| 1 | Baneswar Sub station |
| 2 | Grand Total Supply & Service |
| 3 | Switchyard & Control Room |
| 4 | PCC POLE 9M |
| 5 | MS CHANNEL 100 X 50 MM |
| 6 | MS CHANNEL 75X40 MM |
| 7 | MS ANGLE 65 X 65 X 6 MM |
| 8 | MS ANGLE 50 X 50 X 6 MM |
| 9 | COND ACSR RBT 50SMM |
| 10 | H/W FITTING FOR RABBIT |
| 11 | FABRICATION OF IRON MATERIAL(ANGLE ,CHANNEL& FLAT) as per WBSEDCL Specification & Fabricated steel structure items shall be hot dip galvanized and cleaned till good surface finish. The minimum coating of the zinc shall comply with IS: 2629 and IS: 2633 (with latest amendments). Galvanizing shall be checked and tested in accordance with IS: 2633. Items shall be offered for inspection and approval by Controlling Officer |
| 12 | ISL 33KV 400A CRTYPE WO ES(H/L) |
| 13 | ISL 33KV 400A CR TYPE WO ES(L/L ) |
| 14 | H/W SINGLE TENSION FOR PANTHER COND |
| 15 | 33KVPOLYMER COMP. WH FTTG DISC INSL70KN |
| 16 | 33KVPOLYMER COMP. WH FTTG PIN INSL 10KN |
| 17 | LA42KVCLASS(10KA)FOR33KV |
| 18 | LA12KV(10 KA)FOR11KV |
| 19 | COND ACSRPANTHER200SQMM |
| 20 | CT 33KV 200-100/1 3C1-PhOD |
| 21 | CT 33 KV 400-200/1 A 2C 1-PH OD |
| 22 | CuCONT.CAB1.1KV12C2.5SMM |
| 23 | CuCONT.CAB1.1KV8C2.5SMM |
| 24 | CuCONT.CAB1.1KV4C2.5SMM |
| 25 | 11KVXLPE3C185SMM CABLE |
| 26 | 11KVXLPE3C300SMM CABLE |
| 27 | 33KV SCADA TR CRP INCND RELAY & METERS |
| 28 | 33 KV SCADA FDR CRP INC ND RELAY & Meters |
| 29 | U&H POWER TRANSFORMER 6.3MVA |
| 30 | RTCCPNLFOR6.3MVA 33/11KVTRNFWHOLTC |
| 31 | Switchgear(shunt trip)with VCB 4 PNL(1+1+2) |
| 32 | TPGO Isolator 11, KV 400 Amp. |
| 33 | JOINTING OF OUT DOOR TYPE HEAT SHRINKABLE TERMINAL JOINTING KIT FOR 11KV 3X300 SQ.MM XLPE Cable. |
| 34 | JOINTING OF INDOOR TYPE HEAT SHRINKABLETERMINAL JOINTING KIT FOR 11KV 3X300 SQ.MM XLPE Cable(Make:RAYCHEM) |
| 35 | JOINTING OF OUT DOOR TYPE HEAT SHRINKABLETERMINAL JOINTING KIT FOR 11KV 3X185 SQ.MM XLPE Cable (Make:RAYCHEM) |
| 36 | JOINTING OF INDOOR TYPE HEAT SHRINKABLE TERMINAL JOINTING KIT FOR 11KV 3X185 SQ.MM XLPE Cable(Make:RAYCHEM) |
| 37 | MS.FLAT 75 X8 |
| 38 | MS.FLAT 65 X 6 |
| 39 | MS CHANNEL 100 X 50 MM |
| 40 | Supply of GI Pipe(40 mm ineer dia,5 mm thick,3M long with perforation of 12 mm dia holes @150mm from each other at right angle with removable type top cap & clamp |
| 41 | 11 KV XLPE Cable 185 sq mm 3 core |
| 42 | L.A. 12 kv. 10 kA For 11 kv Line |
| 43 | out door Termination Kit for 11 KV XLPE Cable 185 sq mm 3 core |
| 44 | PCC POLE 9M |
| 45 | PCC POLE 8 M LONG |
| 46 | CHANNEL 75X40X6 MM |
| 47 | ANGLE 65X65X6 mm |
| 48 | M.S. Flat 65x6 mm |
| 49 | GI STAY SET HT (1830X20MM)WRKG LD-7900KG |
| 50 | G.I STAY WIRE 7/3.15 MM (10 SWG) |
| 51 | PORCELAIN GUY INSULATOR HT |
| 52 | 11 KV \\"V\\" BRACKET FOR PCC POLE 8M LONG |
| 53 | 11 KV TOP ADAPTOR FOR PCC POLE 8M LONG |
| 54 | 11KVPOLYMER COMP. WH FTTG PIN INSL 5KN |
| 55 | 11KVPOLYMER COMP. WH FTTG DISC INSL 45KN |
| 56 | COMPOSITE H/W FITTGS. FOR 30/50SMM COND |
| 57 | TPGO ISOLATOR 11KV 400 AMP |
| 58 | ACSR 50SQMM, RABBIT |
| 59 | EARTH SPIKE |
| 60 | GI WIRE 6 SWG / 5 MM |
| 61 | GI WIRE 8 SWG / 4 MM |
| 62 | SWITCHYARD STRUCTURE |
| 63 | Installation of 6.3 MVA PTR |
| 64 | Erection of 4-pole HL Isolator structure without Earth Switch & LA(Ref Drawing No:-RE/SS/39) by 9M PCC pole using CC slab of 600x600x100 mm of ratio 1:3:6 in the base with full concreting of pole foundation of 600X600x1500 mm( upto GL) with fixing of iron structure but without any insulator.All Poles will be supplied by WBSEDCL. |
