| 1 | Electrical Installation Work for all the rooms and corridors at the main building and also at the Annex building in the Statistics Department alongwith security lights under Kalyani University. |
| 2 | Supplying and fixing 415V, 125A TPN SFU with sheet steel enclosure on angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating..(Make L&T) (Ref:PWD Page No-D-3,Item No:4(a))(For Annex) |
| 3 | Supply & fixing 415V 200 A capacity MS (16 SWG) Busbar Chamber having dimension of (500x150mm) to be fixed on iron frame on wall consisting of 4 nos copper bars of size (4x40x5mm). The same BBC should have a separate cubicle at one end consisting 3 nos 200 A capacity porcelain cut out fuse unit & one nutral bar to receive the service cable including connecting the cut out fuse units with the BBC by S/F PVC insulated copper wire duly socketed at both ends incl. earthing attachment & painting .[Ref:PWD Page No-D-13,Item 19(b)](For Annex) |
| 4 | Supplying and fixing 6 Way double door Horizontal TPN MCB Distribution board Enclosure (8GB32202RC06) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make : Siemens or equivalent as approved by EIC.)i) 415 V, 100 A FP Isolator ....................... 1 No.ii) 415 V 63 A TP MCB .................. 03 Noiii) 240 V, 6-32 A (Breaking Capacity 10 kA & 'C' Characteristics) ......... 09 Nos.[Ref:-PWD Page No : D - 10, 5, 6 Item No : 14, 6, 7](Two for main building one for Annex Building) |
| 5 | Supplying and fixing double-door (2+10) Way SPN MCB Distribution Board Enclosure (8GB32102RC12) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make : Siemens or equivalent as approved by EIC.)i) 240 V, 40 A DP Isolator .............. 1 No.ii) 240V, 6 - 32 A SP MCB (Breaking Capacity 10 kA & 'C' Characteristics)................. 10 Nos.Ref:-PWD Page No : D - 10, 5, 6 Item No : 13, 6, 7 |
| 6 | Supplying and fixing double-door (2+4) Way SPN MCB Distribution Board Enclosure (8GB32102RC06) with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment. (Make : Siemens or equivalent as approved by EIC.)i) 240 V, 40 A DP Isolator .............. 1 No.ii) 240V, 6 - 32 A SP MCB (Breaking Capacity 10 kA & 'C' Characteristics)................. 8 Nos.Ref:-PWD Page No : D - 10, 5, 6 Item No : 13, 6, 7 |
| 7 | Supplying and fixing 20 mm size PVC Rigid Conduit 'FR' [Precision Make]on wall, ceiling with saddles and other accessories as required and mending good damages to building works.[Ref:PWD Page No-E-16,Item No-7(a)]NB - Should be use Precision make shaddle & the saddles should be fixed at 325mm interval . |
| 8 | Supplying and fixing 25 mm size PVC Rigid Conduit 'FR' [Precision Make]on wall, ceiling with saddles and other accessories as required and mending good damages to building works.[Ref:PWD SOR Page No-E-16,Item No-7(b) ]NB - Should be use Precision make shaddle & the saddles should be fixed at 325mm interval . |
| 9 | Cutting Channel of sizes (40 mm x 40 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge as per office supply pipe sample 19 mm bore, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG including supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles for the following sizes Pipes - **a)19 mm dia 3 mm thick polythene pipe without earth continuity wire(For circuit drawing & Point wiring / as per requirement of Job / as per instruction of EIC) NB - All rubbishes should be removed from work site & also Tee & Elbow should not be use in the conceal pipe,continuity wire.[Ref:PWD SOR Page No : E - 3 Item No : 6(a)] |
| 10 | Cutting Channel of sizes (43 mm x 43 mm) on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge as per office supply pipe sample 25 mm, 3 mm thick Polythene pipe by means of anchoring chemical (Hilti/Sika) and GI 'U' hooks of 8 SWG including supplying and drawing 18 SWG GI wire as Fish wire and mending good damages to original finish by using own tools and tackles for the following sizes Pipes - **a) 25 mm dia 3 mm thick polythene pipe without earth continuity wire(For circuit drawing & Point wiring / as per requirement of Job / as per instruction of EIC) NB - All rubbishes should be removed from work site & also Tee & Elbow should not be use in the conceal pipe,continuity wire.[Ref:PWD SOR Page No : E - 3 Item No : 6(a)] |
| 11 | Supply & drawing 1.1 KV single core stranded 'FR'/'FRLSH PVC insulated & unsheathed copper wire (Make Gloster or Brand approved by EIC) through prelaid polythene pipe and by the prelaid GI fish wire/PVC rigid conduit 'FR' (Precision make) pipe on wall incl. making necy. connection as required & mending good the damages g-1)4x126/0.4 (16 sqmm) + 2x80/0.4 (10 sqmm) as ECC**NB- Should be maintain colour combination of Circuit Wire (Ref:PWD SOR Page No-E-9 Item No: 1(g1 ) |
| 12 | Supply & drawing 1.1 KV single core stranded 'FR'/'FRLSH PVC insulated & unsheathed copper wire (Make Gloster Brand approved by EIC) through prelaid polythene pipe and by the prelaid GI fish wire/PVC rigid conduit 'FR' (Precision make) pipe on wall incl. making necy. connection as required & mending good the damages B)2x84/0.3 (6 sqmm) + 1x56/0.3 (4 sqmm) as ECC ( TPNDB to SPNDB) [Each Floor]**NB- Should be maintain colour combination of Circuit Wire (Ref:PWD SOR Page No-E-9 Item No: 1(z ) |
| 13 | Supply & drawing 1.1 KV single core stranded 'FR'/'FRLSH PVC insulated & unsheathed copper wire (Make Gloster ) Brand approved by EIC through prelaid polythene pipe and by the prelaid GI fish wire/PVC rigid conduit 'FR' (Precision make) pipe on wall incl. making necy. connection as required & mending good the damages (v)2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC **NB- Should be maintain colour combination of Circuit Wire (Ref:PWD SOR Page No-E-9 Item No: 1(v ) |
| 14 | Supply & drawing 1.1 KV single core stranded 'FR'/'FRLSH PVC insulated & unsheathed copper wire (Make Gloster or Brand approved by EIC) through prelaid polythene pipe and by the prelaid GI fish wire/PVC rigid conduit 'FR' (Precision make) pipe on wall incl. making necy. connection as required & mending good the damages t)2× 2.5 sqmm + 1× 1.5 sqmm.(For Power Plug Board and computer board )**NB- Should be maintain colour combination of Circuit Wire (Ref:PWD SOR Page No-E-9 Item No: 1(s ) |
| 15 | Supply & drawing 1.1 KV single core stranded 'FR'/'FRLSH PVC insulated & unsheathed copper wire (Make Gloster or Brand approved by EIC) through prelaid polythene pipe and by the prelaid GI fish wire/PVC rigid conduit 'FR' (Precision make) pipe on wall incl. making necy. connection as required & mending good the damages a)3x 22/0.3 (1.5 sqmm)**NB- Should be maintain colour combination of Circuit Wire (Ref:PWD SOR Page No-E-9 Item No: 1(s ) |
| 16 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes.i) For 2.5 sq mm Copper Wire. [Ref:PWD SOR Page No : F - 5 Item No : 9(i)] |
| 17 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes.i) For 4 sq mm Copper Wire.[Ref:PWD SOR Page No : F - 5 Item No : 9(ii)] |
| 18 | Finishing of the PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., includingsupplying sockets, tapes.i) For 6 sq mm Copper Wire.[Ref:PWD SOR Page No : F - 5 Item No : 9(iii)] |
| 19 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.i) For 10 sq mm Copper Wire.[Ref:PWD SOR Page No : F - 5 Item No : 9(iv)] |
| 20 | Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes. i) For 16 sq mm Copper Wire.[Ref:PWD SOR Page No : F - 5 Item No : 9(v)] |
| 21 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR'/'FRLSH' PVC insulated & unsheathed copper wire [ Make:Gloster / Polycab / Finolex (Gold) or as equivalent approved by EIC] After Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes**NB- Should be maintain colour combination of Circuit Wire, partly in 20 mm/ 25 mm size PVC rigid conduit 'FR' (Precision make) Medium (MMS) [for ceiling portion only] and in 19 mm bore, 3 mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded ''FR'/'FRLSH' PVC insulated & unsheathed copper wire [ Make: Gloster / Finolex (Gold) or as equivalent approved by EIC] , partly for ECC, to light/fan/call bell points with 6A 1 way Piano Key type switch (Anchor Make) fixed on MS CRC sheet metal (16 SWG) switch board (as per office supply sample) embedded on wall complete with 2 no. “Ph & N” copper bar on Double Chair incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages tooriginal finish [only PVC Rigid Conduit on ceiling and remaining portion concealed]Avg Run- 5 Mtr(Ref:PWD SOR Page No-E-15 Item No: 5.a) |
| 22 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR'/'FRLSH' PVC insulated & unsheathed copper wire [ Make:Gloster / Polycab / Finolex (Gold) or as equivalent approved by EIC] After Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes**NB- Should be maintain colour combination of Circuit Wire, partly in 20 mm/ 25 mm size PVC rigid conduit 'FR' (Precision make) Medium (MMS) [for ceiling portion only] and in 19 mm bore, 3 mm thick polythene pipe [for horizontal & vertical run embedded in wall], with 1x22/0.3 (1.5 sqmm) single core stranded ''FR'/'FRLSH' PVC insulated & unsheathed copper wire [ Make: Gloster / Finolex (Gold) or as equivalent approved by EIC] , partly for ECC, to light/fan/call bell points with 6A 1 way Piano Key type switch (Anchor Make) fixed on MS CRC sheet metal (16 SWG) switch board (as per office supply sample) embedded on wall complete with 2 no. “Ph & N” copper bar on Double Chair incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages tooriginal finish [only PVC Rigid Conduit on ceiling and remaining portion concealed]Avg Run- 6 Mtr(Ref:PWD SOR Page No-E-15 Item No:5.b) |
| 23 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) singlecore stranded 'FR'/'FRLSH' PVC insulated & unsheathed copper wire [ Make:Gloster / Finolex (Gold) or as equivalent approved by EIC] After Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes**NB- Should be maintain colour combination of Circuit Wire,partly in 20 mm/25 mm size PVC rigid conduit 'FR'(Precision make) [for horizontal run & above false ceiling portion only] and in 19mm bore, 3mm thick polythenepipe [for vertical run embedded in wall], with 1x22/0.3 (1.5sqmm) single core stranded ''FR'/'FRLSH'' PVC insulated & unsheathed copper wire [ Make:Gloster / Finolex (Gold) or as equivalent approved by EIC]for ECC, to light/fan/call bell points with Piano Key type switch (Anchor Make) fixed on MS CRC sheet metal (16 SWG) switch board on wall complete with 2 no. “Ph & N” copper bar bar on Double Chair incl. bakelite/ Perspex top cover 3 mm thick and incl. 175x100x65 mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finishAverage Run 6 Meter [PVC Rigid Conduit only for horizontal run & above false ceiling and vertical run concealed](Ref:PWD SOR Page No-E-16 Item No:6) |
| 24 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'/'FRLSH' PVC insulated & unsheathed copper wire [ Make: Gloster / Finolex (Gold) or as equivalent approved by EIC] After Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes**NB- Should be maintain colour combination of Circuit Wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to light/fan/call bell points with 6A 1 way Piano Key type switch (Anchor Make) fixed Piano key type switch fixed /embedded on MS CRC sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick)flushed in wall incl. mending good damages to original finish(a)2x22/0.3 (Ph. & N) and 1x22/0.3 as ECCAverage run 6 mtr(Ref:PWD SOR Page No-E-9 Item No:2.a(i)] |
