| 1 | DESERT COOLERDismantling and taking out water pump fan motor and water distribution pipes from the desert cooler carrying out minor repair and fixing 14 SWG wire mesh for fixing the pads to shutters rearranging the pads and refixing motor pump PVC pipe distributor and sutters in existing positions complete all as specified and directed by Engr-in-Charge. |
| 2 | Dismantling and taking all minor parts and removing existing paint/treatment from the desert cooler completely and preparing the surface and applying externally one coat of synthetic enamel spray paint over a coat of red oxide primer (shutters shall be painted all round i.e. externally internally with one coat of synthetic enamel spray paint over a coat of red oxide primer) and painting cooler body internally with one coat of bituminous paint and refixing motor pump PVC pipe distributor and sutters in existing positions complete all as specified and directed by Engr-in-Charge. |
| 3 | Taking down old unsv PVC flexible tubing distributor and elbows and providing new PVC flexible tubing distributor and elbows for desert coolers complete all as specified and directed by Engr-in-Charge. |
| 4 | Supply and fixing new fan motor in replacement of old motor of 1/7 hp or 1/10 hp, 1350/1400 RPM, copper winding, AC Single Phase 230V 50Hz three/four speed with capacitor blades and brackets including necessary wiring complete all as specified and directed by Engr-in-Charge |
| 5 | Supply and fixing of capacitor in replacement of old capacitors having 3.15/4.00 mfd suitable for fan motor of desert cooler complete all as specified and directed by Engr-in-Charge. |
| 6 | Supply and fixing of submersible pump of desert cooler single phase 18W, Max height upto 2 mtr, AC 230V, 50Hz in replacement of old unsv Submersible pump including necessary connection and testing complete all as specified and directed by Engr-in-Charge. |
| 7 | Ditto All as per item no 6 above but for 40W, Max height upto 3 mtr |
| 8 | Supply and fixing of selector switch 60W 3 step speed control (LOW/MEDIUM/HIGH) in replacement of old switch of desert cooler complete all as specified and directed by Engr-in-Charge |
| 9 | Supply and fixing of switch 5 Amp for water pump control in replacement of old switch for desert cooler complete all as specified and directed by Engr-in-Charge. |
| 10 | Supply and fixing of side shutter with handle made of Galvanised MS sheet 24 Guage in replacement of as per existing size including with wood wool pad and wire mesh complete all as specified and directed by Engr-in-Charge |
| 11 | Supply and fixing of front grill of desert cooler made out of GI sheet 22 Guage in replacement including with air divesion control fins,name plate front of existing size complete all as specified and directed by Engr-in-Charge |
| 12 | Supply and fixing of bottom tank with top cover with 04 corner piece with complete frame made out of galvanised MS sheet 22 Guage in replacement for desert cooler of any capacity including dismantling and refixing of the all accessories in the unit complete all as specified and directed by Engr-in-Charge |
| 13 | Supply and fixing in replacement iron fan blade of blower motor of Desert cooler suitable for any make and capacity complete all specified and directed. |
| 14 | Supply and fixing in replacement lead wire cooler min 2 mtr complete all specified and directed. |
| 15 | Supply and fixing of new wooden wool pad of size(45X60) minimum including steel net in replacement of old pad for desert cooler of best quality as approved complete all as specified and directed by Engr-in-Charge |
| 16 | Supply and fixing new heavy duty exhaust fan motor, steel body AC single Phase in replacement of old exhaust fan motor, 1400 RPM, copper winding, 325W (MAX) of size 450mm sweep 230V/ 50Hz three/four speed with capacitor: 8.0 uF, blades,regulator and brackets of best quality complete all as specified and directed by Engr-in-Charge |
| 17 | REFRIGERATOR/DEEP FREEZERM&L,checking of Refrigerators/Deepfreezer of any make / capacity in location and position at any site in shikaargarh, HQ JOSA Jodhpur and adjoining area Jodhpur including necessary servicing ie: electrical connection /wiring, cleaning , door gasket cleaning evaporator cleaning and testing for proper functioning of refrigerators/ deep freezer all as directed by Engr-in-Charge.( The rates are deemed to be included for maintaining complete and proper record of machine ie: make with Srl No, capacity, date of servicing, user signature after servicing , concerned JEs signature all as directed by engineer incharge ) |
| 18 | Material and labour for replacement of unserviceable hermetically sealed compressor of Refrigerator / deep freezer 320 to 280 Ltr Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturer company .(ii) The new unit will be purchased from authorised dealer only as per existing make and model. |
