| 1 | DESCRIPTION OF ITEMS |
| 2 | Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credits and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site. |
| 3 | Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed. |
| 4 | Taking down carefully copper/aluminium Sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors roofs etc complete all as specified and directed. |
| 5 | M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including Concealed PVC conduit of size 20/25mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :- |
| 6 | (a) One light point controlled by one, one way switch 5 Amps |
| 7 | (b) One light point controlled by one, two way switch 5 Amps |
| 8 | (c) One fan point/ exhaust fan point controlled by one, one way switch 5 Amps and regulator |
| 9 | (d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board. |
| 10 | (e) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent board. |
| 11 | (f) One bell point controlled by one, bell switch 5 Amps |
| 12 | Description all as per item No 4 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly. |
| 13 | S & F for Modular Switch one way 6 amp, 1 module 230 Volts complete all as specified and directed at site. |
| 14 | S & F for Modular Switch two way 6 amp, 1 module 230 Volts complete all as specified and directed at site. |
| 15 | S & F for Modular Switch one way 16 amp, 1 module 230 Volts complete all as specified and directed at site. |
| 16 | S & F for Modular bell push 6 amp, 1 module 230 Volts complete all as specified and directed at site. |
| 17 | S & F for modular socket outlet 2/3 pin combined, 6 amp,2 module 230 Volts complete all as specified and directed at site. |
| 18 | S & F for modular socket outlet 2/3 pin combined, 6A/16A amp,2 module 230 Volts complete all as specified and directed at site. |
| 19 | S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified |
| 20 | S & F for modular fan step regulator 120W- 2 module complete all as specified and directed at site. |
| 21 | S & F for lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed. |
| 22 | S & F for Bell Electric Ding dong type suitable for operation on 230 volt 50 HZ A C supply complete all as specified and as directed |
| 23 | S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site. |
| 24 | S & F for Switch Piano type 2 way switch 5 amp, 230 Volts complete all as specified and directed at site. |
| 25 | S & F for Switch Piano type single pole 15 amp, 230 Volts complete all as specified and directed at site. |
| 26 | S & F for switch bell push piano type 5 amp, 230 Volts Complete all as specified and directed at site. |
| 27 | S & F for socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site. |
| 28 | S & F for socket outlet 2 in 1 , 5 pin, 15 amp, 230 Volts complete all as specified and directed at site. |
| 29 | S & F for stepped type electronic fan regulator flushType complete all as specified and directed at site. |
| 30 | M & L for Sub main wiring with approved colour coding as per IS with two single core PVC insulated FRLSH cable with stranded copper conductor of size 6 Sq mm nominal area and drawing into suitable size of PVC non metallic rigid heavy duty concaled PVC conduit of white/ ivory colour and its accessaries ISI marked heavy duty of suitable size including concealed in wall etc one run of PVC insulated with 6.0 Sqmm (nominal area) stranded copper conductor FRLSH cable as earth wire complete all as specified and as directed. Note:- Two runs of 6 sqmm cable,one run of 6 sqmm cable and one run of PVC conduit will be measured as one unit |
| 31 | S&F MCB DB sheet metal enclosure for DB, TPN, 4 way having protection with 200 amps rated bus bar, 240 volts, double door type, suitable for housing MCB's and isolators, concealed in wall, complete all as specified and directed. |
| 32 | S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 33 | S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed. |
| 34 | Supply & fixing Sheet Metal Enclosures vertical TPN distribution board with provision for & including 100 Amp MCCB as incomer with necessary internal wiring, with provision for 12 Nos. MCBs as outgoing , 4 way, 415 Volt, Double door for housing MCB's/Isolators and flush to wall including all cutting etc on wall and making good the disturbed surfaces with painting the wall to match the existing all as specified & directed. |
| 35 | S&F MCB, 433 volts, B Curve, 100 Amps of 10 KA, complete all as specified and directed. |
| 36 | S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 37 | S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed. |
| 38 | S & F for metal clad box suitable for 230 volt 50 Hz AC supply three pin with MCB SP 20/32 Amps complete all as specified and as directed complete all as specified and as directed |
| 39 | Labour only for refixing the celing fan with copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal complete all as specified and as directed. |
| 40 | S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap complete all as specified and directed |
| 41 | S&F in repair LED integrated batten box type surface mouted, 1x20 Watt prewired including electric electrical connection with PVC insulated twin twisted copper wire of suitable size from ceiling rose to tube light fitting and including taking down old fitting complete all as specified and directed. |
| 42 | Supply and fixing LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with PVC insulated twin twisted copper wire of suitable size complete. |
| 43 | S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with PVC insulated twin twisted copper wire of suitable size complete. |
| 44 | Supply and fixing LED Bldg sec light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete. |
| 45 | Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders,LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete. |
| 46 | Supply and fix in replacement of decorative wall light fixture made up of polycarbonate suitable for 10 W retrofit LED lamp and including 10 W LED lamp and including all accessories for fixing of fitting on wall all as specified and directed by Engr-in-Charge. |
| 47 | Supply and fixing in repair LED POST TOP LANTERN 20 W , IP -65 including all accessories for fixing alongwith iron cage around it complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply and installed LED Flood light 70 watt die cast aluminium housing comprising high power AC outdoor type with thermal management and IP-66 protection with impact and corossion resistant including all needed accessories to fix it on wall/Tree/pole complete all as specified and directed by Engr-in-Charge. |
| 49 | Supply & Fix in repairs LED driver suitable for 25 w LED security lights complete all as specified and directed by Engr-in-Charge. |
| 50 | Supply & Fix in repairs LED driver suitable for 35 w LED security lights complete all as specified and directed by Engr-in-Charge. |
| 51 | Supply & Fix in repairs LED driver suitable for 45 w LED security lights complete all as specified and directed by Engr-in-Charge. |
| 52 | S & F in repair, security light brackets of 32 mm dia GI pipe medium grade upto 0.6 mtr long bend to required shape including flat iron clamps- 02 Nos with suitable size of nuts and bolts including grouted in wall complete, including distempering to match with existing surface all as specified and directed . |
| 53 | M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0mm dia Protedcted by light GI Pipe 20 mm dia and 15 dia med grade for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamber all as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed. |
| 54 | Supply and fixing LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light white/warm white as per requirement complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with PVC insulated twin twisted copper wire of suitable size complete. |
| 55 | Supply and Fixing in replacement LED bulb 12W,5 star rated voltage 220-240, 50 Hz, CDL 1200 lumen B22 base type for batten/angular lamp holder as directed by Engr-in-charge. |
| 56 | Supply and Fixing in replacement LED bulb 7 W in built voltage surge protection upto 3.5 KV, Cool day light 665 Lumen B22 base type for batten/angular lamp holder as directed by Engr-in-charge. |
| 57 | Supply and fixing 3 mm laminated sheet suitable for Switch board and cut for suitable no. of switches ,socket and fan regulatoras as per site requirement complete all as specified and directed. |
| 58 | M/L for fixing in repair pressed steel terminal box 60 mm deep with 3 mm thick laminated sheet on top of size 75mmx75mm for mounting switch/socket/ regulator incl taking out old box & making good the disturbed surface as per existing including cutting/chasing complete all as specified & directed. |
| 59 | All as per item No. 51but ,100mmx100mm size complete all as specified and directed by Engr-in-Charge. |
| 60 | All as per item No. 51 but ,100mmx75mm size complete all as specified and directed by Engr-in-Charge. |
| 61 | All as per item No. 51 but ,175mmx100mm size complete all as specified and directed by Engr-in-Charge. |
| 62 | All as per item No. 51 but ,200mmx150 mm size complete all as specified and directed by Engr-in-Charge. |
| 63 | Disconnecting carefully water and electric connection from storage type water heater of 25/35/50 Ltr capacity of any make and dismantling for repair by taking out the syphon assembly of thermostat, heating element and cleaning, de-scaling the inner tank by de-scaling with chemical compound including soldering, brazing the inner tank if required, re-assembling the geyser after cleaning & servicing including replacement of flexible cable of size 2.5 sqmm 3 core with copper conductor up to 1.5 mtr long and re-fixing in existing position complete all as specified and directed. Note:- The rate quoted is deemed to include cost of soldering/brazing work and glass wool superior quality if required at site. |
| 64 | S & F in repair heating element including rubber gasket & washer and complete etc. of capacity 1.5/2 KW as per reqirement suitable for existing make and shape all as specified and directed. |
| 65 | S & F in repair complete assembly alongwith heating element 1.5/2 KW including rubber gasket & washer, complete suitable for existing make and shape all as directed. |
| 66 | S&F Thermostat including rubber/ PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 /35/ 50 ltrs including taking down existing unserviceable thermostat complete all as specified and as directed. |
| 67 | M&L for preparation of surface of geyser 25/50Ltrs capacity by scrapping and applying one coat of sythetic enamel paint of approved colour including tinkering and welding if required at site all as specified and directed. |
| 68 | S&F PVC connecting pipe 18\\" long with brass adopters for hot and cold water and connecting up with complete for 25 /35/ 50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe complete all as specified and directed. |
| 69 | S&F Indicator light for geyser of any make and capacity. Please Enable Macros to View BoQ information |