specified and as directed. |
| 70 | M&L for high endura tiles of red or cream colour,10 mm thick set, jointed and pointed in neat cement slurry in floors with grey cement and pigment icluding 15 mm screed bed of CM 1:6, complete all as specified and as directed. |
| 71 | S&F 3 layer 75 mm dia PP-R (Polypropylene random copolymer) concealed pipes SDR 7.4 (PN16) UV stabilized and antimicrobial fusion welded having thermal stability for hot & cold water supply all PP-R plain & brass threaded polypropylene random fittings laid in trenches, complete all as specified and as directed. |
| 72 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required , complete all as specified and as directed. |
| 73 | M&L for Cutting holes n exc 150 sq. cm or through brick walls built in in cement mortar or cement lime mortar and stone walls built in lime mortar or walls of lime concrete and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required and in any position, complete all as specified and as directed. Materials and Labour for rendering 8 mm thick, cement plaster, in cement mortar (1:4) mixed with water proofing compound as per manufactures instructions over and including 12 mm thick backing coat in cement mortar (1:4) on fair faces of brick work or concrete surface in walls, complete all as specified and directed.Note: - (Water proofing compound will be measured and paid separately) Please Enable Macros to View BoQ information |