| Sl. No. | Item Description |
| 1 | Price Schedule SectionF1-1 |
| 2 | Price Section F1-2 |
| 3 | Price Section F1-3 |
| 4 | Price Section F1-6 PREAMBLE TO SCHEDULE OF PRICE |
| 5 | The prices entered in the following schedule are to include everything necessary, together with all general risks, liability and obligations set forth or implied in the Contract Documents, to deliver the Works complete and in full working order at the expiry of the Defect Liability Period (DLP) in accordance with the provisions of the Contract and tender documents. |
| 6 | The Schedule of Price shall be read together with the Instructions to Bidders, Conditions of Contract, Specifications and Drawings in accordance with the provisions of the Contract and tender documents. |
| 7 | The specified spare parts shall be stored at site by Contractor and shall be issued to the Employer at the time of taking over of the Works. |
| 8 | For works price quoted by the bidder shall consist of labour cess. GST will be applicable to the quoted price. The rates and prices quoted by the Bidder are not subject to adjustment during the performance of the Contract except for the specific provisions given in General/Particular Conditions of Contract.All duties, taxes, cess, transportation, insurance and other levies (it should be specific) payable by the contractor as per State / Central Government rules, shall be included in the bid price quoted by the Bidder. Employer will not bear any liability on account of any taxes/duties/cess/insurance/transportation and other levies applicable on the supply and services/works. Employer shall however deduct taxes at source as per the rules and issue necessary certificate to the contractor.All prices to be quoted in INR. |
| 9 | The schedule of price is the scope of work of Contractor, which includes the Design, manufacture, procurement, supply, fabrication, shop assembly, painting, shop testing, transportation, insurance & delivery to project site, receipt & storage at site, erection, testing & commissioning including packing & forwarding for shipment and trial operation, as built drawings and instruction manuals of Goods as detailed in Technical Specifications or elsewhere. The equipment / systems / Services to be furnished shall consist of mainly, but not be limited to the BOQ/scope of work. All accessories, fittings, indicating,signalling instruments, etc. are to be supplied and installed, though all of them may not be detailed explicitly in the description . SECTION F1 - 1 ABSTRACT OF SCHEDULE PRICE SCHEDULE :Design, manufacture, procurement, supply, fabrication, shop assembly, painting, shop testing, transportation, insurance & delivery to project site, including packing & forwarding for shipment NAME OF TENDERER Bid No Sl.No Description Quantity Unit Price of Each quantity Total Price GST Total Price (all price schedule) with GST |
| 10 | Turbine & its Accessories A Horizontal Axis Francis turbine (428.6 RPM) and accessories comprising of Runner, ajustable guide Vanes, turbine Shaft, indicating and recording instruments, Control & Safety Devices, Brake & Jack System, Lube Oil System, piping etc., complete with its associated Spiral Casing & other accessories, including embedded and foundation parts, Instruments, complete in all respects to develop rated output of 8.0 MW at rated net head and capable of delivering a continuous output of 110% of rated output at rated net head & discharge at Generator terminal and consisting of the following.(As per technical Specification) 3.0 sets 0.0 0.0 i Draft Tube, Draft Tube Cone, Elbow, Spiral Casing, Stay rings and other embedded and foundation parts with foundations bolts and embedded pipes, etc. 3.0 sets ii Guide apparatus complete with Side Cover, bottom ring with guide vane bearings, guide vanes, levers, links, operating mechanism, servomotors, bearings, bushes etc., 3.0 sets iii Draft Tube, supports, anchor bars, embedded and exposed piping complete with fitting, flanges, valves, bolts, nuts etc. 3.0 sets iv Rotating assembly complete with shaft, runner, shafts seals, Bearing assembly, complete with bearing elements aligning mechanism, end cover etc., 3.0 Sets v Speed sensing gear, Mechanical over speed switch & feedback transducer assembly 3.0 sets B Digital electronic governor and governing equipment complete in all respects for optimizing and controlling the turbines. (As per technical Specification) 3.0 sets 0.0 0.0 C Common Pressure Oil system (OPU) complete with pumps, motors, valves, nitrogen-based oil pressure accumulators, piping, associated electrical system etc., for actuating guide vanes for Governor and Butterfly Valve.(As per technical Specification) 3.0 sets 0.0 0.0 D Cooling water system complete with main and standby pumps sets, motors, valves, piping, necessary cabling, motors starters, alarms & safety devices etc., (As per technical Specification) 3.0 sets 0.0 0.0 E Station drainage & de-watering system complete with main and stand by Vertical turbine / submersible pump sets, motors, valves, piping, necessary cabling, motor starters etc (As per technical Specification) 1.0 set 0.0 0.0 F Compressed Air System (As per technical Specification) 1.0 Set 0.0 0.0 G Mechanical Workshop :Machine tools, hand tools, measuring devices, Testing devices, and accessories etc.(As per technical Specification) 1.0 Lot 0.0 0.0 H Bed plates, base frames, foundation bolts etc., for all equipment (As per technical Specification) 3.0 sets 0.0 0.0 I Instrumentation, control and safety devices such as pressure gauges, flow indicators, runner blade /guide vanes position indicators, limit switches, gates position indicator, for complete instrumentation, including transducers, recorders, annunciators, control and safety of the goods, field Instruments and Receiving Instruments ,complete monitoring and Safety Instruments pertaining to the TG set.(As per technical Specification) 3.0 sets 0.0 0.0 |
