| 1 | Wiring point for light with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm. FRLSH PVC insulated multistrand copper conductorcable as earthwire drawn inside,GP Box, piano type switch & ceiling rose/angle/batten holder on 3mm thick phenolic paminated backalite sheet etc complete in all respect as directed including matching colour wash. PS No. 138(C) |
| 2 | b) Add for Light Modular type switch in place of piano type switch. PS No. 187A |
| 3 | Wiring point for fan / fresh air fan (light duty exhaust fan) with 1.5 sq.mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement beforeconcreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. ,GP Box , piano type switch & ceiling rose on 3 mm. thick backelite sheet etc., complete in all respect including matching colour wash. PS No. 140(C) |
| 4 | b) Add for Fan Modular type switch in place of piano type switch. PS No. 187A |
| 5 | Wiring point for plug with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. and piano type switch and socket etc., complete in all respect including matching colour wash. PS No. 141(C) |
| 6 | b) Add for Plug point with Modular switch & Socket in place of piano type switch&Socket. PS No. 187C |
| 7 | Wiring point for two ways light with 1.5 sq. mm. F.R. PVC insulated multistrand single core copper conductor cable in PVC conduit pipe partly concealed in the wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit , GP Box and two number two way piano type switches & ceiling rose / angle / batten holder on 3 mm thick phanolic laminated backelite sheet etc., complete in all respect, as directed, including matching colour wash. .P.S. No- 139(C) |
| 8 | b) Add for two way light point Modular switches in place of piano type switches. PS No. 187B |
| 9 | Wiring point for call bell with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. GP Box and piano type bell push or 2 pin socket etc, complete in all respect including matching colour wash. P.S. No-142(C) |
| 10 | b) Add for Call Bell point Modular type bell push in place of piano type switches. PS No. 187E |
| 11 | Supply and fixing of power plug with 20 Amp./250 volt flush type modular switch and 5 pin 20 A/250 volt flush type universal modular socket switch on concealed M.S box including supply of all material, labour T&P etc. required for proper completion of workPS No. 1139(A) |
| 12 | Wiring point for H.P.M.V./ Sodium Vapour lamp with 1.5 sq. mm.FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit partly concealed in wall and partly laid in slab alongwith the reinforcement before concreting, complete with 1.5 sq. mm.FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. and 15 A piano type switch etc.,complete in all respect including matching colour wash.. PS.No. 143C |
| 13 | b) Add for HPMV/Exhaust fan point with modular type switch in place of piano type switch. PS No. 187D |
| 14 | Supply and wiring of submain with two number 4 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with one no. 2.5 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. including matching colour wash etc. complete in all respect. P.S. No- 221 (C) |
| 15 | Supply and wiring of submain with two number 6 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core aluminium conductor cable in 25 mm dia heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with one number 4 sq. mm. FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. including matching colour wash etc. complete in all respect. PS No. 222 (C) |
| 16 | Supply and wiring of 4 number 10 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in heavy duty (2 mm thick) PVC conduit partly concealed in wall and partly laid in slab alongwith reinforcement before concreting, with 2 nos 6 sq.mm. FRLSH PVC insulated copper conductor cable as earth continuity wire drawn in conduit. including matching colour wash etc, complete in all respect. PS No. 278(C) |
| 17 | Supply and wiring of submain with two number 2.5 sq.mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit partly laid in slab alongwith reinforcement before concreting and partly concealed in wall, with 1 nos. 1.5 sq. mm. FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduit complete in all respect. etc, complete in all respects including matching colour wash. PS No. 1307(C) |
