| 1 | Item Rate BoQ BoQ_Ver3.0 Item Rate Normal INR Only INR Select, Excess (+), Less (-) Less (-) Tender Inviting Authority: GE Utilities Udhampur Name of Work:Repair/Maint of LT Cables, voltage stabilizers, LT Switchgear, Earthings and allied works at B-Reserviour, R-Center, Old MH Filter Plant and Garhi Cantt under GE (U) Udhampur. Contract No: GE/U-71/2026-27 Bidder Name : PRICE SCHEDULE(This BOQ template must not be modified/replaced by the bidder and the same should be uploaded after filling the relevent columns, else the bidder is liable to be rejected for this tender. Bidders are allowed to enter the Bidder Name and Values only ) NUMBER # TEXT # TEXT # NUMBER # TEXT # NUMBER NUMBER TEXT TEXT # NUMBER # TEXT# TEXT # NUMBER # NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER NUMBER TEXT TEXT NUMBER NUMBER NUMBER # NUMBER # TEXT TEXT NUMBER # NUMBER # DATE NUMBER # NUMBER # TEXT # Ser.No. Item Description Item Code / Make Quantity Units Estimated Rate Addition / Deduction Addition / Deduction Values Currency Convertion against each Item Quoted Currency in INR / Other Currency BASIC RATE In Figures To be entered by the Bidder Rs. P Excise Duty VAT Freight Charges ( Unloading & Stacking) Any Other Taxes/Duties/Levies Other Taxes 2 IIIrd Party i.e DGS&D / RITES etc Inspection Charges @0.34%+Service Tax Less for Cenvat Credit,if any respect of Supplies Under full Excise Duty Category TOTAL AMOUNT Without Taxes TOTAL AMOUNT TOTAL AMOUNT In Words |
| 2 | Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete all as specified and directed by Engineer-in-Charge. |
| 3 | Returning, filling in including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and directed by Engineer-in-Charge. |
| 4 | Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified and directed by Engineer-in-Charge. |
| 5 | M&L for PCC 1:4:8 type D-2 using 40mm graded aggregate, mechanically crushed stone for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and directed by Engineer-in-Charge. |
| 6 | Supply and fix indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5/4.0 x 10-50 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 7 | Supply and fix indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 70-150 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 8 | Supply and fix indoor/outdoor end termination joint heat shrinkable 1100 Volts for XLPE cable of size 3.5 x 185-300 Sqmm complete all as specified and directed by Engineer-in-Charge. |
| 9 | Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc , complete all as specified and directed by Engineer-in-Charge. |
| 10 | Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 25 sqmm 3.5 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, sand, bricks , removing, returning filling Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost. |
| 11 | Description all as per Item Ser No 9.00 here- in- before, but for 3.5 core 35 Sqmm. |
| 12 | Description all as per Item Ser No 9.00 here- in- before, but for 3.5 core 50 Sqmm. |
| 13 | Description all as per Item Ser No 9.00 here- in- before, but for 3.5 core 95 Sqmm. |
| 14 | Description all as per Item Ser No 9.00 here- in- before, but for 3.5 core 185 Sqmm. |
| 15 | Description all as per Item Ser No 9.00 here- in- before, but for 3.5 core 240 Sqmm. |
| 16 | Description all as per Item Ser No 9.00 here- in- before, but for 3.5 core 400 Sqmm. |
| 17 | M&L in replacement for 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as specified and directed by Engineer-in-Charge. |
| 18 | Dismantling and taking down old u/s earthing and Material & labour for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and directed by Engineer-in-Charge. |
| 19 | Dismantling and taking down old u/s earthing and Material & labour for earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth wire of size 4 mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 20 mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and directed by Engineer-in-Charge. |
| 20 | Material and labour for fixing in replacement GI tubing 50 mm bore light grade, on poles,on walls, under floors, road crossing, as reqd at site complete all as specified and directed by Engineer-in-Charge.Note: Clamps, Nut bolts, saddle etc will be measured and paid separately. |
| 21 | Description all as per Item Ser No 19.00 here- in- before, but of size 80 mm dia |
| 22 | Supply and Fixing in replacement MCCB TPN 400 Amps , 415 Volts, 36 KA ,4 POLE, Ics=100% Icu ,overload adjustable short circuit adjustable type incl complete all as specified and directed by Engineer-in-Charge. |
| 23 | Supply and Fixing in replacement MCCB TPN 250 Amps , 415 Volts, 25 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection with suitable spreaders complete all as specified and directed by Engineer-in-Charge. |
| 24 | Supply and Fixing in replacement MCCB TPN 200 Amps , 415 Volts, 25 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection with suitable spreaders complete all as specified and directed by Engineer-in-Charge. |