| 65 | Erection of 4-pole Sub-station structure for 33 KV L.L. Isolator support without Earth Switch (Ref. Drg. No. RE/SS/41) by 9M PCC pole using CC slab of 600x600x100 mm of ratio 1:3:6 in the base ,full concreting of pole foundation of 600X600x2500 mm(upto GL) with fixing of iron structure but without any insulator.All Poles will be supplied by WBSEDCL. |
| 66 | Erection of 33KV, 400A, centre rorating isolators H.L. W/O E.S. |
| 67 | Fixing of 70KN 33KV Disc Insulator with strain hardware(to be suplied by WBSEDCL) on sub station structure. |
| 68 | Fixing of 33KV Pin Insulator(to be suplied by WBSEDCL) on sub station structure. |
| 69 | Erection of 42 KV grade LA structure with supply of nut & bolts including foundation |
| 70 | Fabrication and Fixing of 12 KV grade LA on existing structure |
| 71 | Strining & sagging of wire bus(3 wire system) with necessary connection with Isolator & other equipments including jumpering,droper as per instruction of site officer with 200sq mm ACSR PANTHER including fixing of GI Eye bolt 9\\"x5/8\\" and necessary quantities of compression type long barrel extruded aluminium connectors(800 amp)(24 nos Panther to Panther T connector,12 nos CT stud to Panther,12 no VCB stud to Panther,03 nos PT stud to Panther connector ,45 nos.Isolator Pad to Panther,3 nos LA stud to Panther, 3nos Panther to 33KV PTR stud Bi-metallic connectopr, 03 nos Station service DTR HV bushing to Panther,03 nos LV bushing PTR to Panther, 03 nos Station service DTR LV bushing to 185 sq.mm cable connector ,06 nos Panther to 11KV 300 sq. mm Cable end connectors,06 nos. PANTHER to RABBIT T connector etc)creamping tools should be arranged by the agency |
| 72 | Stringing & sagging of shielding wire (1wire system) by ACSR 50 sq mm |
| 73 | HT Stay set Complete with all fittings,guy insulator, binding etc. |
| 74 | Erection of 33 KV VCB and its allied structures as supplied by manufacturer with fixing of foundation bolt over the concrete foundation maintaining proper vertical alighnment. |
| 75 | Fixing of CT structures (Ref. Drg PLN(D)/SS/57) and erection of 3 Nos. 1-Ph 33KV C.T on the structure including supply of suitable size of 18 way UV ray proof PVC Junction Box. |
| 76 | Erection of 11 KV cable box supporting frame work(Ref. Drg. No.PLN(D)/SS/79 & PLN(D)/SS/85) including necessary concrete foundation. |
| 77 | Erection of Neutral Earthing Support Stand and Neutral Earthing with 65x6 mm flat after grouting of necessary length of 100x50 mm Channel including necessary concrete foundation i.r.o 6.3/10 MVA 33/11KV PTR |
| 78 | Fixing of 11 KV TPGO Isolators 400 Amps on 9M DP with smooth operation and adjustment |
| 79 | Installation of GI Pipe(40 mm inner dia,5 mm thick, 3M long with perforation of 12 mm dia holes @150mm from each other at right angle with removable type top cap & clamp.The clamp shall be 250mm long by 65X6mm flat) in the earth vertically for Pipe Earthing by excavating/boring soil 3.3M depth and 320x320mm wide.Excavated earth should be back filled with two layers of charcoal and salt each alternatively with thickness of each layer will be 150mm for proper earthing .GI pipes have to be supplied by the agency. |
| 80 | Construction of inspection pit of 300x300x450mm size(inside measurement) 250 mm thick brick work of ratio1:3:6, 12mm thick cement plaster(1:4) in the interwall surface and upto 150mm below the ground level of the outer surface including neat cement punning.The pit shall be covered with precast RCC slab 50mm thick(1:2:4) reinforced with 10mm dia M.S. rod @100mm centre to centre both ways including lifting lugs of 10mm dia M.S. rod at the middle of the slab with the proper finish of the slab on all sides. |
