| 1 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for laying pipes in trenches/rectification of leakages and getting out in soft/loose soil complete all as specified and as directed. |
| 2 | Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exe 25 cm complete all as specified and as directed. |
| 3 | Removing excavated soil n exc 50 M and depositing where directed at level n.exc 1.5 M above the starting point complete all as specified and as directed. |
| 4 | Taking out the sluice valve steel spindle and refacing, re-grinding and refixing of the following size after cleaning dust, greasing etc |
| 5 | 80mm dia |
| 6 | 100mm dia |
| 7 | 150mm dia |
| 8 | 200mm dia |
| 9 | Supply and fix in replacement of centric butterfly valves wafer Type PN 1.6 as per BS-5155 &IS-13095 lever operated body grey cast iron disc -SGI Epoxy coated Disc seal-Nitrile/Epdm in gear operated of following sizes confirming to IS specification all as specified including taking down unserviœable accessories all as specified and as directed. |
| 10 | 150 mm dia |
| 11 | 100 mm dia |
| 12 | Supply and replace worn out / rusted nut, bolts and washer in repairs of any size wherever necessary all as specified and as directed. |
| 13 | Supply and fix in replacement of old unserviceable MS pipe IS-1239 marked (heavy duty) exposed in multistoried building including all fittings like coupling, bends, elbows, tees etc. and suitable fixing arrangement for pipe support such as MS round, angles, channels, plate including cutting to size welding complete including painting the whole surfaœs of MS pipe with synthetic enamel paint as per colour code over two coats of zinc chrome primer all as specified and as directed. |
| 14 | 80 mm dia |
| 15 | 100 mm dia |
| 16 | 150 mm dia |
| 17 | Material and labour for cutting existing CI pipe/MS pipes in position for rectification of leakages/replacment of unserivceable pipes of the following sizesNote : The new pipes/Joints will be measured and paid seperately. |
| 18 | 80 mm dia |
| 19 | 100 mm dia |
| 20 | 150 mm dia |
| 21 | Material and labour for replacement of 150mm MJ Collar with nut and bolt including taking out old unserviceable collar Note : Earthwork & cutting of pipes measured seperately. |
| 22 | Supply and fix in replacement of old unserviceable Cl specials such as bends (any type,radius,and angle) tapers any type (straight, bend, or double sockets etc) Tee pieces,singIe branch 'Y' junction, double branch (all sockets or socket and spigot) cross,coIIars caps and plugs etc upto 150mm bore, complete all as specified and as directed. |
| 23 | Supply and fix in replacement of 63 mm dia gun metal branch pipe with nozzle conforming to IS 903 including taking down unserviceable, complete all as specified and as directed. |
| 24 | Supply and fix in replacement of gun metal fire Hydrant valve with 5 mm flanged inlet and 63 mm female single headed instantaneous outlet complete with Lug & Chain as per IS-5290 hydrostatically tested to 21 Kgf/cm2 of pressure having a flow rate of 900 LPM at 7Kgf/m2 including taking down unserviceable complete all as specified and as directed. |
| 25 | Supply and fix in replacement of 20mm Gun metal gate valves with iron wheel head screwed both ends for iron pipe, confirming to IS specification all as specified including taking out the unserviceable complete all as specified and as directed. |
| 26 | Supply and fix in replacement of Fire brigade inlet connection 4 way complete with Lug & Chain as per IS 5290 Hydrostatically tested to 21 Kgf/cm2 of pressure having a flow rate of 900 LPM at 7Kgf/m2 all as specified and as directed. |
| 27 | Supply and fix in replacement of fire hose 63 mm dia confirming to IS:636, 15 meter length including gunmetal heavy duty pair of male and female couplings all as specified and as directed. |
| 28 | Supply and fix in replacement of sluice valve, non rising spindle flanged end of class PN 1.6 with stainless steel spindle with all accessories suitable for size 80mm dia confirming to IS specfication all as specified including taking out the unserviceable. |
| 29 | All as per item No.16 here-in above but of size 100 mm dia |
| 30 | All as per item No.16 here-in above but of size 150 mm dia |
| 31 | Supply and fix in replacment of Automatic air release valve 25mm dia threaded type including taking down old u/s complete all as specified and as directed. |
| 32 | Hacking out old broken glass (any thickness, size, quality or description) from metal frame including punching or drilling out old glazing pins / spring clips / removing beads etc, including making good breakages in taking out and providing for fixing of new one all as specified and as directed. |
| 33 | Material and labour for Sheet glass of size 5.5mm thick, ordinary quality and glazing complete with rubber gasket including cutting of Per SM glass in oval shape of size not exceeding 0.5SQM each all as specified and as directed. |
| 34 | Painting fire hydrant pipe line up to 150/100/80mm dia by scrapping old rusted paint and applying one coat of red oxide primer and two coats of synthetic enamel paint of fire red colour including marking fire hydrant flow, all as specified and as directed. |
