| 1 | Demolition of Brick work or stone / boulder masonry built in cement mortar including all quoins, arches, pillars etc but excluding ashlars facings dressed stone work and forecast concrete articles, complete all as specified and directed. |
| 2 | Demolition of Cement Concrete (unreinforced) in ground floors and pavings not exceeding 15.00 cm thickness (below or above ground level) complete all as specified and directed. |
| 3 | Excavating in trenches, not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation etc or not exceeding 10 Sqm on plan and not exceeding 1.5 mtr in depth for shafts, cesspits, manholes, pier holes etc and getting out in soft/loose soil complete all as specified and directed. |
| 4 | M&L for PCC 1:4:8 type D-2 using 40mm graded stone aggregate in foundations, filling and mass concrete including sub base of floors complete all as specified and directed. |
| 5 | M&L for brickwork with Sub Class 'B' Bricks, straight or curved on plan exc 6 mtr mean radius built in CM 1:6, complete all as specified and directed. |
| 6 | Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm each complete all as specified and directed. |
| 7 | Removing excavated soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed. |
| 8 | Extra for forming fair finished channel 45 cm inner girth in cement concrete using extra cement including moulds mitred stopped ends etc complete all as specified and directed. |
| 9 | M&L for Cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate in surface channels and drains complete all as specified and directed. |
| 10 | Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to facilitate demolition) complete all as specified and directed. |
| 11 | Pre-cast Cement Concrete type B-1 (1:2:4) (using 20mm graded aggregate) as in drain cover slabs set in cement mortar 1:6 including necessary formwork complete all as specified and directed. |
| 12 | S&F Mild Steel round bars 10mm dia and over, cut to length, bent to shape required including ranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips Fe-410-W (Gde E-250) Part- I quality-A or Fe 290 (Gde -E-165) complete all as specified and directed. |
| 13 | M&L for 15mm thick rendering in CM 1:4 on fair faces of brick work surfaces finished even and fair without using extra cement complete all as specified and directed. |
| 14 | M&L for PCC 1:2:4 type B-1 using 20mm graded stone aggregate as in coping, benching, bed block, cills like including weathering and slightly rounded etc including form work complete all as specified and directed. |
| 15 | S&F Unplasticized PVC pipes of 110mm dia (cut in suitable length) pressure rating 10 Kg / Sqcm laid in trenches complete all as specified and directed. |
| 16 | Schedule of Credit (MINUS) Rs. 65,500.00 B/F from Serial Page No. ____ [Note : Details of items for schedule of credit is given on Srl Page No. _____] This amount shall be automatically deducted to arrive at tendered sum Please Enable Macros to View BoQ information |