| 11 | GENERATOR & EXCITATION SYSTEM A Horizontal Axis synchronous generator of 3 phase 11 kV, 50 Hz, 0.85 p.f lag, 8.0 MW with 10% continuous inherent overload capacity, Class F insulation with temperature rise as stipulated in specification and designed to withstand runaway speed for 15 minutes (without water supply to bearing), coupled directly to the turbine complete in all respects and consisting of followings:(As per technical Specification) 3.0 sets 0.0 0.0 i Stator complete with frame, punching and windings 3.0 sets ii Rotor complete with shaft, spider rim, poles with winding, rotor fan for cooling and accessories and pedestal bearings. 3.0 sets iii Static Excitation system and Digital voltage regulation equipment (AVR panels) 3.0 sets B Control Panels & Annunciation Panel a LAVT panel (11 kV) Consisting of following: (As per technical Specification) 9.0 sets 0.0 0.0 i Single Phase, Two Core, PT for metering, synchronising and protection 9.0 Nos ii Single Phase, Single Core, PT for AVR and Voltage Balance Relay Circuit 9.0 Nos iii 10 kV, 10 kA, Single Phase Lightning Arrester (LA) for Lightning Protection and capacitance for surge protection 9.0 Nos iv Current Transformer (CT) Single Phase, 600/5A, 3 core for protection 9.0 Nos v Current Transformer (CT) Single Phase, 50/1A, 3 core for protection 9.0 Nos b Generator neutral grounding transformer cubicle with 600/5A and 5 core CT’s(As per technical Specification) 3.0 sets 0.0 0.0 c Generating Unit & its auxiliaries control panel (UCB)(As per technical Specification) 3.0 Sets 0.0 0.0 d Generator Relay, metering Protection Panel(As per technical Specification) 3.0 sets 0.0 0.0 |
| 12 | Auxiliary Transformers i Station service Transformer, ONAN type, 800kVA, 33/0.415kV, 50 Hz with all accessories(As per technical Specification) 1.0 No 0.0 0.0 ii Transformer for Barrage, ONAN type, 250 kVA, 33/0.415 kV, 50 Hz with all accessories(As per technical Specification) 1.0 No 0.0 0.0 iii Transformer for Colony, ONAN type, 500 kVA, 33/0.415 kV, 50 Hz with all accessories (As per technical Specification) 1.0 No 0.0 0.0 iv Unit Auxiliary Transformer, Dry Type, 3 phase,250 kVA, 11 kV/0.415 kV, 50 Hz with all accessories. 3.0 No 0.0 0.0 |
| 13 | Medium Voltage Switchgear i 33 KV Switchgear with incoming and outgoing breakers complete with bus bar chamber, supports, wiring terminals, blocks, fuses, labels, interlocks & metering as specified(As per technical Specification) 1.0 set 0.0 0.0 |
| 14 | 415V Low Voltage Switchgear i 415 V Station Service Board with LT breaker, and outgoing MCCB’s complete with bus bar chamber, supports, small wiring terminals, blocks, fuses, labels, interlocks & metering as specified(As per technical Specification) 1.0 No 0.0 0.0 ii 415 V Unit Auxiliary Board with LT breaker, and outgoing MCCB’s complete with bus bar chamber, supports, small wiring terminals, blocks, fuses, labels, interlocks & metering as specified(As per technical Specification) 3.0 Nos 0.0 0.0 |
| 15 | Control & Protection System i Protection System comprising of Numerical relays and metering for Generator Units, Generator Transformers, Switchyard and transmission lines etc (As per technical Specification) 1.0 Lot 0.0 0.0 |
| 16 | Control & Monitoring System(SCADA) i Supervisory Control and Data Acquisition System (SCADA) with engineering operator work stations in control room, UPS for SCADA for complete power system control for 3 units (As per technical Specification) 1.0 lot 0.0 0.0 |
| 17 | DC SYSTEM i 220 VDC, 400 AH, VRLA type Battery along with battery charger and DC distribution boards (As per technical Specification) 1.0 Lot 0.0 0.0 |
| 18 | Power & Control cables and cable trays i Control, Instrumentation and power cables of various rating and sizes and 11kV and 33kV power cables including 11 KV unearthed XLPE cable for connection between generator and other equipment and cable trays and accessories for complete works (As per technical Specification) 1.0 Lot 0.0 0.0 |
| 19 | Illumination System i Power House / Switchyard, Barrage, Intake area and outdoor area illumination and Emergency Lighting (DC supply)(As per technical Specification) 1.0 Lot 0.0 0.0 |
| 20 | Earthing System i Earthing system with MS rods, bolts, nuts, washer, earth electrodes etc. (for power house, switchyard, Barrage, intake area etc.)(As per technical Specification) 1.0 Lot 0.0 0.0 |
| 21 | Emergency Diesel Generator Sets i 250kVA DG set with AMF panel and all other accessories and Acoustic enclosure (As per technical Specification) 1.0 Set 0.0 0.0 |
| 22 | Communication System i Plant Communication System (VoIP) and Public Address System, CCTV & Surveillance System including UPS for Powerhouse, Barrage and Switchyard(As per technical Specificatin) 1.0 Lot 0.0 0.0 |