| 35 | Material and labour cleaning of fire static tanks capacity 100kL & 50 kL at Navjivani Hospital by draining out the brackish / muddy water and applying bleaching powder in the bottom, side wall by and scrubbing and removing scale dirt and fungus with steel wire brush and one coat of white wash complete including writing date of cleaning with white paint all as directed. |
| 36 | Supply and fix in repair GI fire buckets 04 Nos of thickness 1mm & 9 Ltrs capacity duly filled with cleaned sand and water (02 Nos bucket filled with water & 02 Nos bucket filled with sand) along with suitable fire stand with angle Iron of size 40x40x5 mm and roof should be GI sheet of 1 mm thick & also suitable space for 03 Nos Fire extingushers including complete painting with super enamled paint red coulor and write FIRE on Roof top of stand, all as specified and as directed.Note : Rate of Fire extingushers not included |
| 37 | Material and labour for servicing of diesel engine driven high pressure fire pump of following capacity at fire pump houses at INA Ezhimala by servicing all accessories PT pump injectors, wood ward governor, Self Starter, Radiator, dynamo, engine wiring, terminal contacts and safety controle etc. including replacement of complete OiI, OiI FiIter, Fuel Filter, bypass filter, Air filter, Coolant, Suitable fan belts etc and reassembling the sub assemblies after carrying out neœssary repairs and paint with one coat of enamel paint commissioning and testing as directed. Make : Kirloskar |
| 38 | 108BHP capacity Diesel engine |
| 39 | 38 BHP capacity Diesel engine |
| 40 | 77 BHP capacity Diesel engine |
| 41 | Supply and fix in replacement battery charger type CVCC output 24V, 10A DC suitable for diesel engine pump all as specified and as directed. |
| 42 | Material and labour for hydraulic pressure testing and refilling fire extinguisher including repair/ replacement of worn out parts such as line valve, check nuts, and hose with nozzle wherever required for proper functioning of extinguisher for following type and capacity all as specified and as directed. |
| 43 | DCP stored pressure - 9 kg capacity |
| 44 | CO2 - 4.5Kg capacity |
| 45 | AFFF foam - 9 liters capacity |
| 46 | Material and labour for rewinding of electric motor of following capacity and including following services complete all as specified and directed by the Engr-in-charge. (a) Disconnecting the electrical cable from the terminal box of motor and decoupling the motor from the pump, remove the motor from foundation bed and lifting the motor using chain pulley block and transporting to authorised work shop.(b) Dismantling the motor stator and taking out the burnt copper winding wire /fibre strip/insulating materials.(c) Clean the stator slots by CTC solution and rewind on stator slots with duel coat super enamelled copper wire of existing gauge with insulating materials/fibre strip/varnishing and made terminal connection using 90 mm fibre glass coated wire.(d) Assembling the motor after rewinding.(e) Transporting to the motor to the site re-fixing on foundation channel, coupling the pump and motor with correct alignment apply grease and connecting electrical connections and testing. |
| 47 | 100HP/74KW |
| 48 | 40HP/30KW |
| 49 | Material and labour for rewinding of 3 Phase, monoblock pumpset of 15 HP capacity including following services(a) Disconnection of electric cable from the terminal box of pump set. remove the pump set from the foundation bed and transport to authorised work shop.(b) Decoupling the motor stator from pump set and taking out the burnt copper winding /fibre strip/insulating materials(c) Clean the stator slots by CTC solution and rewind on stator slots with super enamelled copper wire of existing gauge with insulating materials/fibre strip/varnishing and made terminal connection of fibre glass coated wire.(d) Re-assembling the pump set after stator rewinding and replacement of gland rope (e) Transporting the pump set to the site re-fixing on foundation channel, apply grease and connecting electrical connections and testing |
| 50 | Supply and fix in repair dial type pressure gauge (4\\"Dia)(Firebug) 0-16 bar including taking down old unserviceable item all as specified and as directed. |
| 51 | Supply and fix in repair Single pressure switch, universal type to suit the system including taking down old unserviceable item all as specified and as directed. |
| 52 | Material and labour for painting of fire yard control cabinet out door type size 0.5 x 0.5 x 0.3 meter with two coats of paint over a coat red oxide primer by spray paint including scrapping out old rusted paint and necessary snickering and making all as directed all as specified and as directed. |
| 53 | Supply and replace rubber bush for pump coupling suitable for the following capacity of pumps |
| 54 | 75KW/100HP motor |
| 55 | 15HP/11KW motor |
