| 1 | Dismantling patent stone floor including stacking serviceable materials in countable stacks within 15M. Lead and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 2 | Dismantling old plaster and pointing in cement or lime and raking out joints to 15mm depth, watering and disposal of unserviceable materials with all leads all complete as per direction of E/I. |
| 3 | Providing 12mm cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 4 | Providing 50mm thick 2nd class patent stone flooring (1:2:4) with 20mm, to 6mm size graded stone chips finished with flooring coat of neat cement in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I. |
| 5 | Providing 6mm cement plaster (1:4) in celling with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 6 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. |
| 7 | Providing 250mm. Wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 250mm apron including cost of eartwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I. |
| 8 | Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily. Size of Tile 600 x 600 mm |
| 9 | Providing and laying 6mm precast white glazed tiles in walls over 12mm cement mortar (1:3) and jointed with grey cement slurry flush pointing with white cement including rubbing, polishing and cost of curring taxes and royalty all complete as per building specification and direction and E/I. With commercial grade colour 15X15cm Tiles. |
| 10 | Providing and fixing 1 mm thik PVC sheet over W.c's door shutter using synthetic rubber based adhesive ( Factor SR 998 or equvalent) |
| 11 | Supplying, fitting and fixing 20 guage G.C.I. Sheet gate fitted on M.S. Angle frame of size 60X60X6mm. Including cost of fabrication, providing necessary locking arrangement with haskal and domny duly fixed in P.C.C. (1:2:4) blocks of required size applying a priming red lead paint over steel work, taxes all complete as per drawing specification and direction of E/I. |
| 12 | supplying, fitting and fixing 250X20X6mm L-type M.S clamp properly fishtailed, including maiking holes and setting as same in 250X125X75mm. Cement concrete block (1:2:4) with cost of all labour and materials and taxes as per building specification and direction of E/I. |
| 13 | Supplying, fitting, and fixing M.S. Grill made of 20X6mm M.S. Flate as per approved design and drawing, properly fabricated with joints continuous fillet welded and finished smooth, carriage of grill to work site, hoisting as per building specification and direction of E/I. (where materials is not supplied by the deptt.) |
| 14 | Providing two coats of plastic emulsion paint of approved shade and make over a coat of cement primer over new surface including preparing plastered surface by rubbing smooth with pumice stone or fine sand paper, applying putty wherever required, scaffolding washing of floor and taxes all complete as per building specification and direction of E/I. |
| 15 | Finishing walls with textured exterior paint of required shade New work (Two or more coats applied @ 3.28 ltr/10 sqm)over and including priming coat of exterior primer applied 2.20kg/10 sqm |
| 16 | Providing two coat of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface throughly , scaffolding and taxes all after removing dirt including scales smokes, grease and sand papering including cost of scaffolding and taxes all complete as per building specification and direction of E/I. |
| 17 | Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: (a)Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound over the RCC slab including adjoining alls upto 300 mm height including cleaning the surface before treatment. (b) After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound (c) Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep. |
| 18 | Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern,ncluding flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 19 | Supplying fitting and fixing 40mm high vitreous white glazed earthen E.W.C. With 'P' trap of parry hindustan or any other approved I.S.S. Make including supplying and fixing 15 litres C.I. Mosquito proof low down flushing cistern of approved make with complete fittings With C.I. handle and R.S. or bracket with telescope flush pipe with brass coupling and plumbers joints spindle stop cock of approved uality weight not less than 450grams 15mm P.V.C. alkathene pipe 45cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/cuckoo or other I.S.S. make with hinges or screws etc. painting pipe and cistern etc. with 2 coats of approved pain over a coat of red oxide priming all complete as per specification anddirection of E/I.(b) With 10 ltr low level PVC cistern |
| 20 | Providing and fixing wash basin with C.I. rackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, ncludingpainting of fittings and brackets, cutting and making good the walls wherever require :White Vitreous China Wash basin size 550x400 mm with a pair of 15 mmC.P. brass pillar taps |
| 21 | Supplying, fitting and fixing the following items complete with all materials as per specification and direction of E/I.(a) glass shelf with C.P. Brass rail.(i) 600X125mm glass shelf complete |
| 22 | Providing and fixing PTMT Bottle Trap for Wash basin and sink. Bottle trap 31 mm single piece moulded with height of 270 mm, effective length of tail pipe 260 mm from the centre of the waste coupling 77 mm breadth with 25 mm minimum water seal, weighing not less than 260 gms. |
| 23 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour weighing not lessthan 105 gms. |
| 24 | Providing & fixing PTMT towel ring trapezoidal shape 215 mm long 200 mm wide with minimum distance of 37 mm from wall face with concealed fittings arrangement of approved quality and colour weighing not less than 88 gms |
| 25 | Providing and fixing C.P. brass bib cock of approved quality confirming to IS:8931 |
| 26 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.75 mm diameter |
| 27 | 110 mm diameter |
| 28 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.110 mm |
| 29 | Single tee with door 110x110x110 mm |
| 30 | Bend 87.5° |
| 31 | Shoe (Plain |
| 32 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.75mm dia |
| 33 | 110 mm dia |
| 34 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of engineer in charge.Internal work -Exposed on Wall 20 mm nominal outer dia pipes |
| 35 | 25 mm nominal outer dia pipes |
| 36 | 32 mm nominal outer dia pipes |
| 37 | 40 mm nominal outer dia pipes |
| 38 | Providing and fixing CPVC pipes having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipe with clamps at 1.00 mt spacing. this includes jionting of pipes and fittings with one step CPVC solvent cement and the cost of cutting chases and making good the wall same including testing of joints complete as per the direction of engineer incharge Concealed work including cutting chases and making good the wall etc. 15 mm nominal outer dia pipes |
| 39 | 20 mm nominal outer dia pipes |
| 40 | 25 mm nominal outer dia pipes |
| 41 | Providing and fixing in position 25 mm diameter mosquito proof coupling of approved municipal design. |
| 42 | Providing and placing on terrace (at all floor levels) polyethylene waterstorage tank, ISI : 12701 marked, with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflowpipes but without fittings and the base support for tank. |
| 43 | Wiring for light/ power plug with 2X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 44 | Wiring for light/ power plug with 4X4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 2 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required. |
| 45 | Wiring for circuit / submain wiring alongwith earth wire with the following sizes of FR PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required 2x1.5 sq mm + 1x1.5 sq mm earth wire |
| 46 | 2x2.5 sq mm + 1x2.5 sq mm earth wire |
| 47 | 4x2.5 sq mm + 2x2.5 sq mm earth wire |
| 48 | 4x10 sq mm + 2x6 sq mm earth wire. |
| 49 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. (5/6 amps one way switch) |
| 50 | 15/16 amp one way switch |
| 51 | 5/6 amp 3 pin socket outlet |
| 52 | 5/16 amp 6 pin socket outlet |
| 53 | Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 54 | Supplying and fixing 2 pin 5 Amp Ceiling rose on the existing junction box/ wooden block including connection etc as required. |
| 55 | Supplying and fixing brass batten/ angle holder including connection etc. as required. |
| 56 | Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FR PVC insulated, copper conductor, single core cable, etc. as required. |
| 57 | Installation of exhaust fan up 450 mm sweep in the existing opening including making the hole to suit the size of above the fan, making good the damage, connection, testing, commissioning etc. as |
| 58 | Supplying and fixing 20 amps, 240 volts, SPN industrial type, socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 59 | Supplying and fixing following ways, horizontal type three pole and neutral, steel, MCB distribution board, 415 volts, on surface/recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without /RCCB/Isolator)8 Way (4+24), Double Door Horizontal Type |
| 60 | Supplying and fixing 6 Amp to 32 Amp rating 240 volts, 10 KA \\"C\\" Curve Miniature Circuit Breaker suitable for inductive loads of following poles in the existing MCB DB complete with connections, testing and commissioning etc.,as required.6 / 32 Amp Single Pole |
| 61 | 40 Amp TPN |
| 62 | Supplying and fixing Single pole blanking plate in the existing MCB DB complete etc. as required. |
| 63 | Supplying and fixing of following rating double pole ( Single pole & neutral), 240 volts, resudual current circuit breaker (RCCB), having a sensivity current 30 miliampere in the existing MCB DB complete with connections, testing & commissioning etc as required.40 Amps |
| 64 | Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required |
| 65 | Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required. |
| 66 | Supply of XLPE insulated PVC sheathed, heavy duty, armoured electrical cable with aluminium conductor for working voltage upto and including 1100 volts. (conforming to IS-7098. (Part-I4 core, 16 sq.mm.). |
| 67 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm |
| 68 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 69 | SITC of following rating recess / surface mounted LED round / square shape down light luminarie with pressure die cast housing for single phase supply voltage Luminarie shall be confirm to IS: 10322 part -5 / section -2 or IEC :62722 withh all neccesary accessories as required. Make:- ips/Crompton/Wipro.9/10 W LED LED Light |
| 70 | 15/16 W LED Tube Light |
| 71 | SITC of 300 mm (12\\") Exhaust fan (Metal body) suitable for single phase 230 volts, 50 Hz., AC supply complete with motor, louvers/shutters etc. complete as required. Make :- Usha/Crompton / Havells . |
| 72 | 1200 mm ( 48\\") BLDC 5 Star rating 32W Ceiling Fan |
| 73 | Earth work in excavation in foundation trenches in ordinary soil ( vide classification of soil item A) and disposal of excavated earth as obtained to a distance upto 50M including all lifts leveling ramming the foundation treanches, removing roots of trees, and shrubs all complete as per approved design, building specification and direction of E/I. |
| 74 | Extra for earthwork in hard soil as per specification and direction of E/I. ( vide classification of soil item-B) |
| 75 | Providing coarse clean sand in filling in in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials labour, royalty and taxes all complete as per building specification and direction of E/I (Mode of measurement compacted volume) |
| 76 | Providing designation 75B brick work in C.M (1:6 ) in foundation and plinth with approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar, joints cost of screening materials raking out joints to 15mm depth , curring , taxes and royalty all complete as per builiding specification and direction of E/I. |
| 77 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size) |
| 78 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mmnominal size) |
| 79 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement, with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 80 | Centering and shuttering including strutting, propping etc. and removal of form for |
| 81 | providing Tor steel reinforcement of 8mm dia rods as per approved design and drawing exclusive carriage of M.S. bars to work site, cutting, bending and binding with annealed wire with cost of the wire, removal of rust, placing the rods in position all complete as per building specification and direction of E/I. TMT Fe 500 (only valid for SAIL & TATA STEEL) 8MM Dia. |
| 82 | 10mm dia |
| 83 | Providing designation 75A one brick flat soling joints filled with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I. |
| 84 | Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I. |
| 85 | Providing 1.5mm cement punning including curing, carriage of water with all leads and lift as per building specification and direction of E/I. |
| 86 | Making soak pit 2.5 m diameter 3.0 meter deep with 45x45 cm dry bricks honey comb shaft with bricks of class designation 75 and S.W drain pipe 100 mm dia 1.8 m |
| 87 | Cement (25+1) KM |
| 88 | Sand (35+5) KM |
| 89 | Stone chips (65+5) KM |
| 90 | Steel (25+1) KM |
| 91 | Bricks(40+5)KM |
| 92 | ADD GST @ 18% |
| 93 | Add 1% L-cess Please Enable Macros to View BoQ information |