| 1 | Item Rate BoQ BoQ_Ver4.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority:GE (AF) HASIMARA Name of Work : REPAIR / MAINT OF GEYSER AND CONNECTED WORKS IN OMQ, RS, KV, ARJAN, TECH, MES & BASRA AREA AND REPAIR / MAINT OF COOLING APPLIANCES AND CONNECTED WORK IN TECHNICAL, 10 AFH & OFFICE COMPLEX IN LIVING-IN AREA AT AF STN HASIMARA Contract No: GE/HAS/ /2026-27 Name of the Bidder/ Bidding Firm / Company : PRICE SCHEDULE 'A' (BoQ)(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Sl.No. Description of Item Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT With Taxes TOTAL AMOUNT In Words |
| 2 | Comprehensive repair/maintenance of storage type electric heater (geyser) vertical/horizontal type of capacity upto 25/50 ltrs comprising of the following works, complete all as specified and directed :-(a) Inspection, taking down or dismantling, de-scaling, brushing and thoroughly cleaning the storage tank upto the entire satisfection of Engr-in-Charge.(b) Checking of all stop cock, pressure release valve, fusible plug etc to ensure free functioning of the parts including Supply and replacement of washer/gasket, nuts etc as required.(c) Inspect overflaw and vent pipes and remove blockages (if any).(d) Checking and rectify earth continuity of the electrical circuits of the geyser and power points.(e) Check, maintain and re-fixing thermostat and re-adjust.(f) Visual examination of of fusible plugs for its serviceability.(g) De-scaling the immersion type heating element and siphon assembly with diluted hydrochloride acid or cear pedette solution.(h) Checking of indicator lamp for its serviceability.(j) Re-assembling the geyser, re-installed and testing.Note: (i) Spare parts/components of geysers shall be measured and paid seperately as \\"supply only\\" under respective items. (ii) Any minor parts required for smooth functioning of the geyser shall be provided by the contractor without any extra cost to the Govt.) |
| 3 | Supply only heating elements as per site requirement of capacity 1.5 KW, 230 volts ISI marked, complete all as specified and directed. |
| 4 | Supply only heating elements as per site requirement of capacity 2 KW, 230 volts ISI marked, complete all as specified and directed |
| 5 | Supply only aperature plate suitable for 25 Ltr capacity, complete all as specified and directed |
| 6 | Supply only high pressure safety valve, complete all as specified and directed |
| 7 | Supply only geyser NRV (Non Return Valve) 1/2 inch 0.8 MPa pressure, complete all as specified and directed |
| 8 | Supply only hot and cold 'SS-304' grade stainless steel re- enforced flexible connection pipe 450mm long, ISI marked, complete all as specified and directed |
| 9 | Supply only thermostate adjustable type 11/20 Amp 240 Volts, ISI Marked, complete all as specified and directed |
| 10 | Supply only thermostate adjustable type 7/15 Amp 240 Volts, ISI Marked, complete all as specified and directed |
| 11 | Taking down 15mm bore steel water tubing and connection from wall /ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed. |
| 12 | Taking down 20mm bore steel water tubing and connection from wall/ceiling surfaces including cleaning for re-fixing or removing from site of work, complete all as specified and directed. |
| 13 | Supply, laying & connecting of 15mm bore GI tubing, medium grade, with all necessary fittings such as bends, elbows, tees, shorts pieces, disminishing pieces, caps & plugs, fixed to wall and ceiling or laid in floors, complete all as specified and directed. |
| 14 | Supply, laying & connecting of 20mm bore GI tubing, medium grade, with all necessary fittings such as bends, elbows, tees, shorts pieces, disminishing pieces, caps & plugs, fixed to wall and ceiling or laid in floors, complete all as specified and directed. |
| 15 | S&F in repair 15mm bore bib tap cast alloy screwed down with crutches or butterfly handle, screw down for iron pipe or for brass ferrule, complete all as specified and directed |
| 16 | S&F in repair power unit suitable for load max up to 3.5 KW including sockets 32 Amps, and six module box for mounting of power unit and power socket, complete as specified and directed. |
| 17 | S&F modular cover plate with frame including modular surface mounting plastic box of size 3' x 3', 2 module, white, completes all as specified and directed. |
| 18 | S&F in repair plug top, 15 Amps, complete all as specified and directed. |
