| 1 | Taking down old Unsv LT UG cables of size upto 50 Sqmm from trenches / poles / ducts etc complete all as specified and directed. |
| 2 | Supplying, laying, jointing, commissioning and testing XLPE insulated screened PVC bedded, armoured, heavy duty underground electric cable with stranded aluminium conductor 1100 volts grade confirming to IS-7098 (Part-I-1988) laid in trenches/ducts/wall / floor / pipes/ poles including cable glands and aluminium lugs of appropriate size, pvc sleeve etc complete all as directed by Engr-in-Charge for following sizes:- Make :- Havells / Gloster / Finolex / PolycabNOTE :- Earth work , bricks , riddled earth , GI pipe for protection of cable will be measured & paid under relevant items of schdule . |
| 3 | 50 Sqmm 3.5 core . |
| 4 | 35 Sqmm 3.5 core |
| 5 | 25 Sqmm 3.5 core |
| 6 | 16 Sqmm 4 core. |
| 7 | 10 Sqmm 2 core |
| 8 | 6 Sqmm 2 core |
| 9 | Excavation in trenches not exceeding 1.5mtr wide and not exceeding 1.5mtr in depth for foundation of poles stays laying of electric cables, pipes etc and getting out in soft/loose soil complete all as specified and directed. |
| 10 | All as per item No. 3 above but in hard/dense soil complete all as specified and directed. |
| 11 | Removing excavated material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above starting point complete all as specified & dierected. |
| 12 | Returning, filling in soil including spreading levelling, watering and well ramming in layers not exc 25cm complete all as specified and directed by Engr-in-Charge. |
| 13 | Material and Labour for riddled earth for cushioning to under ground electric cable including spreading , levelling and hand punning complete all as specified and directed. Note - Punned thickness shall only be measured & paid . |
| 14 | Material & Labour for road cutting / foot path and making good with PCC 1:3:6 Type C-2 (using 40 mm graded stone aggregate) of 150mm depth complete all as specified and directed. |
| 15 | Supply and laying un-reinforced precast concrete cable cover LV, Type I, flat, size 250mm x 150mm x 40mm for under ground cable complete all as specified and directed. |
| 16 | Supply and lying GI tubes light grade, galvanised, 40mm bore in repair, laid in trenches or under floor or fixed with poles/walls for protection of electric cable complete all as per specified and directed. |
| 17 | All as per item no -10 above bore but 80 mm bore, complete all as specified and directed. |
| 18 | Material and Labour for plain cement concrete (PCC) 1:3:6, type C2 (40mm graded stone aggregate) for making foundation of Pole/stay assembly complete all as specified and directed. |
| 19 | Material and Labour for plain cement concrete (PCC) 1:3:6, type C1 (20mm graded stone aggregate) for making copings of Poles etc complete all as specified and directed. |
| 20 | Material and labour earthing complete with galvanised steel earth plate eletrode 600x600x6mm thick buried directly in ground earth pit not less than 2.25mtr deep below normal ground level with top edge of the plate not less than 1.5m below normal ground level, connected to the earth lead wire 4.0 mm dia (GI wire) size, by means of bolts, nuts, check buts and washers of galvanised iron, earth lead wire 4.0 mm dia protected by provision of GI medium grade pipe 15 mm bore including provision of aggregates with 40 mm thick cover of RCC (1:2:4) , re-inforced with XPM (weight not less than 4 kg per sqmm) and frame of angle iron 40x40x3 mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at bottom 1.75 mtr long placed on top edged of earth plate, common salt and charcoal filling, funnel, wire mesh and earth work in hard/dense soil, returning filling in distance not exe 50 mtr and removal of surplas soil to plate No 3 of SSR 2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion complete all as specified and directed. |
| 21 | Material and labour in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60cmx6 mm thick, buried directly in ground vertically (earth pit not less than 2.25 mtr deep below ground level) with top edge of the earth plate not less than 1.5mtr below ground level , connected to 32 mm x 6 mm GI strip as earthling lead by means blots and nuts check nuts and washers of galvanized iron and connected to main switch board including watering arrangement with PCC chamber , MS funnel, wire gauge. CI cover with frame, 50 MM dia GI pipe light grade for protection of wire/strip etc including necessary excavation in any type of strata , returning, filling removal of soil outside MD land ,filling of charcoal and salt complete all as shown in electrical plate No. 3 of MES Sch Part I , connected to Earthing test point complete all as specified and directed on testing on completion. Note : Rate of item is deemed to be included for excavation in hard rock, by compressor machine to achieve required depth. |
| 22 | Material & Labour for detection of street light LT UG cable fault with the help of cable fault detecting machine with experinced engineer and helper including necessary earth work complete & jointing the faulty cable with new joint, testing etc complete all as specified and directed.Note: Cable joint kit will be measured and paid seperately under relevent item of schedule. |