| 19 | All as per ser item No 18 above but for 165 to 220 Ltr capacity refrigerator. |
| 20 | Material and labour for replacement of relay suitable for 280 to 320 Litres cap. Refrigerator |
| 21 | All as per ser item No 20 but cap 165 to 220 Ltrs Refrigerator |
| 22 | Material and labour of replacement of thermostat automatic defrost with knob suitable for 165 to 320 ltrs cap refrigerator |
| 23 | Material and labour for replacement of door gasket of best quality complete suitable for 280 to 320 litres cap. Refrigerator as per manufacturer's instruction and as directed by Engr-in-Charge. |
| 24 | All as per ser item No 23 above but for 165 to 220 Ltrs Cap. |
| 25 | Material and labour bulb for pin/screw type, 230 Volts suitable up to 320 Ltrs Cap. Refrigerator as in replacement |
| 26 | Material and labour for replacement of freezer door incl. necessary door springs, screws etc for 280 to 320 Ltrs Cap. Refrigerator complete all as specified and directed by Engr-in-Charge. |
| 27 | All as per ser item No 26 above but for 165 to 220 Ltrs cap. Refrigerator. |
| 28 | Material and labour for replacement of PVC chiller tray and suitable for 280 to 320 Ltrs Cap. Refrigeraator complete of matching size. |
| 29 | Material and labour for replacement of PVC chiller tray suitable for 165 to 220 ltrs capacity refrigerator complete of matching colour. |
| 30 | Material and labour for replacement of PVC Accessories suitable for refrigerator of any model/ any size, complete of matching colour. |
| 31 | Material and labour for patch work (in the outer body of refrigerator/Deep freezer with 20 gauge PGI sheet upto required length/width &hight incl necessary welding/brazing etc all as directed by Engr-in-Charge. |
| 32 | Material and labour for replacement of refrigerator door handle of 165 to 320 Ltrs Cap. of any make and model |
| 33 | Material and labour for repairing to bottom/ foundation of refrigerator any cap. With 20 gauge PGI sheet, angle iron frame made out of 25 X 25 X3 mm angle and incl necessary welding work all as directed by Engr-in-Charge |
| 34 | Material and labour for replacement of evaporator ( Freezer ) assy with door and fixing brackets complete with screw, jointing of tubes etc and testing of cap 280 to 320 Ltrs refrigerator (any make) |
| 35 | All as per ser item No 34 above but of capacity 165/180 Ltr refrigerator. |
| 36 | Material and labour for replacement of condensor unit of refrigerator cap.280 to 320 Ltrs of any make incl jointing of tubes and testing etc, complete (gas charging will be measure and paid under relevant item separately). |
| 37 | All as per ser item No 36 above but for 165 to 220 ltrs capacity refrigerator. |
| 38 | Material and labour for leakage detection including flushing out system,pressurising,including gas charging(as per existing) suitable for 286/310 ltrs refrigerator/Deep frezer Complete all as specified and directed by Engr-in- Charge |
| 39 | Material and labour for leakage detection including flushing out system,pressurising,including gas charging (as per existing ) suitable upto 220 ltrs refrigerator/Deep frezer Complete all as specified and directed by Engr-in- Charge |
| 40 | Supply and replacement of condensor fan motor complete for deep freezer cap.upto 320. In existing location and position as per sample |
| 41 | Material and labour for replacement of timer frost free refrigerator as per sample. |
| 42 | Material and labour for replacement of fan motor double door frost free refrigerator as per sample |
| 43 | Supply and replacement of PCB as per existing suitable for 220 to 320 Ltrs refrigerator/Deep Freezer |
| 44 | Supply and replacement of NRV Deep Complete all as specified and directed . |
| 45 | Supply and replacement of 3 Pin Plug Top 06 Amps ISI Marked 230 Volts |
| 46 | WATER COOLERM&L for checking of Water cooler of any make / capacity in location and position at any site in Army Area Jodhpur including necessary servicing i.e. making good electrical including copper terminal, cleaning , drain water system including replacement of hose clamp etc . complete , cleaning condensor , condenser fan motor , door gasket , cleaning storage water tank cleaning and testing for proper functioning of water cooler all as directed by Engr-in-Charge.( The rates are deemed to be included for maintaining complete and proper record of machine ie: make with srl no , capacity, date of servicing , user signature after servicing , all as directed by Engineer in-charge ) |
| 47 | Material and labour for replacement of unserviceable hermetically sealed compressor of water cooler 150 Ltr storage having cooling capacity 100 Ltrs / hour Capacity with fresh new uncut sealed unit compressor including suitable relay and over load with new sealed unit as per the company scheme supplied by the manufacturer complete including flushing out system, checking and rectfication of leakage, gas charging, complete NOTE : (i) The rate quoted by the contractor shall be inclusive of all charges ie: test certificate and necessary guarantee period as per manufacturing company (ii) The new unit will be purchased from authorised dealer only as per existing make and model. |
| 48 | All as per ser item No 47 above but for 60/120 Ltr storage capacity with cooling capacity 60 Ltrs / hour water cooler of any . |
| 49 | All as per ser item No 47 above but for 40/80 Ltr storage capacity with cooling capacity 40 Ltrs / hour water cooler of any. |
| 50 | Material and Labour for replacement of copper filter and capillary tube of water cooler cooling capacity 40 Ltr/hrs |
| 51 | Ditto All as per item no 50 above but 60 Ltr/hrs |
| 52 | Ditto All as per item no 50 above but 100 Ltr/hrs |
| 53 | Material and Labour for replacement of relay with over load protection for 40/80 Ltr/hrs cooling capacity suitable as per site requirement. |
| 54 | Ditto All as per item no 53 above but 60 Ltr/hrs |
| 55 | Ditto All as per item no 53 above but 100 Ltr/hrs |
| 56 | Material and Labour for replacement of condensor fan motor HP-1/32, RPM-1300 suitable for water cooler having cooling cap 40 Ltr/hr with clips and motor fixing stand with fan bladeISI marked. |
| 57 | Ditto All as per item no 56 above but 60 to 100 Ltr/hrs |
| 58 | Material and Labour for Repalcement of thermostat switch with knob for water cooler, having cooling capacity 40/60/150 Ltrs/hr. |
| 59 | Material and Labour for patch repair work of worn out MS body of water cooler any capacity made out of 22 gauge mild steel sheet including welding and making good with paint to match with existing all as specified and directed by Engineer-in-Charge. |
| 60 | Material and Labour for replacement of drain PVC pipe, 25 mm bore for cooling cap 40 Ltr /Hrs 90 cms in length with two Nos mild steel clamps and necessary brass screws etc. all as directed. |
| 61 | All as per item No. 60 but size 32 mm bore suitable for cooling Cap 60 to 100 Ltrs/Hrs water cooler and not more than 1.00 meter all as directed |
| 62 | Material and Labour for replacement of SS drain water tray made out of 24 gauge stainless Steel sheet of size of 30x12x5 cm deep with necessary GI screws and PVC drain water connection arrangement of size not less than 25 mm dia, all as directed (as per sample) |
| 63 | Material and Labour for replacement of water storage tank top lid complete made out of 22 gauge mild steel sheet of existing shape and size for water cooler storage cap 120 to 150 Ltrs , of appropriate thickness on one side with door gaskit including , aluminium hinges 50 mm long 2/3 nos. and making good and painting with approved colour to match the existing colour all as specified and directed. |
| 64 | All as per item No. 63 but size 80 Lts capacity |
| 65 | Material and Labour for replacement of rubber magnet gasket fixed with top cover of water cooler of 80 /120 litres storage capacity |
| 66 | All as per item No. 65 but size 150 Lts capacity |
| 67 | Material and Labour for replacement of worn out bottom base of water cooler foundation frame made out of 1.6mm thick MS sheet for water cooler, & frame work made out of angle iron 25x25x3 mm, including cutting welding brazing soldering , making holes for sealed unit , condenser with condensor fan motor , including painting black colour (two coats) synthetic enamelled paint over a coat of red oxide primer etc and finishing all as directed by Engineer-in-Charge. |
| 68 | Material and labour for replacement of water cooler body back sheet with 22 gauge mild steel sheet including suitable size(as per existing) and necessary painting, screws etc. all as specified and directed by Engineer-in-Chage |
| 69 | Material and Labour for replacement of water cooler front pannel with 20 gauge mild steel sheet including suitable size (as per existing) and necessary screws/nuts/bolts/washers etc. complete as specified and directed by Engineer-in-Charge. |
| 70 | Material and Labour for replacement of condensor fan motor mounting stand made out of mild steel sheet 3 mm thick size 400x150 mm and refixing on the existing base all as specified and directed by Engineer-in-Charge. |
| 71 | Supply and fix CP lift cock, 15mm bore made of brass self closing vertical type made of brass nickle chromium plated alongwith CP adaptor and nipple. |
| 72 | Supply and fix CP push cock, 15mm bore made of brass self closing horizontal type made of brass nickle chromium plated with CP adaptor and nipple. |
| 73 | Material and labour for painting to water cooler of storage cap. 150/120/80 Ltrs spray painting with two coats of synthetic enamelled paint (first quality) including preparation of surface complete. |
| 74 | Material and labour for repair to storage water tank of cooler of cooling cap 40 Ltr/hour by soldering / brazing to prevent leakage spots incl. cleaning of water tank and testing complete (NOTE : work is to be carried out in existing position as and where machine in army area) |
| 75 | All as per item No. 74 but size 60 Lts / Hrs capacity |
| 76 | All as per item No. 74 but size 100 to 150 Lts / Hrs capacity |
| 77 | Material and labour for replacement of starting capacitor 40-60 Mfd oil filled 240 volt AC Supply . |
| 78 | All as per item No. 77 but 60-80 Mfd |
| 79 | Material and labour for replacement of running capacitor of 15 Mfd oil filled. |
| 80 | All as per item No. 79 but 10 Mfd |
| 81 | All as per item No. 79 but 2.5 Mfd |
| 82 | Material and labour for PVC float valve 15 mm bore with PVC float, ball ISI marked complete with check nut/socket/GI nipple directed by Engineer-in-Charge. |
| 83 | Material and labour for replacement of water cooler side panel with 20 gauge MS sheet as per sample incl. necessary screws/nuts/bolts/washers etc for 40/60/150 Ltrs/hour cap all as specified and directed by Engineer-in-Charge |
| 84 | Material and labour for pressurising of system & detecting of leakages in system, flushing, replacement of copper filter and gas (using as per existing ), oil complete incl testing and commissioning of water cooler having cooling Capacity 40 to 60 Ltrs per hour of any make. |
| 85 | All as per item No. 84 but size 100 to 150 Lts / Hrs capacity |
| 86 | Material and labour for replacement of aluminium fan blade for condenser fan motor (as per sample) suitable for water cooler having cooling capacity 40 to 60 Ltr/hr water cooler |
| 87 | All as per item No. 86 but size 100 to 150 Lts / Hrs capacity |
| 88 | Material and labour for replacement of condenser unit complete suitable for 40 to 60 Ltr/hrs cap. Water cooler including gas charging flushing out the system brazing, welding and jointing the suction reed and discharge reed complete all as per direction of Engineer-in-Charge. |
| 89 | All as per item No. 88 but size 100 to 150 Lts / Hrs capacity |
| 90 | Material and labour for replacement of PVC insulated and PVC sheathed flexible cable , multistranded copper conductor 3 core 1.50 sqmm cross sectional area superior quality. |
| 91 | SPLIT/WINDOW ACMaintenance, servicing and testing of split type AC, capacity upto 1.0/1.50/2 tons, any make, by cleaning cooling coil, condenser fins, blowing of dust from machines/air filters cleaning with VINICLEAN solution using pressure jet system with water, checking and decarbonising all electric system oiling/greasing of blower motor, checking and removing any vibration and leakage in the equipment including checking/repair to inter locking device for winter/summer to ensure cutting off of compressor/heating in case of failure of blower motor including taking down and refixing in position complete all as directed by Engineer-in-Charge.Note - (I) Cost of minor repair, replacement of petty items such as nuts, bolts, washers, screws, rubber mounting pads of compressor etc is deemed to be inclusive in the unit rates quoted by the contractor. |
| 92 | Ditto All as per item No 91 above but for window AC capacity 1.5/2.0 ton complete all as specified and direced by Engr-in-Charge. |
| 93 | M&L for Servicing only of Split/Window type/Cassette ACs of any Make/ Capacity (1/1.5/ 2.0 Ton) in location and position at any site in Army Area Jodhpur including cleaning of drain water pipes, making electrical connections / wiring, etc complete all as specified and as directed by Enginner-in-charge. (The rates quoted are deemed to be included for maintaining complete and proper record of machine ie: make with cap and location , date of servicing , user signature after servicing , concerned JEs signature duly verified by the Engr- in-Charge |
| 94 | Supply and fixing in replacement of compressor hermetically sealed type equipped with suitable rated capacity electric motor and over load protection, including gas & oil charging after flushing the line with CO2 gas to avoid trapping the water vapour ensuring leak proof system complete all as specified and directed for 1.5 ton Window type/split type Air conditioners all as directed . Note: Gas charging etc shall be measured and paid separately under relevant item of schedule 'A'. |
| 95 | All as per item no 94 above but Split / Window type Airconditioner 2 ton capacity . |
| 96 | All as per item no 94 above but Rotary Screw compressor for Window / Split type Airconditioner 1.5 ton capacity . |
| 97 | All as per item no 94 above but Rotary Screw compressor for Window / Split type Airconditioner 2 ton capacity . Please Enable Macros to View BoQ information |
| 98 | All as per item no 94 above but Rotary Screw compressor for Window / Split type Airconditioner 2 ton capacity . Please Enable Macros to View BoQ information |