| 25 | Supply and Fixing in replacement MCCB TPN 160 Amps , 415 Volts, 16 KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection with suitable spreades complete all as specified and directed by Engineer-in-Charge. |
| 26 | Supply and Fixing in replacement MCCB TPN 100 Amps , 415 Volts, 16KA ,4 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection with suisuitable spreaders complete all as specified and directed by Engineer-in-Charge. |
| 27 | Supply and Fixing in replacement MCCB TP 400 Amps , 415 Volts, 36 KA ,3 POLE, Ics=100% Icu ,overload adjustable short circuit adjustable type incl complete connection with suitable spreaders complete all as specified and directed by Engineer-in-Charge. |
| 28 | Supply and Fixing in replacement MCCB TP 250 Amps , 415 Volts, 25 KA ,3 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection with suitable spreaders complete all as specified and directed by Engineer-in-Charge. |
| 29 | Supply and Fixing in replacement MCCB TP 200 Amps , 415 Volts, 25 KA ,3 POLE, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection with suitable spreaders complete all as specified and directed by Engineer-in-Charge. |
| 30 | Supply and Fixing in replacement MCCB TP 160 Amps , 415 Volts, 16 KA ,3 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection with suitable spreaders complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply and Fixing in replacement MCCB TP 100 Amps , 415 Volts, 16 KA ,3 POLE, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection complete all as specified and directed by Engineer-in-Charge. |
| 32 | Taking down unsv existing change over & Supply, fixing in replacement off load changeover switches 4 pole 630 Amps , 415 volts , with enclosure complete all as specified and directed by Engineer-in-Charge.Make: Hager/Legrand/ Schneider/IndoAsian |
| 33 | Taking down unsv existing change over & Supply and fixing in replacement off load changeover switches 4 pole 20 Amps , 415 volts , with enclosure complete all as specified and directed by Engineer-in-Charge.Make: Hager/Legrand/ Schneider/IndoAsian |
| 34 | Material and labour for fixing in replacement of stainless steel nuts, bolts, washers of any size required at site incl dismantling old rusted nuts bolts complete all as specified and directed by Engineer-in-Charge. |
| 35 | Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm incl dismantling old thimbles of any type, complete all as specified and directed by Engineer-in-Charge. |
| 36 | Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm incl dismantling old thimbles of any type, complete all as specified and directed by Engineer-in-Charge. |
| 37 | Material and labour for fixing aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm incl dismantling old thimbles of any type, complete all as specified and directed by Engineer-in-Charge. |
| 38 | M & L for cutting of road/PCC footpath/hard standing/interlocking tiles work including excavation for laying cable/pipe and making good surfaces as per existing specification complete all as specified and directed by Engineer-in-Charge. |
| 39 | Material and labour for shifting heavy items / excavating / cleaning areas / clearing site by providing crane/hydra/excavators/tractors/trolley etc as required at site complete all as specified and directed by Engineer-in-Charge. |
| 40 | M&L for Chemical spray (DC> 2-26 having container 415ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricates, displaces and seals out moisture release rusted mechanism cleanse etc, complete all as specified and directed by Engineer-in-Charge. |
| 41 | M& L for painting to LT panel board/LT feeder pillar box up to 0.6x.06.x.5 M indoor/out door type of size inner shell & outer shell including angle iron frame by applying two coats of sunthetic enamelled paint over a red oxide primer after cleaning of panel board inner shell & outer shell by means of rubbing by sand paper griding and removing rusted and corrded particles cleaning with cloths including reparing smooth surface for painting complete all as specified and directed by Engineer-in-Charge. |
| 42 | Description all as per Item Ser No 40.00 here- in- before, but of size up to 1.0 x.9x.5 M, complete all as specified and directed by Engineer-in-Charge. |
| 43 | Description all as per Item Ser No 40.00 here- in- before, but of size up to 1.2x.9x.5 M, complete all as specified and directed by Engineer-in-Charge. |
| 44 | Description all as per Item Ser No 40.00 here- in- before, but of size up to 2.0 x1.2 x.5 M, complete all as specified and directed by Engineer-in-Charge. |
| 45 | M & L for maintance of LT feeder pillar /LT panel board any type and size indoor/outdoor by dismandling opening and taking down of all incoming and outgoing cables,cutting burnt edge of the cable what ever is required ,providing thimble lugs of suitable required for different size of cable including taking out loop of the cables, cleaning of bus bars by menas of rubbing grinding etc and providing PVC sleeves of suitable rating on bus bars maintaing colour code (RYB & N) including replacement of bolts nuts & wanshers and reconnecting the all incoming and outgoing connections and testing of panles on full load complete all as specified and directed by Engineer-in-Charge. |
