| 1 | Electrical |
| 2 | OD17219/2026-2027:Supply,conveyance, installation testing and commissioning of wall mounting 2 Ton 3 Star Inverter Split AC, Copper, 2 Ton 3 Star Split Inverter with Filter Copper Condenser unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply, filled with R-410 A /R32 refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like ling,dehumidifying, air circulating, filtering etc of following capacity including refrigerant copper piping 3m with sulation,control cable up to 5m, 3 m drain pipe, condenser stand, microprocessor control with cordless remote control, base frame etc. with one year warranty for machine and one year 4 Nos free service. 2 Ton single phase 3 Star rated Invertor Split copper convertable Ac unit (O General/Blue star/Carrier/ Samsung/Panasonic/Daikin make etc as required. |
| 3 | OD17215/2026-2027:Supply,conveyance, installation testing and commissioning of wall mounting 1.5 Ton 3 Star Inverter Split AC, Copper, Flexicool Convertible 6-in-1 Cooling 1.5 Ton 3 Star Split Inverter Dual Filtration with HD & Auto Cleanser AC with PM 2.5 Filter - White Copper Condenser) unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply, filled with R-410 A /R32 refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like ling,dehumidifying, air circulating, filtering etc of following capacity including refrigerant copper piping 3m with sulation,control cable up to 5m, 3 m drain pipe, condenser stand, microprocessor control with cordless remote control, base frame etc. with one year warranty for machine and one year 4 Nos free service. 1.5 Ton single phase 3 Star rated Invertor Split copper convertable Ac unit (O General/Blue star/Carrier/ Samsung/Panasonic/Daikin make etc as required. |
| 4 | OD18231/2026-2027:Supply, installation testing and commissioning of wall mounting 3 star 1Tr Inverter split air conditioner copper unit of the following ratings conforming to relevant IS suitable for operating on 230V, 50Hz single phase AC supply, filled with R-410 A /R32 refrigerant gas, high energy efficient, RoHS complaint, capable of performing functions like ling,dehumidifying, air circulating, filtering etc of following capacity including refrigerant copper piping 3m with insulation,control cable up to 5m, 3 m drain pipe, condenser stand, microprocessor control with cordless remote control, etc. with comprehensive maintenance contract up to the end of 36 months from date of commissioning including periodical services, gas topping etc (O General/Blue star/Carrier/ Samsung/Panasonic/Daikin make etc as required) |
| 5 | OD17220/2026-2027:Supply and fixing 4 KVA voltage stabilizer V guard or equivalent with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cut off) time delay, indicators,and chord wire etc.as required |
| 6 | OD17216/2026-2027:Supply and fixing 5 KVA voltage stabilizer V guard or equivalent with input voltage 170 to 270 V and output voltage range of 210 to 230 V with overload protection (cut off) time delay, indicators,and chord wire etc.as required. |
| 7 | OD17224/2026-2027:Supply and providing frame for the outdoor unit for 1 TR/ 1.5TR / 2 TR high wall split ACunit |
| 8 | 1.27.1:Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc as required.1 or 2 Module (75mmX75mm) |
| 9 | 90.10.1.2:Supply & Fixing the following types/ sizes of boxes suitable for modular accessories in surface/ recess including making good the damages, colour washing etc as required (RoHS compliant )2 module moulded plastic box on surface |
| 10 | 90.10.3.15:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )32A DP switch with indicator |
| 11 | 1.24.5:Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 12 | 90.10.3.23:Supply and Fixing the following modular switches & accessories in the existing front plates and giving necessary connections as required (RoHS compliant )16A 3 pin plug top |
| 13 | 1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 14 | 1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm |
| 15 | 1.17.21:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 4 sq. mm |
| 16 | 1.17.24:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.6 x 4 sq. mm |
| 17 | 90.11.1.14:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - double cover TPN vertical DB with provision for fixing 4P MCB / Isolator/ RCCB/ RCBO as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 18 | 90.11.1.19:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+12) - double cover TPN vertical DB with provision for fixing MCCB as incomer and SP/ TP MCB as outgoing (IP 42/43) |
| 19 | 90.14.10.1:Supply, conveyance and fixing the following types & current rated control gears & switchgears conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required.16 A-100A, 16 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL |
| 20 | 2.13.2:Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 21 | 2.15.3:Supplying and fixing following rating, four pole, (three phase and neutral), 415volts, residual current circuit breaker (RCCB), having a sensitivity current 30milli Amperes in the existing MCB DB complete with connections, testing andcommissioning etc. as required.63 amps |
| 22 | 2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Single pole |
| 23 | 2.10.4:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, \\"\\"C\\"\\" curve, miniaturecircuit breaker suitable for inductive load of following poles in the existing MCBDB complete with connections, testing and commissioning etc. as required.Triple pole |
| 24 | 2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 25 | OD17225/2026-2027:Supplying and fixing following rating, Triple pole, 415 volts, MCB in the existing Panel complete with connections, testing and commissioning etc. as required. 63A TP MCB |
| 26 | 90.12.7.42:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.4 core 25 sq mm with factory made clamp |
| 27 | 90.12.7.30:Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade of the following sizes using clamps noted along with the cables, spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.3.5 core 70 sq mm |
| 28 | 9.1.34:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 25 sq. mm (28mm) |
| 29 | 9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm) |
| 30 | 2.1.3:Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required.100 Amp TP&N |
| 31 | OD17516/2026-2027:Supplying and fixing 100 A, 2 Way neutral links mounted on DMC/SMC base with connections, in existing meter board |
| 32 | OD17517/2026-2027:Supplying and fixing 100A, HRC Fuse with HRC Fuse link with connections, in existing meter board |
| 33 | OD17521/2026-2027:Supply, conveyance installation of dust and vermin proof, 3 Phase Syntax Meter Board( GS-MB-6535-STD-NF] and to fix KSEB meters, fuse units, CT etc as required including fixing it on wall, making good the damages colour washing etc. as required |
| 34 | OD17533/2026-2027:Supplying and Fixing DIN rail inside the existing MCB DB/ Panel/Meter board etc |
| 35 | OD17528/2026-2027:Supplying and fixing of suitable sizes of light class PVC conduit along with accessories in surface/ recess including cutting the wall/ground/parapet and making good the same in case of recessed conduit as required as service pipe |
| 36 | OD17532/2026-2027:Supplying and Providing M8 anchor bolt hook in wall/parapet for binding support service wire etc as required |
| 37 | 90.14.1.2:Fabrication, supply, conveyance, installation testing and commissioning of floor or wall mounting, dust and vermin proof, cubicle type MV panel board comprising of the following components/ devices & complying to IS 8623.Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments will be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc.Supply and fabrication of MV panel board using 1.6mm CRCA sheet, powder coated (excluding base frame) |
| 38 | 5.4:Earthing with G.I. earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required. |
| 39 | OD17226/2026-2027:Supply, providing and fixing 2 X 25 mm X 3 mm G.I. strip test joint for earthing system |
| 40 | OD17222/2026-2027:Supplying and Providing and fixing 25 mm X 3 mm G.I. strip earth lead from the test joint to the earth plate |
| 41 | 90.16.1.2:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required2.65 mm copper conductor (12 SWG) |
| 42 | 90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 43 | 90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG) |
| 44 | OD17218/2026-2027:Supply and providing 25x6mm brass nut and bolt etc. as required. Please Enable Macros to View BoQ information |