Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. all kind of soil DSR Code No. 2.8.1 |
| 2 | Excavating, supplying, stacking and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in foundation trenches, plinth, sides of foundation etc. complete for all lift. DSR Code No. 2.25(a) |
| 3 | Earth filling under floors and/or sub station area including cost of earth when obtained from with in 8 km outside UPPCL area including its roylty and carriage, loading/ unloading, spreading , watering, ramming in 20 cm layers and dressing of earth etc. for proper completion of the work. SOR-2023 CSI No. 4.10 |
| 4 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. DSR Code No. 2.27 |
| 5 | Clearing jungle including uprooting of rank vegetation, grass, brush wood, trees and saplings of girth up to 30 cm measured at a height of 1 m above ground level and removal of rubbish up to a distance of 50 m outside the periphery of the area cleared. DSR Code No. 2.31 |
| 6 | Clearing grass and removal of the rubbish up to a distance of 50 m outside the periphery of the area cleared. DSR Code No. 2.32 |
| 7 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources). DSR Code No. 4.1.10 |
| 8 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1½:3 (1 Cement:1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR Code No. 4.1.2 |
| 9 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources). DSR Code No. 4.1.3 |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form work for :Foundations, footings, bases for columns DSR Code No. 4.3.1 |
| 11 | Centering and shuttering including strutting, propping etc. and removal of form work for :Retaining walls, return walls, walls (any thickness) including attached pilasters, buttresses, plinth and string courses fillets, kerbs and steps etc. DSR Code No. 4.3.2 |
| 12 | Centering and shuttering including strutting, propping etc. and removal of form work for : Columns, piers, abutments, pillars, posts and struts. DSR Code No. 4.3.3 |
| 13 | Providing and fixing up to floor five level precast cement concrete string or lacing courses, copings, bed plates, anchor blocks, plain window sills, shelves, louvers, steps, stair cases, etc., including hoisting and setting in position with cement mortar 1:3 (1 Cement : 3 coarse sand), cost of required Centering complete. 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20mm nominal size derived from natural sources) DSR Code No. 4.5.1 |
| 14 | Providing and laying damp-proof course 40mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 12.5mm nominal size derived from natural sources). DSR Code No. 4.10 |
| 15 | Extra for providing and mixing water proofing material in cement concrete work in doses by weight of cement as per manufacturer's specification. DSR Code No. 4.12 |
| 16 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) DSR Code No. 5.1.2 |
| 17 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). DSR Code No. 5.3 |
| 18 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.1) Foundations, footings, bases of columns, etc. for mass concrete DSR Code No. 5.9.1 |
| 19 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.2) Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc. DSR Code No. 5.9.2 |
| 20 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.3) Suspended floors, roofs, landings, balconies and access platform. DSR Code No. 5.9.3 |
| 21 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.4) Shelves (Cast in situ). DSR Code No. 5.9.4 |
| 22 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.5) Lintels, beams, plinth beams, girders, bressumers and cantilevers. DSR Code No. 5.9.5 |
| 23 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.6) Columns, Pillars, Piers, Abutments, Posts and Struts. DSR Code No. 5.9.6 |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.16.2) Edges of slabs and breaks in floors and walls. Above 20 cm wide DSR Code No. 5.9.16.2 |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.18) Small surfaces such as cantilever ends, brackets and ends of steps, caps and bases to pilasters and columns and the like. DSR Code No. 5.9.18 |
| 26 | Centering and shuttering including strutting, propping etc. and removal of form for. (5.9.21) Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. DSR Code No. 5.9.21 |
