| 1 | Demolition Cement Concrete (un-reinforced) of any description in Ground Floors, Pavings, etc. not exc. 150mm thickness (above or below Ground Level) and removing debris, etc. to Outside MD/AF Land, complete all as specified and as directed. |
| 2 | Dismantling Stone slabs and tiles of any description or thickness in floors, aprons etc, complete all as specified and as directed. |
| 3 | M&L Cement Concrete 1:4:8 (40mm Graded Stone Aggregate) 100mm thick in Sub-bases, complete all as specified and as directed. |
| 4 | M&L for laying Machine pressed precast concrete interlocking paver block any shape and size confirming to IS 15658-2006 of 60 mm thickness, M-35 Grade with grey cement and pigment complete all as specified and as directed. |
| 5 | M&L sand filling under floors or in foundation incl watering and consolidation complete all as specified and as directed. |
| 6 | Providing and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), including making joints with or without grooves (thickness of joints except at sharp curve shall not to more than 5 mm), including making drainage opening wherever required complete all as specified and as directed. |
| 7 | M&L for Chequered cement concrete tiles 30 cm x 30 cm x 25 mm thick , set , jointed and pointed in neat cement slurry over and including 15 mm thick screed bed or bedding layers in CM 1:6 for laying floor finishes in floors , path / hard standing etc with grey cement and pigment (Coloured Tiles) complete all as specified and directed. |
| 8 | M&L Cement Concrete 1:2:4 (20mm Graded Stone Aggregate) 100mm thick as in flooring, complete all as specified and as directed. |
| 9 | M&L for Forming 12 mm thick expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade ‘B’ for 100m thick slab complete all as specified and as directed |
| 10 | M&L for Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade 'B' complete all as specified and as directed. |
| 11 | Dismantling wrought iron or mild steel work of any description not otherwise provided for. |
| 12 | S&F mild steel Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290 Gde-E-165 complete all as specified and as directed |
| 13 | M&L preparing New or previously untreated Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying Two Coats of Synthetic Enamel Paint (First quality) over a Red Oxide Zinc Chrome Primer, complete all as specified and as directed. |
| 14 | M&L preparing old painted Steel and Iron Surfaces of any description, over 10 Cm width or girth and applying One Coat of Synthetic Enamel Paint (First quality), complete all as specified and as directed. |
| 15 | M&L for prepairing new or previously untreted Surfaces of any description, n.exc 10cm in width or girth when connectedwith other painting or when painted in a different tint, applying two coat of synthetic enamal paint over a coat of red oxide zinc chrome primer complete all as specified and as directed. |
| 16 | Dismantling fencing wire mesh, any type complete all as specified and as directed |
| 17 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion in concrete and making good disturbed ground complete all as specified and as directed. |
| 18 | Excavating in post holes (or similar holes) each n exc 0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25 cm, watering, and removing surplus soil to a distance n exc 50 m and making good surface complete all as specified and as directed |
| 19 | M&L for Cement concrete 1:2:4 type B2 as in foundations, filling and mass concrete complete all as specified and as directed. |
| 20 | S&F mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc. and similar work conforming to Fe-290 Gde E-165 complete all as specified and as directed |
| 21 | S&F mild steel round bars 10mm dia and over, horizontaly woven in chain link fencing including cut to length, bent to shape required, including cranking, bending etc complete all as specified and as directed. |
| 22 | Supply only Chain link MS galvanisd fencing, any size or type complete all as specified and as directed. |
| 23 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire complete all as specified and as directed |
| 24 | S&F Mild steel screw bolts 12mm dia (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, exc 5cm but n exc 10m long complete all as specified and as directed |
| 25 | S&F in repair Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails strain- ing bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete all as specified and as directed. |
| 26 | Dismantling Plain or corrugated steel/ Fibre translucent sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and as directed |
| 27 | S&F pre-painted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick of colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screw complete all as specified and as directed |
| 28 | M&L for preparing of old surfaces of walls and applying one coat of cement based paint complete all as specified and as directed. |
| 29 | Desilting of man hole up to 1.50m depth and stacking the silt at the distance exc 100m but not exc 250m, complete all as specified and directed by Engineer-In-Charge. |
| 30 | All as per item No. 29 here in before but depth of man-hole exceeding 1.50m and not exceeding 2.50m complete all as specified and as directed |
| 31 | Cleaning of WC/EWC and removal of blockage by pumping of waste up to first manhole with steel road/ flexible rod or bamboo or through mechanical sewage cleaning apparatus and finally washing with fresh water complete all as specified and directed. |
| 32 | Cleaning of Nanahi trap and removal of blockage by pumping of waste up to first manhole with steel road/ flexible rod or bamboo or through mechanical sewage cleaning apparatus and finally washing with fresh water complete all as specified and directed. |
| 33 | Cleaning of Gully trap and removal of blockage by pumping of waste up to first manhole with steel road/ flexible rod or bamboo or through mechanical sewage cleaning apparatus and finally washing with fresh water complete all as specified and directed. |
| 34 | Removal of blokage/choke up obstructing the flow of sewage line of stoneware pipe and RCC pipe between two consecutive manholes at any depth by rodding and flushing water in line after rodding to clean the line for 100mm dia pipe complete all as specified and directed. |
| 35 | All as per Item No. 34 here in before but for 150 mm bore pipe complete. |
| 36 | All as per Item No. 34 here in before but for 200 mm bore pipe complete. |
| 37 | Demolition & breaking up Drain Pipe 150mm dia (Salt Glazed Ware, AC or Reinforced Concrete) set in cement Mortar, complete all as specified and directed. |
| 38 | Demolition & breaking up Drain Pipe 200mm dia (Salt Glazed Ware, AC or Reinforced Concrete) set in cement Mortar, complete all as specified and directed. |
| 39 | Excavating in Trenches, not exc. 1.50 Metre wide and not exc. 1.50 Metre in depth; for Foundation, etc. or for Shafts, Wells, Cesspits, Manholes, Pier Holes, etc. not exc. 10 Sqm on Plan and not exc. 1.50 Metre in depth and getting out in Soft/Loose Soil, complete all as specified and as directed. |
| 40 | Returning, filling in approved Soft/Loose Soil including spreading leveling, watering and well ramming in layers not exc. 25 Cm thick, complete all as specified and as directed. |
| 41 | Removing Excavated Materials (Soils) not exc. 50.00 Metre and depositing where directed at a level not exc. 1.50 Metre above the Starting Point including spreading over ground, complete all as specified and as directed. |
| 42 | M&L for Sail-glazed stoneware drain pipes 150 mm dia laid in trenches and jointed complete all as specified and as directed. |
| 43 | M&L for Sail-glazed stoneware drain pipes 200 mm dia laid in trenches and jointed complete all as specified and as directed. |
| 44 | M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) as in Concrete Bed to Drain Pipes of 150mm bore (dia), including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 45 | M&L Cement Concrete 1:3:6 (40mm graded stone aggregate) as in Concrete Bed to Drain Pipes of 200mm bore (dia), including packing under, and haunching against the sides of pipes after they are laid and tested complete all as specified and as directed. |
| 46 | S&F in repairs 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in floors/ trenches complete all as specified and as directed. |
| 47 | S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 48 | S&F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to walls complete all as specified and as directed. |
| 49 | S&F in repairs 110mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors complete all as specified and as directed. |
| 50 | S&F PVC (SWR) bends any radius 75mm dia complete all as specified and as directed. |
| 51 | S&F PVC (SWR) bends any radius 110mm dia complete all as specified and as directed. |
| 52 | S&F PVC (SWR) vent cowl any radius 75mm dia complete all as specified and as directed. |
| 53 | S&F PVC (SWR) vent cowl any radius 110mm dia complete all as specified and as directed. |
| 54 | S&F PVC (SWR) branch piece, single (single Y) equal or unequal 75mm dia complete all as specified and as directed. |
| 55 | S&F PVC (SWR) branch piece, single (single Y) equal or unequal 110mm dia complete all as specified and as directed. |
| 56 | S&F in repairs PVC (SWR) floor trap, plain with grating including jointing with solvent cement 75 mm bore dia of outlet of pipe complete all as specified and as directed. |
| 57 | S&F in repairs PVC (SWR) gully trap 125/110mm setting and jointing with solvent cement and making good of disturbing gound with PCC 1:2:4 complete all as specified and as directed. |
| 58 | Cutting holes in brick walls built in cement mortar for inserting/ taking out holdfasts/ pipes etc and making good dismantled portion in cement mortar 1:3 or cement concrete 1:2:4 type B-1 as required ( depth of embedded portion of holdfasts/ pipes/ lugs exc half brick but n. exc one brick and measured from the face of walls) complete all as specified and as directed. |
| 59 | M&L for PCC 1:3:6, type C2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed. |
| 60 | Demolition of brickwork or stone/ boulder masonry, built in cement mortar complete all as specified and directed. |
| 61 | M&L Brick Work with fly ash bricks, straight or curved on plan exc 6m mean radius, built in in Cement Mortar 1:4, complete all as specified and as directed. |
| 62 | M&L Cement Concrete 1:2:4 (20mm graded stone aggregate) in Benching to Manhole including Forming Channel, laid to shape and Slope Coping, Plates including necessary Formwork and Fair Finished to Exposed Concrete Surfaces and Weathering, Slightly Rounded or Chamfered Angles and Throating, complete all as specified and directed. |
| 63 | Extra for forming fair finished drain or drain channel 30 cm inner girth in cement concrete using extra cement including forms moulds mitred stopped ends etc complete all as specified and as directed. |
| 64 | Add or deduct for each 25 mm girth or part thereof over or under 30cm ditto for item No 63 |
| 65 | M&L for Rendering 15mm thick in Cement Mortar 1:4 (Externally) on Fair Faces of Brick Walls or on Concrete Surfaces, mixing with WPC as per manufacturer's instructions, Plastered Surfaces finished Even and Smooth without using Extra Cement, complete all as specified and as directed.NOTE : WPC will be Measured and Paid separately as ‘Supply only’ under relevant Item. Repairs in patch work & height of walls upto 6.50 Mtr to be carried. |
| 66 | Demolition Cement Concrete (reinforced) of any description (above or below Ground Level) and removing debris, etc. to Outside of MD/AF Land, complete all as specified and directed. |
| 67 | M&L Pre-cast Reinforced Cement Concrete 1:2:4 (20mm graded stone aggregate) in Slabs, Manhole Cover Slabs, etc., set in Cement Mortar 1:4, complete all as specified and directed. Note : Reinforcement will be measured and paid separately under relevant Item. |
| 68 | M&L TMT Bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for Columns, hooking Ends and binding with and including Mild Steel Wire (annealed) not less than 0.90 mm dia, complete all as specified and directed. Please Enable Macros to View BoQ information |