| 1 | Removing & cleaning of blockage WC including WC trap of any description and in any position by removing sand/sludge/silt and other forein material deposited in it (either manually or mechanically) upto first manhole and making the sewage system functional to the entire satisfaction of Engr in Charge complete. |
| 2 | Removing & cleaning of blockage from traps of bath rooms/ kitchen sink/ wash basin/ Urinal point and gully traps of any description and in any position by removing sand/sludge/silt and other forein material deposited in it (either manually or mechanically) upto first manhole and making the seweage system functional to the entire satisfaction of Engr in Charge complete. |
| 3 | Taking out carefully the cover slab of gulley traps of any size and shape, depth and cleaning the block by removing the scum/sludge / any material to a distance exc. 250m and n.exc.500m and cleaning with fresh water placing the cover slab/ Grating in position all as directed by Eng-in-Charge. |
| 4 | Cleaning of sewage lines using passing rubber ball through line to ensure all blockage perfectly clear or split bamboo with a gunny bag piece tied with bamboo with binding wire and inserting the bamboo in sewage lines of dia 100 mm and up to 200 mm through manhole/gully trap clear flow of sewage is observed in sewage pipe complete all as directed by Engr-in-charge. |
| 5 | Cleaning manhole with spades or bucket taking out sludge manhole and disposed off aside by burying the entire sludge under ground in a pit of suitable size by putting earth on it. Again use water with bucket and put into manhole to clear the sludge and ensure the sludge is drain out completely. The depth of manhole n. exc. 1 metre each. |
| 6 | Cleaning manhole with spades or bucket taking out sludge manhole and disposed off aside by burying the entire sludge under ground in a pit of suitable size by putting earth on it. Again use water with bucket and put into manhole to clear the sludge and ensure the sludge is drain out completely. The depth of manhole exc. 1metre but n.exc 2metre. |
| 7 | Cleaning manhole with spades or bucket taking out sludge manhole and disposed off aside by burying the entire sludge under ground in a pit of suitable size by putting earth on it. Again use water with bucket and put into manhole to clear the sludge and ensure the sludge is drain out completely. The depth of manhole exc. 2metre but n.exc 3metre. |
| 8 | Cleaning of septic tank any capacity, by bailing/removing out sediments, sludge etc.,by using vehicle mounted with compressor and sucker tank with covered container and washing wall/floor surface with fresh water all as specified and as directed. Note:- The extract of water & sludge to be taken away far from the MOD land and the volume of sludge obtained from cleaning measured from size septic tank and compared/check with tank size of sucket tank. |
| 9 | Excavation in soft/loose soil in trenches to the required width and depth to remove the damaged sewage lines of 150mm internal dia pipe by demolition of hanuching concrete to the pipe (one length 0.60m) and supply & fix new 150mm internal dia DWC pipe (one length of 60cm) including jointing with existing line, returning filling of soil, removal of surplus soil including temporarily plugging the adjacent manholes etc., complete all as specified and as directed. |
| 10 | All as per Item No 9.00 described here in before but for 200mm internal dia pipe. |
| 11 | Making arrangement of scaffolding in the shafts cutting holes around the bends, tees, junctions any description in the leakage/seepage and making good the cut portion with CM 1:3 or PCC 1:2:4 including finishing the portion with two coats of acrylic emulsion paint complete all as directed. |
| 12 | Making arrangement of scaffolding in the shafts/roof slab/chujjah, parapet / spot/ location of weed growth removing the weed including its root, making good with CM 1:3 or PCC 1:2:4 (12.5mm graded aggregate)including two coats of acrylic paint with primer all as specified |
| 13 | Cutting into existing manholes for connecting new pipe, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 finished and reforming benching as required for internal dia of pipe 100mm, complete all as directed and as specified. |
| 14 | Cutting into existing manholes for connecting new pipe, cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete (1:2:4) type B1 finished and reforming benching as required for internal dia of pipe 150mm, complete all as directed and as specified. |
| 15 | Excavating in trenches soft /loose soil, n exc 1.5 m wide and n exc 1.5 m in depth for foundation, trench for drain pipes etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n.exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed. |
| 16 | M&L for lowering, laying and jointing double wall corrugated pipe of 150mm dia in trenches for non pressure underground drainage and sewarage applications of SN-8 class and joining the same in to mahole complete all as specified and directed. Make:- Astral, Supreme, SFME or equivalent as approved by GE |
