| 1 | Erection of PCC Pole 8.5/11 MTR. Long Single Pole with All Accessories complete in All Respect as per RESSPO Norms with cartage from store to site. |
| 2 | Concreting /Grouting of PCC Pole 8.5/11 Mtr. Long (with material) of support up to ground level including back filling and ramming as per RESSPO specification. with cartage from store to site. |
| 3 | Fixing & commissioning of 11 KV VCB O/G CTR 400/200/5A 350MVA with all connection properly including all required material for above work with cartage from store to site. |
| 4 | Fixing & commissioning of 33 KV VCB O/G CTR 1250 AMP with all connection properly including all required material for above work with cartage from store to site. |
| 5 | Laying and stringing of ACSR Rabbit Conductor complete in all Respect with cartage from store to site. |
| 6 | Laying and stringing of ACSR Weasel Conductor complete in all Respect with cartage from store to site. |
| 7 | Fixing of Stay Set Complete & Stay Wire with cartage from store to site |
| 8 | Fixing of 11 KV X Cross Arm Various Type with cartage from store to site. |
| 9 | Fixing of 11 KV Polymeric Pin Insulator with Pin with cartage from store to site. |
| 10 | Fixing of 11 KV Polymeric Disc Insulator with fiiting with cartage from store to site. |
| 11 | Fixing of Stay Wire 7/10 SWG with cartage from store to site. |
| 12 | Fixing of Stay Wire 7/8 SWG with cartage from store to site. |
| 13 | Laying LT XLPE Cable 3x185 SQMM with cartage from store to site. |
| 14 | Fixing of 11 KV Cable Box 3X185 XLPE HT SQMM O/D with cartage from store to site. |
| 15 | Fixing of 11 KV Cable Box 3X185 XLPE HT SQMM I/D with cartage from store to site. |
| 16 | Fixing of 3 Phase Distribustion Box with cartage from store to site. |
| 17 | Laying of LT ABC Cable 3x120+1x95+1x16 SQMM with cartage from store to site. |
| 18 | Laying of LT ABC Cable 3x95+1x70+1x16 SQMM with cartage from store to site. |
| 19 | Laying of LT ABC Cable 3x50+1x35+1x16 SQMM with cartage from store to site. |
| 20 | Laying of LT AL. Cable 1x16 SQMM with cartage from store to site. |
| 21 | Laying of 33 KV 3x300 sqmm XLPE cable from 33 KV VCB panel to Power T/F LT side proper dressing as per resspo norms with cartage from store to site. |
| 22 | Laying of 33 KV 3x300 O/D sqmm XLPE cable from 33 KV VCB panel to Power T/F LT side proper dressing as per resspo norms with cartage from store to site. |
| 23 | Fixing of 33 KVcable Jointing Kit 3x300 sqmm with all accessories as per respo norms with cartage from store to site. |
| 24 | Fixing of 33 KV TPMO with Structure with cartage from store to site. |
| 25 | Laying and stringing of ACSR DOG CONDUCTOR on the pole as per RESSPO specification and as per direction of engineer in charge it includes cost of labour, T & P Carrier etc. required for proper completion of work with cartage from store to site. |
| 26 | Laying and stringing of ACSR Panther CONDUCTOR on the pole as per RESSPO specification and as per direction of engineer in charge it includes cost of labour, T & P Carrier etc. required for proper completion of work with cartage from store to site. |
| 27 | Providing & fixing of 11 KV VCB Numerical Protection Relay . |
| 28 | Fixing Of 33 Kv Bus Insulator with cartage from store to site. |
| 29 | Fixing of 33 KV Line Insulator with cartage from store to site. |
| 30 | Fixing 33 KV LA with cartage from store to site. |
| 31 | Providing & Fixing of WTI/OTI. |
| 32 | Fixing of CT/PT with cartage from store to site. |
| 33 | Fixing of Battary charger with Battary Set with Cartage from store to site. |
| 34 | Fixing of 11 KV VCB for O/G CTR with cartage from store to site. |
| 35 | Fixing of 33 KV VCB 1250 AMP with cartage from store to site. |
| 36 | Fixing of Unarroumed Control Cable 4x2.5 SQMM with cartage from store to site. |
| 37 | Providing & Fixing of Earthing Complete by Pole |
| 38 | Providing & Fixing of F-Bracket |
| 39 | Providing & Fixing of Clamp with Nut & Bolt |
| 40 | Providing & Fixing of Concreting of with Muffing |
| 41 | Providing & Fixing of Danger Board with Clamp & nut and bolt |
| 42 | Providing & Fixing of Stone Pad |
| 43 | Providing & Fixing of Holding Calmp with Nut & Bolt |
| 44 | Providing & Fixing of Concrating of Stay |
| 45 | Providing & Fixing of Top Channel 100x50x6 MM |
| 46 | Providing & Fixing of Ms Angle 65x65x6 MM |
| 47 | Providing & Fixing of LT Clamp with nut & bolt PCC Pole |
| 48 | Providing of HDPE PIPE PN-6, PE-80 140 mm. |
| 49 | Laying of cable by HDD method along with HDPE pipe PN-6, PE-80 140 mm including pilot drilling, reaming, insertion, cable pulling, pit excavation and restoration complete. |
| 50 | Providing & Fixing of Dead and Clamp with J Hook |
| 51 | Providing & Fixing of Suspensin Clamp with I Hook |
| 52 | Providing & Fixing of 3 Phase Distribution Box clamp. |
| 53 | Providing & Fixing of PG Clamp All Size. |
| 54 | Providing & Fixing of LT Perice Connetor All Size. |
| 55 | Providing & Fixing of Lt Shacle Insulator. |
| 56 | Providing & Fixing of GI Pipe 6\\" DIA |
| 57 | DISMENTLING & CARTAGE OF OLD AND USED 11 & 33 KV VCB ALL REST METERIAL & OTHER ACCESSORIES LOADING & UNLOADING AT BOTH END RECEIVED BACK FROM SITE TO CENTRAL STORE GHAZIABAD. |
| 58 | DISMENTLING & CARTAGE OF OLD AND USED 33 KV L.A (18 NO), 33 KV CT 40/200/1A (07 NO), BATTERY CHARGER 24 VOLTS (06 NO), BATTERY SET 12 NOS (06 NO) ALL REST METERIAL & OTHER ACCESSORIES LOADING & UNLOADING AT BOTH END RECEIVED BACK FROM SITE TO CENTRAL STORE. |
| 59 | DISMENTLING & CARTAGE OF OLD AND USED ACSR WEASEL/DOG CONDUCTOR/WIRE/XLPE CABLE/AB CABLE ALL REST METERIAL & OTHER ACCESSORIES LOADING & UNLOADING AT BOTH END RECEIVED BACK FROM SITE TO CENTRAL STORE. |
| 60 | DISMENTLING & CARTAGE OF OLD AND USED ST POLE ALL REST METERIAL & OTHER ACCESSORIES WITH LOADING & UNLOADING AT BOTH END RECEIVED BACK FROM SITE TO CENTRAL STORE. Please Enable Macros to View BoQ information |