| 23 | 33 KV SWITCHYARD A 33 kV Switchyard equipment for generating end & receiving end switchyard (Complete with the supporting Structures & Accessories) consisting of following: (As per technical Specification) 1.0 Lot 0.0 0.0 i 33 kV, 1250 A, 25 KA triple pole, VCB, complete with operating mechanism, terminal connector and mounting structures & marshalling box. 6.0 Nos ii 33 kV, 1250 A, 25 KA triple pole, horizontal double break, hand operated isolators (with earthing switch) complete with operating mechanism, terminal connector and mounting structures & marshalling box. 2.0 Nos. iii 33 kV, 1250 A, 25 KA triple pole, horizontal double break, hand operated isolators (without earthing switch) complete with operating mechanism, terminal connector and mounting structures & marshalling box. 7.0 Nos iv 33 kV, 200/1 ratio, Single Phase, 50 Hz, 4 Core, current transformers complete with terminal connector, junction boxes & mounting Structure. 12.0 Nos v 33 kV, 600/1 ratio, Single Phase, 50 Hz, 5 Core, current transformers complete with terminal connector, junction boxes & mounting Structure 6.0 Nos vi 33kV single phase, three Core (33kV/Sqrt3)/(110V/Sqrt3)/(110V/ Sqrt3)/(110V) Electromagnetic voltage transformers (for Bus) suitable for star/ Star/ Delta connections complete with protection Fuses, terminal connectors, junction boxes, mounting structure etc. 6.0 Nos vii 33kV single phase, three core (33kV/ Sqrt3)/(110V/Sqrt3)/(110V/ Sqrt3)/(110V)Electromagnetic voltage transformers (for line) suitable for star/ Star/ delta connections complete with protection Fuses, terminal connectors, junction boxes, mounting structure etc 6.0 Nos viii Single phase, 30 kV, 10 KA nominal discharge current non-linear metal-oxide surge arresters complete with insulating base, surge counters, Structure) leakage current indicators, terminals connector, mounting structure 18.0 Nos. ix 33 kV post insulators complete in the terminal connector & mounting structure 1.0 Lot x 33 kV Porcelain Insulator Strings complete with fittings 1.0 Lot xi Conductors, Ground wire, tubular bus, clamps and connectors 1.0 Lot xii Gantry structure in switchyard. 1.0 Lot |
| 24 | 33kV Overhead line from Powerhouse to Barrage (~ 3km)(As per technical Specification) |
| 25 | Electrical Workshop i Machine tools, hand tools, measuring devices, testing devices, and accessories etc.(As per technical Specification) 1.0 Lot 0.0 0.0 |
| 26 | 45/10T EOT Crane pendant operated with all controls(As per technical Specification) |
| 27 | Main Inlet Butterfly valve (2000 mm diameter)(As per technical Specification) |
| 28 | Fire Fighting System i Firefighting system comprising fire stations with rack/reels, hoses, nozzles, fire alarm system with panels, pumps, valves, pipings, portable fire extinguishers, water filled/sand filled buckets etc. mandatory as per TAC complete for power house.(As per technical Specification) 1.0 Lot 0.0 0.0 |
| 29 | Heating, Ventilation & Air-Conditioning (HVAC) SystemSpilt type Air conditioning equipment for Powerhouse and Barrage control room, Office and Conference Room, Ventilation equipment for power house(As per technical Specification) TOTAL AMOUNT 0.0 NOTE: A) In case of discrepancy between unit price and total price, the unit price shall prevail. B) The TENDERER shall include in the most appropriate item the price of any equipment or piece of equipment required for the proper operation and maintenance of goods listed in Schedule of Requirements and described in Technical Specifications. C) The currency shall Indian Rupees only. D)The currency shall Indian Rupees only. GST is applicable to the quoted price.All duties, taxes, cess, transportation, insurance and other levies (it should be specific) payable by the contractor as per State / Central Government rules and shall be included in the bid price i.e price of each quantity quoted by the Bidder. Employer will not bear any liability on account of any duties/taxes/cess /transportation, insurance and other levies applicable on the supply and works. Employer shall however deduct taxes at source as per the rules and issue the necessary certificate to the contractor SECTION F1 - 2 PRICE BREAK-UP FOR MANDATORY SPARES FOR EM WORKS (REFER TO VOL. III FOR DETAILED SPECIFICATIONS FOR EQUIPMENT) NAME OF TENDERER : Bid No: Sl No. Description Quantity Unit Price of Each Quantity Total Price GST Total Price With GST |
| 30 | 2.0 Turbine |
| 31 | Guide Vane bearing bushes (top and bottom) |
| 32 | Guide Vane stem packing |
| 33 | Guide Vane bolts |
| 34 | Safety element |
| 35 | Shaft Seal packings |
| 36 | Set of gaskets, seal, ‘O’ rings of all types and size |
| 37 | Bushes for regulating mechanism |
| 38 | Shaft protective sleeve provided at shaft gland seal |
| 39 | Bearing shell for Turbine Guide Bearing |
| 40 | Level switches ELECTRONIC GOVERNOR |
| 41 | Control Unit/Cards |
| 42 | I/O Modules ( Digital- 25%, Analogue -25%) |
| 43 | Signal Insulator |
| 44 | Speed Sensing card with Auxiliary Relay (ABB/ OEN Make) |
| 45 | Communication Card |
| 46 | Proximity Switch with Disk and Speed Switches Magnetic pick-up |
| 47 | Auxiliary Relays (ABB/ OEN Make) OIL PRESSURE UNIT & PUMP |
| 48 | Governor Oil Pump Motor set |
| 49 | Hydraulic Amplifier |
| 50 | Diaphragm for Hydraulic Amplifier |
| 51 | Pressure Relief cum Unloader Valve |
| 52 | Pressure Relief Valve |
| 53 | Check Valve |
| 54 | Servo Valve (Proportional Type) |
| 55 | Directional Control Valve |
| 56 | Directional Poppet Valve |
| 57 | Coils for Servo/Poppet Valve |
| 58 | Pressure Line Filter |
| 59 | Return Liner Filter |
| 60 | Seal and Packing |
| 61 | Temperature Gauge |