| 27 | Concrete work with 40 mm gauge I class brick ballast coarse sand and cement in proportion of 12:6:1 in foundations and under floors, including cost of all labour, materials, T&P etc required for proper completion of work. SOR-2023 No. 5.01 |
| 28 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron 'Y' shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) DSR Code No. 16.53 |
| 29 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more.. DSR Code No. 5.22.6 |
| 30 | Smooth finishing of the exposed surface of R.C.C. work with 6 mm thick cement mortar 1:3 (1 Cement : 3 fine sand). DSR Code No. 5.23 |
| 31 | Add for plaster drip course/ groove in plastered surface or moulding to R.C.C. projections.DSR Code No. 5.30 |
| 32 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (6.1.1) Cement mortar 1:4 (1 cement : 4 coarse sand) DSR Code No. 6.1.1 |
| 33 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: (6.1.2) Cement mortar 1:6 (1 cement : 6 coarse sand). DSR Code No. 6.1.2 |
| 34 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (6.4.1) Cement mortar 1:4 (1 cement : 4 coarse sand). DSR Code No. 6.4.1 |
| 35 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in : (6.4.2) Cement mortar 1:6 (1 cement : 6 coarse sand) DSR Code No. 6.4.2 |
| 36 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations and plinth in: cement mortar 1:4 (1 cement : 4 coarse sand) DSR Code No. 6.12.2 |
| 37 | Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level. DSR Code No. 6.13.2 |
| 38 | Brick work in foundation & plinth with old dismantled bricks (supplied by department free of cost) and coarse sand mortar in 1:6 including supply of all other materials, labour, removing mortar & cleaning of old & used bricks,T&P etc complete. (NSI), Ref. CSI No. (6.18 ) SOR 23-24 |
| 39 | Same as in item 6.18 above but in super structure for 230 mm thick wall. (NSI), Ref. CSI No. (6.19) SOR 23-24 |
| 40 | Structural steel work riveted,bolted or welded in built up section,trusses and framed work , including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. DSR Code No. 10.2 |
| 41 | Providing and fixing in position collapsible steel shutters with vertical channels 20x10x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. DSR Code 10.3 |
| 42 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.). DSR Code No. 10.18 |
| 43 | Supply and fixing of 32 mm thick single leaf flush door shutter ( boiled water resistance, phenol maldehide resin bonded, hot pressed factory made) commercial quality to I.S.2202 part-1 (1983) ISI marked including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges,bolts.locks,handles, springs and other fittings but excluding their supply including all materials, labour & T&P etc. required for proper completion of work. (NSI), Ref. CSI No. (8.54) SOR 23-24 |
| 44 | Supply and fixing of 40 mm thick single leaf flush door shutter ( boiled water resistance, phenol maldehide resin bonded, hot pressed factory made) commercial quality to I.S.2202 part-1 (1983) ISI marked including fixing of wooden cleats and stoppers and including fixing and adjustment of hinges,bolts.locks,handles, springs and other fittings but excluding their supply including all materials, labour & T&P etc. required for proper completion of work. (NSI), Ref. CSI No. (8.55) SOR 23-24 |
| 45 | Providing & fixing fly proof wire gauze to windows, clerestory windows & doors with M.S. Flat 15x3 mm and nuts & bolts complete. Stainless steel (grade 304) wire gauze of 0.5 mm dia wire and 1.4 mm aperture on both sides. DSR Code No. 10.29.2 |
| 46 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : (10.30.1) 4.0 mm thick glass panes. DSR Code No. 10.30.1 |
| 47 | Brick on edge flooring with bricks of class designation 7.5 on a bed of 12 mm cement mortar, including filling the joints with same mortar, with common burnt clay non modular bricks: 1:4 (1 cement : 4 coarse sand). DSR Code No. 11.1.1 |
| 48 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. (11.3.1) 40 mm thick with 20 mm nominal size stone aggregate DSR Code No. 11.3.1 |
| 49 | Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete. DSR Code No. 11.27 |
| 50 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. DSR Code No. 11.37 |
| 51 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to IS : 15622 (thickness to be specified by the manufacturer ) of approved make in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge in skirting, risers of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm including pointing in white cement mixed with pigment of matching shade complete. DSR Code No. 11.37 A |