| 81 | Supply & erection of CT junction box |
| 82 | Supply of aluminium connectors(800 amp)(24 nos Panther to Panther T connector,12 nos CT stud to Panther,12 no VCB stud to Panther,03 nos PT stud to Panther connector ,45 nos.Isolator Pad to Panther,3 nos LA stud to Panther, 3nos Panther to 33KV PTR stud Bi-metallic connectopr, 03 nos Station service DTR HV bushing to Panther,03 nos LV bushing PTR to Panther, 03 nos Station service DTR LV bushing to 185 sq.mm cable connector ,06 nos Panther to 11KV 300 sq. mm Cable end connectors,06 nos. PANTHER to RABBIT T connector etc) |
| 83 | Supply of GI Pipe(40 mm ineer dia,5 mm thick,3M long with perforation of 12 mm dia holes @150mm from each other at right angle with removable type top cap & clamp |
| 84 | Installation of 33 KV Feeder Individual Control and Relay panel at the specified place of Control Room including grouting ,leveling,tightening of Nut,Bolts and Spring Washers after laying 100x50 mm Channel at the bottom of each Panel flushed with Control Room floor, dismantling & refixing of Relays and meter etc and all other related work as instructed by site engineer upto commissioning. |
| 85 | Installation of 33 KV transformer Individual Control and Relay panel at the specified place of Control Room including grouting ,leveling,tightening of Nut,Bolts and Spring Washers after laying 100x50 mm Channel at the bottom of each Panel flushed with Control Room floor, dismantling & refixing of Relays and meter etc and all other related work as instructed by site engineer upto commissioning. |
| 86 | Installation of RTCC panel at the specified place of Control Room including grouting ,leveling,tightening of Nut,Bolts and Spring Washers after laying MS Channel 100x50 mm at the bottom of each Panel flushed with Control Room floor, dismantling & refixing of Relays and meter etc and all other related work as instructed by site engineer upto commissioning. |
| 87 | Installation of 11 KV shunt trip VCB Panel that include Incoming VCB,Outgoing VCB and Buscoupler (1IN+1BC+2OG) at the specified place of Control Room with proper grouting and tightening of Nut,Bolts and Spring Washers after laying Channel 100x50 mm at the bottom of each Panel flushed with Control Room floor for smooth running of VCB truck,fixing of each Panel with other having a proper vertical alignment,fixing of Bus Bar with each other tightly through out the Panel length,interconnection of Panel wiring including supply of single core 2.5 sq mm. flame proof PVC Copper wire(Havels make),Copper ferrules ,Copper socket,Copper Tie link,PVC Tape and all other related work as instructed by site engineer upto commissioning. |
| 88 | Laying of 11 KV Gr. 3C X 300 sqmm XLPE cable through trench(with loop) incuding raising upto the top of each 11 KV Cable End Supporting Frame and 11 KV CT Connecting Point of Incoming Control Panel and connecting to equipments with supply of GI nut,bolts and washers , necessary Flat to be supplied by WBSEDCL . |
| 89 | Laying of 11 KV Gr. 3CX 185 sqmm XLPE cable through trench(with loop) including raising upto 5M length of each terminal DP and 11 KV CT Connecting Point of outgoing Control Panel and connecting to equipments with supply of GI nut,bolts and washers, necessary Flat to be supplied by WBSEDCL . |
| 90 | JOINTING OF OUT DOOR TYPE HEAT SHRINKABLE TERMINAL JOINTING KIT FOR 11KV 3X300 SQ.MM XLPE Cable. |
| 91 | JOINTING OF INDOOR TYPE HEAT SHRINKABLETERMINAL JOINTING KIT FOR 11KV 3X300 SQ.MM XLPE Cable |
| 92 | JOINTING OF OUT DOOR TYPE HEAT SHRINKABLETERMINAL JOINTING KIT FOR 11KV 3X185 SQ.MM XLPE Cable |