| 62 | Pressure Gauge |
| 63 | Pressure Transmitter – Digital (4- 20 mA) |
| 64 | Pressure Switches |
| 65 | Level Switches COOLING WATER SYSTEM A Pumps (if applicable) |
| 66 | Impeller |
| 67 | Mechanical Seal B Automatic Motorized Self-Cleaning Strainers |
| 68 | Strainer Element |
| 69 | Geared Motor |
| 70 | Gaskets |
| 71 | Drainage electric Valve with Motor C Valves & Instruments: |
| 72 | Valves |
| 73 | Pressure Gauge |
| 74 | Differential Pressure Switch (4-20 mA) |
| 75 | Pressure Switch |
| 76 | Flow Transmitter & Switch |
| 77 | Temperature Indicator |
| 78 | Components of Starters for Pumps & Control LP COMPRESSED AIR SYSTEM |
| 79 | Safety Valve |
| 80 | Pressure Gauge |
| 81 | Pressure Switch STATION DRAINAGE WATER PUMPS |
| 82 | Impeller |
| 83 | Rotor Shaft |
| 84 | Upper Bearing |
| 85 | Lower Bearing |
| 86 | Upper Mechanical Seal |
| 87 | Lower Mechanical Seal |
| 88 | Cable Entry Kit |
| 89 | O-Ring |
| 90 | Fasteners in Liquid |
| 91 | Valves |
| 92 | Pressure Gauge |
| 93 | Pressure Switch |
| 94 | Components of Starters for Pumps & Control Dewatering Pump (Main Pump) |
| 95 | Impeller |
| 96 | Rotor Shaft |
| 97 | Upper Bearing |
| 98 | Lower Bearing |
| 99 | Upper Mechanical Seal |
| 100 | Lower Mechanical Seal |
| 101 | Cable Entry Kit |
| 102 | O-Ring |
| 103 | Fasteners in Liquid |
| 104 | Valves |
| 105 | Pressure Gauge |
| 106 | Pressure Switch |
| 107 | Components of Starters for Pumps & Control Dewatering Pump (Portable Submersible Sump Pump for DryValve Pit) |
| 108 | Impeller |
| 109 | Rotor Shaft |
| 110 | Upper Bearing |
| 111 | Lower Bearing |
| 112 | Upper Mechanical Seal |
| 113 | Lower Mechanical Seal |
| 114 | Cable Entry Kit |
| 115 | O-Ring |
| 116 | Fasteners in Liquid LUBRICATING OIL PURIFYING SYSTEM |
| 117 | Oil Inlet Pump |
| 118 | Motor for Oil Inlet Pump |
| 119 | Oil Discharge Pump |
| 120 | Motor for Oil Discharge Pump (Not required in case of Mono Bock pump) |
| 121 | Vacuum Pump |
| 122 | Motor for Vacuum Pump |
| 123 | Gasket & Seals |
| 124 | Flexible Nitrile Rubber hose pipe with flanged end connections on both sides (Length – 10 m) MAIN INLET BUTTERFLY VALVE |
| 125 | Disc Seals of synthetic Nitrile rubber each for Service Seal and Maintenance Seal. |
| 126 | Clamping Ring/Retaining Ring of each type for the Valve Seal (with Ring Bolts) |
| 127 | Trunnion Bearings |
| 128 | All Packing, Seals etc. for Trunnion Bearings |
| 129 | All Packing, Seals etc. for Servomotors |
| 130 | All Packing, Seals etc. for Bypass Valve |
| 131 | Piston Rings and Bushings for Hydraulic Servomotors |
| 132 | ‘O’ Ring (Nitrile rubber) of Shaft Pin |
| 133 | Seals (‘O’ Ring) for Gate Valves |
| 134 | Spares for Air Release Valve |
| 135 | Spares for Anti Vacuum Valve |
| 136 | Spares for Needle Valve |
| 137 | Limit Switch |
| 138 | Proximity Switch |
| 139 | Auxiliary Relays/ Contacts (ABB Make) |
| 140 | Timers |
| 141 | Power Contactors with Overload Relays FIRE DETECTION SYSTEM |
| 142 | Multi-Sensor Smoke Detectors |
| 143 | Photoelectric type Smoke Detectors |
| 144 | Heat Detector |
| 145 | Response Indicator |
| 146 | Spares for fire fighting system Ventilation |
| 147 | Air Filter - Bag type |
| 148 | V-belts |
| 149 | Motor set of Air Handling Unit Fan |
| 150 | Circuit Breakers & Contactors for Motor Starter Panels EOT CRANE A MAIN HOIST |
| 151 | Thruster to serve Hoist Brake |
| 152 | Brake Shoe with lining for the Hoist Brake |
| 153 | Brake Solenoid coils complete |
| 154 | Limit Switches of each type B AUXILIARY HOIST |
| 155 | Thruster to serve Hoist Brake |
| 156 | Brake Shoe with lining for the Hoist Brake |
| 157 | Brake Solenoid coils complete |
| 158 | Limit Switches of each type C TROLLEY DRIVE |
| 159 | Fixed and moving contacts & accessories for the Controller for Traverse Drive |
| 160 | Brake Solenoid coils complete |
| 161 | Brake Shoe with lining for Transverse Brake |
| 162 | Limit Switches of each type D BRIDGE TRAVEL DRIVE |
| 163 | Fixed and moving contacts for the controller of Long Travel motion |
| 164 | Brake Solenoid coils complete |
| 165 | Brake Shoe with lining for Bridge Travel Brake |
| 166 | Limit Switches of each type E OTHERS MISC. SPARES |
| 167 | Coils of each model for the Starters and Control Switches |
| 168 | Rectifiers for each model of Solenoid-operated Brakes |
| 169 | Circuit Breaker of each type |
| 170 | Springs, O-rings, Oil seals, Gaskets, Packing etc. of each size and type for complete Crane |
| 171 | Indicating Lamps each type |
| 172 | Indicating light assembly of each type |
| 173 | Couplings complete with coupling bolts, rubber sleeves etc. each type and size |
| 174 | Push button each type |
| 175 | Control Switch of each type |
| 176 | Disconnecting Switch of each type |
| 177 | Terminal Block of each type |
| 178 | Fuse Block of each type |
| 179 | Plug Connector of each type |
| 180 | Plug Module of each type |
| 181 | Current Collection Assembly (Each Type) F VVVF Drive Spares |
| 182 | Power Card for MH-1No, AH-1 No, CT-1No, & LT-1No. |
| 183 | Control Card for MH-1No, AH-1 No, CT-1No, & LT-1No. |
| 184 | IGBT Module MH-1No, AH-1No. |
| 185 | IGBT Module CT-1No, LT-1No. Generator |
| 186 | Upper Guide Bearing Pads |
| 187 | Thrust bearing pads |
| 188 | Lower guide bearing pads |
| 189 | Brake lining / Brake pads |
| 190 | Stator Cooler unit |
| 191 | Oil cooler for lower guide bearing |
| 192 | Oil cooler for combined thrust and guide bearing |