| 23 | Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size up to 16 sqmm 2/3.5/4 core cable complete all as specified and directed. |
| 24 | Supply only straight through joint kit , heat shrinkable type suitable for LT UG electric cable 1100 volts grade of size from 25 up to 50 sqmm 3.5/4 core cable complete all as specified and directed. |
| 25 | Supply and fix in repair brass terminal 4 way, 63/100 apms capacity with bakelite insulator fixed in street light junction box complete all as specified and directed. |
| 26 | Taking down old unserviceable rusted damaged street light pole 9 mtr/11 mtr long of any type complete all as specified and directed. |
| 27 | Supply and errect in vertical position Steel tubular swaged poles, type 410 SP- 31 (09 mtr long) with 300mm x 300mmx6mm mild steel plate continiusly welded to pole, final taper plug, bolts,nuts and screws and making holes as per requirement all as specified including factory painted with two coats of black bituminous paint internally through out and externally for embeded portion and applying one coat of red oxide primer, making 05 Nos strip each 30 cm high with super enamel paint ( Black and yellow) from ground level / coping upto 1.5 meter, painting with two coats of aluminium paint for the remaning height complete all as specified and directed.Note :- PCC in foundation, copping, excavation and earth work shall be measured and paid separately under relevent items of sch. |
| 28 | Taking down old unserviceable Flood light fitting of any type/capacity from its location complete all as specified and directed. |
| 29 | Supply and Fix LED Flood light fitting of capacity 120 watts made up of pressure die cast aluminium housing with toughned glass and high power LED's and secondary lenses, having system efficiency greater than 125 lumen per watts with surge protection device included. The luminaries shall be totally enclosed dust and water proof with minimum IP -66 protection pre wired up to connector including 2.5 sq mm PVC insulated cable for making connection (upto 9 mtr height), complete all as specified and directed by Engr-in-charge.Make :- Halonix/Crompton/Benlo. |
| 30 | All as per item No. 23 above but for capacity of 150 watts, complete all as per specified and directed. |
| 31 | All as per item No. 23 above but for capacity of 200 watts, complete all as per specified and directed. |
| 32 | All as per item No. 23 above but for capacity of 500 watts, complete all as per specified and directed. |
| 33 | Dismantling and Taking down old unserviceable street light fitting of capacity upto 120 watts from its location complete all as specified & directed. |
| 34 | Supply and Fix LED Street light fitting of 100 Watt (Cool White) including LED lens complete with body robust, corrosion resistant, superior finish, made up of high pressure die cast aluminium alloy housing. The luminaries shall be totally enclosed, dust and water proof with minimum IP - 66 protection as per IS - 10322-1982(Part -I) with latest amendments and input voltage range 140 to 300 V, AC, frequency 50 to 60 Hz, P.F should be more than 0.95 with Total Harmonic Distoration THD(I) less than 10% , cool white colour and lamp starting time should not be more than 10 second fitting should be provided with 10 KV surge protection. Driver should be constant current constant voltage driver .Driver should have high voltage withstanding capacity upto 300 V, AC. Driver should also have double phase protection,no load , open circuit and short circuit protection . The efficiency of LED luminaries system shall be more than 110 lumens per watt and must be certified by the LM-79 test report and including provision of connection for street light from pole box with 2.5 Sqmm PVC insulated stranded copper conductor FRLSH cable (upto the length of 9 mtr) complete all as specified and directed by Engineer-in- charge.Make :- CROMPTON / HALONIX /HAVELLS/PHILIPS |
| 35 | All as per item No. 25 above but for capacity of 60 Watt Make:- CROMPTON/ HALONIX /HAVELLS/PHILIPS |
| 36 | All as per item No. 25 above but for capacity of 45 Watt Make:- CROMPTON / HALONIX /HAVELLS/PHILIPS |
| 37 | Supply & fixing in repairs Bracket for fixing of street light fittings bend to shape, made out of 40 mm dia GI pipe medium grade upto 1.5 mtr long fixed with two sets of MS clamps made out of flat iron of size 50 mm x 6 mm fabricated to shape and fixed with nuts bolts and washers & two coats of aluminium paints over and including a coat of red oxide primer complete all as specified and directed by Engr-in-Charge(Note : The rates are inclusive of MS clamps, nuts, bolt and washer) |
| 38 | Supply & fixing three core PVC insulated and FRLS PVC round sheathed, copper conductor 1100 volts grade cable of size 1.5 sqmm (multi stranded) complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |
| 39 | Supply & fixing three core PVC insulated and FRLS PVC round sheathed, copper conductor 1100 volts grade cable of size 1.5 sqmm (multi stranded) complete all as specified and directed by Engr-in-charge. Please Enable Macros to View BoQ information |