| 52 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS: 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/ sqm including grouting the joints with white cement and matching pigments etc., complete Size of Tile 600x600 mm. DSR Code No. 11.41.2 |
| 53 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. DSR Code No. 12.50 |
| 54 | 12 mm cement plaster of mix : (13.4.1) 1:4 (1 cement: 4 coarse sand) DSR Code No. 13.4.1 |
| 55 | 12 mm cement plaster of mix : (13.4.2) 1:6 (1 cement: 6 coarse sand) DSR Code No. 13.4.2 |
| 56 | 20 mm cement plaster of mix 1:6 (1 cement: 6 coarse sand) DSR Code No. 13.6.2 |
| 57 | Rough cast plaster upto 10 m height above ground level with a mixture of sand and gravel or crushed stone from 6 mm to 10 mm nominal size, dashed over and including the fresh plaster in two layers, under layer 12 mm cement plaster 1:4 (1 cement : 4 coarse sand) and top layer 10 mm cement plaster 1:3 (1 cement : 3 fine sand) mixed with 10% finely grounded hydrated lime by volume of cement.Ordinary cement finish using ordinary cement DSR Code No. 13.19.1 |
| 58 | Extra for providing and mixing water proofing material in cement plaster work in proportion recommended by the manufacturers. DSR Code No. 13.21 |
| 59 | Neat cement punning. DSR Code No. 13.18 |
| 60 | Providing and applying plaster of paris putty of 2 mm thickness over plastered surface to prepare the surface even and smooth complete. DSR Code 13.26 |
| 61 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC content less than 50 gram/litre, of approved manufacturer and of required shade and colour all complete to achieve even shade and colour : (13.41.1) New work (two or more coats) over and including water thinnable priming coat with cement primer having VOC content less than 50 gram/litre. DSR Code No. 13.41.1 |
| 62 | Distempering with 1st quality acrylic distemper (ready mixed) having VOC (Volatile Organic Compound ) content less than 50 gram/ litre, of approved brand and manufacturer including applying additional coats wherever required to achieve even shade and colour. Old work (one or more coats) DSR Code 13.81.1 |
| 63 | Finishing walls with Acrylic Smooth exterior paint of required shade : New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) DSR Code No. 13.46.1 |
| 64 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :(13.62.1) Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. DSR Code No. 13.62.1 |
| 65 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. DSR Code No. 13.80 |
| 66 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. One coat DSR Code 13.82.1 |
| 67 | Wall painting with acrylic emulsion paint, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour. Two coat DSR Code 13.82.2 |
| 68 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre. DSR Code No. 13.85.3 |
| 69 | Finishing walls with Acrylic Smooth exterior paint of required shade :Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface. DSR Code No. 13.111.1 |
| 70 | Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge. (15.2.1) Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix). DSR Code No. 15.2.1 |
| 71 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. DSR Code No. 15.3 |
| 72 | Demolishing brick work manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge. (15.7.1) In Cement mortar. DSR Code No. 15.7.4 |
| 73 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.DSR Code No. 15.56 |
| 74 | Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved. DSR Code No. 15.60 |
| 75 | Pre-Construction anti-termite treatment, by creating a barrier under and around the columns pits, foundation trenches, under floors, junctions of Walls & floors, around the external perimetre of building, expansion joints, surrounding of pipes and conduits etc. (Plinth area of the building at ground floor only shall be measured as per I.S. 6313 (Part II 1981))with Eldrine emulsifiable 0.2% concentration or any other approved material such as Heptachlore or chlordance will be used. The consumption of emulsion shall be (i) Foundation and masonary @ 5 Ltrs/Sqm, (ii) Back fills in immediate contact of foundation@ 7.5 Ltrs. / Sqm, (iii) Top surface of Plinth filling @ 5 Ltrs / Sqm, ( iv) Junction of walls & floors @ 7.5 Ltrs / Sqm, (v) Soil along external perimetre of building @ 7.5 Ltrs / Sqm (vi) under apron of the building @ 5 Ltrs. /Sqm. The rates includes cost of all materials, labour, equipments, T&P complete. SOR -2023 CSI 17.01 |
| 76 | Providing and laying design mix cement concrete of M-30 grade, in roads/ taxi tracks/ runways, using cement content as per design mix, using coarse sand and graded stone aggregate of 40 mm nominal size in appropriate proportions as per approved & specified design criteria, providing dowel bars with sleeve/ tie bars wherever required, laying at site, spreading and compacting mechanically by using needle and surface vibrators, levelling to required slope/ camber, finishing with required texture, including steel form work with sturdy M.S. channel sections, curing, making provision for contraction/ expansion, construction & longitudinal joints (10 mm wide x 50 mm deep) by groove cutting machine, providing and filling joints with approved joint filler and sealants, complete all as per direction of Engineer-in-charge (Item of joint fillers, sealants, dowel bars with sleeve/ tie bars to be paid separately).Cement concrete prepared with batch mixing machine DSR Code No. 16.43.1 |
| 77 | Extra for providing and mixing hardening compound of approved quality as per manufacturer's specification in cement concrete. DSR Code No. 16.44 |
| 78 | Providing and fixing pre-moulded joint filler in expansion joints of RCC roads / CC pavements after making the joints dust free with high pressure air jet cleaners, all complete as per direction of the Engineer-in-Charge. (Pre-moulded joint fillers shall be made of bitumen hot sealing compound impregnated fibre board having impregnation more than 35%, conforming to IS:1838 for fibre board and IS: 1834 for hot sealing bitumen compound grade A.). DSR Code No. 16.45 |
| 79 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge.80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. DSR Code No. 16.91.2 |
| 80 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: (17.1.1) White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests. DSR Code No. 17.1.1 |
| 81 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required : (17.2.1) W.C. pan with ISI marked white solid plastic seat and lid. DSR Code No. 17.2.1 |
| 82 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350 mm and 340x410x265 mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required : (17.4.1) One urinal basin with 5 litre white P.V.C. automatic flushing cistern. DSR Code No. 17.4.1 |
| 83 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require: (17.7.4) White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap. DSR Code No. 17.7.4 |
| 84 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception of pipes and fittings. DSR Code No. 17.8 |
| 85 | Providing and fixing P.V.C. low level flushing cistern with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete. 10 litre capacity - White DSR Code 17.18.1 |
| 86 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete. (17.28.1) Semi rigid pipe (17.28.1.1) 32 mm dia DSR Code No. 17.28.1.1 |
| 87 | Providing and fixing 100 mm sand cast Iron grating for gully trap. DSR Code No. 17.29 |
| 88 | Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. DSR Code No. 17.31 |
| 89 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. (17.73.1) 450 mm long towel rail with total length of 495 mm, 78 mm wide and effective height of 88 mm, weighing not less than 170 gms DSR Code No. 17.73.1 |
| 90 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (18.8.1) 15 mm nominal dia Pipes DSR Code No. 18.8.1 |
| 91 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (18.8.3) 25 mm nominal dia Pipes DSR Code No. 18.8.3 |
| 92 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. (18.8.4) 32 mm nominal dia Pipes DSR Code No. 18.8.4 |
| 93 | Providing and fixing brass bib cock of approved quality : (18.15.1) 15 mm dia nominal bore DSR Code No. 18.15.1 |
| 94 | Providing and fixing brass stop cock of approved quality : (18.16.1) 15 mm dia nominal bore DSR Code No. 18.16.1 |
| 95 | Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete : (18.18.3) 25 mm dia nominal bore DSR Code No. 18.18.3 |
| 96 | Providing and fixing gun metal non- return valve of approved quality (screwed end) : (18.19.1) 25 mm nominal bore (18.19.1.1) Horizontal. DSR Code No. 18.19.1.1 |
