| 1 | Supply , Installation , testing and commissioning of standard 4.0 Mtr. High (above ground) hot dip galvanized (grading of galvenisation average 70 micron or better as per IS 2629 or equivalent) pole, with stiffener, chain, allen bolt, foundation, single arm bracket, template, nut and bolts galvanized, factory finish base plate of size 200x200x12mm etc complete as required. The pole shall be made of 3mm thickness sheet with tolerance of +/- 5%. The column shall also be provided with flush door at the bottom with proper strengthening to the cutout of the door opening, a junction/loop box with heavy duty 3 phase , 32 Amp. connector with 16A DP MCB including all accessories complete as required directed by E/I(Make - Bajaj/ Transrail/valmount) (AOR) |
| 2 | Supply anf fixing 2.40 to 3.0 Mtr. Decoravive Poles made of square pipe duly CNC cut illuminated customised design fitted with Led Module and Acrylic /PC. 50watt CNC cut portion and 4x2.5 watt LED Moduled on Top. Pipe dia 200x200x4mm, Base Plate 300x300x10 mm (Total wattage of pole 150 watt)ncluding all accessories complete as required directed by E/I. (Make - VAK/NERI/Mayfair/K-lite/ Kesslec) |
| 3 | Errection of matelic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : graded stone aggretage 40 mm nominal size) foundation including excavation and refilling etc. as required bove 4.5 mtr and upto 6.50 mtr DSR Electrical 2018/I No. 11.3.1 |
| 4 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in existing surface / recessed steel / PVC conduit as required 3x1.5sq.mm DSR2018 Item .no.1.17.3 |
| 5 | S/Fixing of LED Street Light fitting having die cast Aluminium body and difuser with driver set suitable for 110 to 130 watt. Confirming to IP-66 and above protection. Complete in all respects. (PS No. 1424) Cat-AAA (Make - LT/Bajaj/ Havells/ Crompton/Philips/Wipro) |
| 6 | Supplying and laying of aluminium conductor PVC insulated armoured, served, sheathed cable 1100 Volts grade at a depth of 750 mm. below ground level over a cushion of 75 mm. thick sand alround and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. Clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respects. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. (Polycab, KEI, Havell's make) |
| 7 | (1) 16 Sq.mm. 4Core (PS No. 501) |
| 8 | (2) 50 sq mm 3 ½” core |
| 9 | S/F of Palm or Pin type copper tin plated cable socket (lugs) to the cable lead insulation with tape and making connections complete as per direction of E/I. P.S. No. 504 |
| 10 | 1- 16 Sq.mm. |
| 11 | 2- 35 Sq.mm. |
| 12 | 3- 50 Sq.mm. |
| 13 | S/Laying of 90 mm dia (OD 90 mm & ID 76 mm nominal) size of (DWC) HDPE Pipes ISI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part-II complete with filling and cutting, jointing etc. direct in ground ( 75 cm below ground level) including excavation and refilling the trench pat excluding sand cushioning and protective covering etc. Complete in all respects. Rex/Duraline/ Time/CPE make. as per DSR 2018 item no. 14.16.2 page no. 49 |
| 14 | Supply and fixing of 40 Amp TPN capacity of automatic street light cubical control panel painted with anti corrosive alkali and acid proof paint crossing of time switch TSO 100 series with contractors, HRC fuse, isolating swtich metering instrument & instrument box with CTs etc. in case of TPN, Complete in all respects. as per PS No. 807F |
| 15 | Demolishing cement concrete manually/ by mechanical means including disposal of material with in 50 Mtr. Lead as per direction of E/I. Nominal concrete 1:3:6 or richer mix(i/c equivalent design mix) (DSR civil I No. 15.2.1/P-253) |
| 16 | Providing and laying in position cement concrete 1:3:6 (1 cement : 2 coarse sand : 6 graded stone aggregate 40 mm nominal size) in foundation of pump, DG set etc including form work etc as required. (DSR Elect. 2018/14.9/48) |
| 17 | Dismantling of pole/Street Light standard /strut embedded in cement concrete foundation etc. as required (Electrical DSR-2018/item no. 12.42 P-46) |
| 18 | Errection of metallic pole of following length in cement concrete 1:3:6 ( 1cement:3 coarse sand : 6 graded stone aggregate 40 mm nominal size) foundation including excavation and refilling etc. as required above 10.0 mtr and upto 12 mtr (Electrical DSR 2018 I. n. 11.3.4 ) |
| 19 | Supply and burrying of 75 mm Dia 3 Mtrs. Long Electrode casted with maintenance free, conductive concrete, non corrosive mixture ( Ultra low Resistive carbon 0.001 ohm/Mtr) in the ratio of 3:1:1 (marconite : cement : water) on M.S. Rod with hole (16 mm diameter X3 Mtrs ) will be vertically installed for earthing with 1Mtr G.I strip (25 mm X 2.5mm) connected with SS nut bolt. The earth electrode will be installed into the 100 mm pit up to 3000 mm depth. noraml soil will be used as backfill material. Make : As approved in U.P.P.W.D & C.P.R.I. Certified. (PS no 729(c) P-144) |
| 20 | Supply and laying of 25mm x 3mm G.I. strip from earth electrode directly in the ground as required complete in all respect.(PS no 716/ P-138) |
| 21 | Cutting road and making good the same including supply of extra quantities of materials i.e. aggregate, moorum screening, red bajri and labour required (AOR) |
| 22 | a) Bituminous Portion (AOR) (2265.0+18% gst) |
| 23 | b) Water Bound Macadam (AOR) (1400.0+18% gst) |
| 24 | Taking out existing CC interlocking paver blocks form foothpath / Central verge including removel of rubbish etc. disposal of unserviceble material to the dumping ground, For which payment shall be made sepatately and stacking of serviceable meterial within 50 metre lead as per direction fo Engineer-in-Charge D.S.R/S.O.R 16-83 |
| 25 | Laying old cement cocrete interlocking paver blocks of any design/Shape laid in required line , level curvature, colour and pattern over and including 50 mm thick complete bed of coarse sand, filling the joints with fine sand etc. all comlete as per the direction of Engineerin-Charge.(Old CC paver blocks shall be supplied by the department free of cost). |
| 26 | Providing and laying 60mm thick factory made cement concrete interlocking paver block kof M-30 grade made by block making machine with strong vibratory compaction of approved size, design & shape, laid in required colour and pattern over and including 50mm thick compacted bed of coarse sand, filling the joints with line sand etc. all complete as per the direction of E/I (AOR) Please Enable Macros to View BoQ information |