| 1 | Supply & fixing of 7 mtr GI Octagonal Pole of approved make (top dia 70mm, Bottom dia 130mm and base plate 12mm thik) having 3mm thikness with single arm bracket (1 Mtr length) on RCC foundation including the cost of foundation, foundation bolts, excavation & back filling and Required T&P completee in all respect. PS NO. 641Make- Bajaj, Valmont, Transrail |
| 2 | Supply and fixing of LED Street light Fitting having die cast aluminium body and diffuser with driver set suitable for 75 to 90 Watt. Confirming to IP 66 and above Protection complete in all respect.CAT-AAA PS. NO-1423 Make-Havells,LT, Bajaj, Philips |
| 3 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top of suitable size of as directed by the Engineer-Incharge, complete in all respects the armouring of the cable shall be properly connected with the earth conductor by clamps etc. PS.No. 501 Grandlay, Havells,Dicab, Polycab, Gloster |
| 4 | a)- 16 sq. mm 4 core |
| 5 | b)- 50 sq. mm 3.5 core |
| 6 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge. PS No. 504 |
| 7 | a) 16 sq mm |
| 8 | b)- 50 sq. mm |
| 9 | Supply and fixing of XLPE insulated Aluminium unarmoured cable for working voltage for enerizing the distribution boxes and street light of size 1x 16 Sq. mm all respect as per E/I. |
| 10 | Supplying and laying of following size DWC HDPE pipe lSI marked along with all accessories like socket, bend, ouplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level)including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required 90 mm dia (OD-90 mm & ID-76 mm nominal)D.S.R 14.16.2 Pg No-49 |
| 11 | Analysis of Rates for laying of 90 mm dia DWC (Double Wall Corrugated) pipe across the road by Trenchless Method (Manual) |
| 12 | S/F following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fusese, isolating switch metering instrument & instrument box with CTs etc.in case of TPN complete in all respects. a) 40 A TPN PS No-807 (F) |
| 13 | Supply and burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000mm, outer Dia 50 mm inner Dia 25 mm, terminal Dia 12mm, outer GI pipe of 16 swg and inner GI pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25mm x 3mm G.I. strip, upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing. Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. UPPWD-2018, PS 725B |
| 14 | S/L of 25x3 mm. G.I. Strip from earth electrode directly in the ground as required complete in all respects (P.S. No. 716) |
| 15 | Dismantling of pole/street light standard/strup ambedded in cement concrete foundation etc.as required DSR-2018 Item No.12.42 |
| 16 | Cement Concrete with 2 cm gauge stone grit, coarse sand & cement in proportion of 4:2:1 including supply of all material, Labour , tools & plants etc. Required for proper completion of work. SOR No. 279(a) |
| 17 | Demolishing R.C.C. Work Manually by mechnical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of E/I. (AOR) |
| 18 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required. bituminous portion (AOR) |
| 19 | Numbering of poles with combination of yelow and black colour paint etc. complete in all respects as per direction of E/I (AOR) |
| 20 | S/F of Copper Cable 2.5 sq.mm x 3 core Complete in all respects as per AOR |
| 21 | S/E testing & Commissioning of 63 KVA AI wound outdoor type Transformer as per ISS including fees Complete in all respects Make P.M./Kanohar/LD Power/Peramix as per direction of E/L UPERC P-51 Cost Data book 2019 |
| 22 | Supply of Steel tubular pole 11 mtrs long designated at 410-sp 56 including excavation back filling etc complete in all respects UPERC P-30 |
| 23 | Errection of metallic pole of following length in cement concrete 1:3:6 ( 1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required above 10.0 mtr and upto 12 mtr (DSR 2018 I. n. 11.3.4) |
| 24 | S/F of Top Channel MS 125x65x3200 mm. Complete in all respects. as per direction of E/I. .((UPERC P-30) |
| 25 | Supplying and erection of 11kV pin insulator complete with large steel head G.I. Pin, nuts & washer etc. as required (DSR-2018 item no. 13.10 pg.46) |
| 26 | S/E of \\"D\\" Clamp of 50x6 mm. M.S. flat iron on steel tubular poles/steel rail poles with bolts and nuts etc. complete in all respects. As per direction of E/I. P.S. No. 623. |
| 27 | Supplying and erection of 11kV Disc insulator for 11kV overhead line with galvanised inculator fitting, ball and socket type and complete with galvanised strain clamp, bolts, nuts & washer etc. as required (DSR-2018 item no. 13.11 pg.45) |
| 28 | S/F of 11 KV TPMO Relco/Rama/Azad make 9 Nos. insulator of Jai shree/BHEL/ Rama/ Rastriya make complete in all respects as per direction of E/I.(UPERC page no. 58) |
| 29 | S/F of out door type 11KV fuse set Relco/Rama/Rastriya make with insulator Jai shree/BHEL make complete in all respects as per direction of E/I..(AOR) |
| 30 | M.S. Strip (50x6mm ) Fencing (6 Feet Height including Civil work) as per direction of E/I. (UPER-2019) pg-53 Please Enable Macros to View BoQ information |