| 1 | Material and labour Weather proof outdoor bus bar chamber cum LT panel, made out of 3.15 mm thick MS sheet with front & rear Opening, powder coated, dust & vermin proof, IP-66 Protection comprising 4 Nos aluminium strips each of 400 Amps, 60cm long having 10cm min distance from the body, duly insulated mounted on epoxy insulators in horizontal position in stepped manner with 4 No’s mounting legs made out of 40mm x 40mm x 6mm angle iron grouted in PCC block (30cm depth below ground level and 60cm above ground level) in cement concrete 1:3:6, type C-2 (using 40mm grade crushed stone aggregate), and connections with size of aluminium thimbles, nuts, bolts & washers including cable glands at entry and outlet points with one MCCB of 250 Amps 25 KA, 4 pole as incomer of the bas bar with taking down the existing all cables, dressing the cable properly with lugs, nuts, bolts washer etc. & refixing the same including excavation and earth work, returning filling and removal of surplus soils complete all as specified and directed by Engr-in-charge. |
| 2 | Factory made LT distribution panel out door,CPRI approved, made out of 3.15 mm thick MS sheet, powder coated, dust & vermin proof, IP-66 Protection, Outdoor type factory made cubical totally enclosed type with front and rear door opening as per engineering practice provided with locking arrangement for opening of panel with provision of seperate chamber in upper part to encloser Copper busbar of cap 400 Amps fixed in steped manner on epoxy insulators in horizontal position with min 10cm distance between each busbars & panel body and 06 Nos seperate chambers of adequate size embedded in 40mm thick PCC 1:2:4 type B-1 (using 20mm graded aggregate), on angle iron of size 40x40x6mm with footing 30 cm clear space between bottom of panel and flooring including all accessories prewired with insulated copper wires of suitable size. The panel shall compromise of the following fittings and fixture :-(a) MCCB 350 Amps, 36 KA 4 pole with adjustable thermal and fixed magnetic settings - 01 No (Incoming) (b) MCCB 100 Amps, 25KA , 3 pole with adjustable thermal and fixed magnetic settings – 03 No(Outgoing) (c) MCCB 63 Amps, 25KA , 3 pole with adjustable thermal and fixed magnetic settings – 02 No (outgoing) (d) On load change over switch l-O-II,320 A,4 pole,415 V,50 Hz- 01 No (e) Indicating lamps Led type (RYB). (f) Pre-wired Digital meter with voltmeter, ammeter, selector switch, CTs, and LED Indicating Lights,. - 01 Set (g) Bus bar chamber with electrolytic grade copper strip with heat shrink cable sleeves with colour code supported on epoxy raisin based insulator 4 strips of suitable length for current rating 400 A. (h) Civil work including PCC for fixing of panel and other work as directed by Engr-in-Charge |
| 3 | S&F cable end joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size 300 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed Make: 3M/Denson or equivalent |
| 4 | S&F cable end joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size 150 to 240 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed Make: 3M/Denson or equivalent |
| 5 | S&F cable end joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size 70 to 120 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed Make: 3M/Denson or equivalent |
| 6 | S&F cable end joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size upto 50 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed Make: 3M/Denson or equivalent |
| 7 | S&F cable Straight Through joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size 300 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed Make: 3M/Denson or equivalent |
| 8 | S&F cable Straight Through joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size 150 to 240 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed Make: 3M/Denson or equivalent |
| 9 | S&F cable Straight Through joint joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size 70 to 120 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed Make: 3M/Denson or equivalent |
| 10 | S&F cable Straight Through joint joint kit \\"heat shrinkable type \\" suitable for 1.1 KV (LT) indoor/outdoor type ,for cable size upto 50 sqmm and suitable for 3 1/2 or 4 Core , complete all as specified and directed Make: 3M/Denson or equivalent |
| 11 | Supply and fixing LT Cable route indicator made up of cast iron and marked with LT and mounted on flat iron/angle iron of suitable sixe round writing LT Cable with back side welded flat iron including PCC block 30 x 30 x 20 cm complete all as directed and specified. |
| 12 | Taking out old unserviceable LT UG PVC/ XLPE cable of any size 1100 v laid in trenches/on poles through GI protection pipe NOTE: Excavattion and earthwork shall be measuured and paid for separately under respective items. |
| 13 | Supply & laying of UG cable XLPE insulated armoured heavy duty elect cable with stranded aluminium conductor 1100 volts grade cross section area 300 Sqmm 3.5 core laid in trenches/ fixing on panels/walls/poles or passing through pipe including connecting with suitable lugs, glands, nuts and bolts and testing complete all as specified and directed. NOTE: Excavation and earth work shall be measuured and paid for separately under respective items . |
| 14 | All as per item no 13 here-in-beforee but size 185 Sqmm 3.5 core. |
| 15 | All as per item no 13 here-in-beforee but size 150 Sqmm 3.5 core . |
| 16 | All as per item no 13 here-in-beforee but size 120 Sqmm 3.5 core . |
| 17 | All as per item no 13 here-in-beforee but size 95 Sqmm 3.5 core . |
| 18 | All as per item no 13 here-in-beforee but size 50 Sqmm 3.5 core. |
| 19 | Excavation in trenches in hard/dense soil not exceeding 1.5 meter wide and not exceeding 1.5M in depth for laying of cables and getting out of excavated material complete all as specified and directed by Engineer-in-Charge. |
| 20 | Material and labour for sand cushioning below and around cable in trenches with rever sand all as specified . |
| 21 | M&L for un-reinforced precast concrete cable cover, class LV, type 1, flat of size 250 x 150 x 40 mm for cable protection complete all as specified and as directed by EIC |
| 22 | Returning, filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25cm thick each, excavated soil in trenches after the cables have been laid and tested complete all as specified and directed by Engineer-in-Charge. |
| 23 | Removing excavated soil to a distance not exceeding 50 meter and depositing where directed at a level not exceeding 1.50 meter above the starting point complete all as specified and directed by Engineer-in-Charge. |
| 24 | Material & labour for cutting existing road/Hard Rock/ PCC hard Standing/ pavement/ drain for taking out / laying of undergroung water pipe/ cable passing through suitable size of GI Pipe line and including necessary earth work and making good to match with the existing surface with PCC work in type B2 (1:2:4) cement mortar with 40mm graded aggregate complete all as specified and as directed by Engineer-in-charge. |
| 25 | M&L for Mild steel galvanized tubes light grade ISI marked 100 mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge. |
| 26 | M&L for Mild steel galvanized tubes light grade ISI marked 80 mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge. |
| 27 | M&L for Mild steel galvanized tubes light grade ISI marked 50mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |
| 28 | M&L for Mild steel galvanized tubes light grade ISI marked 50mm bore laid in trenches / road crossing/ fixed to pole /walls/path/drain /floor etc in and including taking down old unservicable G I pipe ,compllete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |