| 1 | De-watering & cleaning of septic tanks, manhole, sludge chamber etc. by pumping out sludge water manually or mechanically including cleaning of shrubs/bushes vegetation 2.50m around the septic tank & the like and making good to usable condition of the same complete all as specified and directed by the Eng-in-charge complete all as specified & directed. |
| 2 | Cleaning of sludges/silt from Nahani trap / floor trap including roding CI pipe from Nahani trap / floor trap to gully trap etc in position including removing of rubbish/sludge to a distance exceeding 250m not exceeding 500m all as specified and directed. |
| 3 | Cleaning the blockage in IWC, EWC, including roding CI pipe after opening the oval asses door of CI bend C1 branch piece (T) etc upto first MH and placing the existing oval access door in original position including removing the rubbish/sludge to a distance exceeding 250m not exceeding 500m all as specified and directed. |
| 4 | Systematicaly cleaning and desilting of pipe sewers of any type and upto 200 mm dia including man holes and gully trap of any size and depth by passing knots, bambboo, kamti and disc of required size, pumping out liquid waste/ sewage, plugging diverting the flow in the drain, if necessary and stacking the removed silt/ sludge in deposits as directed including taking precautionary measures such as safty belts, dry cells, torch for lighting in side the manholes and drain etc, sprinkling bleaching powder on the silt/ sludge removed to avoid bad smell and disposal of silt out side MD land complete all as specified and directed |
| 5 | Cleaning of drains (open) including getting out depth up to 15 cm average of all vegetation, foreign materials, silt etc from drain all as directed by Engineer-in-Charge. |
| 6 | Cleaning of drains by destiling mud, vegetation, debries waste materials depositets etc, cleaning/removing manually/mechanically up to a depth of 60 cm and removing the materials outside md land |
| 7 | Cleaning carefully (with fresh water) the blockage in CI / PVC Pipe 75mm dia pipe on walls & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M all as directed by Engineer-in-Charge. |
| 8 | Cleaning carefully (with fresh water) the blockage in CI / PVC Pipe 110mm dia pipe on walls & ensure all blockage perfectly cleared including necessary scafolding up to a height of 20.00M all as directed by Engineer-in-Charge. |
| 9 | Taking down Cement Plaster of any description on brick or stone walls or concrete surfaces including raking out joints, hacking for key, scrubbing down with water etc complete all as specified and as directed.. |
| 10 | Demolition of Precast Concrete work/ precast concreteblock built in Cement Mortar including all quoins arches pillars etc complete all as specified and as directed. |
| 11 | M & L for Pre-cast cement concrete block masonry using PCC, Type C-2 solid blocks, exceeding 10 cm in width and setting in Cement Mortar 1:6, straight or curved on plan exceeding 6 m mean radius complete all as specified and as directed. |
| 12 | M & L for PCC 1:4:8 with type D2 using 40 mm graded crushed stone aggregate as in filling, foundation and mass concrete |
| 13 | M & L for rendering 15 mm thick In cement mortar 1.4 on concrete or brick masonry surfaces and finishing the top surface even and fair complete all as specified and as directed by Engineer-in-charge. |
| 14 | M & L for applying Two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15488:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm) ® over new surlaces complete all as specified and as directed by Engineer-in-charge.Make: Asian Paints (Apex Ultima), Berger (Weathercoat Long Life Flexo) Nerolac (Excel Total), Shalimar Paints (Weatherpro Super Luxury Emulsion) |
| 15 | M&L for preparation of old steel surfaces of any description over 10cm in width or girth not other wise described and applying two coats of synthetic enamel paint complete all as specified and as directed. |
| 16 | Dismantling wrought iron or mild steel work of any description |
| 17 | M & L for MS work such as fencing post and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) Mild steel Angles, bars, flats etc., including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290 Gde E-165 complete. |
| 18 | S&F Framed work such as grills, gratings gates , etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work con- forming to Fe.290.Gde-E-165 complete all as specified and as directed. |
| 19 | S&F in repairs 3.5mm dia GI chain link fencing PVC coated 50mmx50mm mesh including fixing of MS flate iron,rod & bolt to fencing post all as specified (Note:The supply only of flate,rod& bolts shall be measured seprately). |
| 20 | S & Fin repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) |
| 21 | S & F in repairs GI concentrina barbed tape wire fencing of dia exceeding 450 mm but not exceding 600 mm of coil when unstrectched to be provided on the top of compound wall not less than 6 (six) rounds per metre length of wall including clips as per manufacturer instructions completed all as dirceted |
| 22 | Supply only mild steel screw bolts of 11 to 15 mm diameter of shank (machine made) with hexagonal or square heads at one end and screwed the other, each screwed end to be fitted with washers and one hexagonal or square nut, exceeding 10 cm and not exceeding 15 cm. |
| 23 | Supply only MS bars 10mm dia for support to chain link fencing complete all as specified and as directed. |
| 24 | Supply only flat for support to chain link fencing complete all as specified and as directed. |
| 25 | Material and labour for applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer on steel surfaces of any description, over 10 cm width or girth, not otherwise described including preparing new steel surfaces complete ll as specified and directed. |
| 26 | Demolition of cement Concrete in ground floors and pavings n exc 15 cm thickness (below or above ground level) |
| 27 | M&L for PCC 1:2:4 type B1 (20mm graded aggregate) as in copings etc all as specified and directed |
| 28 | M & L PCC type C2 1:3:6 (40 mm graded agg)in surface channel and drain complete all as specified. |
| 29 | M&L for 100 mm thick PCC 1:2:4 type B2 (using 40mm graded aggr) as in path/hard standing and spike rolling to surface or making impressions of expanded metal, while the concrete is green all as specified and directed |