| 93 | JOINTING OF INDOOR TYPE HEAT SHRINKABLE TERMINAL JOINTING KIT FOR 11KV 3X185 SQ.MM XLPE Cable |
| 94 | Laying of 1.1 KV grade 4 Core 2.5 sq mm PVC armoured Copper control Cable through pucca cable trench and connections at different points of Equipment at switchuard and control room with fixing of Copper Lugs/sockets,Ferrules,Copper gland of required size (to be supplied by the agency) and proper dressing and numbering of the laying control cables as per instruction of site in-charge |
| 95 | Laying of 1.1 KV grade 8Core 2.5 sq mm PVC armoured Copper control Cable (To be supplied by WBSEDCL) through pucca cable trench and connections at different points of Equipment at switchuard and control room with fixing of Copper Lugs/sockets,Ferrules,Copper gland of required size (to be supplied by the agency) and proper dressing and numbering of the laying control cables as per instruction of site in-charge |
| 96 | Laying of 1.1 KV grade 12Core 2.5 sq mm PVC armoured Copper control Cable (To be supplied by WBSEDCL) through pucca cable trench and connections at different points of Equipment at switchuard and control room with fixing of Copper Lugs/sockets,Ferrules,Copper gland of required size (to be supplied by the agency) and proper dressing and numbering of the laying control cables as per instruction of site in-charge |
| 97 | Laying and jointing of Earth strip with MS 75x8 mm Flat including bending to shape as required,after excavation of soil upto 0.6M below the G.L and back filling. (Running welding of earth strip should be minimum 100 mm lapping) as per earth mat design ( as per design of WBSEDCL). Each joint should be running welded using good quality of electrode and painted with Black Bitumen paint of reputed brand after scrapping & smoothing of surface. |
| 98 | Laying and jointing of 65 x 6 mm. Flat from Earth Grid upto finished groud level of all sub-station equipments structure including Shielding Poles,Cable supporting frame,GI Pipes and neutral stand which includes excavation of soil & back filling the same as per instruction of site in-charge .Each joint should be running welded using good quality of electrode and painted with Black Bitumen paint of reputed brand after scrapping & smoothing of surface |
| 99 | Erection of Riser by 65X6mm Flat above the ground level to connect all Sub-station equipment body and as well as all other iron structures at multiple points as per instruction of site in-charge.Each joint should be running welded using good quality of electrode and painted with Black Bitumen paint of reputed brand after scrapping & smoothing of surface. |
| 100 | Laying and jointing of double earth grid with 65X6mm Flat from earth grid upto control room running earth point throgh the cable trench and connecting the same both side as per instruction of site in charge.Each joint should be running welded using good quality of electrode and painted with Black Bitumen paint of reputed brand after scrapping & smoothing of surface. |
| 101 | Installation of GI Pipe(40 mm inner dia,5 mm thick, 3M long with perforation of 12 mm dia holes @150mm from each other at right angle with removable type top cap & clamp.The clamp shall be 250mm long by 65X6mm flat) in the earth vertically for Pipe Earthing by excavating/boring soil 3.3M depth and 320x320mm wide.Excavated earth should be back filled with two layers of charcoal and salt each alternatively with thickness of each layer will be 150mm for proper earthing .GI pipes have to be supplied by the agency. |
