| 1 | Excavation intrenches, not exceeding 6.5M wide and not exceeding 1M depth for foundation, etc., and getting out any type of soil. |
| 2 | M&L for PCC 1:5:10 type E-2 (40mm graded aggregate) in foundation filling and mass concrete. |
| 3 | M &l For providing Hardcore of gauge exc 63mm but n. exc 100mm, deposited spresd and levelled in layers n. exc. 15cm thick , watered to a true surface of broken stone boulders all as specified. |
| 4 | M & L 100mm thick for cement concrete 1 : 4 :8 type D-2 all as specified as in sub base in trenches for pillar . |
| 5 | RCC Pillars – Construction of RCC Pillars 12’X12” with foundation bolts to hold “I” beam of 6” X 4 “ with compatible pads. Based on soil the depth is considered 3 ft below ground and 2 ft above ground level in M30 concrete with requisite . TMT bars 8/12mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookings ends and binding mild or securing with clips conform |
| 6 | Pillars– Supply and installation of “I” beam of 6” X 4 “ with compatible pads as pillars to support the steel sheet roof fixed on Beams. The Height of each I beam pillars is 11 Ft & 14 clear height from ground each with 12 MM 8’X8” MS Plate duly welded to I Beams. |
| 7 | Plinth beam The RCC pillars be joined together by plinth beam having Min. size of 12’ X 12” Laying TMT bars 8/12mm dia and over cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hookings ends and binding mild or securing with clips conform (Fe-410w or Fe-290) as specified. |
| 8 | Returning filling in excavated material in to trenches around pipe after laying of pipes and testing complete incl watering and well remming in layers n exc 25 cm thick complete all directed |
| 9 | M &l For providing Hardcore of gauge exc 63mm but n. exc 150mm, deposited spread and levelled in layers n. exc. 15cm thick , watered to a true surface of broken stone boulders all as specified. |
| 10 | M & L 100mm thick for cement concrete 1 : 3 :6 type D-2 all as specified as in sub base such as the entire structure shall be at a height of 24 inches from ground level with joining all foundation, Plinth Beam |
| 11 | Beams– Supply and installation of“L” angle beam of 5 with compatible pads to support the steel sheet roof fixed on Beams. duly welded to I Beams |
| 12 | Transverse Beams- Supply and installation of” “I” beam of 4” X 2.5” “ joined with pillars using Fasteners, Welding as required to fabricate the frame work for holding steel sheet of the roof. |
| 13 | Brick work M & L for brick work with sub class B bricks for all outer walls of 9 inches thick wall including single coat of plaster ( 15mm) on internal surface and double coat of plaster ( 25 mm = 15mm + 10 mm) on outer surface with water proofing compound complete. PCC blocks in place of Red Bricks can also be used at discretion of contractor. RCC lintel with 02 in Nos. 12 mm TMT Bar is required to be laid at mid level for strength |
| 14 | Brick work M & L for brick work with sub class B bricks for all inner walls of 5 inches thick wall including single coat of plaster ( 15mm) on internal surface smoothed for application of 02 MM Wall Putty/ Fixing of Tiles as required. PCC blocks in place of Red Bricks can also be used at discretion of contractor. RCC lintel with 02 in Nos. 12 mm TMT Bar is required to be laid at mid level for strength |
| 15 | Flooring tiles (vitrified double glazed ) 2 Feet X 2 Feet or above sizes in all rooms and Non Skid Tiles on floors including skirting duly flushed in walls of reputed brands such as Bell, Sumani, AGL or similar brands of approved make and shade. The design of fixing shall be approved by inspecting authority. |
| 16 | Roof :- Roof of 50 mm thick powder coated corrugated sheet Sandwich with PU Foam of brand like Jindal or equivalent fixed on suitable frames and traces of square pipe / angle bars / GI pipes. Roof Height shall be around 16.5 feet in centre of hall and 12 feet on walls and projected at least 3 feet outside of the side walls. |
| 17 | Windows Supply and fitment of sliding window fixed on Four track aluminium anodized framing size 6 feet X 4 feet with 03 No. Glass Shutter and 01 No. Mosquito proof wire mesh . The window frame is required to be fixed on Green marble sill and Jam fixed on walls in two layers to avoid water seepage into the rooms. Safety Grill/Alumunium Deco grill is to be fixed on all windows from outside. |
| 18 | Doors :- Size 4 ft X 7 Ft marine flush door of 35 mm Thickness with decorative laminates of approved shade on either side fixed on wooden chowkat frame of B Class hard wood of 5”X3” wood with standard hardware fittings and locking arrangement complete |
| 19 | False Ceiling – Arm strong false ceiling is to be provided in main hall, porch and all the WC and bathrooms in such a way that the height of ceiling from floor to false ceiling is minimum of 13 feet ( except stage and Porch) The False ceiling sheet fixed on Armstrong should be of water proof type. |
| 20 | Earthing :- Earthing complete with galvanized steel earth plate electrode 600 x 600 mm x 6mm thick, buried directly in ground, earth pit not less than 2.25 meters deep below normal ground including all related works at 04 locations |
| 21 | BLDC Electric Celing Fan |
| 22 | Ceiling Down Light 24” X 24” |
| 23 | Mfg and Fitting of MCB Electrical panel with 8 MCB points of 10/20 Amps each |
| 24 | Wiring cables with switches and 04 Nos Sokets fitted on all walls and 02 Nos 15 Amp Socket in each room complete with Switch box, Conduct etc. |
| 25 | Painting :- Painting on internal surface of hall shall be done post levelling of surface by POP / GYPSUM and coat of putty with one coat of primer and two coats of Oil Bound distemper of approved shade of reputed brand such as berger, Asian & Nerolac.. |
| 26 | Painting on external surface with one coat of primer and two coats of acrylic weather coat approved shade of reputed brand such as berger, Asian & Nerolac |
| 27 | Painting on MS Surface with one coat of Red Oxide and two coats of Synthetic enamel of approved shade of reputed brand such as berger, Asian & Nerolac. |
| 28 | Plinth Protection – Building is to be given 3 feet wide plinth protection all around the building. Please Enable Macros to View BoQ information |