| 19 | S&F in repair switch, modular type, single pole, one way, 15/16 Amps, one module, complete all as specified and directed. |
| 20 | S&F in repair socket outlet modular type, multipurpose having provision for 3 pin, 15/16 Amp and 3 pin 5/6 Amp, two module, complete all as specified and directed. |
| 21 | S&F in repair MCB Single Pole (SP) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘B’ series, as per IS/IEC 60898-1, fixed in proper position, complete all asspecified and directed. |
| 22 | S&F in repair MCB Single Pole & Neutral (SPN) of capacity 6 to 32 Amps, 240 Volts, breaking capacity 10 KA, ‘C’ series, as per IS/IEC 60898-1, fixed in proper position, complete all as specified and directed. |
| 23 | Taking down and servicing of split type AC of 1.5 to 2 TR capacity, any type/size/make/model cleaning and washing of condenser assembly with chemical and high pressure jet pump, checking and retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring and refixing properly after servicing, complete all as specified and directed.Note : Spare parts & gas charging shall be measured & paid seperately under respective items. |
| 24 | Taking down and servicing of cassete type AC of 3 to 5 TR capacity, any type/size/make/model cleaning and washing of condenser assembly with chemical and high pressure jet pump, checking and retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring and refixing properly after servicing, complete all as specified and directed.Note : Spare parts & gas charging shall be measured & paid seperately under respective items. |
| 25 | Taking down and servicing of VRV/VRF and tower type AC of 7.5 TR capacity, any type/size/make/model cleaning and washing of condenser assembly with chemical and high pressure jet pump, checking and retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring and refixing properly after servicing, complete all as specified and directed.Note : Spare parts & gas charging shall be measured & paid seperately under respective items. |
| 26 | Taking down and servicing of window type AC of 1.5 to 2 TR capacity, any type/size/make/model cleaning and washing of condenser assembly with chemical and high pressure jet pump, checking and retightening of all electrical connections, replacement of nuts, bolts, screws, washers, internal wiring and refixing properly after servicing, complete all as specified and directed.Note : Spare parts & gas charging shall be measured & paid seperately under respective items. |
| 27 | Taking down and servicing of defective water cooler of capacity 40 to 80 Ltr of any type/make/model and cleaning, washing condenser assembly with high pressure jet pump and cleaning, rubbing and washing of storage water tank, draining of dirty water silt, checking, retightening, all electrical connections, replacement of nuts, bolts, screws, washers, drainpipe, internal wiring and reassembling properly after repair, complete all as specified and directed.Note : Spare parts & gas charging shall be measured & paid seperately under respective items. |
| 28 | Taking down and servicing of refrigerators of 165 Ltr to 400 Ltr capacity, any type/size/make/model including replacement of unserviceable parts and cleaning, washing, condenser assembly, retighening all electrical connections, replacement of nuts, bolts, screw, washers, internal wiring, fixing properly bracket housing of capacitors and reassembling properly after repair, complete all as specified and directed.Note : Spare parts & gas charging shall be measured & paid seperately under respective items. |
| 29 | M&L for testing leakage of gas and replacement of damaged portion of copper pipe of any dia upto 30cm length, brazing by oxyaccetelene gas welding and good quality copper brazing rods or soldering damaged portion, flaring copper pipe, replacement of flare nut and pouring the nitrogen gas flushing to check the leakage in copper pipe lines, recharging suitable gas fully after complete removal of nitrogen gas on satisfactorily completion of leak test, reassembling and testing cooling of whole refrigerator of any capacity/type and make, complete all as specified and directed. |
| 30 | All as per item No 28.00 here-in-before but for window type AC with R-22 gas of any capacity/make/type/model, complete all as specified and directed. |
| 31 | All as per item No 28.00 here-in-before but for water cooler with R-134 gas of any capacity/make/type/model, complete all as specified and directed. |
| 32 | All as per item No 28.00 here-in-before but for split type AC with R-22/134/410A gas of any capacity/make/type/mode/model, complete all as specified and directed. |
| 33 | Supply and fixing power unit with 20 Amps starter including 4 module plate, 20A plug and socket, PVC box for mounting of power unit suitable for 20 Amps power unit and connection of electric supply and testing, complete all as specified and directed. |
| 34 | M&L for submain wiring concealed, with two single core PVC insulated unsheathed, multistranded flexible copper conductor cable 4 Sqmm, 1100Volts grade, FRLSH type, drawn in and including heavy duty rigid PVC conduit (ISI marked) not less than 20mm dia with fixing accessories including 4 Sqmm 1100 Volts grade, FRLSH type, PVC insulated unsheathed multistranded flexible copper conductor cable as continuous earth wire and connecting to common earth dolly including taking down old sub-main wiring of any size, complete all as specified and directed.Note:- Three runs of cable and one run PVC conduit and its accessories shall be measured as one length of sub main. |
| 35 | Dismantling and taking down from existing position window type AC 1.5/2 ton capacity and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position and new position etc, complete all as specified and directed. |
| 36 | Dismantling and taking down from existing position split type AC of capacity 1.5/2 ton and refixing the same in new position including necessary cutting opening, fixing, connecting, testing and making good disturbed surface of old position and new position etc, complete all as specified and directed.Note : Necessary gas charging, mounting stand, drain pipe and copper tube shall be paid and measured seperately. |
| 37 | Dismantling and taking down from existing position split type AC, 1.5/2 ton capacity, including transporting and repairing in workshap outside the Stn permises and return back to AGE E/M store yard, complete all as specified and directed. |
| 38 | All as per item No 36.00 here-in-before but window type AC of capacity 1.5/2 ton, complete all as specified and directed. |
| 39 | Taking down and dismantling the unserviceable blower motor from 1.5/2 TR window/split AC of any type including opening all outer case and rewinding,heat varnishing the blower motor with super enamel copper wire of suitable gauge by taking out burnt winding and cleaning the iron core, complete all as specified and directed. |
| 40 | All as per item No 38.00 here-in-before but blower motor of water cooler of capacity 40 to 80 Ltr, complete all as specified and directed. |
| 41 | S & F in repair potential relay box suitable for refrigerator of any make/model/capacity, complete all as specified and directed. |
| 42 | S & F in repair auto defrost thermostate switch suitable for refrigerator, complete all as specified and directed. |
| 43 | S & F in repair pigmay bulb (thick/thin thread) 230 Volt suitable for refrigerator, complete all as specified and directed. |
| 44 | S & F in repair harmetic sealed type compressor suitable for 180/230/310 Ltr refrigerator, complete all as specified and directed. |
| 45 | S & F in repair freezer fan motor single phase 230 Volt, 50 Hz suitable for refrigerator of capacity 280 to 310 Ltr, complete all as specified and directed. |
| 46 | S & F in replacement of door gasket suitable for deep freezer 300/320 ltr & 310/286/165 lty capacity refrigator, complete all as specified and directed. |
| 47 | S & F in replacement of freezer including necessary capilary suitable for 165 lty capacity refrigator, complete all as specified and directed. |
| 48 | S & F in repair cooling coil assy suitable for 180 to 310 Ltr capacity refrigerator, complete all as specified and directed. |
| 49 | S & F in repair defrost heater suitable for 180 to 310 Ltr refrigerator, complete all as specified and directed. |
| 50 | S & F in repair timer switch suitable for 180 to 310 Ltr refrigerator, complete all as specified and directed. |
| 51 | S & F in repair bimetal unit assy suitable for 180 to 310 Ltr refrigerator, complete all as specified and directed. |
| 52 | S & F in repair overload protector relay as per sample for window type AC of any make/model 1.5 -2.0 TR capacity, complete all as specified and directed. |
| 53 | S & F fan motor, single phase 230 Volt, 50 Hz suitable for window AC, complete all as specified and directed. |
| 54 | S & F in repair strainer of capillary tube suitable for window AC, complete all as specified and directed. |
| 55 | S & F in repair harmetic sealed type compressor suitable for window AC of capacity 1.5 TR, complete all as specified and directed. |
| 56 | S & F in repair rotary compressor of 1.5 ton capacity suitable for split type AC of any make/model 1.5 TR capacity, complete all as specified and directed. |
| 57 | S & F in repair rotary compressor of 2.0 ton capacity suitable for split type AC of any make/model 2.0 TR capacity, complete all as specified and directed. |
| 58 | S & F in repair inverter type compressor of 2.0 ton capacity suitable for split type AC of any make/model 2.0 TR capacity, complete all as specified and directed. |
| 59 | S & F in repair inverter type compressor of 1.5 ton capacity suitable for split type AC of any make/model 1.5 TR capacity, complete all as specified and directed. |
| 60 | S & F in repair power contactor suitable for 1.5/2 ton capacity split / window AC, complete all as specified and directed. |
| 61 | S & F in repair outdoor fan motor, single phase 230 Volt, 50 Hz suitable for split AC 1.5/2.0 TR capacity, complete all as specified and directed. |
| 62 | S & F in repair indoor DC fan motor, rating output 50 watt, DC 310 Volt, RPM minimum 720/r/min suitable for inverter split AC, cassete AC upto 3.7 TR capacity, complete all as specified and directed. |
| 63 | S & F in repair condenser coil set suitable for windoe type AC of 1.5 ton capacity, complete all as specified and directed. |
| 64 | S & F of swing motor fot split AC fited in internal unit capacity 3 to 5 watt, 5 to 8 RPM suitable for 1.5/2.0 TR capacity with wiring kit and thimble, complete all as specified and directed. |
| 65 | S & F in replacement of air filter for split type AC of 1.5/2.0 ton capacity, as per sample, complete all as specified and directed. |
| 66 | S & F in replacement of front grill of window type AC of 1.5/ 2.0 ton capacity, as per model of the AC, complete all as specified and directed. |
| 67 | S & F new PVC sheathed copper cable 3 core of size 4 Sqmm including reconnecting and testing including taking out old unserviceable copper cable by disconnecting all the electrical coneections, complete all as specified and directed. |
| 68 | S & F in repair PCB of non inverter split type AC of 1.5/2.0 ton capacity with complete accessories of any make/capacity, complete all as specified and directed. |
| 69 | S & F in repair multi terminal capacitor (50 + 6/50 + 4mfd) suitable for split AC (stating, running and fan combined), complete all as specified and directed. |
| 70 | S & F in repair 15mm dia PVC drain pipe, medium grade, for split AC as per existing, complete all as specified and directed. |
| 71 | S & F in repair PCB for cassette type AC suitable for indoor/outdoor unit, model and make as per existing, complete all as specified and directed. |
| 72 | S & F in repair PCB for outdoor unit of inverter split type AC of 1.5/2.0 ton capacity, model and make as per existing, complete all as specified and directed. |
| 73 | S & F in repair PCB for indoor unit of inverter split type AC of 1.5/2.0 ton capacity, model and make as per existing, complete all as specified and directed. |
| 74 | Supply and filling of refrigerant gas R-22 in factory sealed cylinder, complete all as specified and directed. |
| 75 | Supply and filling of refrigerant gas R-134A factory sealed cylinder, complete all as specified and directed. |
| 76 | Supply and filling of refrigerant gas R-32 factory sealed cylinder, complete all as specified and directed. |
| 77 | Supply and filling of refrigerant gas R-410A factory sealed cylinder, complete all as specified and directed. |
| 78 | S & F in repair blower motor, Indoor unit, single phase 230 V suitable for window type AC 1.5/2 ton, complete all as specified and directed. |
| 79 | S & F in repair in repair copper tube 1/4\\", complete all as specified and directed. |
| 80 | S & F in repair in repair copper tube 1/2\\", complete all as specified and directed. |
| 81 | S & F in repair in repair insulation tube 1/4\\", complete all as specified and directed. |
| 82 | S & F in repair in repair insulation tube 1/2\\", complete all as specified and directed. |
| 83 | S & F in repair in repair copper tube 5/8\\", complete all as specified and directed. |
| 84 | S & F in repair in repair insulation tube 5/8\\", complete all as specified and directed. |