| 102 | Construction of inspection pit of 300x300x450mm size(inside measurement) 250 mm thick brick work of ratio1:3:6, 12mm thick cement plaster(1:4) in the interwall surface and upto 150mm below the ground level of the outer surface including neat cement punning.The pit shall be covered with precast RCC slab 50mm thick(1:2:4) reinforced with 10mm dia M.S. rod @100mm centre to centre both ways including lifting lugs of 10mm dia M.S. rod at the middle of the slab with the proper finish of the slab on all sides.All materials have to be supplied by the agency.(INCLUDING 4 NOS FOR ptr) |
| 103 | Erection of Neutral Earthing Support Stand and Neutral Earthing with 65x6 mm flat after grouting of necessary length of 100x50 mm Channel including necessary concrete foundation i.r.o 6.3/10 MVA 33/11KV PTR |
| 104 | Survey(Pr&Finl) for HT line upto 33KV |
| 105 | Excavation of Cable tranch depth of 1.5 mm and 0.75 mm wide by cutting metal road/cement concrete/brick soiling etc |
| 106 | Supply and laying of 1 st. class bricks. |
| 107 | Making of cable end termination kit for 11 kv XLPE 185 Sq.mm 3 core. |
| 108 | Laying of cable 11 kv XLPE 185 Sq.mm 3 core. |
| 109 | Micro turneling work with laying of 110 mm dia HDPE Pipe |
| 110 | Supply & erection of cable marker |
| 111 | Earthing by driven of 50 mm dia 3 mtr long midium gage G.I. Pipe connected with each other by 50x6 mm. Flat and earth riger connected up to L.A. & Cable earthing point. |
| 112 | Fixing of station Class 12 Kv. L.A. for 11 kv. Line. (3 nos. L.A. in a Set.) |
| 113 | Erection of 4Pole structure 9 mtrs long PCC pole |
| 114 | Erection of DP structure 9 mtrs long PCC Pole |
| 115 | Erection of Single Pole with out fittings 8M PCC |
| 116 | Erection of Tripple Pole with all fittings 8M (Paint) |
| 117 | Dismnt. & Double Pole @40% of Rs.5654.00 |
| 118 | Extension of S.P. complete W/Fitt PCC |
| 119 | Fixing of cable support channel (Rate treath as Tee of fitting DP) |
| 120 | Fixing of Pin Angle on DP (Rate treated as CG Bracket on DP) |
| 121 | Fixing of Double circuit Bracket on 4 pole & DP (Rate treated as fixing of Tee off Bracket on DP) |
| 122 | Stringing & Laying of conductor ACSR-50 - 3Wire |
| 123 | Earthing Complete & Driving of earth Spike & conn. |
| 124 | Fixing of HT Stay sets (1830x20mm) |
| 125 | Fixing of Solid T-Off Bracket with out Isolator - S.P. |
| 126 | Fixing of TPGO Isolator online Structure ( D.P. / any Compd.) |
| 127 | Fabrication & Fixing of C.G. Bracket - Single Pole |
| 128 | Fabrication & Fixing of C.G. Bracket - D. P. |
| 129 | Making & Fixing of cross lacing |
| 130 | Fixing of Lead Wire above 30 mtrs upto 60 mtrs - 2-wire |
| 131 | Fixing of Lead Wire above 60 mtrs upto 100 mtrs - 2-wire |
| 132 | Fixing of V-Bracket-8M/Cross Arm |
| 133 | Fixing of Top Adopter-8M |
| 134 | Fixing of 11 KV Polymer Pin Insulator |
| 135 | Fixing of 11 KV Polymer Disc Insulator |
| 136 | Resagging of cond. ACSR-50 sqmm - 3 wire |
| 137 | Dismt. & Refixing of 11 KV PIN Insulator |
| 138 | Dismt. & Refixing of 11KV DISC Insulator |
| 139 | GIS field survey & mapping |
| 140 | 2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 141 | 2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm) |
| 142 | 2 x 56/0.3 (4 sqmm) + 1 x 36/0.3 (2.5 sqmm) |
| 143 | Supplying and fixing PVC casing-capping [Precision Make] on wall or ceiling, incl. necy. PVC fittings etc. and mending good damages to building works |
| 144 | 20x10mm Size |
| 145 | 25x10mm Size |
| 146 | Supplying & Fixing GI Modular Switch Board of the following sizes complete with three no. suitable size Copper bar with holes (for Ph, N & E) fixed on bakelite/Hard Rubber insulator over the MS welded chairs incl. top cover flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building worksa) 8 Module |