| 25 | Distribution wiring in 2 x 22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make), with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with Piano Key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB Embeded on wall or surface complete with 2 no. suitable size “Ph & N” copper bar incl. bakelite/Perspex (wall matching color) top cover 3 mm thick and incl. 175mmx100mmx65mm inspection box, making earthing attachment, painting the MS box andmending good the damages to original finish.Average run 6 mtr(Ref:PWD SOR Page No-E-14 Item No: 2(a ) |
| 26 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'/'FRLSH' PVC insulated & unsheathed copper wire [ Make: Gloster / Finolex (Gold) or as equivalent approved by EIC] After Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes**NB- Should be maintain colour combination of Circuit Wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A/6A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch boardwith bakelite/perspex (wall matching colour) top cover (3 mmthick) flushed in wall incl. incl. painting the MS box and mending good the damages to original finish) On Board(Ref:PWD SOR Page No-E-10 Item No:4.a(i)] |
| 27 | Distn. wiring in 22/0.3 (1.5 sqmm) single core stranded 'FR'/'FRLSH' PVC insulated & unsheathed copper wire [ Make: Gloster / Finolex (Gold) or as equivalent approved by EIC] After Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes**NB- Should be maintain colour combination of Circuit Wire in 19 mm bore, 3 mm thick polythen pipe complete with all accessories embedded in wall to 240 V 5A 3 pin plug point incl. S&F 240 V 5A/6A 3 pin flush type plug socket & piano key type switch (Anchor make) incl. S&F earth continuity wire, fixed on sheet metal (16 SWG) switch board with bakelite/perspex (wall matching colour) top cover (3 mm thick) flushed in wall incl. incl. painting the MS box and mending good the damages to original finish) a)2x22/0.3 (Ph. & N) and 1x22/0.3 as ECC [6A Switch+ Socket Combo for Charging]Average Run 1.5 Mtr(Ref.PWD SOR Page No-E-10 Item No:4(a)ii] |
| 28 | Supply & Fixing 240 V, 20 A plug socket (Anchor make or Brand approved by EIC), without plug top and switch, on 100 mm x 100 mm x 65 mm sheet metal switch board with bakelite/perspex top cover by screws after making housing for combined plug switch by cutting bakelite/perspex top cover and making necy. connections with PVC wire and earth continuity wire etc. [For AC Power Plug Board at various offices, EV charging board and Annex Building ](Ref: PWD SOR Page No-E-5,Item No-15(b) |
| 29 | Supply & Fixing 240 V, 4 nos. 6A, plug socket with separate 4nos. 6 A Piano key type switch, indicator & 16A kit-kat flush type fuse (Anchor Make or Equivalent Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 240x200x65mm MS (16SWG) switch board and bakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.[ Charging Board](Ref.PWD SOR Page No-E-7,Item No-23 ) |
| 30 | Supply & Fixing 240 V, 3 nos. 6A, & 1 no. 20A plug socket with separate 3 nos. 6 A & 1 no. 20A Piano key type switch, indicator (All Anchor Make) & 20A switch type SP MCB (Make Siemens or equivalent Brand approved by EIC) on sheet metal switch board embedded in wall incl. S &F 240x200x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3 mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required. [Computer Board](Ref:PWD SOR Page No-E-7,Item No-26 ) |
| 31 | Supply & Fixing Socket type fan regulator (Step type) (Anchor Make) on existing sheet metal switch board with bakelite/ perspex top cover by screw incl. making necy. connections etc.(Ref:PWD SOR Page No-E-6,Item No-18(b) |
| 32 | Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)[Ref: PWD SOR Page No-D-14 Item no. 29] |
| 33 | Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.[Ref: PWD SOR Page No-C-3 Item no. 21(a)] |
| 34 | Lowering and refixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. making necessary disconnection and connection as required.[Ref: PWD SOR Page No-C-3 Item no. 22] |
| 35 | Fixing only cabin fan on wall/ceiling by S&F rag bolts, nuts &washers (6 mm dia x 62 mm long) or as reqd. incl. S&F 24/0.20PVC insulated flexible copper wire 0.5 mt. length.[Ref: PWD SOR Page No-C-4 Item no. 29] |
| 36 | Fixing only starters (for Split AC Machine control) Concealed in wall after cutting the wall and making housing for the starter and mending good the damages to original finish .Direct online starter for 2 Ton ac Machine.[Ref: PWD SOR Page No-C-1 Item no. 7(a)] |
| 37 | Fixing only 30 cm (12\\") exhaust fan by anti rotating facility system nut bolts after grouting in wall making hole in wall and making good damages and smooth cement finish etc. as practicable as possible and providing necy. length of PVC insulated wire and making connection for exhaust of following diameter[Ref: PWD SOR Page No-C-4 Item no. 28(b)] |
| 38 | Supply & Fixing Aluminium louver shutter for 30 cm Exhaust fan (12\\") on wall with necy. bolts & nuts (6 mm dia x 62 mm long)[Ref: PWD SOR Page No-D-14 Item no. 32(a)] |
| 39 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works and also removing rubbises from work site .100 mm x 100 mm x 65 mm (Ref:PWD SOR Page No-E-4,Item No-11( a) |
| 40 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works and also removing rubbises from work site . 150 mm x 100 mm x 65 mm(Ref:PWD SOR Page No-E-4,Item No-11( b) |
| 41 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works and also removing rubbises from work site . 175 mm x 100 mm x 65 mm (Ref:PWD SOR Page No-E-4,Item No-11( c) |
| 42 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works and also removing rubbises from work site . 200 mm x 150 mm x 65 mm(Ref:PWD SOR Page No-E-4,Item No-11( d) |
| 43 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works and also removing rubbises from work site .240 mm X 200 mm x 65 mm(Ref:PWD SOR Page No-E-4,Item No-11( e) |
| 44 | Supplying & Fixing sheet metal inspection box (16 SWG) of the following sizes flushed in wall by housing the same after cutting brick wall incl. making earthing attachment, painting and mending good damages to building works and also removing rubbises from work site .240 mm X 240 mm x 65 mm(Ref:PWD SOR Page No-E-4,Item No-11( f) |
| 45 | Supply & Fixing bakelite / perspex top cover on existingInspection board by Brass screws100 mm x 100 mm x 65 mm (Ref:PWD SOR Page No-E-5,Item No-13( a) |
| 46 | Supply & Fixing bakelite / perspex top cover on existingInspection board by Brass screws 150 mm x 100 mm x 65 mm(Ref:PWD SOR Page No-E-5,Item No-13( b) |
| 47 | Supply & Fixing bakelite / perspex top cover on existingInspection board by Brass screws 175 mm x 100 mm x 65 mm (Ref:PWD SOR Page No-E-5,Item No-13( c) |
| 48 | Supply & Fixing bakelite / perspex top cover on existingInspection board by Brass screws 200 mm x 150 mm x 65 mm(Ref:PWD SOR Page No-E-5,Item No-13 ( d ) |
| 49 | Supply & Fixing bakelite / perspex top cover on existingInspection board by Brass screws 240 mm X 200 mm x 65 mm(Ref:PWD SOR Page No-E-5,Item No-12( e) |
| 50 | Supply & Fixing bakelite / perspex top cover on existingInspection board by Brass screws 240 mm X 240 mm x 65 mm(Ref:PWD SOR Page No-E-5,Item No-12( f) |
| 51 | Fixing only lamp(Ref:PWD SOR Page No-C-2,Item No-11) |
| 52 | Fixing only single /twin fluorescent light fitting complete with allaccessories directly on wall/ceiling/HW round block and suitablesize of MS fastener(Ref:PWD SOR Page No-C-2,Item No-14.b) |
| 53 | Fixing only fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports incl. S&F EI conduit, ball socket/socket type ceiling plate /Supports also U type GI clamp made with 31 mmx 3 mm GI flat and suitable size fastner (as per sample to be provided)and connecting the length of PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm) flexible copper wire of 1.10mt. length.(Ref:PWD SOR Page No-C-2,Item No-15) |
| 54 | Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.(Ref:PWD SOR Page No-C-2,Item No-16) |
| 55 | Fixing only bulk head or ceiling fitting on wall /ceiling by screws etc.[PWD Page No-C-2 Item no. 13] |
| 56 | Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building after grouting the wall for fixing the the bolts 13 mm dia x 150 mm long with anti rotating system with CC morter & S&F 2 nos U type MS clampmade with 40x6 mm MS flat with suitable bend for holding including making holes to building, S&F 40 mm dia GI pipe (ISI-Medium)(Make Bansal /Jindal) 1.50 mts./2.0 mts long arm bracket holding fabricated 2 nos U type 40 mm dia GI pipe ISI medium (Make Zindal/Bansal) Arm bracket 2.0 meter average length (0.7m+1.3m) Holding Fabricated MS clamp 40x6 mm Flat with suitable bend (120-130 degree)(as per office supply Sample),including drilling holes,nut bolts(13 mm dia 150 mm long) complete with anti rotating facility ,washer that projected from pole/ building complete also with 40 mm dia (ISI) medium pipe Zindal/Bansal etc as required , with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 3 core 1.5 sqmm industrial annealed copper cable and making connections as required and mending good damages to wall and painting.(Ref:PWD SOR Page No-C-3,Item No-19) |
| 57 | Supplying & Fixing GI waterproof type looping cable box size 200x150x100 mm deep having 4 mm thick with rubber gasket linning railway type mechanical locking arrangement comprising of one 250 V 15 A kit-kat fuse unit, one NL on porcelain insulator,(as per office supply Sample)fixed on wall in concealed /embeded or at pole with fabricated iron frame 40x6 mm flat for PCC/RCC/Tubular Pole ,one compression type brass cable gland for upto 2- core 16 sqmm and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug, on steel tubular pole near base, including S&F 40x6 mm thick, MS clamps with bolts, nuts etc. including painting with anticorrosive paint.[PWD Page No-H-5 Item no. H(5)] |
| 58 | Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers with Funnel incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below & restoring surface duly rammed by the following-By ISI-Medium 50 mm dia GI pipe (Make Bansal,Jindal)(Ref:PWD SOR Page No-G-1,Item No-2(a)) |
| 59 | Supplying & fixing earth busbar of galvanized (Hot Dip) MS flat 25 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.(Ref:PWD SOR Page No-G-2,Item No-4(a)) |
| 60 | Connecting the equipments body to earth busbar including S & F 25 mm x 6 mm galvanised (Hot Dip) MS flat on wall/floor with GI saddles /floor cutting/existing L hook aas required and connection to equipments incl.drilling holes, with bolts, nuts, washers etc.(Ref:PWD SOR Page No-G-3,Item No-5(d) |
| 61 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required : 80 mm dia (as per office supply sample)[PWD Page No-F-6 Item no. 11.(f)] |
| 62 | Supplying & fixing medium gauge GI Pipe ( ISI-Medium) Protection with necessary fittings and jointing metarials as required : 50 mm dia (as per office supply sample)[PWD Page No-F-6 Item no. 11.(d)] |
| 63 | Laying of cable upto 3.5 core 25 sqmm on wall/surface incl. S & FMS saddles with earthing attachment in 10 SWG GI (Hot Dip)Wire, making holes etc. as necy. mending good damages andpainting.[For Outdoor Light[(Ref:PWD SOR Page No-F-1 Item No:2(a)] |
| 64 | Laying of cable as below 3.5 core 25 Sq mm, after cutting floor/pavement/wall/ and making holes incl., embedding the cable at an average depth as below and mending good the damages to original finish incl. removing the rubbishFrom 2.5 sqmm to 35 sqmm at an average depth of 75 mm infloor/pavement/wall etc.[(Ref:PWD SOR Page No-F-3 Item No:5(i)] |
| 65 | Supplying and fixing 2 Core 6 sqmm compression type gland (Make:Dowels) complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables a (Ref:PWD SOR Page No-F-4 Item No:7(d) ] |
| 66 | Finishing the end of 2 Core 6 sqmm XLPE unarmoured cables by crimping method incl. supplying and fixing solderless socket(Dowels make), tapes, anticorrosive paste & jointing materials.(PWD SOR Page No-F-5)Item No:8(b) [xiv] |
| 67 | Supply and delivery of 2 core 6 sqmm 1.1 KV grade aluminium XLPE armoured cable (Make- Gloster )( Ref:Non Schedule Item ) |
| 68 | Supply of 4' 20W Single LED Aluminium T8 tube (LTT8) with in built driver and efficacy of 100 lm/W. type tube light fitting on High efficiency integrated LED Batten to create a sustainable lighting environment with surface/suspended mounting, complete with all acessaries directly on ceiling with HW round block & suitable size of MS fastener (Make: Crompton -Batten (ECO-I)-IGP161LT8-16 1 x T8, Tube-CRYSTA LTT8-20-865-2)( Ref:Non Schedule Item ) |
| 69 | Supply of 9 W LED Bulb (Make-Crompton 9 W B-27/E27 - CDL / W/t)( Ref:Non Schedule Item ) |
| 70 | Supply and delivery of 1200 mm sweep, single phase, 240 Volt, 50 Hz Ac Ceiling Fan including down rod, top and buttom canopy, capacitor etc. (Make- Usha Striker PWD ISI 1 Star(Safety wire & S1 Capacitor)( Ref:Non Schedule Items ) |
| 71 | Supply and delivery of 300 mm sweep(12''), single phase, 240 Volt, 50 Hz Ac,1420 rpm,80W Heavy duty Exhaust Fan including all accessories. (Make- EPC )( Ref:Non Schedule Items ) |
| 72 | Supply of recessed mounted LED 36 W 4000K dimension (mm) l |b | h =600 | 600 |60 low glare diffuser light on ceilling complete set.[Make:K-Lite Cat No:-KL-2281 )( Ref:Non Schedule Item ) |
| 73 | Supply and delivery of 4 Metal Blade 450 mm sweep, single phase, 240 Volt, 85 W 50 Hz Ac Wall Fan including all accessories . (Make- EPC )( Ref:Non Schedule Item ) |
| 74 | Supply of control panel suitable for 2 Ton AC Machine,Relay Range 13 - 22 A comprising of DOL starter to be Concealed on wall incl making connection & necy earthing attachment. (Make -L&T MU-2P Single Phase Starters-CS90319KODO )( Ref:Non Schedule Item ) |
| 75 | Supply and Delivery 100 W LED Avenue 100-526 x 174 x 90-100W-5700K-Type IIClear Toughened Glass-Ø60 - Ht.100mm-Powder Coating-Graphite Grey-5 Years Code: 24392-009-100-57-T2-000-L0310-PCF-004-005.(Make-K-lite Avenue )( Ref:Non Schedule Item ) |
| 76 | Dismantling the existing working / nonworking lines & their accessories as per requirement / as per availablity at site during execution of job like worn wirings , tube light , ceiling fans , switch board , power board , SPN MCB DB / Fuse DB , Main Switch , Changeover switch , main panels etc after dis-connecting the line for making space of new installation accessories including deposited the all dismantled materials should be deposited to the university store . NB - For deposition of the dismantled materials to the KU store no extra cost will be paid.Reference:Tender Notice No WD/3T-1/594 ( Ref:Non Schedule Items ) |
| 77 | 18% GST |
| 78 | 1% CESS Please Enable Macros to View BoQ information |