| 193 | RTD for cooling air inlet |
| 194 | RTD for hot air outlet |
| 195 | RTD for upper guide bearing |
| 196 | RTD for combined thrust and guide bearing |
| 197 | Dial type thermometer |
| 198 | Water flow relay for cooling circuits |
| 199 | Gasket for brake cylinders |
| 200 | Gasket, washer for air coolers |
| 201 | Friction Brake (Cushions) Pads |
| 202 | Gate valves & valves for water & oil pump |
| 203 | Vibration sensor |
| 204 | Oil moisture detector |
| 205 | Coils, contacts, spring for relays, contractors, breaker, switches |
| 206 | Level switch, pressure switch, pressure gauge with electrical contacts |
| 207 | Bearing oil level indicator for LOS |
| 208 | Rotor collector assembly (slip ring) with all insulation material |
| 209 | Generator speed sensor |
| 210 | Mechanical over speed device |
| 211 | Hydraulic over speed device |
| 212 | Air cooler water flow indicator |
| 213 | Automatic air vent valves for Bearing oil coolers, Air coolers etc. |
| 214 | stator winding including installation material-33% of total cost or 3rd of total coil for one generator |
| 215 | Air gap sensor (if opted) Excitation System |
| 216 | Modules of DVR like DC-DC converter, ac-dc converter, digital control unit, pulse supervision unit, pulse final stage unit, analog input-output modules, etc. |
| 217 | Spare parts of field discharge breaker comprising of : Opening coils, Closing coils, Main contact, Discharge contact |
| 218 | Field discharge resistor Latch and trigger assembly, Auxiliary contact block |
| 219 | Spare Parts of Rectifier bridge: Complete Thyristor bridge c / w racking components |
| 220 | Spare Parts of Rectifying equipment: Thyristors- Thyristors fuses, Cooling fan for thyristor bridge, Field flashing contactor, Fuses of various ratings, MCBs of various ratings, Air flow sensor, MCCBs of various ratings, Micro terminal for MMI Aux relays / contactor, AC and DC isolator with micro switch, Heat sinks for Thyristors, Clamps for Thyristors, Snubber Assemblies for Bridge, Pulse transformers, Power transistors |
| 221 | Protection Relays- Rotor earth fault relay (I / II stage), Transformer O / C relay |
| 222 | Spare Parts for circuit breakers: Closing Coil, Tripping Coil, Arcing contact, Arc Chute, 4 Pole aux. Switch |
| 223 | Varistor Discs |
| 224 | Plug in Circuit cards |
| 225 | Terminal Blocks (100 Nos) |
| 226 | Contactors- DC Contactors, AC Contactors |
| 227 | Spare parts for Excitation Transformer such as temperature scanner, insulator, braided connector etc. Generator Step-up (GSU) Transformer |
| 228 | HV bushing complete with gaskets etc. |
| 229 | LV terminal bushings of 11 kV or as specified in technical specifications complete with gaskets. |
| 230 | HV neutral bushing and gaskets. |
| 231 | Gaskets for all openings with tank requiring gaskets |
| 232 | Oil and winding temperature indicators |
| 233 | Silica gel drying agent / required for one filling of transformers |
| 234 | Diaphragm and spares for conservator tank |
| 235 | Oil level indicator |
| 236 | Buchholz relay |
| 237 | Air dryer / silica gel breather |
| 238 | Neutral C.T. |
| 239 | Safety valve / Pressure relief valve |
| 240 | Spares of off-circuit Tap Changer |
| 241 | Magnetic oil level gauge |
| 242 | Set of valves |
| 243 | Fuses, MCCB and MCB‟s, Terminal Block |
| 244 | Indication Lamps |
| 245 | One (1) Limb of HV winding in a separate oil filled tank, One (1) Limb of LV winding in a separate oil filled tank |
| 246 | Indicating Lamps with holders and Lens Station Service Transformer |
| 247 | H.V bushing complete with gaskets etc. |
| 248 | L.V terminal bushing as specified in technical specifications. |
| 249 | Neutral bushing and gaskets. |
| 250 | Gaskets for all openings with tank requiring gaskets |
| 251 | Silica gel drying agent / required for one filling of transformer |
| 252 | Diaphragm and spares for conservator tank & explosion vent and pressure relief valve |
| 253 | Buchholz relay |
| 254 | Neutral Current Transformer |
| 255 | Fuses, MCCB and MCB’s, Terminal Block |
| 256 | Oil and winding temperature indicators |
| 257 | Indicating Lamps with holders and Lens |
| 258 | Magnetic oil level gauge Medium Voltage Switchgear |
| 259 | 33 kV circuit breaker |
| 260 | Circuit breaker trip and closing coils. |
| 261 | Fixed and moving finger contacts of type used for each set comprises 6 fixed and 6 moving contacts) |
| 262 | Bus insulator |
| 263 | Indicating meter of each type used |
| 264 | Over current relays |
| 265 | Over current and earth fault relay |
| 266 | Indicating lamps with assembly of each type used AC Auxiliary System |
| 267 | Spring charging universal motor (operable on 240 V AC) for draw-out circuit breakers |
| 268 | Closing Coils for circuit breakers |
| 269 | Tripping Coils for circuit breakers |
| 270 | Main contacts for circuit breakers: |
| 271 | Secondary contacts for circuit breakers; |
| 272 | Breaker control switch |
| 273 | Solid-state overcurrent trip devices without ground fault element; |
| 274 | Solid-state overcurrent trip devices with ground fault element; |
| 275 | CT & PT |
| 276 | Indicating Lamps |
| 277 | Push button |
| 278 | MCBs / HRC Fuses |
| 279 | Under voltage relay (27). |
| 280 | MCCB - Auxiliary switch / contact |
| 281 | MCCB -Operating knob handle Protection |
| 282 | 50/51 relays |
| 283 | Single phase metrosil (if used) |
| 284 | Three phase metrosil (if used) |
| 285 | Test block |
