| 1 | Supply of Steel Tubular Pole 11 M long designated . complete in all respects UPERC P-40 |
| 2 | Supply of Top MS channel 100x50x2240 mm as per design complete in all respects. UPERC P-39 |
| 3 | Supply of required clamp made of MS Nut and bolt etc. as per design complete in all respects. UPERC P-39 |
| 4 | Erection of metallic pole of of following length in cement concrete 1:3:6 (1 cement: 3 coarse sand: 6 stone aggregate 20 mm nominal size ) foundation including excavation and refilling etc. as required.Above 10.00 meter and upto 12.00 meter(DSR-2018 Item No-11.3.4 |
| 5 | Painting of the electric pole with 2 Coats of Al. paint over red oxide primer complete in all respects. P.S. No. 634 |
| 6 | S/L of 25x3 mm. G.I. Strip from earth electrode directly in the ground as required complete in all respects (P.S. No. 716) |
| 7 | S/F of 11 KV pin 12\\" long with insulator of Jai Shree/BHEL on cross arm fixed on HT pole including all T/P etc. complete in all respects as per direction of E/I (UPERC-2019) Pg-39 |
| 8 | S/E of overhead line with ACSR conductor on steel tubular poles incl.service bracket and binding etc. as UPPWD-2018 PS No. 627 |
| 9 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.PS No-725b (2018) |
| 10 | Supply, Installation, Testing and commissioning of standard4.0 mtr High decorative pole with top post LED Fixture and foundation etc. Complete all accessories as required by E/I (AOR)Make-Neri,K-Lite, Vak,Kesslec. |
| 11 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required. DSR Electrical 2018/ I. No. 11.3.1(A)4.5 metre and upto 6.5 metre |
| 12 | Supply & fixing of 6 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with Single arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect. PS NO. 647 (Make-Bajaj, Valmont,Transrail,GE) |
| 13 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 52 watt to 72 Watt. Confirming to IP66 Protection complete in all respect.CAT-AAA PS. NO-1422 Make-LT, Havells, Bajaj, Philips |
| 14 | S/F of 2.5 sq.mm x 3 core cable as per (AOR Page-19) |
| 15 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top of suitable size of as directed by the Engineer-Incharge, complete in all respects the armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS.No. 501 Grandlay, Havells, Dicab, Polycab, Gloster |
| 16 | a)16 Sq mm x 4core |
| 17 | b)- 50 sq. mm x 3.5 core |
| 18 | Supply and fixing of plain or pin type copper tin plated cable socket (lugs) to the cable leads making connections etc. complete in all respects as pe direction of E/I PS No. 504. |
| 19 | a) 16sq. mm |
| 20 | b)- 50 sq. mm |
| 21 | S/F following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fusese, isolating switch metering instrument & instrument box with CTs etc.in case of TPN complete in all respects. a) 40 A TPN PS No-807 (F) |
| 22 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.PS No-725b (2018) |
| 23 | Supplying and fixing of light class G.I. pipe of 80 mm dia. (nominal) 3 metres length along the pole for protection of under ground cable as required. DSR Electrical - 2018 Item No. 12.38 |
| 24 | Numbering of poles with combination of yellow and black colour paint etc complete in all respects as per direction of E/I (AOR Page-20) |
| 25 | Analysis of Rates for laying of 90 mm dia DWC (Double Wall Corrugated) pipe across the road by Trenchless Method (Manual)(AOR Page-18) |
| 26 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, ouplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level)including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required 90 mm dia (OD-90 mm & ID-76 mm nominal)D.S.R 14.16.2 Pg No-49 |
| 27 | Cement Concrete with 2 cm gauge stone grit, coarse sand & cement in proportion of 4:2:1 including supply of all material, Labour , tools & plants etc. Required for proper completion of work. SOR No. 279(a) |
| 28 | Demolishing R.C.C. Work Manually by mechnical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of E/I.(AOR Page-23) |
| 29 | Laying old Cement concrete interlocking paver blocks of any design/shape laid in required line, level, curvature, colour and pattern over and including 50 mm thick compacted bed of coarse sand, filling the joints with fine sand etc. All complete as per the direction of engineer (AOR Page-24) |
| 30 | Taking out existing CC interlocking from footpath/central verge, including removal of rubbish etc, disposal of unserviceable material to the dumping ground, for wich payment shall be made separately and stacking of serviceable material within 50 metre lead as per direction of E/I.(AOR Page-22) Please Enable Macros to View BoQ information |