| 147 | b) 4 Module |
| 148 | c) 12 Module |
| 149 | Average run 6 mtr |
| 150 | Average run 9 mtr |
| 151 | Average run 12 mtr |
| 152 | On Board |
| 153 | Average run 6 mtr |
| 154 | Supplying and fixing polythene pipe complete with fittings asnecy. under ceiling/beam, bound with 22 SWG GI binding wireincl. supplying and drawing 1x18 SWG GI Wire as fish wireinside the pipes and fittings and providing 50 mm dia disc ofMS sheet (20 SWG) having colour paint at one face fastenedat the load point end of the polythene pipe with fish wire(synchronizing with roof/beam casting work of buildingconstruction) 13mm dia 3mm thick Polythene Pipe |
| 155 | Supply & Fixing 240 V 16 A Piano key type switch (Brand approved by EIC) on GI Modular type switch board having top cover plate and making necessary connections as required |
| 156 | Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. |
| 157 | Supplying Exhaust fan Anchor (300mm). |
| 158 | Fixing only exhaust fan after making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter: 30 Cm or (12\\") |
| 159 | Supplying Wall Fan as per Brand Anchor/Polycab 400mm |
| 160 | Supplying ceiling Fan as per Brand (Surya / Havloc/ Polycab)1200 mm |
| 161 | Supply & Fixing Socket type fan regulator (Step type)(Brand approved by EIC) on existing sheet metal switchboard with bakelite/perspex top cover by screw aftermaking housing for regulator knob by cuttingbakelite/perspex top cover incl. making necy. connectionsetc |
| 162 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts & washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20 PVC insulated flexible copper wire 0.5 mt. length |
| 163 | Supply, delivery of single LED tube light(18/20)W (Make- phillips/ Havells/ Bajaj) |
| 164 | Supply, delivery of twin LED tube light(18/20)W (Make- phillips/ Havells/ Bajaj) |
| 165 | Fixing only single/twin fluorescent light fitting complete with allaccessories directly on wall/ceiling with HW block and ceilingplates, nipples etc. as required |
| 166 | Supplying and fixing 240/415 V DP MCB Isolator on din rail of existing DBs and necessary connection.40A Legrand |
| 167 | Supplying and fixing 240/415 V SPMCB of Breakingcapacity 10kA & C characteristics on din rail ofexisting DBs and necessary connection 6-32 A |
| 168 | Supplying and fixing double-door SPN MCB DistributionBoard with IP-42/43 protection, concealed in wall aftercutting the wall & mending good the damages tooriginal finish incl. Inter connection with suitable size ofcopper wire and neutral link & provision for earthingattachment. 2+6 way Schneider |
| 169 | Supplying and fixing 415 V Four Pole MCCB of 250A (Make- Standard/ Havells/HPL/ Anchor/Schneider)Breaking capacity 25kA/35kA with fixed thermaland fixed magnetic / adjustable thermal and fixedmagnetic setting in existing DBs / enclosure andnecessary connection |
| 170 | Supplying and fixing MCCB SS enclosure with IP- 20/30 protection, pwder coated provision for housing Four pole (4P) MCCB, concealed in wall after cutting the wall & mending good the damages to original finish / on flat iron frame incl. painting, connection & provision for earthing attachment (standard) |
| 171 | Supplying and fixing MCB SS enclosure with IP-20/30 protection, powder coated provision for two/four pole MCB, concealed in wall after cutting the wall & mending good the damages to original finish incl. painting, connection & provision for earthing attachment 4way |
| 172 | Supply of pedestral fan (Stand Fan) (make -Havells/ C.G/standard) |