| 56 | Material and labour for repairs to valve chamber of size upto 1.2x1.2x1.2m by dismantling the broken angle iron & MS plate cover and complete by welding with new hinges, locking arrangements etc. refixing the MS plate on PCC and including necessary brick work , replacement of angle iron of 50x50mm for support and cement plastering, painting steel surfaces with two coats of synthetic enamel paint of tint and one coat of white wash on cement surfaces, all as specified and as directed. |
| 57 | Supply and fix in replacement of old u/s 3 pole power contactor AC 1 rating 160 Amps and AC3 rating 140 Amps Aux contacts 2 NO+2NC range from 9A-650 A, 220V coil voltage ,including taking down the existing unserviceable material all as specified and as directed. |
| 58 | Supply and fix in replacement of old u/s 3 pole power contactor, AC 1 rating 100 Amps and AC3 rating 70 Amps Aux contacts 2 NO+2NC range from 9A-650 A, 220V coil voltage ,including taking down the existing unserviceable material complete all as specified and as directed. |
| 59 | Supply and fix in replacement of old u/s 3 pole power contactor, AC 1 rating 45 Amps and AC3 rating 25 Amps Aux contacts 1 NO+2NC range from 9A-25 A, 220V coil voltage ,including taking down the existing unserviceable material complete all as specified and as directed. |
| 60 | Supply and fix in replacement of old u/s electronic star Delta timer, wide operating voltage 160-500V, 50 Hz available in time delay range3-30sec and 12-120 secs including taking down old material complete all as specified and as directed. |
| 61 | Supply and fix in repair MCCB 4pole 36KA of capacity 160A with thermal Adjustable type all as specified and as directed. |
| 62 | Supply and fix in repair MCB 3pole 10KA of capacity 25 to 63A all as specified and as directed. |
| 63 | Supply and fix in repair MCB 2 pole 10KA of capacity 6 to 32A all as specified and as directed. |
| 64 | Material and labour cleaning of fire static tank of capacity 225KL (at Kautilya Fire Pump House) by draining out the brackish / muddy water and applying bleaching powder in the bottom, side wall by and scrubbing and removing scale dirt and fungus with steel wire brush, cleaning two times with fresh water and one coat of white wash complete including writing date of cleaning with white paint all as specified and as directed. |
| 65 | Supply and fix in replacement of Non Return Valve of size 100 mm dia including taking down unserivceable complete all as specified and as directed. |
| 66 | Supply and fix in repairs Non Return Valve of size 150 mm dia including taking down unserivceable complete all as specified and as directed. |
| 67 | Supply and fix in replacement of Foot Valve 150 mm dia including taking down unserivceable complete all as specified and as directed. |
| 68 | Supply and fix in replaœment of Foot Valve 100 mm dia including taking down unseñvceable complete all as specified and as directed. |
| 69 | Supply and fix in replacement of old unservisable Hose box made of 18 gauge MS Sheet 800mm X 600mm X 250mm with double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side and brilliant white inside yard complete all as specified and as directed. |
| 70 | Painting of Valve chamber by two coats of synthetic enamel paint of existing colour on MS cover, hinges, angles and one coat of white wash on outside and inside chamber including scrapping out old rusted paint complete all as specified and as directed. |
| 71 | Material and labour for rewinding of 3 Phase, Air blower motor 3 HP capacity including following services(a) Disconnection of electric cable from the terminal box of pump set. remove the pump set from the foundation bed and transport to authorised work shop.(b) Decoupling the motor stator from pump set and taking out the burnt copper winding /fibre strip/insulating materials(c) Clean the stator slots by CTC solution and rewind on stator slots with super enamelled copper wire of existing gauge with insulating materials/fibre strip/varnishing and made terminal connection of fibre glass coated wire.(d) Re-assembling the pump set after stator rewinding and replacement of gland rope (e) Transporting the pump set to the site re-fixing on foundation channel, apply grease and connecting electrical connections and testing Please Enable Macros to View BoQ information |
| 72 | Material and labour for rewinding of 3 Phase, Air blower motor 3 HP capacity including following services(a) Disconnection of electric cable from the terminal box of pump set. remove the pump set from the foundation bed and transport to authorised work shop.(b) Decoupling the motor stator from pump set and taking out the burnt copper winding /fibre strip/insulating materials(c) Clean the stator slots by CTC solution and rewind on stator slots with super enamelled copper wire of existing gauge with insulating materials/fibre strip/varnishing and made terminal connection of fibre glass coated wire.(d) Re-assembling the pump set after stator rewinding and replacement of gland rope (e) Transporting the pump set to the site re-fixing on foundation channel, apply grease and connecting electrical connections and testing Please Enable Macros to View BoQ information |