| 97 | Providing and fixing uplasticised PVC connection pipe with brass unions : (18.21.1) 30 cm length (18.21.1.1) 15 mm nominal bore DSR Code No. 18.21.1.1 |
| 98 | Providing and fixing uplasticised PVC connection pipe with brass unions : (18.21.1) 30 cm length (18.21.1.2) 20 mm nominal bore DSR Code No. 18.21.1.2 |
| 99 | Providing and fixing uplasticised PVC connection pipe with brass unions : (18.21.2) 45 cm length (18.21.2.1) 15 mm nominal bore DSR Code No. 18.21.2.1 |
| 100 | Providing and fixing uplasticised PVC connection pipe with brass unions : (18.21.2) 45 cm length (18.21.2.2) 20 mm nominal bore DSR Code No. 18.21.2.2 |
| 101 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank, IS : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. DSR Code No. 18.48 |
| 102 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. (18.50.1) 15 mm nominal bore DSR Code No. 18.50.1 |
| 103 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS:8931. (18.53.1) 15 mm nominal bore DSR Code No. 18.53.1 |
| 104 | Providing and fixing double action hydraulic floor spring of approved brand and manufacture conforming to IS : 6315, having brand logo embossed on the body / plate with double spring mechanism and door weight upto 125 kg, for doors, including cost of cutting floors, embedding in floors as required and making good the same matching to the existing floor finishing and cover plates with brass pivot and single piece M.S. sheet outer box with slide plate etc. complete as per the direction of Engineer-in-charge. With stainless steel cover plate minimum 1.25 mm thickness. DSR Code 21.4.1 |
| 105 | S/Fixing of single action floor springs including cutting in floors / RCC slabs and grouting the same with C.C. & finishing the surface properly as and where required under aluminium doors as per direction of Engineer-in-charge. including cost of all other material, labour, tools & plants etc. complete. CSI No. 8.53 (SOR 23-24) |
| 106 | Supply and fixing brass polished hydraulic door closure of approved make & quality its fixing and adjustment with the help of screws, nuts and bolts including supply of all labour, T & P etc. required for proper completion of the work. Ref CSI No. 8.57 (SOR 23-24) |
| 107 | Supply & installation of electrical control panel of L&T / Havells or equivalent make for submersible pump / pumpset containing contractor relay condenser. b) for 1.5/ 2 H.P pump set single phase. CSI No. 19.31(b) (SOR 23-24) |
| 108 | Supply & Installation of submersible pump of K.S.B/ CALAMA. or eqt. make including cost of labour, T&P and material required for completion of work. b) 1.5 HP outlet 40mm dia. or more, Head 71/36, Discharge 2000/6000 LPH NSI Ref. 19.32 (b)(SOR 23-24) |
| 109 | S/laying chicken mesh of (20 mm.)hexagonal heavy quality over roofs of joints of roof as per direction of the Engineer - in - charge. Ref. CSI No. 20.21 |
| 110 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a) Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment.(b) Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand ) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. (c) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge.(d) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.(e) The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test.“All above operations to be done in order and as directed and specified by the Engineer-in-Charge : With average thickness of 120 mm and minimum thickness at khurra as 65 mm. DSR Code No. 22.7.1 |
| 111 | S/F high Tensile steel colour coated anti rust ,high temp resistant sheet with Tensile Strength 550 MPA hot dip metallic (zinc Aluminum Alloy (Zn-55%)(Al-45% ) Coating 70GSM with total thikness not less than 0.50mm (TCT) Durashine make with necessary over laps including S/F Galvanized J/V Hook according to purlin with ,nut,washer and bitumen washers etc.including cost of material ,labour T&P etc and special fastener (HT) , nuts & washer provide dia by the company etc required for proper completion of work as per direction of E/I confirming 1.5. 1397:1993. Ref. CSI No. (26.60) SOR 20-21 |
| 112 | Supply and Fixing of 5 blade Exhaust fan ventile air dx 225 mm of Havells or equivalent make including all material, T&P etc required for proper completion of work as approved by engineer in charge. NSI. (28.38) |