| 286 | Tripping relay of type used |
| 287 | Trip circuit supervision of type used |
| 288 | Auxiliary relays of type used |
| 289 | Auxiliary relays socket of type used |
| 290 | Fuse blocks & Fuses, Heavy Duty terminal blocks, internal tined copper wires. |
| 291 | Protection Relays of each type SCADA A Spares for Central Control Room Equipment |
| 292 | Operator Work Station PC/ Process Server PC comprising, mouse, keyboard, network interface cards |
| 293 | Monitor- Colour, TFT LED (LED backlit), 22-inch screen, for OWS/Server and EWS PC |
| 294 | Large Video Screen; 1 x 55” LED/LED screen with connecting & mounting hardware, DVI cable, network interface and connectors B Process bus gigabit Ethernet TCP/IP |
| 295 | Multimode gigabit Ethernet switch; Two (2) nos. of each type |
| 296 | Single-mode gigabit Ethernet switch; Two (2) nos. of each type |
| 297 | Other network component like patch panels, repeaters/ hubs [Two numbers of each type] C Field bus media converter modules |
| 298 | Multimode Media converter module with connecting hardware [Two numbers of each type] D Field bus connectors [of each type] |
| 299 | Multimode Media converter module with connecting hardware [Two numbers of each type] |
| 300 | Field bus connectors [of each type] |
| 301 | Other cards/ modules [for GPS based Time synchronizing system- synchronizing pulse distribution, power supply etc.] (each type) |
| 302 | Slave clock for GPS based Time synchronizing system (Large Digital display LED/LED) |
| 303 | Multifunctional B/W Laser Printer Ink Cartridges |
| 304 | Colour Laser Printer Ink Cartridges |
| 305 | Dot Matrix Printer Ink Ribbon |
| 306 | B/W Laser Printer Ink Cartridges E Spares for Group/ Local Control cubicles (Unit Control Board, Common auxiliary and control cubicles) |
| 307 | PLC set [complete with redundant power supply cards, CPUs, communication interface cards, 19” mounting rails/ racks, synchronizing modules, FO synchronizing cable & connectors, backup batteries, memory card and other accessories] |
| 308 | HMI touch screen, Panel mounted Monitor |
| 309 | Process I/O cards (DI, DO, AI and AO cards) (Four (4) numbers of each type) |
| 310 | Field isolation (Optical/ Electromagnetic) auxiliary relays, front connectors, interface modules, flat intra panel cables and necessary for I/O cards at 2.3 above including, connectors, patch cords and splice box. (Four (4) numbers of each type) |
| 311 | Field-bus Interface module/ and connecting prefabricated cables, Two (2) numbers of each type |
| 312 | Ethernet communication processor cards/ module (Two (2) numbers of each type) |
| 313 | Power supply modules/ DC-DC converters, 220V to 24 V/48V (Two (2) numbers for each type & rating) |
| 314 | Automatic synchronizer |
| 315 | Synchro check relay |
| 316 | Manual synchronizing devices (push buttons, control switches, pilot lamps) and instruments (Voltmeter, Frequency meter, DV, DF). (One (1) number of each type) |
| 317 | Protection tripping Relays c/w socket (1 of each type) |
| 318 | Auxiliary Relays c/w socket (4 of each type) |
| 319 | Interposing Relays c/w socket (12 of each type) |
| 320 | Miscellaneous Indicating lamps, rotary switches, semaphore indicators, push buttons, special relays, indicator and alarm switches; 20% or two (2) no - [whichever is higher] each type |
| 321 | Terminals, ferrules, ac & dc power supply MCBs, auxiliary contacts, diodes for power supply isolation. 20% or two (2) no [whichever is higher] of each type |
| 322 | Fuses (200%) of each type |
| 323 | Other cubicle spares and accessories, Door limit switches, space heaters, illuminating lamp, power sockets, cubicle cooling fan etc. (4 of each type) DC System |
| 324 | Control Cards. |
| 325 | PCBs of each type used. |
| 326 | Discrete components like SCRs, diodes, capacitors, resistors, potentiometers etc. |
| 327 | Trip indicating fuses, fuses and fuse base (as applicable). |
| 328 | Power / auxiliary contactors, contactor coils and contact kit |
| 329 | MCCB auxiliary switch / contact. |
| 330 | Indicating lights. |
| 331 | Push buttons. |
| 332 | Toggle switches. |
| 333 | CT and Shunt. |
| 334 | Under voltage, over voltage, earth fault relay. |
| 335 | Motorized MCCB UPS System |
| 336 | Control Cards |
| 337 | PCBs of each type used |
| 338 | Discrete components like SCRs, diodes, capacitors, resistors, etc. |
| 339 | Trip indicating fuses, fuses & fuse base (as applicable) |
| 340 | Power / auxiliary contactors. Contactor coils and contact kit |
| 341 | MCCB auxiliary switch / contact |
| 342 | Indicating lights |
| 343 | Push buttons |
| 344 | Toggle switches |
| 345 | CT & Shunt |
| 346 | Undervoltage relay Cables |
| 347 | Spare cable lengths of each type and size of power cables used |
| 348 | Termination kits for each type and size of cable Lighting Boards / Panels |
| 349 | Each rating of isolator |
| 350 | Each rating of HRC fuse |
| 351 | Each rating of MCB and MCCB |
| 352 | Each rating of contactor |
| 353 | Each rating of push button |
| 354 | Synchronous Timers Lighting Fixtures |
| 355 | Each type of fixtures complete with accessories without lamps |
| 356 | Lamps Receptacles |
| 357 | Each type of receptacle |
| 358 | Junction boxes (each type) |
| 359 | Trunking / conduits DG SET |
| 360 | Oil filter |
| 361 | Fuel filter |
| 362 | Nozzle |
| 363 | Complete set of belts |
| 364 | Air filter element |
| 365 | Relay |
| 366 | Pressure switch |
| 367 | Temperature switch |