| 46 | Labour only for welding of existing unserviceable door hinges of LT feeder pillar/LT panel board indoor/out door type of different size panels at different size panels at different locations including adjusting the door for smooth opening and closing of the panel boards complete all as specified and directed by Engineer-in-Charge. |
| 47 | Material & Labour for surface cleaning of steel tubular poles LT 9 mtrs long including removing rusted particles and painting with two coats of synthetic enamel aluminium paint over a coat of red oxide including cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc and providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl repairing and painting on coping with cement base white paint complete all as specified and directed by Engineer-in-Charge. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall including the reparing of coping with cement / PCC. |
| 48 | Material & labour for repairing existing earthing any type incl making & cleaning of earth pit, repair of pits, fixing of new funel , pit cover, painting on pit with cement base white paint complete all as specified and directed by Engineer-in-Charge.Note: (i) Cost of funel, pit cover, cement work, PCC work and painting etc incl is quoted rate. |
| 49 | Supply and fixing of Earth continuity strip or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 24x4 mm GI strip complete all as specified and directed by Engineer-in-Charge. |
| 50 | M & L for spraying chemical on area to remove unwanted vegitation/grass at various locations complete all as specified and directed by Engineer-in-Charge. |
| 51 | Dismantling and taking down old unsv LT Panel and Supplying, installing, testing & commissioning indoor type cubical panel board outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick and MS angle section 50x50x6 mm mounted on platform with nut and bolts, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Al bus bar of 1200 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following, complete all as specified and directed by Engineer-in-Charge:- |
| 52 | a) 4 Nos bus bar of equal size made out of copper strip of suitable size with PVC insulated coloured heat shrinkabal type sleeves, of rating 1200Amps, mounted on non cracking resin type insulators - 01 Jobb) LT ACB, 4 pole, 415 volts, 50 kA, 800 Amps mannual draw out type with thermal magnetic release, Icu=Ics=Icw 50kA (1 Sec) with accessories confirming to IEC 60947-2&3 - 01 No (Incoming)c) MCCB TPN 400 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection 02 Nosd) ON Load Change over 630Amps 415 V with interconnection to incomer ACB e) Under voltage, over voltage ,over load relay,phase sequence corrector - 01 Jobf) Interconnection of MCCBs to Busbar with copper strip of suitable size with PVC insulated colour coaded heat shrinkable type sleeves - 1 Jobg)RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nosh)Digital Ammeter of range 0-800 A, auxiliary voltage 230 volts with selector switch -02 Nosi) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 Noj)Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cable lugs, sleeves, cable glands etc complete |
| 53 | Note for item no (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc.(ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694.(iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE.(iv)The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulat (v) Cable will be entered in panels through gland. (vi)Cost of marking description on the front door as per direction of Engr-in-Charge is incl in quoted rate. |
| 54 | Dismantling and taking down old unsv LT Panel and Supplying, installing, testing & commissioning indoor type cubical panel board outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform with nut and bolts, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Aluminium bus bar of 800 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-- |
| 55 | a) 4 Nos bus bar of equal size made out of Aluminium strip of suitable size with PVC insulated coloured heat shrinkabal type sleeves, of rating 800Amps, mounted on non cracking resin type insulators - 01 Jobb) MCCB TPN 400 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection 01 Nos (Incoming)c) MCCB TP 250 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection 03 Nosd) Soft starter suitable for 75 HP,analog display of motor current,Electronic over load,under load and locked rotor protection. 02 Nose) Under voltage, over voltage ,over load relay,phase sequence corrector - 01 Jobf) Interconnection of MCCBs to Busbar with copper strip of suitable size with PVC insulated colour coaded heat shrinkable type sleeves - 1 Jobg)RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nosh)Digital Ammeter of range 0-800 A, auxiliary voltage 230 volts with selector switch -02 Nosi) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 Noj)Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cable lugs, sleeves, cable glands etc complete |