| 17 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils complete all a specified and directed. |
| 18 | Removing excavated material n exc. 50m and depositing where directed at a level n exc. 1.5m complete all as specified and directed. |
| 19 | Taking out old unserviceable PVC Pipe of size 75mm & 110mm and 150 mm from trenches and walls with all fitting incl. necessary excavation RFR and removal upto 250 mtrs complete all as specified and directed. |
| 20 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 21 | S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 22 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, fixed to walls complete all as specified and directed. |
| 23 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints, laid in trenches or in floors complete all as specified and directed. |
| 24 | S&F in repair 110mm dia PVC (SWR) bend with oval access door. |
| 25 | S&F in repair 75mm dia PVC (SWR) bend without oval access door. |
| 26 | S&F in repair 110mm dia PVC (SWR) branch piece (single Y) equal or unequal with oval access door. |
| 27 | S&F in repair 75mm dia PVC (SWR) branch piece (single Y) equal or unequal with oval access door. |
| 28 | Demolition of reinforced cement concrete concrete (reinforcement cut as required to facilitate demolition) of any description and in any position not otherwise specifically provided for complete all as specified and as directed. |
| 29 | Demolition of Precast Concrete work/ precast concrete block wall built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed. |
| 30 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specially provided for complete all as specified and directed |
| 31 | M & L for Pre-cast cement concrete solid block masonry using PCC (1:3:6) , Type C-1(using 20 mm stone agg) , exc10 cm in width and setting in CM( 1:4) complete all as specified and as directed. |
| 32 | M&L Rendering 15mm thick in fair faces of PCC block wall or concrete surfaces in CM(1:4) finished even & fair without using extra cement all as specified and directed. Note :- Water Proofing compound shall be paid separately |
| 33 | Material and labour for precast cement concrete in (1:2:4) type B1 (using 20mm graded stone aggregate) set in cement mortar 1:6 as in landings, cover slabs chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain face including necessary form work complete all as directed. |
| 34 | Material and labour for cement concrete (1:3:6), type C1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, water troughs and the like including weathering, slightly rounded or chamfered angles and throating, as directed., including necessary form work all as directed. |
| 35 | Material and labour for mild steel deformed TMT bars 6 to 8 mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clip complete all as specified and as directed. |
| 36 | Material and labour for Mild steel bars TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookingends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips complete all as specified and directed. |
| 37 | M&L PCC (1:4:8) Type -D2 (using 40 mm graded stone aggregate) in foundations, filling and mass-concrete all as specified |
| 38 | M & L PCC ( 1:3:6) Type C2 (using 40 mm graded agg)in surface channel, manhole and drain all as specified and directed |
| 39 | Supply only Liquid water proofing compound ISI marked etc., complete all as specified and as directed. (Note : WPC may apply as per manufactures instructions) |
| 40 | M&L 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified and directed. |
| 41 | S&F in repairs PVC flexible connections 15mm dia 600mm long with brass checknuts |
| 42 | S&F 32mm waste coupling, brass, chromium plated for glazed ware sinks and basins etc, with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed in repairs complete all as specified and directed. |
| 43 | S&F 40mm wastecoupling, brass, chromium plated for glazed ware sinks and basins etc, with long screwed shanks and fly nuts, flange end bedded in red lead cement and other end fixed in repairs complete all as specified and directed. |
| 44 | S&F in repair SS Grating round of 100mm size complete all as specified and directed. |
| 45 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground Concrete, brick work, masonry, etc. complete all as specified and directed. |
| 46 | Dismantling fencing wire mesh any type. |
| 47 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in & raming earth/ broken rubble mixed with earth around, in layers n. exc. 25cm, watering, & removing surplus soil to a distance n exc 50m & making good surface in soft/loose soil. |
| 48 | M&L PCC in foundations, filling and mass-concrete type B2 (1:2:4) using 20 mm graded stone aggregate all as specified. |
| 49 | S&F MS framed work such as fencing post including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 all as specified |
| 50 | Supply only MS flat iron as in fillets for securing wire mesh including all necessary drilling, bolting or riveting etc., and similar work confirming to Fe-410 W(Gde-E-250) quality-A complete all as specified and directed. |
| 51 | M&L PVC coated GI chain link fencing 3.5mm dia with 50mm x 50mm mesh including fixing of MS line wire / rod, flat iron & machine made hexagonal or square head bolts to fencing posts complete all as specified.(supply only of MS rod and bolts will be measured and paid seperately) complete all as specified and directed. |
| 52 | Supply only mild steel screw bolts n exc 12 mm dia machine made with hexagonal or square head at one end and screwed the other or screwed both ends for fixing of chain link fencing all as specified and directed. |
| 53 | Preparing new steel or iron surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed. |
| 54 | Dismantling Asbestos Cement Corrugated or Semicorrugate in Roof covering, complete all as specified and directed. |
| 55 | S&F for pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as specified.(Note : Height of the bldg up to G+3 storey including necessary safety arrangements) etc., complete all as specified and as directed. |
| 56 | S&F for Pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws as in ridges, hips, valley gutter, drip, and straight flashing all as specified and as directed.(Note : Height of the bldg up to G+3 storey including necessary safety arrangements) etc., complete all as specified and as directed. |
| 57 | S&F Aluminium flat iron work in wind ties 40x6mm size fixed with 50mm/ 75 mm aluminium self staging screws with integral EPDM washer screwed in roof covering all as directed.(Note :- Height of the bldg up to 15 mtrs including necessary safety arrangements) etc., complete all as specified and as directed. |
| 58 | Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed. |
| 59 | M&L for stainless steel (Grade 304) railing made of hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (where ever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories &stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of floor or the side of waist slab with suitable arrangement. etc., complete all as specified and as directed. (considered for Railing on balcony /staircase portion at any postition) |
| 60 | M&L for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc.conforming to Fe.290.Gde-E-165 etc., complete all as specified and as directed. |
| 61 | M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment confirming to Fe 410 -W (Gde- E- 250) quality- A etc., complete all as specified and as directed. |
| 62 | M&L precast cement concrete block masonry with solid block, exc 10cm in width in PCC type C-1, 1:3:6 (using 20mm graded stone aggregate) set in CM (1:6) etc., complete all as specified and directed. |
| 63 | M&L for rendering 5 mm thick in cement mortar 1:4 over a backing coat of 10mm thick in CM 1:6 (Total 15 mm thick) on concrete or brick masonry surfaces including mixing water proofing compound as per manufacurers instructions and finishing the top surface even and fair etc., complete all as specified and directed. |
| 64 | M&L Hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers n exc. 15cm thick, watered and rammed to a true surface complete all as specified and directed. |
| 65 | M & L for 25 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded aggregate as in Sub base for flooring/levelling coarse, sunken floor etc complete all as specified and as directed. |
| 66 | Material and labour for 75mm thick PCC (1:3:6) type C2 using 40mm graded aggregate as in plinth protection including finishing even and smooth with using extra cement, complete all as specified and as directed. |
| 67 | M&Lfor virtified ceramic tiles 10mm thick (square/ rectangular) polished heavy duty vertified tiles 400x400 size in floors, steps, raisers, etc,set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 20 mm thick screed bed in CM (1:4) complete all as specified and directed. |
| 68 | M&L for preparation of old plastered surface and applying one coat of 100% premium acrylic emlusion paint having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of WHITE COLOUR with silicon additives coat applied @1.67litre/10sqm over complete all as specified and as directed.Note: Asian Paints( Apex Ultima), Berger (weather coat Long life Fiexo) Nerolac (Excel Total), Shalimar Paints (Weatherpro+Super Luxury Emulsion) The rate inclusive of scaffolding at any height |
| 69 | M&L for preparation of old plastered surface and applying one coat of 100% premium acrylic emlusion paint (company depot tinted) having VOC less than 50gm/litre and UV resistance as per IS 15489-2004, Alkali & fungal resistance, dirt resistance exterior paint of with silicon additives coat applied @1.67litre/10sqm over complete all as specified and as directed.Note: Asian Paints( Apex Ultima), Berger (weather coat Long life Fiexo) Nerolac (Excel Total), Shalimar Paints (Weatherpro+Super Luxury Emulsion) The rate inclusive of scaffolding at any height Please Enable Macros to View BoQ information |