| 18 | Supply and wiring of submain with two number 10sq.mm.FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 25 mm dia heavy Duty (2 mm thick) PVC conduit partly concealed in wall & partly laid in slab along with reinforcement before concreting, with one number 6 sqmm FRLSH PVC Insulated multistrand single core copper conductor cale as earth continuity wire drawn inside the conduit complete in all respect. PS No. 223(C) |
| 19 | S&F of 6 Amp to 32 Amp. SPMCB (10 KA) C Curve PS No. 1002 CAT-A |
| 20 | S&F of 40 Amp 4 pole MCB (10 KA) PS No. 1020CAT-A |
| 21 | S&F single pole MCB blanking plate PS No. 1034(B) CAT-A |
| 22 | S & F sheet steel enclosure surface/Flush mounting fitted with 20Amp. 2Pin and earth metal clad scraping earth plug and socket complete in all respect. as directed at site by Engineer in charge. PS No. 1031 CAT-A |
| 23 | S & F surface/Flush mounting 6ways TPN distribution board without additional board without MCB complete in all respect, as directed at site by Engineer in charge. PS No. 1027 CAT-A |
| 24 | S & F surface/Flush mounting 4ways TPN distribution board with additional metal door without MCB complete in all respect,as directed at site by Engineer in charge. PS No. 1026 (A) CAT-A |
| 25 | S&F of 100 Amp 4 pole MCCB (25 KA) Thermal Magnetic release PS.No. 1021 C CAT-A |
| 26 | Supply and fixing of LED Tube Light batten fitting suitable for up to 1 X 22 watt LED tube light on surface complete in all respect. PS.No. 1413 A CAT-AAA |
| 27 | Supply and fixing of water tight oblong 10 Watt LED bulkhead luminaire with driver set confirming to IP 65 and above Protection . complete in all respect. P.S. No-1417 CAT-AAA |
| 28 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB's (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB's shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. |
| 29 | The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheetwith a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only. Incoming 100 Amp MCCB -1 NoOutgoning a) 63 Amp. MCCB-2 Nos. Cat. B. Pannel Cubicle Type PS No. 811 |
| 30 | S/Laying of Aluminium conductor PVC insulated armoured, served, sheathed cable 1100 V grade at a depth of 75 cm. below GL over a cushion of 75 mm. thick sand alround & protected with bricks on sides on top. On surface the cable run shall be fixed on M.S. Clamps of and T&P required for proper completion of the work. P.S. No. 501 (Gloster/Polycab/Havell's make) a)70 Sq.mm. 3½ Core |
| 31 | b)-16 sq.mm x 4 core |
| 32 | S/F of palm or pin type cooper tin plated cable socket (Lug) to the cable leads insulating with tape and making connection etc. Complete in all respects as per direction of E/I (PS No. 504)a) 70 sq.mm |
| 33 | b) 16 sq.mm |
| 34 | Supplying and laying of following size DWC HDPE pipe ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc. in the existing trench, complete as required. a)-63 mm dia (OD-63 mm & ID-51 mm nominal) DSR 2018 I.No. 14.15.1 |
| 35 | b)-90 mm dia (OD-90 mm & ID-76 mm nominal) DSR 2018 I.No. 14.15.2 |
| 36 | S/Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect. . PS No. 1422 Cat AAA |
| 37 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. P.S. 725B |
| 38 | S/L of 25x3 mm. G.I. Strip from earth electrode directly in the ground as required complete in all respects (P.S. No. 716) |
| 39 | S/F of Call bell of approve make on polished MDFEG/Teak ply board incl. making connections etc. compllete in all respects. PS No. 1101 |
| 40 | Supply and fixing of electronic fan regulator( Modular) 120-280 V. ISI marked, on the existing switch board including making connections, required material, labour T&P etc. for proper completion of work to the satisfaction of Engineer in charge of work. PS No. 1203(C) |
| 41 | Making hole in the wall for exhaust fan and finishingproperly complete in all respect.. PS No. 1121 |
| 42 | Supply and Fixing and concealing of PVC Conduit pipe with ISI mark embossed and with PVC accessories confirming to IS No. 3419 for drawing wires duly sealed at joints with original resin/adhesive to make the complete piping rigid. Plastering with cement sand mortar finished to the level with matching colour wash including cost of all material labour and T&P etc. requied for proper completion of the work as per directions and to the satisfaction of Engineer in Charge a) 20 mm dia PVC Conduit (2 mm thick) P.S. No- 148(A) |
| 43 | b)25 mm dia PVC Conduit (2 mm thick) P.S. No- 149(A) |
| 44 | c) 32 mm dia PVC Conduit (2 mm thick) P.S. No- 150(A) |
| 45 | Supply and fixing of batten / angle holder complete in all respect. PS No-405 |
| 46 | Supply & Fixing of Battery 12 V PM 20000 Prestolite/Exide/Amaron make .Complete in all respect as per direction of E/I. |
| 47 | Supply & Fixing of 10 KVA UPS . Complete in all respect as per direction of E/I. |
| 48 | Supply, Installation, Testing and commissioning of 1.5 Tr. Split type 3 star non-inverter air cooled A.C. unit consisting outdoor unit, indoor unit as detailed complete with standard factory supplied power and control coble, interconnection copper refrigerant piping insulated with insulation tubing as required as direction of E/I. (AOR) |
| 49 | Supply and fixing of Copper pipe insulating PVC Coated. Complete in all respects as per direction of E/I. (AOR) |
| 50 | Supply and laying of 2.5 sqmm x 3 core PVC Insulated Copper Cable. Complete in all respects as per direction of E/I. (AOR) |
| 51 | Supply, Installetion, Testing & Commissioning of 450 mm dia 1400 R.P.M Exhaust fan with lovuvred shutters (AOR) |
| 52 | Supply, Installetion, Testing & Commissioning of 300 mm dia 900 R.P.M Exhaust fan with lovuvred shutters (AOR) |
| 53 | Supply of ceiling fan 1200 mm dia (ISI Mark) Make- Crompton/Havells/Bajaj /Usha or equivalent (AOR) |
| 54 | Supply of ceiling fan 1400 mm dia (ISI Mark) Make- Crompton/Havells/Bajaj/ Usha or equivalent (AOR) |
| 55 | Supply of ceiling fan 900 mm dia (ISI Mark) Make- Crompton/Havells/Bajaj/ Usha or equivalent (AOR) |
| 56 | Supply of 400 mm dia (ISI Mark) decorative type bracket fan. Make- Crompton/Havells/Bajaj/Usha or equivalent (AOR) |
| 57 | Supply and fixing of C02 type fire extinguisher 4.5 kg. capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. PS No. 1132 |
| 58 | S/F of fire bucket, round bottom made of GI sheet 9-11 liters capacity duly painted as per fire brigade design, supported on hanging bracket, chained & locked initially filled with fine river sand, water as per direction of E/I. P.S. No. 1133 |
| 59 | S/F of shock treatment chart (Prescribed under I.E. Rules) duly framed with glass & supported from back with hard board or soft board with supply of all material labour and T&P for proper completion of work. P.S. No. 1134 |
| 60 | S/L of 1800x900x12 mm. thick chequered rubber matting of testing quality. P.S. No. 1136 |
| 61 | Supply and fixing of recess/ Surface/ Pendent mounting round 6 Watt 8 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. PS No. 1401 Cat AA |
| 62 | Supply and fixing of recess/ Surface/ Pendent mounting round 10 Watt 15 Watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/ Reflector and driver set complete in all respect. PS No. 1402 Cat AA |
| 63 | Supply and fixing of fan hook fabricated from M.S. rod for ceiling fan each. PS No. 1123 |
| 64 | Supply and fixing of fire extinguisher, ABC Type 9.00 kg. capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper completion of work. PS No. 1131 (B) |
| 65 | Supply and fixing hexagonal/Round G.P.fan box of approved make made up of 1.0 mm thick ISI Marked G.P.sheet spot welded Four to Eight holes of 25.4 mm for pipe entry of the box. Holes should be semi-shuttered type with 0.5 mm G.P. Sheet made upper & lower cover duly screwed fitted with 300 mm round zink coted M.S Bar X 12 mm & brand name should be embossed. Fixing with wiring conduit laid in the R.C.C. roof before concreting alongwith supply of all material, labour, T&P etc. required for proper completion of the work. PS No. 1149 |
| 66 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect. PS. No. 807 f (ii) 40 A TPN |
| 67 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. PS No 647 |
| 68 | Supply of Sheet Moulded Compound and Thermoplatic LT Distribution box of size 450x350x200mm, for 3 Phase Out door connection to LT Line consumers through overhead ABC Line, Shockproof, rust proof, termite proof, vermin proof, self extinguished, Complete with provision of 3 phase aluminium bus bars of EC grade of size 25x6x300mm long and neutral bus bar of size 40x6x300mm. It will be with coloured sleeves on each busbar, the same will be with facility of cable termination having i incoming and 4 outgoing with 4 polymeric glands of 25mm dia and 6 Nos rubber gurmuts on each side. (AOR) |
| 69 | Supply and fixing of XLPE insulated Al. unarmoured cable for working voltage for energizing the distribution boxes & street light size 1x16sqmm complete in all respects as per direction of E/I. (AOR) |
| 70 | Supply and fixing of XLPE insulated Al. unarmoured cable for working voltage for energizing the distribution boxes & street light size 1x25 sqmm complete in all respects as per direction of E/I. (AOR) |
| 71 | Supply & erection of \\"D\\" clamps of 50 mm x 6mm flat iron on steel tubular poles / steel rail poles with bolts, nuts etc. complete in all respects including painting with aluminium paint PS No. 623 |
| 72 | Supply & fixing of 75 mm x 90 mm shackle insulator /100 mm x 65 mm pin insulator including G.I. Bolts / spindle nuts etc. complete in all respect. . P.S. No.620 |
| 73 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting of fluorescent / HPMV / HPSV street light fitting on pole including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. (DSR Electrical-2018/I No. 12.34) |
| 74 | Supply and laying 90 mm dia DWC ( Double wall corrugated pipe across the road by Trenchless method (Manual). Complete in all respect as per direction of E/I. (AOR) |
| 75 | Supply & fixing of 16 mtr High mast shaft of approvedmake with rising system hot dip glavanized inside & outside dip,heaving pole sheet thickness 3 mm. Top diaminium 150 mm, Bottom dia 360 mm base plate 32 mmthick suitable for wind velocity as per IS 875 part 3 & having no circumferential weld, with accessories forhigh mast such as head frame suitable for 6 to 12luminaries & its control gear boxes 1.5 HP ower toolmoter, 3 point suspension system with steel wire rope 6mm dia, double drum winch, including making suitablefoundation as per manufature drawing/ site reuimentalong with foundation bolts nuts, washers, anchor plates etc completee in all respect. PS No. 652 (Make : Bajaj/Philips/Crompton/Valmont/ Transrail) |
| 76 | Supply and Fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 175 to 200 Watt. Confirming to IP 66 Protection complete in all respects. PS No. 1425 (A) Cat AA (Bajaj/Philps/Havells/Crompton) 5 years warranty |
| 77 | Providing and fixing of G.I. Chain Link fabric fencing of required width size50x50mm including strengthening with 2mm dia wire or nuts, bolts and washers as required Complete as per the direction of Engineer-in-charge. Made of G.I. Wire of dia 4mm PVC Coated to achieve outer dia not less 5mm in required colour and shade. Complete in all respect as per direction of E/I.(AOR) |
| 78 | Supply and fixing of 36 Watt to 46 Watt indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing body with extended heat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. PS No. 1406 Cat A |
| 79 | Demolishing Cement Concrete manually by mechanical means including disposal of material within 50 mtr lead as per direction of Engineer-in-Charge, Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) DSR Civil 15.2.1 (AOR) |
| 80 | Cement Concrete with 2 cm gauge approved stone ballast, coarse sand & cement in the proportion of 4:2:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.07/S.N. 279 |
| 81 | Cement Concrete with 4cm gauge approved stone ballast, coarse sand & cement in the proportion of 8:4:1 including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. (SOR, UPLNV, I.No. 5.08/S.N. 281 |
| 82 | Taking out existing c.c. interlocking paver blocks from foothpath/central verge, including removal of rubbish etc. disposal of unserviceable material to the dumping ground, for which payment shall be made seperately and stacking off serviceable material withing 50 mtr lead as per direction of E/I (AOR) |
| 83 | Laying Old cemennt concrete interlocking paver blocks of any design/shape laid in required line, level currative colour and pattern over and including 50mm thick compacted bed of course sand filling the joint with fine sand etc. all complete as per direction of E/I (Old CC Paver block shall be supplied by the deptt free of cost) (AOR) |
| 84 | Steel work welded in built up sections/ framed work including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. required .(AOR) Please Enable Macros to View BoQ information |