| 368 | Level switch |
| 369 | Fuses |
| 370 | Indicating lamps |
| 371 | Electronic card |
| 372 | Sets of gaskets and “O” ring |
| 373 | Fuel injectors |
| 374 | Trip & closing coil of ACB |
| 375 | Rotating diode assembly EPBAX |
| 376 | Each type of loud speakers with wall mounting arrangements |
| 377 | Telephone sets with wall / column / structure mounting arrangements |
| 378 | Head microphones |
| 379 | Power supply cards used in the amplifier system |
| 380 | Electronic cards of each type used in the system |
| 381 | Cables of all type |
| 382 | CCTV system equipment Camera of each type SWITCHYARD EQUIPMENT |
| 383 | Trip coils of CB |
| 384 | Closing coils of CB |
| 385 | Spring charging Motors |
| 386 | Operating mechanism box of Isolator |
| 387 | Isolator with earth switch |
| 388 | Current Transformers |
| 389 | Voltage transformers |
| 390 | Insulators string- i Suspension ii Tension |
| 391 | All types of clamps (for main conductor of earth wire) |
| 392 | ACSR conductor |
| 393 | Lightning arrestor along with Surge counter, insulating base and connecting copper braids |
| 394 | Post Insulator 0.0 Note:1) Total shall be a part of the prices indicated in Section BoQ1 2) The currency shall Indian Rupees only. SECTION F1 - 3 LIST OF MANDATORY MAINTENANCE & ERECTION TOOLS AND TACKLES FOR EM WORKS NAME OF TENDERER : Bid No: Tenderer shall give the price of maintenance and erection tools and tackles. Sl No. Description Qty. Unit Price of Each Quantity Total Price GST Total Price with GST |
| 395 | 5000V range digital megger |
| 396 | Tong tester 0-1000A clip on volt meter and ammeter |
| 397 | Digital multimeter |
| 398 | Hand held type phase sequence meter 50 to 500V |
| 399 | Blower |
| 400 | Soldering iron |
| 401 | Hand held speedometer |
| 402 | Vernier callipers 300 mm |
| 403 | Dial gauge with magnetic base 0.01 mm accuracy |
| 404 | Micrometer |
| 405 | Inside outside callipers |
| 406 | Ring Spanners & double end open jaw spannere 5 mm to 36 mm set 36x41, 46x51 & 50x55m size |
| 407 | Single end open jaw & single end ring spanners 46, 50, 51 and 55 mm |
| 408 | Box spanner 10 to 32 mm with accessories |
| 409 | Circlip opener (Inside and outside) 6\\" |
| 410 | Hammers Ball peen 1 Kg and straight- 5 kg & 10 kg |
| 411 | Pistol hand drilling machine |
| 412 | Shim cutter 12\\" size |
| 413 | Pipe wrench 18\\", 24\\" |
| 414 | Screw wrench 18\\", 24\\" |
| 415 | Allen key 5 mm to 24 mm |
| 416 | Cutting pliers 6\\" & 8\\" size |
| 417 | Nose pliers 6 \\" & 8 \\" size |
| 418 | Hacksaw frame 12\\" |
| 419 | Rough & Smooth flat, round, half round and triangular file 12\\" size |
| 420 | Centre punch & letter punch |
| 421 | Chisels 4\\", 6\\", 8\\" and 12\\" |
| 422 | Bench vice 12\\" size |
| 423 | Screw drivers 6\\", 9\\", 16\\" |
| 424 | Wire slings 5 and 10 ton capacity |
| 425 | \\"D\\" Shackles 5 and 10 ton capacity |
| 426 | Feeler gauge 0.05 mm to 1 mm size 6\\", 18\\" |
| 427 | Master level- Accuracy 0.02/mtr length, range 0-150 mm |
| 428 | Turbine consisting of following: i Complete set of casehardened wrenches above 24mm, neatly packed in a metal toolbox for convenient storage; 1.0 Set ii Test cards extension, dummy loads, and test loads that shall be necessary for Governor electronics testing 1.0 Set |
| 429 | Main Inlet Valve-Hydraulic Bolt Tensioner |
| 430 | Generator & Excitation System consisting of following: i All spanners including D ring and box type of all sizes, 2.0 Set ii Torque wrenches of each size and hydraulic bolt tensioner for coupling bolts having the complete set of drives / boxes mounted on the cabinet, 2.0 Set iii All precision tools required for assembly, alignment and maintenance of the hydro generator as per the indicative list mentioned below: 1.0 Set iv Dial indicators (accurate to 0.01 mm) with magnetic base, 10.0 Set v 200 mm and 300 mm master block level (least count 0.02 mm / m) each, 1.0 Set vi Micro meters (inside and outside) (0-50, 50-100, 100150, 150-300); 1.0 Set vii Height gauges, 2.0 Set viii Vernier callipers (150 mm to 1000 mm), 1.0 Set ix Knife-edges up to 1 m, 3.0 Set x Straight edge 1000 mm, 3.0 Set xi Feeler gauges from 0.05mm to 1mm in denomination of 0.05 mm, 300 mm long, 6.0 Set xii Measurement of magnetic axis, air gap, rotor and stator from, etc, 1.0 Set xiii Pole assembly and removal devices / tools, 1.0 Set xiv Brazing / soldering equipment / device for stator bars / rotor including all tools, etc. (may specify the list of included items), 2.0 Set xv All types and sizes of eye bolts and D shackles and special slings. 3.0 Set xvi Removal / assembly arrangement devices and tools for all of the thrust and guide bearings, 2.0 Set xvii Coupling assembly and dismantling arrangements, special devices, tools, elongation measurement, instruments, including hydraulic and mechanical jacks, etc, 2.0 Set |
| 431 | Generator Transformers other Auxiliary Transformers consisting of following: i Oil filtration system complete with hoses, accessories etc. as per technical specification 1.0 Set ii Jacks required for lifting of Power Transformer 1.0 Lot iii Oil Sampling bottle of stainless steel having 1 litre capacity each along with impermeable oil proof, transparent plastic or rubber tube of 5 mm diameter (of sufficient length) along with suitable connectors to fit the tube on to the oil sampling valve of the transformer and the oil collecting bottles respectively. The bottles shall be capable of being sealed gas tight and shall be fitted with cocks on both ends. 2.0 Set iv Set of chain pulley block of suitable capacity required for handling of items in transformer vault along with required sling etc. 1.0 Lot v Winches of required capacity required for movement of GT on Track along with required accessories. 1.0 Lot vi Spanners including D ring and box type of all sizes 2.0 Set vii Set of all types and sizes of eye bolts 1.0 Lot viii Torque wrenches of each size 2.0 Set ix Racks for storage of Tools and Tackles 2.0 Set x Rails for movement of transformers (refer layout drawing) 1.0 Lot |
| 432 | 415V Low Voltage Switchgear consisting of following: i Additionally racking handles for trolley and handles for manual charging of spring motors shall be supplied one for each cubicle. 1.0 Set ii One lifting and transfer truck for draw-out circuit breakers, 1.0 Set iii One portable test set for test purposes and calibration of the circuit breaker overcurrent tripping devices, 1.0 Set iv One device for slow closing, 1.0 Set v One set of templates 1.0 Set vi One set of gauges 1.0 Set vii One set of special keys for contact adjustment 1.0 Set |
| 433 | Control and Monitoring System Automation consisting of following: i Equipment QuantityStandard Electronic Tool kit [Comprising Digital Multi-meter, loop check/ Continuity testers, set of screw drivers, wire-stripper, crimping tool] 2.0 Set ii Optical fibre Splicing kit 1.0 Set iii Optical fibre network testing kit 1.0 Set iv Tag printer 1.0 No Total 0.0 Note:1) Total shall be a part of the prices indicated in Section BoQ1 2) The currency shall Indian Rupees only. SECTION F1 - 5 OPTIONAL SUPPLY NAME OF TENDERER : Bid No: TENDERER shall fill out the schedule below for all OPTIONAL SUPPLY. Sl No. Optional Supply Description Qty. Unit Price of Each Quantity Total Price GST Total Price with GST 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 TOTAL PRICE 0.0 TOTAL PRICE Notes: a) The currency shall Indian Rupees only. b) The above prices shall not be considered for evaluation purpose but mandatory to submit with this BOQ SECTION F1 - 4 LIST OF RECOMMENDED MAINTENANCE & ERECTION TOOLS AND TACKLES- FOR EM WORKS NAME OF TENDERER : Bid No: TENDERER shall give below the list of recommended maintenance and erection tools and tackles offered by him. Sl No. Description Qty. Unit Price of Each Quantity Total Price GST Total Price with GST 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Note: 1) The above prices shall not be considered for evaluation purpose but mandatory to submit with this BOQ 2) The currency shall Indian Rupees only. SECTION F1 - 6 ABSTRACT OF SCHEDULE PRICE SCHEDULE :Local Transportation at project site,storage,erection,testing and commissioning of electro mechanical plant NAME OF TENDERER: BID NUMBER: Sl. No. Description Qty Unit Price Total Unit Price GST Total Price(all Price Schedule) with GST |
| 434 | EM Works - Unloading at site, storage, transportation from stores to installation place etc. of all items covered in Schedule of requirement and in Technical Specification |
| 435 | EM Works - Erection, Testing & Commissioning of Complete Units (including supervision) as specified in the Technical Specification |
| 436 | Field Efficiency Testing for Turbines as per IEC 60041 as per specified in the Technical Specification ) |
| 437 | Field Efficiency Testing for Generators, as per IEC 60034-2 as per specified in the Technical Specification |
| 438 | Training of Employer’s Personnel |
| 439 | TOTAL SERVICES Note:-1.In case of discrepancy between unit price and total price, the unit price shall prevail.The currency shall Indian Rupees only. 2. Labour cess is applicable in work.GST is applicable to the quoted price.All duties, taxes, cess, transportation, insurance and other levies (it should be specific) payable by the contractor as per State / Central Government rules, shall be included in the bid price quoted by the Bidder. Employer will not bear any liability on account of any taxes/duties/cess/insurance/transportation and other levies applicable on the supply and services/works. Employer shall however deduct taxes at source as per the rules and issue necessary certificate to the contractor. SECTION F1 - 7 LIST OF RECOMMENDED SPARE PARTS FOR EM WORKS NAME OF TENDERER: BID NUMBER: TENDERER shall give below the list of recommended spare parts offered by him. Sl No. Description Qty. Unit Price of Each Quantity Total Price GST Total Price with GST 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 0.0 Total 0.0 Note : 1) The above prices shall not be considered for evaluation purpose but mandatory to submit with this BOQ 2 ) The currency shall Indian Rupees only. Please Enable Macros to View BoQ information |
| SR No | FileName | File Description |
| 1 | Click here to download tender document | Tender Documents |
| 2 | Click here to download tender document | Tender Documents |
| 3 | Click here to download tender document | Tender Documents |
| 4 | Click here to download tender document | Tender Documents |
| 5 | Click here to download tender document | Tender Documents |
| 6 | Click here to download tender document | Tender Documents |
| 7 | Click here to download tender document | Tender Documents |
| 8 | Click here to download tender document | Tender Documents |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy
For Tender Information Services Visit : TenderDetail