| 56 | Dismantling and taking down old unsv LT Panel and Supplying, installing, testing & commissioning indoor type cubical panel board outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform with nut and bolts, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Aluminium bus bar of 200 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following, complete all as specified and directed by Engineer-in-Charge:-- |
| 57 | a) 4 Nos bus bar of equal size made out of Aluminium strip of suitable size with PVC insulated coloured heat shrinkabal type sleeves, of rating 200Amps, mounted on non cracking resin type insulators - 01 Jobb) MCCB TPN 100 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection 01 Nos (Incoming)c) MCCB TP 63 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection 03 Nosd) In built DOL starter suitable for 10 HP motor. 03 Nos with relays.e) Under voltage, over voltage ,over load relay,phase sequence corrector - 01 Jobf) Interconnection of MCCBs to Busbar with AL strip of suitable size with PVC insulated colour coaded heat shrinkable type sleeves - 1 Jobg)RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nosh)Digital Ammeter of range 0-100 A, auxiliary voltage 230 volts with selector switch -02 Nosi) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 Noj)Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cable lugs, sleeves, cable glands etc complete |
| 58 | M & L for fabrication and replacement of old unserviceable out shell/inner shell cover factory made suitable for different size of panels.feeder pilllar boxes according to site and welding of hinges with outer/inner shell. Provision of locking PVC head bolts for outr/inner shell cover as required at site complete all as specified and directed by Engineer-in-Charge. |
| 59 | Material & Labour for Aricircuit Breaker, fixed type, spring operated, mannualy TPN, 4 Pole, 800 Amps, 415 Volt with Thermal magnetic release,(O/L, S/C, E/F protection & confirming to IEC - 60947-2 &3rated breacking capacity / making capacity 50 KA short time current complete all as specified and directed by Engineer-in-Charge. |
| 60 | Supply and installation of all in one integrated solar street light 25 Watt compact,aesthetic ecco friendly and modern integrated solar street in extruded aluminium housing with high efficiency mono crystaline silicon photo voltaic panel,high efficency SMD LED 6500K having secondary lens optic for street light distribution ,high performance lithium battery ,MPPT charge controller and intelligent controlmodule/sensor with higher reliability long service life,incl GI pipe not less than 63mm dia upto 4 mtr height for mounting of solar lights,suitable for easy and quick installation pcc 1: 3: 6 type C1(using 20mm stone aggregate) complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply, Laying and connecting including testing underground XLPE cable PVC insulated and over all sheathed with aluminium conductor heavy duty 1100 volts grade Cross sectional area 400 Sqmm Single core, laid in trenches, floors, ducts passing through pipe for road crossing etc complete all as specified and directed by Engineer-in-Charge. |
| 62 | Material and labour for hardcore broken stone or boulders filling of gauge not exceeding 63 mm, deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface complete all as specified and directed by Engineer-in-Charge. |
| 63 | M & L for highly HT insulating opaque red coloured ANTI TRACK COMPOUND SPRAY 320 of MOSIL LUBICANTS that forms flexible chemical resistank coating to class H winding for electrical apparatus, in 500 ml spray bottles to protect HT equipments, bus bar, CTs, PTs from current leakage due to moisture complete all as specified and directed by Engineer-in-Charge. |
| 64 | S & F self-fusing Ethylene Propylene Rubber(EPR) based high-insulating voltage tape of width not less than 25 mm and thickness not less than 0.76 mm(Roll of 9/10M) of any length to protect HT/LT XLPE cable from moisture and current leakage complete all as specified and directed by Engineer-in-Charge. |
| 65 | Supply and laying DWC (Double wall corruguated) pipe 50/63 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing, complete all as specified and directed by Engineer-in-Charge. |
| 66 | Supply and laying DWC (Double wall corruguated) pipe 100/110 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing, complete all as specified and directed by Engineer-in-Charge. |
| 67 | Supply and laying DWC (Double wall corruguated) pipe 150/160 mm conforming to IS-14930/ IS-16205 for protection of earth strip/cable including necessary snap fit coupler reqd for fixing, complete all as specified and directed by Engineer-in-Charge. |
| 68 | M&L in replacement of PVC insulated heavy duty industrial cables single core copper conductor(flexible) PVC insulated cable 1100 volt nominal area of conductor 185 sqmm inculding taking down existing old unserviceable cable of complete all as specified and directed by Engr-in-Charge. |
| 69 | Dismantling and taking down old unsv LT Feeder pillar and Supplying, installing, testing & commissioning outdoor type cubical panel board outer shell made out of 3.15 mm thick CRCA sheet and inner shell made out of 2 mm thick and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform with nut and bolts, frame factory fabricated with front and back openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able with arrangement of pad locking on both doors incl 2 no. of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, incl Aluminium bus bar of 600 A , tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following, complete all as specified and directed by Engr-in-Charge :-- |
| 70 | a) 4 Nos bus bar of equal size made out of Aluminium strip of suitable size with PVC insulated coloured heat shrinkabal type sleeves, of rating 600Amps, mounted on non cracking resin type insulators - 01 Jobb) MCCB TPN 400 Amps, 415 Volts, 36KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection 01 Nos (Incoming)c)RYB indication LED type, 22.5 mm dia, protected with MCB SP 2 Amp showing 3 phase supply -03 Nosh)Digital Ammeter of range 0-400 A, auxiliary voltage 230 volts with selector switch -02 Nosi) Volt meter of range 0-500 Volts, auxiliary voltage 230 volts with selector switch -1 Noj)Misc items like screws, cable tie, copper cable 1.5/2.5 Sqmm, cable lugs, sleeves, cable glands etc complete |
| 71 | M&L in repairs/service for opening faulty / defective servo voltage stabilizer of cap 10 KVA to 50 KVA 415 volts opening the top cover of servo voltage stabilizer, carrying out the repairs /works listed at serial No. (i) to (xi) below |
| 72 | (i) Taking out the core/coil of servo voltage stabilizer from tank , After dismantling of servo voltage stabilizer and physical joint inspection of core coil assembly washing of core assembly by hot oil for removing brunt carbon and copper particles and cleaning of complete top by oil(ii) Painting inside of the servo voltage stabilizer with yellow paint and outside body with synthetic enamel paint of existing tint/color Cleaning inside of the servo voltage stabilizer by using oil.(iii) Refixing/ reassemble of complete core assembly and core coil assembly providing new coils including requisite insulation material including heating up the core assembly to remove moisture after carrying out the repairs works .(iv) Renewal of rubberized gasket set for top cover.(v) Refilling of the decanted oil after centrifuging and testing for required di-electric strength.(vi) Refixing the top cover with nuts, bolts and washers and ready for final testing all as directed in presence of rep of MES.(vii) Preparing Inspection report for renewal of parts etc in presence of Engineer - in- charge and Contractor.(viii) Replacement of Push button,Auto/Manual switch,limit switch,lever switch(ix) Soldering/ brazing or connecting with suitable size nuts, bolts and washers |
| 73 | (x) Providing necessary insulation papers, sleeves, PVC pipes insulation sheet etc.(xi) Renewal of worn out nuts, bolts and washers:,Servo control panel |
| 74 | Description all as per Item Ser No 65.00 here-in-before, but of capacity of 100 KVA |
| 75 | Description all as per Item Ser No 65.00 here-in-before, but of capacity of 400 KVA |
| 76 | Supplying and filling/topping up transformer oil low viscosity, dielectric strength 35 to 40 KV breaking voltage for topping up servo voltage stabilizers duly centrifuging including filter action by using automatic centrifuging machine to achieve min 35 to 40 KV breaking capacity at 4 mm gap by absorbing and abolishing all sludge particles for use as per BS-B-66-1983 complete all as specified and directed by Engr -in Charge. |
| 77 | Material and Labour in repairs for rewinding dimmer/transformer with copper wire DPC/super enameled high quality matching with existing gauge and impedance including requisite insulating paper/material in each layer of winding after taking down old existing winding of coils of servo voltage stabilizer complete all as specified and directed by Engr -in Charge.:- |
| 78 | M&L for on line Dehydration/filtration of Servo Voltage Stabilizer oil including filtration using automatic centrifuging machine minimum three cycles to achieve dielectric strength 40 to 60 KV breaking capacity at 2.5mm gap by absorbing and abolishing all sludge particles as per BS-66-1963 including topping up with new transformer oil as required complete all as specified and directed by Engr-in-Charge. Note- (i) Centrifuging Machine with all T&P & testing machine of oil required for dehydration shall be arrange by contractor. (ii) topping up oil for the stabilizer will be measured & paid separately as supply only under respective item of this Sch.: |
| 79 | M&L for repair/replacement of dimmer 10Amps suitable for voltage stabilizer complete all as specified and directed by Engr -in Charge. |
| 80 | M&L for repair/replacement of transformer 400KVA suitable for voltage stabilizer complete all as specified and directed by Engr -in Charge. Total in Figures 0.0 0.0 INR Zero Only 4.0 Construction of chamber for 100mm sluice plates item5 10.0 Nos Quoted Rate in Figures Select 0.0 0.0 Zero Only Quoted Rate in Words INR Zero Only Please Enable Macros to View BoQ information |