| 1 | WOOD AND P. V. C. WORK |
| 2 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately). |
| 3 | First quality irul wood |
| 4 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows, fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note: Butt hinges and necessary screws shall be paid separately) |
| 5 | First quality irul wood |
| 6 | 35 mm thick shutters |
| 7 | Providing and fixing panelling or panelling and glazing in panelled or panelled and glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured). Panelling for panelled or panelled and glazed shutters 25 mm to 40 mm thick. |
| 8 | Float glass panes |
| 9 | 5.0 mm thick glass panes (weight not less than 12.50 kg/sqm). |
| 10 | Providing and fixing nickel plated M.S. pipe curtain rods with nickel plated brackets : |
| 11 | 25 mm dia (heavy type) |
| 12 | Providing 40x5 mm flat iron hold fast 400 mm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embedding in cement concrete block 300x100x150 mm 1:3:6 mix (1 cement: 3 coarse sand : 6 graded stone aggregate 20 mm nominal size). |
| 13 | Providing and fixing IS : 12817 marked stainless steel butt hinges with stainless steel screws etc. complete : |
| 14 | 125x64x1.90 mm |
| 15 | Providing and fixing special quality chromium plated brass cupboard locks with six levers of approved quality including necessary screws etc. complete. |
| 16 | Size 50 mm |
| 17 | Providing and fixing bright /matt finished Stainless Steel handles of approved quality & make with necessary screws etc all complete. |
| 18 | 100mm |
| 19 | Providing and fixing bright finished stainless steel tower bolts (barrel type) with necessary screws etc. complete : |
| 20 | 150x10 mm |
| 21 | Providing and fixing bright finished Stainless Steel Aldrop with necessary screws etc. complete : |
| 22 | 250x16x5 mm |
| 23 | STEEL WORK |
| 24 | Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required. |
| 25 | In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works |
| 26 | FINISHING |
| 27 | 12 mm cement plaster of mix: |
| 28 | 1:4(1 cement: 4 fine sand) |
| 29 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade : |
| 30 | Two or more coats on new work |
| 31 | Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 32 | Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre of approved brand and manufacture, including applying additional coats wherever required to achieve even shade and colour. |
| 33 | Two coats |
| 34 | Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content. |
| 35 | With ready mixed pink or grey primer on wood work (hard and soft wood) having VOC content less than 50 grams/ litre |
| 36 | With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre |
| 37 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 38 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: |
| 39 | One or more coats on old work |
| 40 | Finishing walls with water proofing cement paint of required shade: |
| 41 | Old work (one or more coats @ 2.20 kg/10 sqm) complete. |
| 42 | Finishing walls with Acrylic Smooth exterior paint of required shade: |
| 43 | Old work (Two or more coat applied @ 1.67 Itr/ 10 sqm) on existing cement paint surface |
| 44 | Finishing roofing tiles with two or more coats of water-based high performance tile guard (Apex tile guard or equivalent) of required shade, applied as per manufacturer specifications |
| 45 | REPAIRS TO BUILDING |
| 46 | Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge. |
| 47 | Dismantling and Demolishing |
| 48 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking anywhere in the campus |
| 49 | Of area 3 sq. metres and below |
| 50 | Taking out doors, windows and clerestory window shutters (steel or wood) including stacking anywhere in the campus |
| 51 | Of area 3 sq. metres and below |
| 52 | ALUMINIUM WORK |
| 53 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / panelling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : |
| 54 | For fixed portion |
| 55 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 56 | For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) |
| 57 | Powder coated aluminium (minimum thickness of powder coating 50 micron) |
| 58 | Providing and fixing 4mm thick Aluminium Partition Panels, in panelling fixed in aluminum door/window shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge. |
| 59 | 4 mm thick aluminium partion panels |
| 60 | WATER PROOFING |
| 61 | Providing and laying water proofing treatment over the concrete surface by applying cement based two component polymer modified water proofing slurry coating (SIKA Topseal 109 or equivalent) after cleaning the surface free from scale, rust, grease, oil etc. preparing the surface to be true and flat and saturated mixing the liquid (A) and powder (B) components in the required ratio, applying in required number of coats with a suitable interval for hardening in between and finally finished by rubbing down with a soft, dry sponge including protecting the applied surface from direct sunlight and strong wind and curing by gunny bags or polythene sheeting upto 5 days etc. complete as per manufacturer recommendations. |
| 62 | NEW TECHNOLOGIES AND MATERIALS |
| 63 | Providing and fixing 18 mm thick ferrocement boards with cement mortar 1:3 with coarse sand and reinforced welded mesh(20 Gauge) , chicken mesh (10Kg) in required thickness for bedroom, kitchen cupboards including cost and conveyance of all materials,labour charges,etc complete, as per direction of Engineer-in-charge. Please Enable Macros to View BoQ information |