| 113 | Supply and fixing of LED Tube Light with batten suitable for up to 1 X 22 watt LED tube light fitting including tube on Surface complete in all respect. CAT- AA (Ref. UPPWD SOR ELECTRICAL 2018 Item No 1413) |
| 114 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required..Group C E&M -1.10.3 |
| 115 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 6 sq. mm + 1 X 6 sq. mm earth wire. E&M-1.14.4 |
| 116 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 2 X 4 sq. mm + 1 X 4 sq. mm earth wire. E&M-1.14.3 |
| 117 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \\"C\\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. E&M 2.10.1 |
| 118 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 3 pin 5/6 amp socket outlet. E&M -1.24.4 |
| 119 | Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps E&M 2.12.2 |
| 120 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door. E&M -2.4.1 |
| 121 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. E&M- 1.12 |
| 122 | 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min , 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC supply Earthing etc (DSR 19.1 (E&M 2022) |
| 123 | Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as p. DSR 10.18 |
| 124 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 1 or 2 Module (75mmX75mm). E&M-1.27.1 |
| 125 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 3 Module (100mmX75mm). E&M-1.27.2 |
| 126 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 4 Module (125mmX75mm). E&M-1.27.3 |
| 127 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc as required. 6 Module (200mmX75mm). E&M-1.27.4 |
| 128 | Boring in 4\\" dia casing pipe up to a profeble depth of 50 m from ground lable with skilled and unskilled labour and T&P boring apparatus super vision charge etc. requierd for proper completion of the work. From 6m to 50 m Depth. SOR-2023 CSI NO 20.23b |
| 129 | Transportation and installation of tube well drilling Rig m/c, compressure for development and other required equipments and accessories at site of work and dismentlling & taking them back after successful completion of the work including cleaning, levelling - dressing the site properly, also disposing off the surplus earth, silt, sand etc: SOR-2023 CSI no 19.28 |
| 130 | Supply & fixing of steel wire rope for submersible pump including cost of labour, T&P and material required for completion of work. NSI 19.34 |
| 131 | Supply & fixing of Submersible Cable Havel or equivelent make for Submersible pump Complete in all respect 2.5 Sqm for pump above 1 hp and up to 3 H.P. SOR-2023 CSI no 19.33 (b) |
| 132 | Providing and laying 75mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. NSI no 27.29 (A) |
| 133 | Providing and laying 90mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. NSI no 27.29 (B) |
| 134 | Providing and laying 110mm dia SWR, PVC ( Finolex or equivalent ) pipe including cost of excavation, C.C etc including its jointing and connection, all materials, labour and T&P etc. required for proper completion of the work. NSI no 27.29 (C) |
| 135 | Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/ medium/ coarse, in required grading & sizes as per actual requirement, all complete as per direction of Engineer-in-charge.DSR code no 23.8 |
| 136 | Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge.100 mm nominal size dia DSR code no 23.3.1 |
| 137 | Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge.100 mm nominal size dia DSR code no 23.4.1 |
| 138 | Providing and fixing Bail plug/ Bottom plug of required dia to the bottom of pipe assembly of tubewell as per IS:2800 (part I)..100 mm dia DSR code no 23.15.1 |
| 139 | Development of tube well in accordance with IS : 2800 (part I) and IS: 11189, to establish maximum rate of usable water yield without sand content (beyond permissible limit), with required capacity air compressor, running the compressor for required time till well is fully developed, measuring yield of well by \\"V\\" notch method or any other approved method, measuring static level & draw down etc. by step draw down method, collecting water samples & getting tested in approved laboratory, i/c disinfection of tubewell, all complete, including hire & labour charges of air compressor, tools & accessories etc., all as per requirement and direction of Engineer-in-charge. DSR code no 23.12 |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail