| 1 | Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m deep along the existing sewage line carefully for placing taking out and getting out in soft/loose of soil complete all as specified and directed. |
| 2 | Excavation in trenches exceeding 1.50 m deep and not exceeding 3.00 m deep along the existing sewage line carefully for placing taking out and getting out in soft/loose of soil complete all as specified and directed. |
| 3 | Returning and filling soil in layers not exceeding 25cm thick each layer including spreading, leveling, watering and well ramming all as speicified and directed. |
| 4 | Removal of surplus excavated material to a distance not exc 50 m and deposited where directed at a level not exc 1.50 m above starting point all as specified and directed. |
| 5 | Demolition and breaking up 200mm dia drain pipes (salt glazed ware, AC or reinforced concrete) set in cement mortar. |
| 6 | M & L salt glazed stone ware drain pipes of internal dia 200 mm bore grade 'A' laid in trenches and jointed in cement mortar complete all as specified and as directed. |
| 7 | M&L reinforced cement concrete pipes 200 mm bore, class NP2, laid and jointed in position with collars complete all as specified and as directed. |
| 8 | M&L for concrete bed to drain pipe including packing under and haunching against the sides of drain pipe after they are laid and tested in PCC 1:3:6 type C-2 for 200mm dia all as specified and directed |
| 9 | Punchuring and necessary repairs to existing SGSW pipe of 200mm dia for clearing blockages and sealing with piece of pipe, covering the entire area with cement concrete PCC 1:3:6 type C1 to avoid unhygenic condition and concreting around the pipe including necessary excavation complete all as specified.Note for item No 12,13 : Rate quoted deemed to include necessary excavation and earth work in any type of soil, returning filling complete all as specified and directed. |
| 10 | Cutting into existing manholes for connecting new drains pipe of 200 mm dia, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 using 20 mm graded stone aggregate, surfaces smooth finished and reforming benching as required complete all as specified and as directed. |
| 11 | M&L Cleaning/ clearing of sewage line (including manholes) 150 mm to 300 mm dia main line from 1st manhole onwards bore of any description, underground at any depth, removing any type of blockage including desludging, descaling & decoking of drain as well as manholes with combined high pressure water jetting cum suction (vacuum) type machine mounted on LCV/HCV /LMV/HMV and having facilities of high pressure vacuum and provn of hydraulic through high pressure thermo plastic fiber based water jetting hose and conical round shape nozzle pipe and flushing after cleaning including removing the same out side MD land and deposit where the place marked by the local municipality, complete all as directed. |
| 12 | Cleaning of manholes any size and not exc 1.5m depth including lifting, removing sludge, water with using mechanical instrument and cleaning with water including cutting grass, vegetation and bushes to a width of 60cm all alround manholes complete all as specified and directed. |
| 13 | Cleaning of manholes any size and exc 1.5m depth including lifting, removing sludge, water and cleaning with water using mechanical instrument including cutting grass, vegetation and bushes to a width of 60cm all alround manholes complete all as specified and directed.Note : the sludge obtained while cleaning shall be removed from the site to outside of MOD land. The rates quoted for items shall include the above provns also. |
| 14 | Removing plant/Uprooting of vegetation growth including roots on wall/roof/parapet near pipes etc and applying acid treatment after removing roots for preventing regrowth and making good disturbed surfaces/area in superficial area exc 150sq.cm but n.exc 400 sq.cm and averaging depth not exceeding 10 cm by using PCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) or 10mm thick plastering in cement mortar 1:3 as required and finishing the surfaces to match with the existing surface complete all as specified and directed. |
| 15 | M&L Repair to leakage/seepage from the Nahani trap/ floor trap of kitchen/ bathroom/ washbasin of the upper Qtr, in any position at any height, complete including change of floor trap, PVC horinzontal pipe embeded in floor in bathroom or kitchen making good to the damaged portion of flooring, laying and matching of tiles in the existing flooring, complete all as specified and directed |
| 16 | M&L Repair to leakage/seepage from the wall/ door bend /door tee/ 'Y' junction/ 'T' Junction of soil pipe / waste pipe/ vent pipe of kitchen/ bathroom/WC of the upper Qtr or at the ground floor Qtr including change of any damaged soil waste pipes or fittings of any shape, specification and size, making good to the damaged portion of wall with brick work in cement mortar 1:6 or cement concrete 1:2:4 and plastering to wall in CM 1:4 and finished the surfaces matching to existing wall to avoid the leakage/ seepage at the site of work complete all as specified and directed. |
| 17 | Note for item No 15 & 16 :- (a) Find out main cause of leakage and take necessary steps to resolve / rectify.(b) Replace existing tiles in case leakage through NT/FT.(c) The rate also include provision of new NT/FT.(d) The unit rate is also deemed to be included for reqd bonding chemicals to arrest the leakage/seepage as directed by the manufacturer's specification. Make : M/s Sika Chemical, M/s Pidilite, M/s Dr Fixit |
| 18 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches bore of pipe 75 mm with PVC clamps and saddles including taking down old existing pipes and dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed |
| 19 | S & F PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls/trenches bore of pipe 110 mm with PVC clamps and saddles including taking down old existing pipes and dismantling of cast iron/RCC/PVC drain pipes jointed in cement mortar and taking out from trenches or walls of any bore including fittings complete all as specified and as directed |
| 20 | S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 75 mm complete all as specified and as directed. |
| 21 | S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 110 mm complete all as specified and as directed. |
| 22 | S & F in repairs PVC (SWR) bends of any radius with access door bore of pipe 150 mm complete all as specified and as directed. |
| 23 | S & F in repairs PVC (SWR) junction single (single T) equal or unequal with access door bore of pipe 75 mm complete all as specified and as directed. |
| 24 | S & F in repairs PVC (SWR) junction single (single T) equal or unequal with access door bore of pipe 110 mm complete all as specified and as directed. |
| 25 | S & F in repairs 125/ 110 mm bore PVC (SWR) floor trap plain with grating incl jointing with solvent cement complete all as specified and as directed. |
| 26 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlar facings, dressed stonework and precast concrete articles |
| 27 | M & L walling of random rubble, uncoursed, Bangalore type masonry well bonded bedded solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 all as specified and directed. |
| 28 | Fixing only walling random rubble, uncoursed, Bangalore type masonry (except stone) well bonded bedded solidly hearted built in CM 1:6, extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified, key pointing to random or polygonal rubble, uncoarsed or brought upto courses in CM 1:4 and including removal and refixing, built in cement mortar of any description as specified and directed. (Old stones shall be re-used) |
| 29 | M&L Pre-cast PCC 1:3:6 type C1 (using 20 mm graded stone agg) cement concrete block masonry with solid blocks exc. 10cm in width and set in cement mortar 1:6 built in cement mortar of any description complete all as specified and as directed. |
| 30 | M&L for rendering 15mm thick in cement mortar (1:4) on brick or concrete surfaces of wall and finishing the surface even and smooth without using extra cement complete all specified and directed. |
| 31 | M & L for 75 mm thick PCC type C1, 1:3:6 (20 mm graded stone aggregate) as in plinth protection finishing the surface even and smooth without using extra cement all as speecified and as directed. |
| 32 | Dismantling stone slabs and tiles of any description or thickness in floors, aprons etc laid bedded and pointed in any mortar . |
| 33 | M&L in 300mmx300mmx25mm thick pre-polished cement concrete chequered tile jointed in neat cement slurry and pointed in white or coloured cement to match the floor, complete, all as specified and directed. |
| 34 | M&L for screedbed or bedding layer of mortar 20mm thick in cement mortar 1:6 for laying floor finishes complete all as specified and directed. |
| 35 | Site clearance by Scraping of grass/wild growth/trees cutting n.exc 0.30m girth etc in soft/loose soil by manually/mechanically including removing of rubbish from the site to a distance exc, 250m but n. exc 500m and deposited where directed at a level not exc. 1.5m above the starting point, complete all as specified and as directed |
| 36 | Demolition of old concrete (un reinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 37 | Taking down and refixing precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade over sand cushion with grey cement and no pigment and including side kerb concrete, including removal and refixing all as specified and directed. |
| 38 | M&L for machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60mm thickness, M-35 Grade with grey cement and pigment all as specified and directed. |
| 39 | M&L hard core broken stone of guage n exc 63mm deposited spread and levelled in layers n exc 15 cm thick watered and rammed to a true surface complete all as specified and directed. |
| 40 | Cleaning of blockage from nahani traps of bathroom/kitchen/Urinal/toilet in ground floor and upper floors all types any size, any height by taking out mud/sand incl taking out lid and re-fixing the same complete all as specified and as directed. |
| 41 | Cleaning of blockage from Gully trap to 1st manholes in ground floors, all types any size, any location by taking out mud/sand incl taking out lid and re-fixing the same complete all as specified and as directed. Please Enable Macros to View BoQ information |
| 42 | Cleaning of blockage from Gully trap to 1st manholes in ground floors, all types any size, any location by taking out mud/sand incl taking out lid and re-fixing the same complete all as specified and as directed. Please Enable Macros to View BoQ information |