| 30 | M&L for 75mm thick PCC 1:3:6 type C-1 (20mm graded aggregate ) plinth protection /sub base and similar work all as specified and directed, |
| 31 | M&L 100 mm thick plain Cement concrete (1:4:8) type C-2 (using 40mm graded stone aggregate) in sub base of floor complete all as specified and as directed. |
| 32 | Supply and laying of 55 mm thick silicon moulded paver blocks of square shape with natural stone texture finish, made using high-strength concrete (M-30 grade or above), vibrated and compacted in precision moulds. The paver blocks shall have a uniform size and slip-resistant laying over 50 mm sand cushion all as completed as per Engineer-In-Charge. |
| 33 | M&L for precast cover slab factory made with 1:2:4 type B1 using 20mm graded stone aggregate size as per site requirement incl cost of use and waste of clean sawn wooden form work and reinforcement all as specified incl removal of existing unserviceable cover slab complete all as specified. |
| 34 | S & F in repairs Vitreous China Squatting Pan\\"Orissa pattern\\" size 580 mmx440 mm white with integral foot rest etc. ( excluding cistern and flush pipe)& Provision of concrete bedding and making good to floor all as specified and as directed. |
| 35 | Excavating post holes or similar holes, each not exceeding 0.5 Cu. M, getting out in soft/ loose soil, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as directed. |
| 36 | M&L PCC in foundations, filling and mass-concrete type C2 (1:3:6) using 40 mm graded stone aggregate all as specified. |
| 37 | Dismantling Floor, Hearth or Wall Tiling including cement mortar bedding [but not backing] and removing serviceable tiles to the stores and removing rubbish / debris of the premises complete all as specified and as directed. |
| 38 | M&L Providing and laying vitrified parking tiles of sizes (400X400) of 10-15 mm thickness conforming to IS 15622 in all colors and shades in outdoor floors and skirting meant for parking of cars and trucks, grouting the 3 mm width joints using epoxy grout mix of 0.70 kg of organic coated filler of desired shade including filling/grouting and finishing set and jointed in neat cement slurry and pointed in white or coloured cement to match over 15mm thick screed bed in CM 1:6 complete.all as sppecified and directed. |
| 39 | M & L for non skid Ceramic Tiles, Coloured, of size exceeding 0.11 Sq.m and not exceeding 0.18 Sq.m, 7 mm to 8 mm thick [Square or Rectangular] as in Floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match including screed bed or bedding layer of mortar 15 mm thick in Cement Mortar 1:4 complete all as specified and as directed. |
| 40 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft loose soil. Complete all as specified. |
| 41 | Returning, filling in, including spreading, leveling, watering and well ramming in layers n exc 25cm complete all as specified and directed. |
| 42 | Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5m above the starting point complete all as specified and directed. |
| 43 | M & L for lowering, laying and jointing double wall corrugated pipe of 150mm dia in trenches for non pressure underground drainage and sewerage pressure underground drainage and seeerage applications of SN-8 class and joining the same into the manhole complete as specified by the Engineer-in-Charge. Make : - Astral, Supreme, SFME or equivalent as approved by GE. |
| 44 | M & L for lowering, laying, laying and jointing double wall corrugated pipe of 110mm dia in trenches for non pressure underground drainage and sewerage pressure underground drainage and seeerage applications of SN-8 class and joining the same into the manhole complete as specified by the Engineer-in-Charge. Make : - Astral, Supreme, SFME or equivalent as approved by GE. |
| 45 | S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls |
| 46 | S&F110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints,fixed to walls. |
| 47 | S&F 75mm dia PVC (SWR) bend with oval access door |
| 48 | S&F 110mm dia PVC (SWR) bend /shoe without oval access door |
| 49 | S&F110mm dia PVC (SWR) branch piece (single Y)equal or unequal with oval access door |
| 50 | S&F in repair PVC (SWR) floor trap,plain with grating 110 mm with incl jointing with solvent cement . |
| 51 | S&F in repair 110 mm PVC nahani trap with grating incl jointing to waste pipe fixed in cement concrete type B1 (1:2:4). |
| 52 | S & F in repairs CP Graiting square /rounded 100 mm size without waste hole or with waste hole to insert waste pipe complete all as specified and directed. |
| 53 | M & L for attending to petty repair job to plumbing /internal water supply works such as repair to leaking bib taps/pillar taps/mixers/stop cocks/angle valves/float valves/concealed stop cick etc by tightening and providing washer,disc, spindle or any other minor accessories, repair to float valves, flushing cistern by minor adjustments, leaking water supply lines by tightening the GI fittings or refixing water supply or sanitary fixtures using thread/Teflon tapes with and including small GI fittings such as GI elbow, socket, union as required at site to make the system functional complete as specified and directed by Engineer-in-Charge.Note : (i) Each repair job shall be measured as one Job.(ii) Job involving replacement of taps /valves shall not be measured under this item.(iii) Contractor to provide one plumber with helper daily to report to JE(Civ) at 08 30 hrs for detailment of duty complaints and resubmit complaints slip to JE(Civ) in the evening at 5 p.m on daily basis.(iv) For non providng plumber recovery @ Rs 100.00 per hour with maximum Rs 800.00 per day. |
| 54 | S & F Steel rolling shutters, 1.25 mm thick lath gear operated type with bevel gear box and crank handle with out ball bearing, as specified including top cover, anchoring rod, hasp and staple and one shop coat of primer; erected in position as indicated, complete: push pull or manual type including taking down old unserviceable shutter complete all as specified and as directed.. |
| 55 | S & F in repair for rolling shutter removing the same with necessary greasing, and replaced minor parts like ball, bearing etc which reaquired to make serviceable complete all as specified and as directed by Engineer-in-Charge. Please Enable Macros to View BoQ information |