| 173 | Supply and Fixing of Single Arm Bracket(GI) on existing Rail pole |
| 174 | Supply and Fixing of Single Arm Bracket(GI) on conntrol room wall including mending of damages if any |
| 175 | Supply and fixing of GI terminal Box ( 4 way) on the base of Rail pole/PCC pole/wall providing cut-out/MCB. |
| 176 | Supply and Laying of 1.1 KV 4 core 16 sq.mm PVC aluminium aurmour cable by cutting concrete and mending the damages if any for incoming terminal box connection as it is(as directed by site Engineer) |
| 177 | Supply and laying,fixing of 1.1 KV 4 Core 16 sq.mm PVC aluminium aurmour cable on cable trench wall/control room wall by GI/PVC 'U'clamp through PVC 32 mm dia Pipe including mending the damage if any for ACDB to Main DB & incoming terminal box connection . |
| 178 | Termination of above cable including supply and fixing of gland, aluminium lugs, etc.( standard quality, as approved by site Engineer) |
| 179 | Supply and fixing of GI pipe (3/4 '' dia.) with elbow Cap etc.for drawal of PVC cable for Rail pole/ PCC pole/ wall |
| 180 | Supply and drawal of PVC 2 core ,4 sq. mm coper wire through GI pipe (3/4 '' dia.) with necessary termination on Rail pole/ PCC pole/ wall for LED flood lighting/gate lighting |
| 181 | Supply and fixing of PVC pipe rigid/ flexible (required size) in pole mounting for entry and exit of Al cable from terminal box. |
| 182 | Supply and laying of GI pipe 32 mm Dia across the main gate by cutting concrete road (if necessary) with mending the good damages. |
| 183 | Supply and fixing of gate light with SPC 101/70 (E) type philips/havells make with 1 X 80 watt / 70 S gate by supplying 2 \\" dia. G.I pipe with mending all good damages. |
| 184 | Supply and fixing of wires net cover on the fixture of gate light |
| 185 | Supply and delivery of 6'x4' Glow sign board of Ply Vinyl front and backside of GI sheet including necessary LED lighting arrangement (4X18W) and 50x50x6mm mm GI angle for installation of Box protection .Glow sign board includes details of Company Name, sub station name,adress,Scheme Name and as desired by site Engineer. |
| 186 | Installation of GI Pipe(40 mm inner dia,5 mm thick, 3M long with perforation of 12 mm dia holes @150mm from each other at right angle with removable type top cap & clamp.The clamp shall be 250mm long by 65X6mm flat) in the earth vertically for Pipe Earthing by excavating/boring soil 3.3M depth and 320x320mm wide.Excavated earth should be back filled with two layers of charcoal and salt each alternatively with thickness of each layer will be 150mm for proper earthing .GI pipes have to be supplied by the agency. |
| 187 | Construction of inspection pit of 300x300x450mm size(inside measurement) 250 mm thick brick work of ratio1:3:6, 12mm thick cement plaster(1:4) in the interwall surface and upto 150mm below the ground level of the outer surface including neat cement punning.The pit shall be covered with precast RCC slab 50mm thick(1:2:4) reinforced with 10mm dia M.S. rod @100mm centre to centre both ways including lifting lugs of 10mm dia M.S. rod at the middle of the slab with the proper finish of the slab on all sides. |
| 188 | Painting of all PCC,Shielding Poles with one coat primer and two coats synthetic enamel paint and as per direction of site-in-charge.(Materials supplied by the Contractor) |
| 189 | Railway Crossing Permission |
| 190 | Supply and Installation of 08 Nos LED Flood light (preferably Havells/Philips make ) with complete set of 200W each and supply of 08 Nos LT Junction Box for yard light. Please Enable Macros to View BoQ information |