| 85 | S & F in repair remote control suitable for 1.5/2 ton split/window type AC as per existing make, complete all as specified and directed. |
| 86 | S & F in repair overload protector relay suitable for 40 to 80 Ltr water coolers of any make/model, complete all as specified and directed. |
| 87 | S & F in repair potential relay box suitable for 40 to 80 Ltr water cooler, complete all as specified and directed. |
| 88 | S & F in repair thermostate switch suitable for 40 to 80 Ltr water cooler, complete all as specified and directed. |
| 89 | S & F in repair 15mm dia stop cock, cast copper alloy chromium plated screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for union suitable for water cooler of any capacity, complete all as specified and directed. |
| 90 | S & Fin repair fan motor, single, phase 230 volts 50 Hz suitable for water cooler of 40/80 ltr cooling capacity, complete all as specified and directed. |
| 91 | S & F in repair condenser unit assembly suitable for 40/80 ltr capacity water cooler, complete all as specified and directed. |
| 92 | S & F in repair drain pipe PVC medium grade 25mm dia including GI clamp complete for water cooler, complete all as specified and directed. |
| 93 | S & F in repair 15mm dia PVC cold water pipe with both ends brass/chromium coated socket, suitable for water cooler, complete all as specified and directed. |
| 94 | S & F in repair harmetic sealed compressor suitable for cooling capacity 40/80Ltr water cooler, complete all as specified and directed. |
| 95 | S & F in repair condensor unit assembly suitable for split AC 1.5 /2 ton capacity, complete all as specified and directed. |
| 96 | S & F in repair outdoor blower fan blade suitable for split AC 1.5/2 ton, complete all as specified and directed. |
| 97 | Repair/maintenance of voltage stabilizer of capacity upto 5 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+ 1%) and automatic change over circuit etc, complete all as specified and directed. Note : Minor defective parts shall be replaced by the contractor and the rate of the same shall deemed to be included in quoted rate. |
| 98 | S&F voltage stabilizer for automatic operation, single phase naturally air cooled indoor type & designed for input variation between 90 V to 300 V with ooutput voltage stabilizied at 230 V with accuaracy of + 2.5% can operate upto 12 Amp and above capacity 15 Amp of capacity upto 2 KVA including replacement of driving transformer input 160 to 280 Volts and output 240 volts (+1%) and automatic change over circuit etc, complete all as specified and directed. |
| 99 | S & F in repair split AC outdoor mounting stand as per existing, complete all as specified and directed. |
| 100 | S & F in repair starting capacitor 50-100 Mfd, complete all as specified and directed. |
| 101 | Note for SL item No - 22.00 to 99.00 : - Contractor has to arrange the Comprehensive maintenance of day to day maintenance of cooling appaliances at techical area of AF Stn Hasimara consisting of following and maintaining the records like details of complaints , completion of Job card/complaint slip on standard format and inluding completion reports of Job card from users/department and including required tools and plants , minor electrical sparers like small piece of wire, insulaton tape, screws etc required to rectifify the complaints and attending complaints in various technical Accn/LABs, etc including and replacing the spare parts in summer/cooling appliances, spares required shall be measured and paid seperately under respective items in BOQ complete as per the job card, complete all as specified and directed. Note (i): Contractor shall employ minmum one skilled technician with helper for 08 Hrs (one shift) per day (from 09.00 Hrs to 17: 00 Hrs) for 6 days in a week during contract period except on sundays and public holidays approved by GE (AF) Hasimara irrespective of number of Job cards issued to contractor. (ii) The person employed by the contractor has to check the fittings/fixtures, equipments and wiring as per the complaints/Job card, spares for replacement shall be measured and paid as supply only under respective items and no extra payment shall be done for checking/inspection of fittings . |
| 102 | Note: An amount of Rs. 65,594.00 on account of Credit Schedule for schedule 'A' part - II shall be deducted from the total amount of BOQ to arrive at the contract sum. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |