| 1 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel / PVC conduit as required. |
| 2 | 3 x 2.5 sq.mm |
| 3 | 3 x 4 sq.mm |
| 4 | 3 x 6 sq.mm |
| 5 | Supplying and fixing following size/modules GI box along with modular base and cover plate for modular switches in recess etc as reqd. |
| 6 | 6 Module (200mmX75mm) |
| 7 | 12 Module (200mmX150mm) |
| 8 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. |
| 9 | 5/6 amps switch |
| 10 | 3 pin 5/6 amps socket outlet |
| 11 | 15 /16 amps switch |
| 12 | 6 pin 15/16 amp socket outlet |
| 13 | Supplying and fixing suitable size G.I. box with modular plate and cover in front or in recess including providing and fixing 25A modular socket outlet and 25A modular SP MCB \\"C\\" curve including connections, painting etc. as required. |
| 14 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed heavy class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 15 | Group C |
| 16 | Rewiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable and 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable as earth wire in existing surface/ recessed steel /PVC conduit including dismantling as required. |
| 17 | Group C |
| 18 | Supplying and fixing of Medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 19 | 25 mm dia |
| 20 | Supplying and fixing 2 module stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as reqd. |
| 21 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required 4 X 16 6sq. mm + 2 X 6 sq. mm earth wire |
| 22 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CM/M/W) minimum 6.00, Air delivery minimum 210 Cum/Min, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. |
| 23 | Supply and fixing of suitable size G.I. box with modular plate and cover on front or surface in recess including providing and fixing 6 pin 5/6 & 15/16A modular socket outlet and 15/16A modular switch, connection etc.as required. |
| 24 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 25 | 12 way (4 + 36), Double door |
| 26 | Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of single pole MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 27 | Single pole |
| 28 | Supplying and fixing following rating, four pole, 415 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 100 amps |
| 29 | Supply, Installation, testing and commissioning of pre wired 2'x2' recess mounted 36 watts LED fitting square shape, Commercial grade with luminaire with diffuser complete with all accessories i/c connection with 1.5 sqmm FRLS PVC copper conductor Cable with mounting 4 nos clutch wire /G.I. chain for mounting from true ceiling etc. as required. Make Philips, Model No. - FullGlow G6 Cat No. RC380B LED36S-6500 G6 L60W60 PSU OD S1 or equivalent model of Thorn/Trilux |
| 30 | Supply, Installation, testing and commissioning of pre-wired, double box type fitting with two no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 2xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 31 | Supply, Installation, testing and commissioning of pre-wired, single box fitting with one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm complete i/c all accessories etc. directly on ceiling/wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor cable and earthing etc. as required. fitting equivalent to Philips Make, Cat No. TMC 502 1xT-LED 22W, Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 32 | Supply, Installation, testing and commissioning of one no. LED tube of frosted cover design, 18 Watt, 2100 lm, 50000 burning hours, size 1200 mm in existing single box or double box fittings complete as required. Tube equivalent to Philips Make, Cat No. Mas LEDTube 1200mm 18W 865 T8I-2100lm |
| 33 | S/F snap-in DLP trunking of 105 mm X 50 mm with suitable cover on the existing wall/ surface i/c having all the accessories such as flat angle, end caps, internal/ external angle etc. as required at site. |
| 34 | Supply, Installation,testing and comissioning of 12 inch heavy duty, AC, Single Phase 230 Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connection etc. as required |
| 35 | Supply, Installation,testing and comissioning of 15 inch heavy duty, AC, Single Phase 230 Volt, 50 Hz, 1350 RPM, steel body exhaust fan in the existing opening, including, making good the damage, cable connection etc. as required |
| 36 | Dismantling of ceiling fan/exhaust fan/Light fittings etc. including disconnection of wires/cable and submission of same in department store etc. complete as required. |
| 37 | Servicing of power distribution cubicál panel/Feeder pillar bavng MCCB at incoming and MCCB/MCB at outgoing which includes, checking of power circuit, replacement of burnt/broken thimble upto síze 2.5 sqmm, busbar tightening, internal connection/termination removing of rust from inner and outer surface, removing the carbon deposit from conductor, cleaning with the help of werlCloths, packing of holes with suitable sealent etc. complete as reguired. This item exclude replacement of any spare |Part/accessories/switchgear, painting of panel and same shall be paid seperately. |
| 38 | Panel size upto 2000(W) X 2400(H) but not below the 1500(W) X 1500(H). Dimensions are in mm. |
| 39 | Panel size upto 1500(w) X 1500(H) but not below the 1000(W) X 1000(H). Dimensions are in mm. |
| 40 | Panel size upto 1000(W) X 1000(H) but not below the 500(W) X 500(H). Dimensions are in mm. |
| 41 | Supplying and fixing of 40A/50A/63A, 10 KA rating, double pole, 415 V, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make-Hager, Cat.No-NCN240N/NCN250N/NCN263N or equivalent model of Legrand/ABB. Please Enable Macros to View BoQ information |